| 1 | Excavation in trenches in soft/loose soil not exceeding 1.5 m wide and not exceeding 1.5m in depth and getting out for taking out/laying of GI pipe of any size. |
| 2 | Returning, filling icluding , spreading, leveling, watering and well ramming in layers not exceeding 25 cm |
| 3 | Removing excavated materia;s to distance not excedding 50m and deposting where directed as level not exceeding 1.5m above the starting point. |
| 4 | Taking out/taking down old unserviceable damaged GI/PPR pipe of following sizes from excavated trenches including removing of fittings all as directed for necessary replacement /relaying serviceable GI pipe all as directed by Engineer in Charge. |
| 5 | (a) 100 mm dia |
| 6 | (b) 80 mm dia |
| 7 | (c) 50 mm dia |
| 8 | (d) 40 mm dia |
| 9 | (e) 25 mm dia |
| 10 | (f) 20 mm dia |
| 11 | (g) 15 mm dia |
| 12 | Relaying only of GI pipe after removal of scalling, cleaning and flushing etc including supply and fixing of new fittings of following sizes any grade in trenches and testing complete all as specified and directed by Engr-in- Charge. |
| 13 | (a) 100 mm dia |
| 14 | (b) 80 mm dia |
| 15 | (c) 50 mm dia |
| 16 | (d) 40 mm dia |
| 17 | (e) 25 mm dia |
| 18 | (f) 20 mm dia |
| 19 | (g) 15 mm dia |
| 20 | Refixing only of GI pipe of following sizes in short lenth (less than 03 mtr) any grade in wall,floor or in ceiling and testing including supply and fixing of new fittings complete all as specified and directed by Engr-in- Charge. |
| 21 | (a) 50 mm dia |
| 22 | (b) 40 mm dia |
| 23 | (c) 25 mm dia |
| 24 | (d) 20 mm dia |
| 25 | (e) 15 mm dia |
| 26 | Supply & Laying only of GI pipe after removal of scalling, cleaning and flushing etc including supply and fixing of new fittings of following sizes any grade in trenches and testing complete all as specified and directed by Engr-in- Charge. |
| 27 | (a) 100 mm dia |
| 28 | (b) 80 mm dia |
| 29 | (c) 50 mm dia |
| 30 | (d) 40 mm dia |
| 31 | (e) 25 mm dia |
| 32 | (f) 20 mm dia |
| 33 | (g) 15 mm dia |
| 34 | Repair/maint of water leakage from GI/PPR pipe joint in ground and open carefully the joint portion of the pipe line duly excavated the treach or along the wall of multy story bldgs by providing necessary ladder and opening existing fittings for repair/replacement and provision of new GI/PPR fittings if required to make the joint 100% water leak proof including returning, filling and ramming the excavated materials or fixing with wall by clamps after satisfactory, joint/leak chacking all as directed for following bore of GI/PPR pipe line :- |
| 35 | (a) 80 mm bore pipe line. |
| 36 | (b) 50 mm bore pipe line. |
| 37 | (c) 40 mm bore pipe line. |
| 38 | (d) 25 mm bore pipe line. |
| 39 | (e) 20 mm bore pipe line. |
| 40 | (f) 15 mm bore pipe line. |
| 41 | Supply and Laying of PPR pipes 3- layer SDR 7.4 of outer diameter of pipes as following UV stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply all PPR plain & brass threaded polypropylene random fittings laid in trenches including fittings and testing complete all as specified and directed by Engr-in- Charge. |
| 42 | (a) 20 mm dia. |
| 43 | (b) 25 mm dia. |
| 44 | (c) 32 mm dia. |
| 45 | (d) 50 mm dia. |
| 46 | (e) 63 mm dia. |
| 47 | (f) 90 mm dia. |
| 48 | M&L, Construction of Brick Masonry valve chamber of size 600x600x600mm (Internal dimensions) with PCC 1:4:8 foundation 150mm thick, brick work built in CM 1:6, PCC 1:3:6 coping 50mm thick, plastering 15mm thick in CM 1:6 to all internal and exposed surfaces including excavation earthwork in hard/dense soil, MS sheet cover 4mm thick and MS equal angle iron 50mmx50mmx6mm frame as per existing size with locking arrangement embedded in PCC suitable for 25/40/50mm gate valve and painting to MS cover with two coats of synthetic enamel paint over one coat of red oxide primer etc complete all per Drg. No HQ/136/TD/96 V and ground requirement including dismantling old/damaged valve pits. |
| 49 | Making connection of PPR distribution branch with PPR main of sizes 16 mm to 40 mm by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed. |
