| 1 | M&L for preparation of NEW surfaces of steel any description over 10 cm width or girth by scrubbing down, removing loose dirt or dust and applying two coats of synthetic enamel paint over prepared old surfaces of steel complete all as specified. |
| 2 | M&L for preparation of NEW wooden surfaces of any description not other wise decribed over 10 cm width or girth by scrubbing down, removing loose dirt or dust and applying two coats of synthetic enamel paint over prepared old wooden surfaces complete all as specified. |
| 3 | M & L for dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by the Engineer-in-Charge |
| 4 | M&L for Non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tiles exc 0.11 but not exc 0.18 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or colour cement to match laid over and including 15mm cement screed bed in CM (1:4) complete all as specified. |
| 5 | M&L for Non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) as in skirting etc cut from tiles exc 0.11 but not exc 0.18 Sqm set and jointed in neat cement slurry and pointed in white or colour cement to match laid over and including 10mm thick rendering in CM (1:4) complete all as specified. |
| 6 | M&L for Non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tiles exc 0.18 but not exc 0.38 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or colour cement to match laid over and including 15mm cement screed bed in CM (1:4) complete all as specified. |
| 7 | M&L for Non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) as in skirting cut from tiles of size exc 0.18 but not exc 0.38 Sqm etc set and jointed in neat cement slurry and pointed in white or colour cement to match laid over and including 10mm thick rendering in CM (1:4) complete all as specified. |
| 8 | M&L for glazed coloured ceramic tiles in vertical surfaces such as skirting /dados and riser to steps area of tiles 450x300x7mm thick set and jointed and pointing in white or coloured cement to match over 10 mm thick plaster in CM 1:4 complete all as specified and directed. |
| 9 | Demolition of concrete in ground floors and pavings n exe 15 cm thickness (below or above ground level) complete all as specified and as directed by the Engineer-in-Charge. |
| 10 | M & L for 75mm thick cement concrete type D-2 1:4:8 using 40mm graded aggregate complete all as specified and as directed by the Engineer-in-Charge |
| 11 | M&L for providing cement concrete 1:2:4 Type B0 using 12.5 mm graded aggregate as in lintels upto 1.5m clear span,cills,steps; ceismic and other similar bands, plinth, string, lacing cources, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like incl weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed by the Engr-in-Charge. |
| 12 | M&L johnson endura paving coloured tiles of technocommercial equivalent of size 300mmx300mmx10mm set and jointed in neat cement slurry pointed with white or coloured cement laid over and incl 15mm thick screed bed built in CM (1:4) after demolition old floor hearth or wall tiling complete all as specified & directed |
| 13 | M & L for 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed by the Engineer-in-Charge |
| 14 | Refixing in same opening shutters of any description exc 1 sq. m and not exc 2 sq. m each complete all as specified and as directed by the Engineer-in-Charge |
| 15 | Dismantling Wall and ceiling boards (fibre pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified. |
| 16 | S & F 605mm x 605mm anodised aluminium snap grid frame work for false ceiling complete all as specified and as directed by the Engineer-in-Charge |
| 17 | S & F for Hangers 6mm dia GI (upto 1200mm length ) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fastener 12.5mm dia 40mm long complete all as specified |
| 18 | M & L for providing and fixing 12mm thick gypsum board in ceiling fixed with screw as per manufacturers instructions complete all as specified and as directed by the Engineer-in-Charge |
| 19 | M & L for 12mm thick medium density fibre board, exterior grade, fixed to timber framework with screws complete all as specified and as directed by the Engineer-in-Charge |
| 20 | Dismantling timber scantlings under 40 sq. cm in section, in any position in fillets, rails, posts, rafters , purlins, etc. under 40 sq. cm in section (Framed work) complete all as specified and as directed by the Engineer-in-Charge. |
| 21 | M & L for plain fillets, square, rectangular or triangular in section, and secured with nails or brads, using IInd class soft-wood clean sawn in sectional area exc 6 sq.cm and not exc 13 sq.cm complete all as specified and as directed by the Engineer-in-Charge |
| 22 | M & L for 4mm thick (3 ply) plywood, grade BWR, type BB, fixed with screws to timber frame work complete all as specified and as directed by the Engineer-in-Charge |
| 23 | S & F hollow PVC wall lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on as per specifications and drawing complete all as specified and as directed by the Engineer-in-Charge |
| 24 | Taking down shutters of any description n exc 1 sq. m each complete all as specified and as directed by the Engineer-in-Charge |
| 25 | Taking down shutters of any description exc 1 sq. m and not exc 2 sq. m each complete all as specified and as directed by the Engineer-in-Charge |
