| 1 | Dismanting post of struts (wood,steel or RCC) any section,including taking out embedded portion in natural ground and making good the disturbed ground complete all as specified and as directed. |
| 2 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in & raming earth/ broken rubble mixed with earth around, in layers n. exc. 25cm, watering, & removing surplus soil to a distance n exc 50m & making good surface in soft/loose soil. |
| 3 | M&L PCC in foundations, filling and mass-concrete type C2 (1:3:6) using 40 mm graded stone aggregate complete all as specified and as directed. |
| 4 | S&F in repair Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings & straining & fixing to any type of standard rails straining bolts, including, securing or tying at crossings with & provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and as directed. |
| 5 | Dismantling fencing wire mesh n.exe 4kg, any type and in any position & separating them the serviceable & unserviceable materials and removing the unserviceable wire mesh from work site as directed |
| 6 | Supply only Chain link MS galvanised fencing, any size or type complete all as specified and as directed. |
| 7 | Fixing only chain link fencing including line wire any mesh, size and type to any type of standards rails staining bolts etc including provision of binding wire complete all as specified and as directed |
| 8 | S&F Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled & countersunk for balusters running bars, for doors,balusters,nosing to steps including embeding in concrete & screwing etc. wind ties for roof including securing bolts; posts & struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., & similar work conforming to Fe 290-0 Gde E-165 complete all as specified and as directed. |
| 9 | S&F Mild steel screw bolts (machine made) with hexagonal /square heads at one end & screwed the other/ screwed both ends, each screwed end to be fitted with washers & one hexagonal or square nut, length of bolt exc 5cm but n exc 10cm long dia of shank 11 to 15 mm complete all as specified and as directed. |
| 10 | M&L Mild steel TMT bars 10mm dia & over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specified and as directed. |
| 11 | Applying two coats of synthetic enamel paint on steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of new surface & applying one coat of red oxide, zinc chrome complete all as specified and as directed. |
| 12 | Preparation of new or previously untreated steel surfaces of any description n.exc 10 cm width or grith,not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide of zinc chrome complete all as specified and as directed. |
| 13 | Taking down cement plaster on brick or stone wall etc including racking out joints hacking for key scrubbing down with water etc complete all as specified and as directed.. |
| 14 | M&L for rendering 15 mm thick, cement plaster in cement mortar (1:4) mixed with liquid water proofing compound as per manufacturer instructions on fair faces of brick work or concrete surface even & smooth without using extra cement complete all as specified and as directed. Note:- Liquid water proofing comound shall be measured & paid separately |
| 15 | Supply only liquid water proofing compound complete all as specified and as directed. |
| 16 | M&L for applying two coat of 100% acrylic exterior emulsion paint in camouflage pattern ( Three colour as approve by GE) over and including a coat of primer on newly plastered surfaces of wall including preparation of surfaces complete all as specified and as directed. |
| 17 | Demolition of cement concrete in ground floor and paving n.exc 15 cm thickness (below or above ground level) complete all as directed. |
| 18 | M & L for 75 mm thick plain cement concrete type D2, 1:4:8 using 40 mm graded stone aggregate as in sub base complete all as specified and as directed. |
| 19 | M&L Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed & pointed in neat cement slurry in floors with grey cement & pigment over 15mm thick screed in CM(1:4) including dismantling of previous one complete all as specified and as directed. |
| 20 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc.,of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand incl dismantling of old tiles. |
| 21 | M&L Precast factory made kerrb stone any size and any shape type B0 (1:2:4) using 12.5 mm graded aggregate as in copings, kneelers, apex stones, bed plates, slightly rounded for chamfered angles and throating etc, complete all as pecified and as directed. |
| 22 | M&L PCC in lintels upto 1.5 m clear span, cills, steps; seismic & other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directed type B0 (1:2:4) using 12.5 mm graded aggregate complete all as specified and as directed. |
| 23 | Demolition of Brickwork or stone/boulder masonry, built in CM or cement lime mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework & precast concrete articles |
| 24 | M&L for Brickwork with fly ash modular bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and as directed. |
| 25 | M & L for Brickwork with fly ash modular bricks, straight or curved on plan to any radius, built in cement mortar 1:4 as in half brick thick walls complete as specified and directed. |
| 26 | M & L for rendering 15mm thick in cement plaster 1:4 on other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge |
| 27 | Demolition of cement concrete(unreinforced) in any description any position not otherwise specifically provided for; complete all as directed. |
| 28 | M&L endura paving coloured tiles of technocommercial equivalent of size 300mmx300mmx10mm set and jointed in neat cement slurry pointed with white or coloured cement laid over and incl 15mm thick screed bed built in CM (1:4) after demolition old floor hearth or wall tiling complete all as specified & directed |
| 29 | Dismantling floor hearth or wall tiling including cement mortar bedding but not backing, removing serviceable tiles to store and rubbish off the premises complete and all as specified. |
| 30 | M&L for glazed black ceramic tiles in vertical surfaces such as skirting /dados and riser to steps area of tiles 450x300x7mm thick set and jointed and pointing in white or coloured cement to match over 10 mm thick plaster in CM 1:4 complete all as specified and directed. |
| 31 | M & L for brickwork with sub-class `B` bricks, straight or curved on planexc 6m mean radius built in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge |
| 32 | Dismantling structural steel work including doors, gates but excluding framedtruss etc complete all as specified and as directed by the Engineer-in-Charge |
| 33 | S&F for rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing qyality one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor’s workshop before fabrication confirming to Gde Fe410 complete all as specified and as directed. |
| 34 | M & L for preparation of new or previously untreated surfaces of brick, plaster, cement concrete or stone over 10cm girth or width, not other wise described and applying two cats of synthetic enamel paints complete all as specified and as directed by the Engineer-in-Charge |
| 35 | Preparation of new surfaces of steel any description over 10 cm width or girth and applying two coats of synthetic enamel paint all as specified. |
| 36 | S&F for wooden flooring of AC4 class fixed to wooden or concrete surface includig preparing the surface to receive wooden flooring includinh dismantling existing flooring complete all as specified and as directed by Engineer in Charge. |
| 37 | Notes :- Amount of Credit Schedule for Schedule 'A' Part-ll shall be deducted from total quoted amount of BOQ to arrive at the contract sum. Please Enable Macros to View BoQ information |