| 1 | M&L for cleaning of SGSW / RCC / PVC sewage line upto 250mm dia by rodding / auger rods & drain pipe machine as required from manhole to manhole including gully trap and getting out the sludge from any size of manholes & gully traps before & after cleaning process of SGSW / RCC / PVC sewage line and well flushing using clean water through water bowser pipe of any capacity (arranged by the Contractor) and removing the sludge etc to a distance n.exc 250m and burying the same underground by digging pit of suitable size from habitant area and returning & filling with excavated materials upto ground level including removal of surplus soil to a distance n. exc 250m with and including taking off manholes / gully trap covers and re-fixing the same after cleaning process complete all as specified and directed by Engr-in-Charge. Note : 1. The Contractor / site supervisor will attend the complaint cell of AGE B&R-III to receive the complaint slips daily at 0900hrs to carry out the complaints and completion report will be submitted to concerned JE / AGE in the same day i.e. before 1700hrs.2. If Contractor is to be failed to carry out to completion the jobs within the stipulated time period, the recovery will be chargeable at the rate of Rs. 80.00 per RM for every day. |
| 2 | M&L for cleaning / taking off of sludge (solid / semi solid) of any state from manhole of any size including gully trap having depth upto 3.00m by using machinary or manually as required and removing the same to a distance n.exc 250m and burying the same underground by digging pit of suatible size from habbatient area and returning & filling with excavated materials upto ground level including removal of surplus soil to a distance 250m with and includig taking off manholes / gully trap covers and re-fixing the same after cleaning process complete all as specifed and directed by Engr-in-Charge.Note : 1. The Contractor / site supervisor will attend the complaint cell of AGE B&R-III to receive the complaint slips daily at 0900hrs to carry out the complaints and completion report will be submitted to concerned JE / AGE in the same day i.e. before 1700hrs.2. If Contractor is to be failed to carry out to completion the jobs within the stipulated time period, the recovery will be chargeable at the rate of Rs. 190.00 per Each Job for every day. |
| 3 | M&L for opening / cleaning of blocked WC of any type, traps and CI / PVC drain pipe including fittings (i.e. access door bends / tee etc) of any size at any floor & position with and including taking down of CI / CP / PVC grating and refixing the same at position with appropriate materials / fittings i.e. white cement, solvent, nuts & bolts etc and well flushing, pressure pumping, taking out all residue materials etc and removing the same to distance not exc 250 mtr, burried the same underground by digging pit of suatible size from habbatient area and covering same wrt the earth level including removal of surplus soil to a distance 250m, complete all as specified and directed by the Engr-in-Charge. Note : 1. The Contractor / site supervisor will attend the complaint cell of AGE B&R-III to receive the complaint slips daily at 0900hrs to carry out the complaints and completion report will be submitted to concerned JE / AGE in the same day i.e. before 1700hrs.2. If Contractor is to be failed to carry out to completion the jobs within the stipulated time period, the recovery will be chargeable at the rate of Rs. 90.00 per Each Job for every day. |
| 4 | M&L for dewatering of contaminated waste effluent from septic tank, soakage well of any capacity by sewer jetting cum suction machine vehicle / honey sucker machine vehicle from any location and disposal to suitable place i.e. authorised civil location with and including taking off & re-fixing manholes covers etc complete all as specified and directed by Engr-in-Charge. Note : 1. The Contractor / site supervisor will attend the complaint cell of AGE B&R-III to receive the complaint slips daily at 0900hrs to carry out the complaints within 48 hrs from receipt of compalints slip and completion report will be submitted to concerned JE / AGE before 48hrs as per complaint slip time.2. If Contractor is to be failed to carry out to completion the jobs within the stipulated time period, the recovery will be chargeable at the rate of Rs. 825.00 per Cum for every day. |
| 5 | M&L for cleaning of septic tank of any capacity and depth including inlet / outlet chamber after mixing of contaminated waste effluent and sludge etc of septic tank by mixing machine to change the state of solid / semi solid sludge to liquid state by using extra water provided by the Contractor if required and getting out through sewer jetting cum suction machine vehicle / Honey sucker machine vehicle from any location and disposal to suitable place i.e. authorised civil location with and including taking off & re-fixing manholes covers etc complete all as specified and directed by Engr-in-Charge. Note : 1. The Contractor / site supervisor will attend the complaint cell of AGE B&R-III to receive the complaint slips daily at 0900hrs to carry out the complaints within 48 hrs from receipt of compalints slip and completion report will be submitted to concerned JE / AGE before 48hrs as per complaint slip time.2. If Contractor is to be failed to carry out to completion the jobs within the stipulated time period, the recovery will be chargeable at the rate of Rs. 1150.00 per Cum for every day. |
