| 1 | Dismantalling of Switchgear System of 33 KV C&R Panel |
| 2 | Dismantalling of Switchgear System of 33 KV VCB Panel |
| 3 | Dismantalling of Switchgear System of 11KV VCB Panel |
| 4 | Fixing,installing,testing and commissioning of Switchgear System complete job( including relay testing) of 33 KV C&R Panel |
| 5 | Fixing,installing,testing and commissioning of Switchgear System complete job( including relay testing) of 33KV VCB breaker |
| 6 | Fixing,installing,testing and commissioning of Switchgear System complete job( including relay testing) of 11KV VCB Panel |
| 7 | Fixing,installation, testing & commissioning,testing of fresh Numerical/Digital/electromagnetic Relays by way of Replacement of Damaged/Burnt already installed in panel.(including fabrication of slot in the pannel if required) |
| 8 | Fixing,installing,commissioning,testing of fresh Master tripping relay.(including fabrication of slot in the pannel if required) |
| 9 | Rectification ,setting right the electrical section (Panel wiring) of 11KV VCB Panel including replacement of damaged parts like Rotor selector switch,TNC switch etc excluding Relay & Motor |
| 10 | Rectification,Re-Alignment,setting right the mechnical section of 11KV Breakers which includes replacement of damaged parts excluding Vacuum interrupter |
| 11 | Rectification ,setting right the electrical section (Panel wiring) of 33KV C&R Panel including replacement of damaged parts like Rotor selector switch,TNC switch etc excluding Relay |
| 12 | Rectification,re-alignment,setting right the mechnical/ electrical section of 33KV Breakers which includes replacement of damaged parts excluding Vacuum Interrupter.& motor |
| 13 | Rewinding /repairing of Spring Charging motor of 11KV/33KV VCB breaker |
| 14 | Repairing of damaged parts including testing & commissioning of Electromagnetic relays/Trip Ckt supervision Relay/Buchloz Relay/Auxillary relays/Master Relay |
| 15 | Repairing of damaged parts including testing & commissioning of Numerical relays |
| 16 | Replacement and commissioning of damaged clamps of sizes |
| 17 | Repairing /replacement of damaged parts including testing & commissioning of 36V Battery Charger. |
| 18 | Installation,Testing & Commissioning of 33KV Post Insulators confirming to IEC 61109/92-93 with latest amendments including dismentling of damaged one, if any |
| 19 | Fixing, installation, testing and commissioning of 33KV Isolators(W E/B or W.O E/B) 1250 Amps including dismentling of damaged one, if any |
| 20 | Fixing, installation, testing and commissioning of 33KV Isolator Grovees including alignment of isolator and dismentling of damaged parts , if any |
| 21 | Erection of 10' Long Equipment structure Pipe in the 33KV ODY by using Grouting Bolts |
| 22 | Laying,Testing,commissioning of 33KV (E) grade ,400 Sq mm,armoured ,3-core,Xlpe Power Cable including dismentling of damaged one, if any |
| 23 | Laying,Testing,commissioning of 33KV (E) grade ,400 Sq mm,armoured ,1-core,Xlpe Power Cable including dismentling of damaged one, if any |
| 24 | Laying,Testing,commissioning of 11KV (E) grade armoured ,630 Sq MM,3-core,Xlpe Power Cable including dismentling of damaged one, if any |
| 25 | Laying,Testing,commissioning of 11KV (E) grade armoured ,630 Sq MM,1-core,Xlpe Power Cable including dismentling of damaged one, if any |
| 26 | Laying,Testing,commissioning of 11KV (E) grade armoured ,400 Sq MM,3-core,Xlpe Power Cable including dismentling of damaged one, if any |
| 27 | Laying,Testing,commissioning of 11KV (E) grade armoured ,400 Sq MM,1-core,Xlpe Power Cable including dismentling of damaged one, if any |
| 28 | Laying,Testing,commissioning of 11KV (E) grade armoured ,300 Sq mm,3-core,Xlpe Power Cable including dismentling of damaged one, if any |
| 29 | Laying,Testing,commissioning of 11KV (E) grade armoured ,300 Sq mm,1-core,Xlpe Power Cable including dismentling of damaged one, if any |
| 30 | Laying,Testing,commissioning of 11KV (E) grade armoured ,240 Sq mm,3-core,Xlpe Power Cable including dismentling of damaged one, if any |
| 31 | Laying,Testing,commissioning of 11KV (E) grade armoured ,240 Sq mm,1-core,Xlpe Power Cable including dismentling of damaged one, if any |
| 32 | Laying,Testing,commissioning of 11KV (E) grade armoured ,185/120 Sqmm,3-core,Xlpe Power Cable including dismentling of damaged one, if any |
| 33 | Laying,Testing,commissioning of 11KV (E) grade armoured ,185/120 Sqmm,1-core,Xlpe Power Cable including dismentling of damaged one, if any |
| 34 | Laying,Testing,commissioning of 2.5 sqmm 2/4/6/8/12/16 Core Control cable armored , copper conductor sheathed PVC insulated multi colour voltage grade 1.1 KV |
| 35 | Laying,Testing,commissioning of L T Cable 3 1/2 core armored , copper / Al conductor sheathed PVC insulated . |
| 36 | Deweeding of 33 KV out door Yard of receiving station including cleaning of cable trenchs etc. |
| 37 | Making damaged 11KV XLPE cables of sizes and lengths ready for cable end termination by way of dragging of cable from cable trunch/cutting etc |