| 50 | Making connection of PPR distribution branch with PPR main of sizes 50 mm to 75 mm by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed. |
| 51 | Taking out unserviceable Gate valves from water pipe line for necessary replacement all as directed for valve size 15mm to 32mm |
| 52 | Taking out unserviceable Gate valves from water pipe line for necessary replacement all as directed for valve size 40mm to 80mm. |
| 53 | Supply and fixing gun metal gate valve of size 15mm dia including connection and testing complete all as directed. |
| 54 | Supply and fixing gun metal gate valve of size 20mm dia including connection and testing complete all as directed. |
| 55 | Supply and fixing gun metal gate valve of size 25mm dia including connection and testing complete all as directed. Make- SCUD/Zoloto / Anchor / Jindal / Leader. |
| 56 | Supply and fixing gun metal gate valve of size 40mm dia including connection and testing complete all as directed. Make-Scud/Zoloto / Anchor / Jindal / Leader. |
| 57 | Supply and fixing gun metal valve of size 50mm dia with iron wheel including iron wheel head screwed both ends for iron pipe including taking out of existing old one |
| 58 | Supply and fixing gun metal valve of size 80mm dia with iron wheel including iron wheel head screwed both ends for iron pipe including taking out of existing old one. |
| 59 | Supply and fixing PPR gate valve (brass insert) of size 20 mm dia including connection and testing complete all as directed. |
| 60 | Supply and fixing PPR gate valve (brass insert) of size 25 mm dia including connection and testing complete all as directed. |
| 61 | Supply and fixing PPR gate valve (brass insert) of size 32 mm dia including connection and testing complete all as directed. |
| 62 | Supply and fixing PPR gate valve (brass insert) of size 50 mm dia including connection and testing complete all as directed. |
| 63 | Supply and fixing PPR gate valve (brass insert) of size 63 mm dia including connection and testing complete all as directed. |
| 64 | S&F GI Flat strip clamps of size 25mm x 3mm duly bended as per the size of GI tubing and site condition,drilled all as directed by Engineer in Charge. |
| 65 | Supply and fixing of heavy rust proof passivated bolts made of steel of size 8 mm dia 75 mm long including necessary drilling on wall for fixing of steel frame all as directed by Engr in Charge. |
| 66 | Supply and fixing plug type PVC bib taps, screwed for iron pipe and fixed complete all as specified and directed. |
| 67 | M&L Lagging on pipes of internal dia 15 mm, used in external water supply or plumbing all round with, 40mm thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842, provided with chicken mesh wire netting 25 gauze 20mm mesh and finally covering with plaster of pairs including taking down old, complete, all as specified and directed. |
| 68 | All as per item No. 29 above but 20 mm bore tubing. |
| 69 | All as per item No. 29 above but 25 mm bore tubing. |
| 70 | All as per item No. 29 above but 40mm bore tubing. |
| 71 | All as per item No. 29 above but 40mm thick bonded and for 50mm bore tubing. |
| 72 | All as per item No. 29 above but GI/CI pipe of 40mm thick bonded and for 80mm bore tubing. |
| 73 | All as per item No. 29 above but GI/CI pipe of 40mm thick bonded and for 100mm bore tubing. |
| 74 | All as per item No. 29 above but DI/CI pipe of 40mm thick bonded and for 150mm bore tubing. |
| 75 | Construction/maintenance of old existing Valve pit chamber of size 90cm x 90cm x 90cm internal dimension brick/stone construction including all excavation and earth work in any type of soil, returning, filling in disposal of surplus soil to a distance not exc 50m and depositing were directed, PCC foundation of the mix (1:2:4), type D-2, brick masonry including plastering, rendering 12mm thick in cement mortar (1:4) internally finished even and fair and flush pointing externally as the work proceeds in same mortar and suitable size angle frame with mild steel angle iron 40X40x6mm, MS sheet cover 3.15mm thick with handle and locking arrangements and painting all steel surfaces with two coat of synethic enamelled paint over a coat of red oxide primer and painting all the MS embeded in PCC with two coats of black bitumenous paint as approved, complete all as specified and directed. |