| 6 | M&L for excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc or for shaft,wells,cesspits,manholes,sewage line,pier holes n.exc 10 Sqm on plan and n. exc 1.5m in depth and getting out in any type of soil compete all as specified.. |
| 7 | M&L PCC (1:3:6) type C2 in foundations, filling and mass concrete to sub base of manholes etc alongwith demolition complete all as specified |
| 8 | M&L for brick work in repairs with sub class ‘B’ old size bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:4 incl demolition of brick work in any mortar complete all as specified and directed. |
| 9 | M&L PCC (1:2:4) type B1 as in coping, benching to manholes complete all as specified |
| 10 | M&L Rendering 10mm thick in CM (1:4) mixed with liquid WPC as per Manufactorer~s instruction to concrete surface finished even and smooth w/o using extra cement. |
| 11 | Returning, filling in soil, including spreading,levelling ,watering and well ramming in layers n.exc 25 cm thick each layer as in soil all as specified. |
| 12 | Removal of excavated incl material (Soil) to a distance n.exc 50M and depositing where directed at a level not exceeding 1.50M above the starting point. |
| 13 | Dismantling of cast iron, PVC, SWG Pipe or asbestos pipe set in any motrar in connections of any dia. |
| 14 | S&F PVC (SWR) pipe double socketed, in any length with rubber ring joints, laid in tranches or in floors or wall (110mm bore) all as specified. |
| 15 | S&F PVC (SWR) pipe double socketed, in any length with rubber ring joints, laid in tranches or in floors or wall (75mm bore) all as specified. |
| 16 | S&F PVC (SWR) bend 110mm dia any radius all as specified. |
| 17 | S&F PVC (SWR) bend 75mm dia any radius all as specified. |
| 18 | S&F PVC (SWR) branch piece, single (single Y) equal or unequal 75 mm dia all as specified |
| 19 | S&F PVC (SWR) junction single (single T) equal or unequal (75/ 110mm dia) all as specified. |
| 20 | S&F PVC (SWR) vent cowl 75mm dia all as specified. |
| 21 | S&F in repair rotational moulded HDPE water storage tanks (cylindrical vertical with closed top) of 500 litres capacity, ISI marked, double layered hoisted and fixed in position including connecting up pipes including 20mm bore brass body ball valves, high pressure and 25mm bore gun metal gate or globe valve with iron wheel head screwed both ends for iron pipe complete all as specified. |
| 22 | S&F Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. |
| 23 | S & F in repair 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 24 | Demolition of cement concrete ground floor unreinforced and paving n.exc 15cm thickness (below or above ground level) incl removal of out side MoD land all as specified and directed |
| 25 | Dismantling of stone slabs a laid in dry and tiles of any description or thickness in floors and incl removal of out side MoD land and all complete all as specified. |
| 26 | M&L for PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in sub bases, 75 mm thick finished even & rough to receive finishing layer, etc. complete. |
| 27 | M&L Chequered cement concrete tiles of Glossy finish of size 20cmx20cmx 25mm thick set jointed and pointed in neat cement slurry in floorswith grey cement and pigment including 15mm thick screed bed or beding layer in cement mortor 1:6 complete complete all as specified and directed by Engr-in-Charge. |
| 28 | M & L for laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour,design & pattern as in footparth, parks,lawns, drive ways or light traffic parking etc.,of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. |
| 29 | Dismantling structural steel work including doors, gates but excluding framed truss etc. |
| 30 | S & F for Framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled and welding for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing (FE 410W E-250 Quality A Grade) complete all as specified and directed. |
| 31 | M & L for preparation of new steel surfaces of any description over 10cm width or girth and painting with two coats of synthetic enamel paint over a coat of red oxide primer completed all as specified and directed. |
| 32 | Dismantling plain or corrugated steel sheeting, any guage, thickness complete all as specified and directed |
| 33 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steelsheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all specified and directed. |
| 34 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all specified and directed. |
| 35 | Taking down cement plaster or brick or stone walls etc, including raking out joints, hacking for key, scrubbing down with water all as specified and directed |
| 36 | M&L 15mm thick rendering over other than fair faces of brick work or concrete sufaces in CM 1:6 including finishing even and smooth without using extra cement all as specified and directed |
| 37 | M&L 15mm thick rendering on fair faces of brick work or concrete sufaces in CM 1:4 including finishing even and smooth without using extra cement and by mixing WPC @ 3% of Cement Constant complete all as specified and directed. Note WPC used will be measured and paid separately. |
| 38 | Supply only water proofing compound, complete all as specified and directed. |
