| 1 | Excavating in trenches n.exc 1.5m wide and n.exc 1.5m in depth in soft/loose soil for foundation, etc, or for shafts, wells, drain pipes n.exc 10sqm on plan and getting out, complete, all as specified and directed. |
| 2 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick, complete, all as specified and directed. |
| 3 | Removing surplus soil to a distance n.exc 50m and deposited where directed at a level not exceeding 1.50m above the starting point, complete, all as specified and directed. |
| 4 | Taking up or down steel tubing with connections for cleaning for refixing or removing to storeyard complete of bore 15mm, complete, all as specified and directed. |
| 5 | Description all as per ser item No. 4.00 above, but 20mm bore. |
| 6 | Description all as per ser item No. 4.00 above, but 25mm bore. |
| 7 | Description all as per ser item No. 4.00 above, but 40mm bore. |
| 8 | Description all as per ser item No. 4.00 above, but 50mm bore. |
| 9 | Description all as per ser item No. 4.00 above, but 80mm bore. |
| 10 | Description all as per ser item No. 4.00 above, but 100mm bore. |
| 11 | Laying only GI water mains after removal of scalling, cleaning and flushing etc including supply and fixing of new fittings for 15mm bore pipe, complete, all as specified and directed. |
| 12 | All as per item No. 11 above but 20 mm bore. |
| 13 | All as per item No. 11 above but 25 mm bore. |
| 14 | All as per item No. 11 above but 40mm bore. |
| 15 | All as per item No. 11 above but 50mm bore. |
| 16 | All as per item No. 11 above but 80mm bore. |
| 17 | All as per item No. 11 above but 100mm bore. |
| 18 | Supply and laying GI water tubing, medium grade, galvanised (ISI marked as IS-1239), with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor trench complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc), complete, all as specified and directed for 15 mm bore. |
| 19 | All as per item No. 18 above but 20mm bore. |
| 20 | All as per item No. 18 above but 25mm bore. |
| 21 | All as per item No. 18 above but 40mm bore. |
| 22 | All as per item No. 18 above but 50mm bore. |
| 23 | All as per item No.18 above but 80mm bore. |
| 24 | All as per item No. 18 above but 100mm bore. |
| 25 | Supply and fixing in repair Gun metal globe or gate valves, with iron wheel head screwed both ends for iron pipe of 15mm bore and fixed, complete, all as specified and directed. |
| 26 | Supply and fixing in replacemnt Gun metal globe or gate valves, with iron wheel head screwed both ends for iron pipe of 20mm bore and fixed, complete, all as specified and directed. |
| 27 | Supply and fixing in replacemnt Gun metal globe or gate valves, with iron wheel head screwed both ends for iron pipe of 25mm bore and fixed, complete, all as specified and directed. |
| 28 | Supply and fixing in replacemnt Gun metal globe or gate valves, with iron wheel head screwed both ends for iron pipe of 40mm bore and fixed, complete, all as specified and directed. |
| 29 | Supply and fixing in replacemnt Gun metal globe or gate valves, with iron wheel head screwed both ends for iron pipe of 50mm bore and fixed, complete, all as specified and directed. |
| 30 | Supply and fixing in replacement of cast iron sluice valve of 80mm dia with flanged ends class PN 1 .6 with iron wheel, stainless steel spindle and check nut confirming to IS :14846 incl all jointing materials such as nuts, bolts, washers and gaskets etc complete all as directed. |
| 31 | Description all as per ser item No. 30.00 above, but size100 mm dia. |
| 32 | Repair/maint of water leakage from DI pipe joint in ground and open carefully the joint portion of the of the pipe line duly excavated the trench and burning out the defective run lead joint in existing of CI pipe/fitting and provision of new lead joint in site using the retrieved lead as obtaining from burning out of joint and adding of fresh lead if required to make the joint 100% water leak proof including returning, filling and ramming the excavated materials after satisfactory, joint/leak chacking all as directed for following bore of CI pipe line :- (a) 100 mm bore pipe line. |
| 33 | (b) 80 mm bore pipe line. |
| 34 | M&L Lagging on pipes of internal dia 20 mm, used in external water supply or plumbing all round with, 40mm thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842, provided with chicken mesh wire netting 25 gauze 20mm mesh and finally covering with plaster of pairs including taking down old, complete, all as specified and directed. |
| 35 | All as per item No. 34 above but 25 mm bore tubing. |
| 36 | All as per item No. 34 above but 40mm bore tubing. |