| 76 | Taking up cast iron water main (incl all fittings) with spigot & socket ends/flanged ends incl disconnection of pipes & fittings complete for the following langth :- |
| 77 | (a) 80 mm bore |
| 78 | (b) 100 mm bore |
| 79 | (c) 150 mm bore |
| 80 | Supply & Laying cast iron pipes with spigot and socket end or flenged centrifugally cast, class LA, in any length and laid in trenches for the following size of pipes. (Note : All CI special/fittings shall be measured and seperately under respective items) |
| 81 | (a) 80 mm bore |
| 82 | (b) 100 mm bore |
| 83 | (c) 150 mm bore |
| 84 | M&L fixing of CI fittings/specials like bend (any type radius and angle), taper any type (straight, bends, increasing, decreasing or double socket etc) Tee pices single branch 'Y' junction, double branch cross (all socket or socket and spigot) collars caps and plugs etc upto size 150mm |
| 85 | M&L for joint for flange CI pipe with rubber or fiber board gasket for the following size of pipes with necessary nut, bolts, washers etc including dismantling complete all as specified and directrd by Engr-in-Charge. |
| 86 | (a) 80 mm bore |
| 87 | (b) 100 mm bore |
| 88 | (c) 150 mm bore |
| 89 | M&L for joints for spigot and socket CI pipe with Run lead joints including dismantling for the following size of pipes :- |
| 90 | (a) 80 mm bore |
| 91 | (b) 100 mm bore |
| 92 | (c) 150 mm bore |
| 93 | Repair/maint of water leakage from CI/DI pipe joint in ground and open carefully the joint portion of the pipe line duly excavated the treach and burning out the defective run lead joint in existing of CI pipe/fitting and provision of new lead joint in site using the retrived lead as obtaining from burning out of joint and adding of fresh lead if required to make the joint 100% water leak proof including returning, filling and ramming the excavated materials after satisfactory, joint/leak chacking all as directed for following bore of CI/DI pipe line :- |
| 94 | (a) 150 mm bore pipe line. |
| 95 | (b) 100 mm bore pipe line. |
| 96 | (c) 80 mm bore pipe line. |
| 97 | S&F cast iron sluic valve with both end flanged with iron wheel handle for clockwise closing brass spindle heavy duty PN-1.6 class. Conforming to IS-14846/2000 including gaskit joint nut, bolts & washers all as requirement of site incl dismentling and taking out existing unserviceable sluice valves for the following size :- |
| 98 | (a) 80 mm bore |
| 99 | (b) 100 mm bore |
| 100 | (c) 150 mm bore |
| 101 | M&L for fabrication and fixing of brass spindle for sluice valve matching with existing make complete with coller neack nuts all as per existing type of sluice valves for the following size including dismentling old worn-out spindle (Note : Brass spindle shall be fabricated from solid round bar having dia not less than the dia of the largest section of the spindle and not using anyriveting for expended coller of the spindle or by casting and machining to make the spindle a single piece) |
| 102 | (a) 150 mm bore pipe line. |
| 103 | (b) 100 mm bore pipe line. |
| 104 | S&F cast iron air release valve with double orifice 80 mm dia suitable for installation in upto 150 mm dia CI/DI pipe line incl nuts, bolts and gasket joint all as required complete including taking out unserviceable air release valves, conforming to IS 14845/2000 complete . |
| 105 | S&F cast iron non return valves conforming to IS-5312 with Gun metal seating single door type gaskit joints. Bolts/nuts etc including taking out unserviceable non return valves, all as required for the following :- |
| 106 | i) 150 mm bore pipe line. |
| 107 | ii) 100 mm bore pipe line. |
| 108 | iii) 80 mm bore pipe line. |
| 109 | Relaying of CI pipe line incl connection/jointing as obtaining against item No. 38 for the following size of pipes ( Note : Jointing & CI fittings shall be measured and paid separately ) |