| 39 | M&L preparation of plastered or uplastered new surfaces on walls and applying two coats of oil bond distemper on walls over 3mm thick of wall putty all as specified and directed. |
| 40 | M&L preparation of plastered or uplastered new surfaces on walls and applying two coats cement base paint on walls over a coat of primer all as specified and directed. |
| 41 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but notbacking), removing serviceable tiles to store and rubbish off the premises as specified and directed. |
| 42 | M&L for 25mm thick Cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate in leveling course, benching etc, finished even & rough to receive cement mortar screed bed complete. |
| 43 | M & L Glazed ceramic coloured tiles in vertical surface 450x 300x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match) complete all as specified. |
| 44 | M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick area of each tile not exceeding 0.18 in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed or bedding layer in CM (1:6) complete. |
| 45 | Dismantling wall and ceiling board (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed. |
| 46 | S & F for 5mm thick PVC sheet fillet of width 35mm for all paneling inclusive of fixing on to wall to make PVC frame as per specification and drawing completed all as specified and directed. |
| 47 | S & F for Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawings completed all as specified and directed. |
| 48 | M&L Granite (of any type) tiles 20mm thick machine cut, bedded & jointed with grey cement slurry & pointed with white cement with admixure of pigment to match the shade of granite stone including cutting & polishing over 15mm thick screed in CM(1:4)complete all as specified and directed. |
| 49 | M&L 20mm thick Granite (of any type) tiles machine cut in skirting/dado over 15mm thick plater in CM (1:6) & jointed witht grey cement slurry & pointed with white cement with admixture of pigment to match the shade of granite stone including cutting & polishing |
| 50 | S&F in repair vitreous china wash down water closet (pedestal pattern) pan, white(excluding fixing bolts, flushing cistern and flush pipe) etc.. complete all as specified and as directed. |
| 51 | S & F plastic seat cover white closed pattern with flat bottom and cover and mild CP aluminium hinging device all as specified and directed. |
| 52 | S & F in repair PVC 10 ltrs capacity low level flushing cistern complete set including flush pipe all as specified and directed. |
| 53 | S & F in repair vitreous china wash basin, white flat back size 550x 400 mm incl. brackets ,cutting for pinning in ends of brackets as fixed all as specified and directed. |
| 54 | S & F in repairs PVC waste pipe, 32 mm dia for WHB or sink complete all as specified and as directed. |
| 55 | S & F health faucet (ABS body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 56 | S& F 600 x 450 mm bevelled edge mirror or alu/metal frame of selected quality glass mounted on 6 mm thick AC bldg board fixed with wooden plug with chromium plated brass screw and cup washer all as specified and directed. |
| 57 | S&F A shower arm 15mm size, 195mm long with bend of 45 degreee with flange of PTMT any colour. (min. weight 40 gms) |
| 58 | S&F in repair brass chromium plated wall mixer for mixing Hot & cold water, high pressure, screwed down for 15 mm bore iron pipe fixed complete all as specified and directed. |
| 59 | S&F in repair brass chromium plated pillar mixer for mixing Hot & cold water, high pressure, screwed down for 15 mm bore iron pipe fixed complete all as specified and directed. |
| 60 | S&F MS Grating doom 100 mm dia (min. weight 25 gms) |
| 61 | S & F soap dish brass chromium plated fixed to wall with brass chormium plated screw and plastic plug etc. completed all as specified and directed. |
| 62 | S & F in repair 15mm bib tap chromium plated with crutch or butterfly handle screwed for iron pipe complete all as specified and directed. |
| 63 | S & F in repair 15mm stop valve angular type cromium plated fancy type , screwed down , high pressure, with crutch or butterfly handles complete all as specified and directed. |
| 64 | S & F in repair 15mm 2 in one angle cock angular type cromium plated fancy type , screwed down , high pressure, with crutch or butterfly handles complete all as specified and directed. |
| 65 | S & F PVC connection pipe 15mm size with PTMT nuts of length 600mm all as specified and directed. |
| 66 | S&F Towel rail 600mm long of PTMT fixed with & including CP brass screws & wooden/plastic cleats (min. weight 190gms) |
| 67 | M&L filling of dry sand under and around LT cable to provide sand cushioing and in sub stn ducts/trenches complete all as directed. |
| 68 | Supply and lay brick of conventional size 230x110x75mm locallly available as protection of cable in trenches complete all as specifed and as directed by Engineer in charge |
| 69 | M&L PCC 1:4:8 type D2 using graded stone aggregate for foundationof pole complete all as directed |
| 70 | M&L PCC 1:3:6 type C2 using 40mm graded stone aggregate for filling of pole &stay complete all as specified and directed |
| 71 | M&L PCC 1:2:4 type B2 using 20mm graded stone aggregate for coping of pole complete all as Specified and as directed |
| 72 | Taking out old UNSV and Supply, laying, jointing and Replacement of of XLPE insulated, armoured, heavy duty LT under ground cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area for following sizes, including taking down old, complete, all as specified and directed :- |