| 37 | All as per item No. 34 above but 40mm thick bonded and for 50mm bore tubing. |
| 38 | All as per item No. 34 above but GI/DI pipe of 40mm thick bonded and for 80mm bore tubing. |
| 39 | All as per item No. 34 above but GI/DI pipe of 40mm thick bonded and for 100mm bore tubing. |
| 40 | Disconnectiong existing defective electric motor of any make upto 20 HP from electric mains isolating the necked connections, removing from foundation by unscrewing the nuts, bolts etc, discouple from pump, opening of motor for inspection in presence of Engr-in-Charge and carry out minor repairs at site or transporting to workshop and back, reassembling the motor after repair, refixing in position reconnecting same as prior to removing from foundation including replacement of nuts, bolts washers of suitable size, testing and commissioning complete all as specified and directed. Note :- (a) Replacement of defecting parts shall be measured and paid separately as S&F here after. (b) In case of major repairs not possible at site, the motor shall be shifted to Civil workshop, and cost of shifting to wksp and back to site included in the rates.The spares are as follows:- |
| 41 | (a) Gland Packing of any size |
| 42 | (b) Impeller for 20 HP Pump. |
| 43 | (c) Impeller for 15 HP Pump. |
| 44 | (d) Pump shaft with nut for 20 HP Pump. |
| 45 | (e) Pump shaft with nut for 15 HP Pump. |
| 46 | (f) Bearing for 20 HP Pump |
| 47 | (g) Bearing for 15 HP Pump |
| 48 | (h) Tyre coupling set for 10/15/20 HP Pumping Set |
| 49 | (j) Neck ring for pump set capacity of 10/15/20 HP |
| 50 | Carrying out rewinding and overhauling of motor assembly after cutting burnt winding wire, cleaning of core slots and re- winding by using super enameled copper winding wire of appropriate gauge and turn as per existing incl providing all insulation materials & varnishing heating, replacement of worn out bearing bushing etc incl lubrication, and assembling the complete motor assembly, testing complete for following capacity motor. NOTE :- (a) All new spares/components will be measured and paid separately under respective items. (b) Replacement of bolts/nuts/washers are deemed to be included in the items. The following : (a). Motor of capacity 20 HP. |
| 51 | (b) Motor of capacity 15 HP. |
| 52 | (c) Motor of capacity 10 HP. |
| 53 | Supply and fixing in replacement Automatic star delta starter for 5 HP submersible pump 3 Phase 415 volts, as per existing complete all as specified and directed. |
| 54 | Taking out old unsv chnage over switch of any capacity and supply & fixing connecting off load change over switch 4 pole 200 Amp 440 volts conforming to relevant IS including all connecting and jointing material complere, complete all as specified and directed. Make:- Havells/L&T/Stanadard |
| 55 | Supply and laying rubber matting electrical grade of size 2m x1m x 10mm ISI marked, laid in front of the LT panel all as specified and directed |
| 56 | Earthing complete with GI earth plate 60cmx60cmx6mm thick electrode and 32 x 6 mm GI strip as earthing lead. buried directly in ground ( earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level. connected to GI strip 32 x 6 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 and incl earth work, PCC pit and RCC cover, atering pipe 20 mm dia light grade, funnel, wire mesh, charcoal dust and salt etc and connected to earthing test point, complete, all as specified and directed. Note:- Item of earthing includes cost of 7.5m long GI earth lead 32x6mm and protection of 40mm bore GI light grade including testing |
| 57 | Supply and fixing in replacement of Ampere meter 0 to 200 Amps Digital type with selector switches, CTs etc. complete all as specified and directed. |
| 58 | Supply and fixing in replacement of volt meters 0 to 500 Volts Digital type 415 volts with selector switches etc., complete all as specified and directed. |
| 59 | Supply and fixing in replacement single phase preventor, complete all as specified and directed. |
| 60 | Supply and fix in replacement of CIDFS wing type NRV size 100 mm dia bore as per IS-5312 of PN-1.6 type including nuts, bolts and jointing materials complete all as specified and directed. |
| 61 | Supply and fix in replacement of CIDFS wing type NRV size 80 mm dia bore as per IS-5312 of PN-1.6 type including nuts, bolts and jointing materials complete all as specified and directed. |
| 62 | Supply and fix in replacement foot valve of size 80 mm dia bore flanged end drilled type including nuts, bolts and jointing materials complete all as specified as per IS -4038. |