| 110 | (a) 80 mm bore |
| 111 | (b) 100 mm bore |
| 112 | (c) 150 mm bore |
| 113 | Supply and fixing of nut, bollts and washers of any size for fixing of gasket joint in any size of pipes complete all as specified and directed. |
| 114 | Supply and fixing in replacement Direct On Line starter for 3 to 7.5 HP submersible pump 3 Phase 415 volts, as per existing complete all as specified and directed. |
| 115 | Disconnecting unservicable change over switch of any type as per site requirement and supply & fixing and connecting off load change over switch 4 pole 200 Amp 440 volts conforming to relevant IS including all connecting and jointing material complere, complete all as specified and directed. |
| 116 | Supply and laying rubber matting electrical grade of size 2m x1m x 10mm ISI marked, laid in front of the LT panel all as specified and directed |
| 117 | Supply and fixing in replacement single phase preventor, complete all as specified and directed.Make- AE/L&T/ABB |
| 118 | Supply and fix in replacement foot valve flanged end drilled type including nuts, bolts and jointing materials complete all as specified as per IS -4038. of following sizes :- |
| 119 | (a) 150 mm dia |
| 120 | (b) 100 mm dia |
| 121 | (c) 80 mm dia |
| 122 | Replacement of Fully Automatic Star Delta Starter suitable for 60 HP Centrifugal pump Sets 415 volt, 3 Phase, 50 Hz, including single phase Preventer complete. MAKE-Siemens CAT PT NO-3TE 0497-2A or equivelant to Havells /L&T |
| 123 | Cleaning of Overhead reservoir by draining out water below supply level, removing all internal sludge by washing. Cleaning the surface of the reservoir using wire brushes and other scraping tools to remove dirt and scale to make it free from deposits. Washing the reservoir with high pressure compressor nozzle thoroughly and removing dirty water from the tank to make it clean. Disinfecting the sump surface using disinfectent complete all as specified and directed for 50000 gallons capacity (Note:- The work of cleaning and disinfection will be carried out by expert in the field of the work. The work is to be carried out in such a way that the water supply is not disrupted.) |
| 124 | All as per item No. 56 above but 100000 gallons capacity |
| 125 | Cleaning of underground/semi underground round/rectangular water sump by pumping out water below suction level, removing all internal deposited sludge by non clogging submersible pump, cleaning the surface of the sump using wire brushes and other scraping tools to remove dirt and scales to make it free from all deposits, washing the sump with high pressure compressor nozzle thoroughly and removing dirty water from the pump to make it clean including repair to the internal surfaces by plastering with cement mortar 1:3,15mm thick and providing fillers at cracks to prevent any seepage of water including disinfecting the sump surfaces, complete, Painting one coat of anti bacteria water proof paint all as specified and directed of 50000 gallons capacity. (Note:- the work of cleaning and disinfection will be carried out by expert in the field of the work. the work will be carried out in such a way that the water supply is not interupted; necessary bypass arrangement to be done). |
| 126 | All as per item No. 58 above but 100000 gallons capacity |
| 127 | All as per item No. 58 above but 200000 gallons capacity |
| 128 | All as per item No. 58 above but 25000 gallons capacity |
| 129 | Bleaching powder of superior quality with latest lot and test certificate from authorized laboratory with min 30% active chlorine (in 25 Kg bags). Make: Nishat/Shriram/Modi. |
| 130 | Granular chlorine (60% of chlorine conten) disinfectant superior quality for mixing with drinking water for water treatment, complete all as specified and directed. make as approved by GE. Please Enable Macros to View BoQ information |
| 131 | Granular chlorine (60% of chlorine conten) disinfectant superior quality for mixing with drinking water for water treatment, complete all as specified and directed. make as approved by GE. Please Enable Macros to View BoQ information |