| 26 | Refixing in same opening shutters of any description exc 1 sq. m and not exc 2 sq. m each complete all as specified and as directed by the Engineer-in-Charge |
| 27 | Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sq. m each complete all as specified and as directed by the Engineer-in-Charge |
| 28 | Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc. 1.5 sq. m but not exc 4 sq. m each complete all as specified and as directed by the Engineer-in-Charge |
| 29 | S & F for rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing, quality confirming to GDE Fe410-S complete all as specified and as directed by the Engineer-in-Charge |
| 30 | S & F 30mm thick, 2nd class hardwood, plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with comercial face veneers; fitted to chowkats complete all as specified and as directed by the Engineer-in-Charge |
| 31 | S & F 30mm thick 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.20 (a); fitted to chowkats complete all as specified and as directed by the Engineer-in-Charge |
| 32 | S & F solid PVC door frame of size 50mm x 47mm made out of 5mm prelaminated PVC sheet, reinforced with M.S. square tube and fixing in opening as per specification & drawing complete all as specified and as directed by the Engineer-in-Charge |
| 33 | S & F Factory made solid panel pvc door shutter 30 mm thick (style) consisting of frame made out of M. S. tubes for top & bottom rails. M. S. frame shall be covered with heat moulded plain colour PVC `C` channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M. S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and as directed by the Engineer-in-Charge. |
| 34 | S & F anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed by the Engineer-in-Charge |
| 35 | M&L for ACP board for fixing in aluminium partition and doors complete all as specified and as directed. |
| 36 | M & L for sheet glass 3.0mm thick, ordinary quality and glazing with oil putty in square n exc 0.5 sq m in each pane complete all as specified and as directed by the Engineer-in-Charge |
| 37 | M & L for hacking out old broken glass exc 1.5 sq m (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed by the Engineer-in-Charge |
| 38 | S & F for galvanized mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staples complete all as specified and as directed by the Engineer-in-Charge. |
| 39 | S&F in repair galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanized wire staple complete all as specified |
| 40 | S & F 150mm aluminium handles, cast type, anodised complete all as specified and as directed by the Engineer-in-Charge |
| 41 | S & F 200mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed by the Engineer-in-Charge |
| 42 | Supply and fixing for ISI marked 300mm long aluminum alloy, anodized sliding bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloys to door shutter complete all as specified and as directed by the Engineer-in-Charge. |
| 43 | S & F butt hinges 100mm size, type B-21, extruded aluminium alloy with galvanised mild steel hinge pin, anodised |
| 44 | M & L for brickwork with subclass `B` bricks, in straight or curved on plan exc 6m mean radius, built in CM 1:6 complete incl demolition all as specified and as directed by the Engineer-in-Charge |
| 45 | S & F in repair mild steel powder coated wooden finish curtain rod 25mm dia fixed with decorative brackets & finials at the end etc complete all as specified. |
| 46 | Supply and fixing for ISI Marked 300mm long mild steel ordinary rat tail rod pattern springs for doors including roller and roller plate complete all as specified and as directed by the Engineer-in-Charge |
| 47 | Dewatering of contaminated/waste water from septic tank/sokage wells of any capacity and depth through pumping and disposal off the same through soil tanker out of MOD land distance not less than 3 KM complete all as specified and directed. |
| 48 | Cleaning of manholes not exceeding 1.5m in depth and by pumping or manually or by any means and the sludge/sludge water is to be disposed off in covered containers to a distance exc 2 KM outside the periphery of defence land including taking off and refixing manhole covers complete all as specified and directed. |
| 49 | Opening /Cleaning and making operational the blocked water closet (Indian/orrisa or English type)at any floor including cleaning of traps and CI drain pipe (any type and any position)from WC's/trap to manhole Cleaning and well flushing,pressure pumping , taking out all residues etc and removing the same to distance not exceeding 1000m, burried the same underground in low laying area and covering the same with earth including removal of surplus soil to a distance not exc 500m complete all as specified and directed.Note:-The complaint has to be rectified within defined time as given in complaint slip failing which penalty will be imposed as Rs100/- per complaint. |
| 50 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth in any type of soil for foundation, etc, or for shafts, wells, drain pipes n.exc 10sqm on plan and getting out, complete, all as specified and directed. |
| 51 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick, complete, all as specified and directed. |
| 52 | Removing surplus soil to a distance not exceeding 50m and deposited where directed at a level not exceeding 1.50m above the starting point, complete, all as specified and directed. |