| 63 | Supply and fix in replacement foot valveof size 100 mm dia bore flanged end drilled type including nuts, bolts and jointing materials complete all as specified as per IS -4038. |
| 64 | Supply and fixing in replacement of Automatic star delta starter suitable for 10 HP Centrifugal pump Sets 415 volt, 3 Phase, 50 Hz, including single phase Preventer complete. |
| 65 | Supply and fixing in replacement of Automatic star delta starter suitable for 20 HP Centrifugal pump Sets 415 volt, 3 Phase, 50 Hz, including single phase Preventer complete. |
| 66 | M & L for cleaning of underground water sump by pumping out water below suction level, removing all internal deposited sludge by non clogging submersible pump, cleaning the surface of the sump using wire brushes and other scraping tools to remove dirt and scales to make it free from all deposits, washing the sump with high pressure compressor nozzle thoroughly and removing dirty water from the pump to make it clean including repair to the internal surfaces by plastering with cement mortar 1:3,15mm thick and providing fillers at cracks using chemical (Doctor fixit) as required to prevent any seepage of water including disinfecting the sump surfaces, complete, Painting one coat of anti bacteria water proof paint all as specified and directed of 50000 gallons capacity. (Note:- the work of cleaning and disinfection will be carried out by expert in the field of the work. the work will be carried out in such a way that the water supply is not interupted; necessary bypass arrangement to be done). |
| 67 | Collecting the water samples in the sterilised container from the different locations at Haft Chinar pump houses in the sealed container in presence of concerned dept rep and transport to National / State Govt Authorised laboratory such as PHE/NTH or any Govt approved agenises and carrying out the Physical / Chemical / Biological analysis i.e PH, Chloride (CL), Total Hardness as Ca CO₃, Total dissolved solids and submitting the details report as per standard parameters in duplicate to this office all as specified and as directed complete, all as specified and directed. |
| 68 | M&L for construction of Brick Masonry valve chamber of size 900x900x600mm (Internal dimensions) with PCC 1:4:8 foundation 150mm thick, brick work built in CM 1:6, PCC 1:3:6 coping 50mm thick, plastering 15mm thick in CM 1:6 to all internal and exposed surfaces including excavation earthwork in hard/dense soil, MS sheet cover 4mm thick and MS equal angle iron 50mmx50mmx6mm frame as per existing size with locking arrangement embedded in PCC suitable for 25/40/50mm gate valve and painting to MS cover with two coats of synthetic enamel paint over one coat of red oxide primer etc complete all per Drg. No HQ/136/TD/96 V and ground requirement including dismantling old/damaged valve pits. |
| 69 | M&L for fixing of Air release valve matching with existing make complete with brass spindle, coller neack nuts all as per existing type of sluice valves for the following size including dismentling old worn-out spindle (Note : Brass spindle shall be fabricated from solid round bar having dia not less than the dia of the dia of the largest section of the spindle and not using anyriveting for expended coller of the spindle or by casting and machining to make the spindle a single piece for the following of sizes:- (a) 80 mm bore pipe line. |
| 70 | (b) 100 mm bore pipe line. |
| 71 | Repairs/rectification of GI Pipe leakage by replacing short piece length up to 0.50 mtr in wall/floors etc and excavation upto 1 cum as in trenches and including providing unions, reducers,nipples etc and making necessary connections to make it functional complete all as specified and as directed for the following sizes:-(a) 15 mm bore pipe |
| 72 | (b) 20 mm bore pipe |
| 73 | (c ) 25 mm bore pipe |
| 74 | (d) 40 mm bore pipe |
| 75 | (e) 50 mm bore pipe |
| 76 | Supply and fixing in repairs GI/ DI mechanical joints, non extendable type with rings, nuts , bolts & washers etc complete all as specified and as directed for the following sizes:-(a) 80 mm bore |
| 77 | (b) 100 mm bore pipe |
| 78 | Taking down in repair of high mast light, Hot dip galvanised Mast 15/20Mtr high and Luminaires carriage duly opening of nut & bolts at bottom with the help of Hydra/Crane for repair /replacement of old UNSV Winch and steel ropes (as per existing 6/8mm) complete with ratchet, limit switches etc as per standerd engineering practice to avoid falling of carrier during raising or lowering and re-installation, testing at site and commissioning after satisfactorily repair complete all as specified and directed. |