| 73 | (a) 25 Sqmm 4.0 Core. |
| 74 | Supply and installation in Replacement of off load change over switch in sheet metal enclosure of capacity 100 Amps FP, 415 Vac, 50 Hz, complete all as specified and directed. |
| 75 | Taking down existng unserviceable street/security light fittings HPSV/HPMV/MH/Tube light fittinsgs of any capacity any type from pole/wall after disconnection the connecting wires and supply and fixing in replacement of LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete withIP 65/66 protection complete. |
| 76 | Supply and fixing in replacement of 120 W Flood Light of die cast aluminium body ,IP-66 inculding all accessories are required complete all as specified and as directed |
| 77 | Supply and fixing in replacement of LED driver for suitable for 25 Watts to 60 Watts complete all as specified and directed by Engr-in-Charge. |
| 78 | S&F in replacement of street light terminal boxes made out with SMC material, shock and dust proof of inside size 295x195x100 mm as per IS and including 100 amp TPN busbar fixed on insulators, 01 No 06 amp SP MCB, earth termination with nuts and bolts and including 02 sets of flat iron 25x6 mm clamps of suitable size with nuts,bolts and washers complete all as specified and as directed. |
| 79 | Taking down and replacement of existing unserviceable street light fitting bracket with new brackets made out of 40mm bore GI pipe, light grade, tubing bend to shape, 1.2 metre long, fixed to pole/wall with and including two sets of clamps made out of flat iron of size 50 x 6 mm with bolts, nuts and washers, complete, all as specified and directed. |
| 80 | Taking down and replacement of existing unserviceable clamps with new clamps made out of 40x6 mm bending to shape, drilling holes for bolts suitable for fixing GI pipe bracket to steel pole, made in two halves, including nuts, bolts, washers and painting with two coats of aluminium paint over a coat of red oxide primer, complete, all as specified and directed. |
| 81 | Taking out old unservicable PCC/steel tubular pole 9 mtrs long and supply and fixing steel tubular swaged poles with iron cast base plate ,final taper plug,bolts,nuts,screws as specified type 410 SP-31 (9.0 mtr Long) and erecting in position all as specified with shifting of conductors and insulators including painting the exposed portion with two coats of aluminium paint over a coat of red oxide primer and internally through out plus embedded portion with two coat black bituminous paint coat over a coat of red oxide primer with and including marking of pole number with black paint in yellow circle ,complete,all as specified and directed |
| 82 | M&L painting steel tubular pole 9 mtr long alongwith bends with two coats of aluminium paint over a coat of red oxide primer and internally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer with and including marking of pole number with black paint in yellow circle ,complete ,all as specified and directed. |
| 83 | Material & labour for point wiring complete with single core 1.5 Sqmm (nominal area) PVC insulated multistranded, copper conductor cable (FRLSH) drawn through and including PVC casing & caping and accessories on wall & surface/ceiling complete, terminated in and including PVC gang box fixed with nickel polished screws with washers, earth continuity PVC cable(FRLSH), copper conductor 1.5 Sqmm (nominal area) stranded with green insulation earth wire connected with earth dolly One light point / fan point / bell push point controlled by one way switch 5 Amprs and/or through regulator complete all as specified and directed. complete all as specified. |
| 84 | Supply and fixing in Replacement of Switch piano, flush type 5 Amps, 240 V One Way complete all as specified and directed. |
| 85 | Supply and fixing in Replacement of LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light completewith driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 86 | Supply and laying pipe galvanized, “light grade” of size 50 MM to be used on road crossing/on pole/ culverts for laying of cable complete all as directed by Engr-in-Charge |
| 87 | S&Fin Replacement of 1.5 sqmm 3 core pvc insulated flexible copper conductor wire from street light terminal box to fittings of required length drawn through and including PVC conduit of suitable size or as indicated and directed. |
| 88 | S&F in Replacement of MCB SP 5/6 amp, 'C' curve, 10 KA, 240V complete inside existing postion of street light terminal boxes including taking down old unserviceable all as specified and as directed. |
| 89 | S&F in Replacement of new generatiion energy saving, enviornment friendly long life LED bldg security light fitting of 24/25W made up of pressure die cast aluminium housing with high efficient LED with IP66 and impact resistance of IK07 and including 43 mm dia mounting bracket bend or weld to shape and length as required or as directed by Engr-in-charge complete. |
| 90 | M&L for Earthing in repair complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate notless'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion |
| 91 | Notes :- Amount of Credit Schedule for Schedule 'A' Part-ll shall be deducted from total quoted amount of BOQ to arrive at the contract sum. Please Enable Macros to View BoQ information |