| 53 | M&L for cement concrete 1:4:8 type D-2 (40mm graded aggregate) in foundation, filling and mass concrete complete all as specified and directed. |
| 54 | M&L Providing precast cement concrete type B1 using 20mm graded aggregate in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain face set in CM 1:4 complete with joint to match except block or slabs complete all as specified and as directed. |
| 55 | M & L for mild steel TMT bars ,10mm dia and over , cut to length , bent to shspe required incl cranking , bending spirally for hooping for coloumns , hooking ends andbionding with (annealed) not less than 0.90 mm dia all a specified and directed |
| 56 | Description all as per ser item No 54 above but 6 to 8mm dia all a specified and directed |
| 57 | Demolition of brick work or stone masonry in cement morter complete all as spd and directed. |
| 58 | Material & Labour for brick work with sub class `B’ bricks, straight on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed. |
| 59 | M & L for rendering 15mm thick in cement plaster 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge |
| 60 | M&L for taking down cement of cement lime plaster of any description on brick or stone walls etc incl raking out joints hacking for key scrubbing down with water etc complete all as specified and as directed by the Engineer-in-Charge. |
| 61 | M&L Concrete bed to drain pipes of bore 100 mm dia including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6, type C2, (using 40 mm graded stone aggregate) including necessary shuttering and supports ,complete all as specified and directed. Notes:- (i) Thickness of bed below of pipe-10cm. (ii) Width of bed-outer dia of pipe plus 30cm |
| 62 | Cutting into existing manholes for connecting new drains, making good to pipe 100 mm dia and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in PCC 1:2:4 type B-1.smooth finished and reforming benching as required complete,all as specified and directed. |
| 63 | S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or floors except pipes complete all as specified and as directed by the Engineer-in-Charge. |
| 64 | S & F 75mm bore PVC (SWR) bends any radius complete all as specified and as directed by the Engineer-in-Charge. |
| 65 | S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or floor including dismantling of cast iron or reinforced concrete, PVC(SWR) pipes ,joinetd in cement mortor and taking out of trenches complete all as specified and directed. |
| 66 | S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete,all as specified and directed. |
| 67 | S&F 110 mm bore PVC (SWR) pipes bends any radius complete all as specified and directed. |
| 68 | S&F in repairs viterous china squatting pan Orrisa pattern size 580 x 440mm white with \\"P\\" and \\"S\\" trap front or back inlet etc including connectipon to trap and to flishing to pipe , anti syphonage pipe etc incl provisioning of lime concrete complete all as specified. |
| 69 | S&F in repairs 10 ltr PVC valveless syphonic action type flushing cistern with brackets flush pipe etc complete including inlet ball valve float and handle including brackets of approved make including all connections & flush pipes for WC complete all as specified. |
| 70 | M & L for 15mm PVC connection wth PTMT nut length of 600mm complete all as specified and as directed by the Engineer-in-Charge |
| 71 | S&F in repair vitreous china wash down water closet pan ( pedestal pattern) white including connection to out going pipe and to flushing pipe and antysyphonic pipe etc including seat cover complete all as specified. |
| 72 | S&F in rep plastic water closet seat white closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinges device complete all as specified. |
| 73 | M & L for fixing `in repairs` 32mm dia flush pipes of polyethylene of low or high density of PVC for low level cistern to pedestal pan/orissa pan, including all joints including all joints and making good to the floor complete all as specified and as directed by the Engineer-in-Charge |
| 74 | S&F for Health faucet (ABS Body) mild steelchromium plated suitable for 15 mm diapipe with 1.25 metre long flexible tube andABS wall hook including makingconnections and fixed in position completein all respect as specified |
| 75 | S&F in repairs for Vitreous China bowl urinal flat back, size of 465mm x 355mm x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) including providing and fixing plugs,bedding urinals against wall in cement mortar 1:2, securing to plug with and including 60mm long brass scre etc complete all as specified and directed. |
| 76 | S&F bib taps 15mm dia fancy type brass Chromium Plated with long body screwed down for iron pipe and fixed IN REPAIRS complete all as specified. |
| 77 | S&F in repair for 15 mm dia stop valves fancy type ,chromium plated screwed down high pressure with crutch or butterfly handle complete all as specified. |
| 78 | M&L for 75mm bore PVC(SWR) multi floor trap , plain with grating incl jointing with solvent cement complete all as specified and as directed by the Engineer-in-Charge. |
| 79 | Notes :- Amount of Credit Schedule for Schedule 'A' Part-ll shall be deducted from total quoted amount of BOQ to arrive at the contract sum. Please Enable Macros to View BoQ information |