| 79 | Annual maintenance/servicing and replacement of unserviceable consumable items of Reverse Osmosis water purifier of capacity 20/25/50 Ltrs/hrs installed at various location, required rectifying any type of blockage,loose connection in electric and electronic components of plants, servicing of the plant to be carried as directeded by Engr-in- charge. Note-:(i ) All the spares/components required for the repair and servicing shall be measured and paid separately here-in- after as supplied only. complete all as specified and directed at site by Engr-in-charge. The relevant following spares are as bellow:- |
| 80 | (i) Supply only new sediment filters 20 inch long . |
| 81 | (ii) Supply only new Activated carbon filters 20 inch long . |
| 82 | (iii) Supply only new Carbon block granule 20 Inch . |
| 83 | (iv) Supply only new RO membrane set (open/Closed) |
| 84 | (v) Supply only new solenoide valve . |
| 85 | (vi) Supply only new AC/DC Adepoter 48 Volts ultera violet lamp . |
| 86 | (vii) Supply only low pressure switch . |
| 87 | (viii) Supply only new TDS valve. |
| 88 | (ix) Supply only new Booster pump 150 SPD . |
| 89 | M&L for replacement old unserviceable PVC pipe of suitable size with all fittings for 15/25/50 Ltrs RO plant complete all as specified and directed by Engr-in-charge |
| 90 | Annual maintenance/servicing and replacement of unserviceable consumable items of Reverse Osmosis water purifier of capacity 2000LPH installed Pump House Haft Chinar, required rectifying any type of blockage,loose connection in electric and electronic components of plants, servicing of the plant to be carried as directeded by Engr-in- charge. Note-: (i) All the spares/components required for the repair and servicing shall be measured and paid separately here-in- after as supplied only and complete all as specified and directed at site by Engr-in-charge. The relevant following spares are as bellow:- |
| 91 | (i) Supply only Iron Removal Chemical |
| 92 | (ii) Supply only treatment media as required for existing media container Salt Tablets (for water softner), Activated carbon, Sand, Pebbles, Gravel media for RO plant of 2000LPH |
| 93 | (iii) Supply only sediment flter 20'' big blue cylindrical Housing |
| 94 | (iv) Supply only antiscalant chemical |
| 95 | (v) Supply only Ph balance 15 ltr |
| 96 | (vi) Supply only UPVC tubing upto 40mm high strength with necessary accessories like Unior/Gate valve/ elbo/socket/tee, fitting/pipes working temperature 5C to 60C Note: All UPVC Fittings/accessories should be brass grooved. |
| 97 | (vii) Supply only UPVC flow meter with float switch |
| 98 | (viii) Supply only pressure guage with Pressure Switch |
| 99 | M&L for rewinding of unserviceable booster pumps capacity 01 to 02 HP as directed by Engineer-in -charge |
| 100 | Supply only granular Chlorine (60% of chlorine content) disinfectant superior quality of approved make for mixing with drinking water for water treatment, complete all as specified and directed. |
| 101 | Material & Labour for overhauling of monoblock/centrifugal pump sets 1 HP to 5 HP capacity and reassembling the same after replacement of the following unserviceable/defective parts including testing of pump sets, complete all as specified and as directed with the connected items of shaft, Impeller, coupling, gunmetal bush, bearings nuts, bolts and gland etc. |
| 102 | Taking out old unserviceable/burnt winding from the monoblock/centrifugal motors 1 HP to 5 HP and rewindinig the same with insulated winding wire as per existing gauge as approved by Engr-in Charge and testing after repair, complete all as specified and as directed. |
| 103 | M&L, Construction of Brick Masonry valve chamber of size 600x600x600mm (Internal dimensions) with PCC 1:4:8 foundation 150mm thick, brick work built in CM 1:6, PCC 1:3:6 coping 50mm thick, plastering 15mm thick in CM 1:6 to all internal and exposed surfaces including excavation earthwork in hard/dense soil, MS sheet cover 4mm thick and MS equal angle iron 50mmx50mmx6mm frame as per existing size with locking arrangement embedded in PCC suitable for 25/40/50mm gate valve and painting to MS cover with two coats of synthetic enamel paint over one coat of red oxide primer etc complete all as specified. |
| 104 | M&L for fabrication and fixing of brass/stainless steel spindle for sluice valve matching with existing make complete with coller neack nuts all as per existing type of sluice valves for the following size including dismentling old worn-out spindle (Note : Brass spindle shall be fabricated from solid round bar having dia not less than the dia of the dia of the largest section of the spindle and not using anyriveting for expended coller of the spindle or by casting and machining to make the spindle a single piece): (a) 100 mm bore pipe line. |
| 105 | (b) 80 mm bore pipe line. |
| 106 | M & L for straight plain brass ferrules (or connecting screws) screwed both ends and fixied bore diameter of pipe in 20 mm on cast iron / ductile iron water mains, in position, for branch connections complete all as specified and directed. |
| 107 | (a) All as per serial No. 106 above but bore of pipe in 25 mm |
| 108 | Supply, connecting, testing and commissioning submersible cable with copper conductor, stranded of size 6 sqmm 3 core, complete, all as specified and as directed. |
| 109 | Supply & laying underground cable in trenches/existing cable duct/ cable tray, PVC heavy duty electric cable with copper conductor sizes of 25 sqmm single core confirming to IS : 7098 (Pt-I) 1988 and copper lugs for connecting cable at end of motor & starter complete all as indicated and directed by Engr-in-Charge. |
| 110 | Supply & laying of GI perforated cable tray 1 mm thick and size of 400 x 75 x 10 mm for PVC heavy duty electric cable with copper conductor from motor to starter complete all as indicated and directed by Engr-in-Charge. |
| 111 | Disconnecting the engine from base & alternater, labour for dismantling of the top section, top overhauling including replacement of worn out parts, reassembling, connecting with alternator including testing for satisfactory running to entire satisfaction of Engr-in-charge, complete, all as specified and directed for 62.5 KVA capacity of any make.Note :- Spare parts will be measured seperately under respective item of schedule of work. |
| 112 | All as per item No.111.00 above but for 10KVA to 32.5KVA capacity. Note:- (Item 01 to 02) (i) Worn out parts required to be replaced will be measured and paid for separately. (ii) Dismantling as per site requirement for repair and any minor parts required for making the DG Set fully operational not mentioned in subsequent items is deemed to be included in rates quoted.SM/MES No : 02H/6054/DG/03, 02H/6030/-DG/03, 02H/6026-DG/01, 02H/6052/DG/03, 02H/6001-DG/03, 02H/6050/DG/03, 02H/6048/DG/03, 02H/6028-DG/03, 02H/6029-DG/03 , 02H/6045-DG/06 (Haft Chinar) |
| 113 | Supply only in replacement cylinder liner with liner ring for DG set of 62.5 KVA |
| 114 | All as per item No. 113.00 above but for 10 KVA to 32.5 KVA capacity |
| 115 | Supply only in replacement piston ring set for DG set of 62.5 KVA capacity |
| 116 | All as per item No. 5 above but for 10 KVA to 32.5 KVA capacity |
| 117 | Supply only in replacement gasket set with ‘O’ ring set for 62.5 KVA capacity of DG Set |
| 118 | All as per item No. 117.00 above but for 10 KVA to 32.5 KVA capacity |
| 119 | Supply only in replacement inlet/exhaust valve pair for 62.5 KVA capacity of DG Set |
| 120 | All as per item No. 119.00 above but for 10 KVA to 32.5 KVA capacity |
| 121 | Supply only in replacement main bearing set for DG Set of 62.5 KVA capacity |
| 122 | All as per item No. 121.00 above but for 10 KVA to 32.5 KVA capacity |
| 123 | Supply only in replacement main oil seal (Rear & Front) for DG Set of 62.5 KVA capacity |
| 124 | All as per item No. 123.00 above but for 10 KVA to 32.5 KVA capacity |
| 125 | Supply and fixing in replacement flexible coupling for DG set of 62.5 KVA capacity |
| 126 | All as per item No. 125.00 above but for 10 KVA to 32.5 KVA capacity |
| 127 | Supply and fixing in replacement lub oil filter for DG Set of 62.5 KVA capacity |
| 128 | All as per item No. 127.00 above but for 10 KVA to 32.5 KVA capacity |
| 129 | Supply and fixing in replacement fuel filter for DG Set of 62.5 KVA capacity |
| 130 | All as per item No. 129.00 above but 32.5 KVA/ 25 KVA/20 KVA/10 KVA capacity |
| 131 | Supply and fixing in replacement fan belt for DG Set of 62.5 KVA capacity |
| 132 | All as per item No. 131.00 above but for 10 KVA to 32.5 KVA capacity. |
| 133 | Supply only crank shaft as required 62.5 KVA DG set of any make and model including testing complete all as specified and directed. |
| 134 | All as per item No. 133.00 above but 10 KVA to 32.5 KVA capacity |
| 135 | Supply only cam shaft as required 62.5 KVA DG set of any make and model including testing complete all as specified and directed. |
| 136 | Supply only connector rod as required 62.5 KVA DG set of any make and model complete all as specified and directed. |
| 137 | All as per item No.136.00 above but for 10 KVA to 32.5 KVA capacity. |
| 138 | Supply only in replacement head gasket with ‘O’ ring for 62.5 KVA capacity of DG Set |
| 139 | All as per item No. 138.00 above but for 10 KVA to 32.5 KVA capacity |
| 140 | Supply only in replacement began for 62.5 KVA capacity of DG Set |
| 141 | All as per item No. 140.00 above but for 10 KVA to 32.5 KVA capacity |
| 142 | Supply only in replacement main began for 62.5 KVA capacity of DG Set |
| 143 | All as per item No. 142.00 above but for 10 KVA to 32.5 KVA capacity |
| 144 | Extracting burnt /unserviceable valve seats 62.5 KVA DG set and re-fixings after cutting grinding and polishing as per new valves including head facing and transporting to and from work shop complete all as specified and directed. |
| 145 | All as per srl item No 144.00 above but capacity 10 KVA to 32.5 KVA DG Set. |
| 146 | Dismantling and taking down unserviceable fuel injector pump transporting to work shop for the following repairs DG sets transporting back to site re-fixing and testing after completion, complete, all as specified and directed. |
| 147 | Calibration and complete repair of fuel injector pump of DG set 62.5 KVA (Pressure type) on work bench pressure supply of fuel as per standard procedure and testing complete. |
| 148 | All as per srl item No 147.00 above, but capacity 10KVA to 32.5 KVA DG Set. |
| 149 | Dismantling and taking down unserviceable fuel injector nozzle transporting to work shop for repairs transporting back to site re-fixing and testing after completion, complete, all as specified and directed. |
| 150 | Overhauling and testing of injector nozzle on test bench for fine mist spray including replacement unserviceable parts for DG set of capacity 62.5 KVA complete all as specified and directed. |
| 151 | All as per item no. 150.00 above, but for 10 KVA to 32.5 KVA DG set. |
| 152 | Taking down turbo charger carefully dismantling and replacement of complete turbo charge and re-fixing to its original position complete all as specified and directed for upto 62.5 KVA DG set. |
| 153 | Taking down radiator complete from its mounting, dislodging top and bottom tank, cleaning complete tube by descaling solution and finally re-installing in original position, complete, all as specified and directed for 10 KVA to 62.5 KVA. |
| 154 | Preparation and Painting of complete DG set including frame by two coats of enamelled paint as per colour code by spray painting and marking etc complete, all as specified and directed for 62.5 KVA. |
| 155 | Preparation and Painting of complete DG set including frame by two coats of enamelled paint as per colour code by spray painting and marking etc complete, all as specified and directed for 10 KVA to 32.5 KVA. |
| 156 | Dismantling alternator from the engine base for repairing including transporting to workshop, reinstalling, reconnecting with engine including testing on load for 10 KVA to 32.5 KVA DG set, complete, all as specified and directed. |
| 157 | All as per item No. 156.00 above, before but for 62.5 KVA DG set. |
| 158 | Rewinding of armature with super enamelled copper of required size wire including varnishing, sleeves, cotton tape and heating etc. for DG Set of capacity 62.5 KVA , complete, all as specified and directed. |
| 159 | All as per item No. 158.00 above, but for 10 KVA to 32.5 KVA DG set. |
| 160 | Dismantling, rewinding of field coils of alternator with super enamelled wire including varnishing and heating including reassembling and testing for capacity of DG Set 62.5 KVA, complete, all as specified and directed. |
| 161 | All as per item No. 160.00 above, but for 10 KVA to 32.5 KVA DG set |
| 162 | Dismantling and taking down unserviceable self starter transporting to work shop for the repair and transporting back to site after complete repairs re-installation at site and testing after completion, complete, all as specified and directed. |
| 163 | Repair to self starter including rewinding the coil winding, bearing pinion bush solenoid switch carbon brush and holder including transporting back to site, re-installing and testing complete all as specified and directed of 62.5 KVA capacity DG Set. |
| 164 | All as per item No. 163.00 above,, but for 10 KVA to 32.5 KVA DG set. |
| 165 | Dismantling and taking out old dynamo and transporting to workshop for repair and transporting back to site after complete repair, reinstalling at site and testing complete all as specified and directed. Please Enable Macros to View BoQ information |
| 166 | Dismantling and taking out old dynamo and transporting to workshop for repair and transporting back to site after complete repair, reinstalling at site and testing complete all as specified and directed. Please Enable Macros to View BoQ information |