| 38 | Dressing of 11KV XLPE Power cables of Sizes in the cable trunch |
| 39 | Installation,Testing & Commissioning of 11KV 3 Core (400/300/240/185/120 Sq mm-I/D or O/D) Cable end termination Kit heat shrinkable including required size of lugs/thimbles including dismantelling of damaged one |
| 40 | Installation,Testing & Commissioning of 33 KV 3 Core(630/400 Sqmm)-I/D or O/D Cable end termination Kit heat shrinkable outdoor including lugs/thimbles |
| 41 | Installation testing and commissioning of 11KV Vacuum Interrupter (BHEL, Crompton Greaves, Alsthom, ABB etc Make including dismentling of damaged one, if any |
| 42 | Installation,Testing & Commissioning of 33 KV Outdoor, Oil Cooled, Live Tank, single Phase , 3/2 Core CT set of different ratios including dismentling of damaged one, if any |
| 43 | Installation,Testing & Commissioning of 33 KV Outdoor, Oil Cooled, Copper Wound , single Phase , PT with rated primary voltage 33000/√3 & rated Secondary voltage 110/√3 per set of 3 pieces) including dismentling of damaged one, if any |
| 44 | Installation,Testing & Commissioning of 33 KV Lightening Arrestor Set,Outdoor, Metal Oxide Gapless (per set of 3 pieces) including dismentling of damaged one, if any |
| 45 | Installation,Testing & Commissioning of 11 KV Lightening Arrestor set,Outdoor, Metal Oxide Gapless (per set of 3 pieces) including dismentling of damaged one, if any |
| 46 | Installation,Testing & Commissioning of 11 KV Indoor ,Dry, Copper Wound , Three Phase , PT Set in MS enclosure with rated primary voltage 11000/√3 & rated Secondary voltage 110/√3 (per set of 3 pieces) including dismentling of damaged one, if any |
| 47 | Installation,Testing & Commissioning of 11 KV Indoor type,Dry,Resin cast, Single Phase ,3/ 2 Core CT Set as per ISI specification preferably of BHEL/Crompton Greaves/Alsthom/Allind /ER Make) with required ratio (per set of 3 pieces) including dismentling of damaged one, if any |
| 48 | Loading of Auxilary transformer including dragging to loading site 25/63/100KVA |
| 49 | Unloading of Auxilary transformer including dragging to requisite site 25/63/100KVA |
| 50 | Installation , testing and commissioning of Auxilary transformer 25/63/100KVA |
| 51 | Fixing and commissiong of Panel Bush/Breaker Bush/Auxillary switch/Interruptor Housing for 11KV VCB panels |
| 52 | Oil filling / topping of Power Transformer/33 KV CT/33KV PT etc |
| 53 | Improvement of Earthing / Extension of Earthing Mate including earthwork,Straightning,Welding etc using MS Flat |
| 54 | I/T/C of Almunium Tubular Bus Bar |
| 55 | Loading of 10 MVA,33/11KV Power Transformer (from Transformer Bed to Plate Form) along with all allied accessories including its dismantling & dragging as per the requirements at site |
| 56 | Loading of 6.3 MVA,33/11KV Power Transformer (from Transformer Bed to Plate Form) along with all allied accessories including its dismantling & dragging as per the requirements at site |
| 57 | Loading of 5/4/3.15 MVA,33/11KV Power Transformer (from Transformer Bed to Plate Form) along with all allied accessories including its dismantling & dragging as per the requirements at site |
| 58 | Unloading of 10 MVA,33/11KV Power Transformer (from Plate Form to Transformer Bed ) along with all allied accessories including its dragging , rotation & stacking as per the requirements at site |
| 59 | Unloading of 6.3 MVA,33/11KV Power Transformer (from Plate Form to Transformer Bed ) along with all allied accessories including its dragging , rotation & stacking as per the requirements at site |
| 60 | Unloading of 5/4/3.15 MVA,33/11KV Power Transformer (from Plate Form to Transformer Bed ) along with all allied accessories including its dragging, rotation & stacking as per the requirements at site |
| 61 | Transportation of 10 MVA,33/11KV Power Transformer along with all allied accessories upto 50 Kms |
| 62 | Transportation of 6.3 MVA,33/11KV Power Transformer along with all allied accessories upto 50 Kms |
| 63 | Transportation of 5/4/3.15, 33/11KV Power Transformer along with all allied accessories upto 50 Kms |
| 64 | Additional transportation of 10 MVA,33/11KV Power Transformer along with all allied accessories per Km beyond 50 Kms |
| 65 | Additional transportation of 6.3 MVA,33/11KV Power Transformer along with all allied accessories per Km beyond 50 Kms |
| 66 | Additional transportation of 5/4/3.15 MVA,33/11KV Power Transformer along with all allied accessories per Km beyond 50 Kms |
| 67 | Installation,Testing and commissioning of 10 MVA,33/11KV Power Transformer (Complete Job) |
| 68 | Installation,Testing and commissioning of 6.3 MVA,33/11KV Power Transformer (Complete Job) |
| 69 | Installation,Testing and commissioning of 5/4/3.15 MVA 33/11KV Power Transformer (Complete Job) |
| 70 | Setting right of Power Transformer Protection ( Bucholz/Oil Temp./Winding Temp Ckt.) |
| 71 | De-commissioning of damaged 10/6.3/5/4/3.15 MVA Power Transformer |
| 72 | Testing & Commissioning of Parallel operation of Power Transformers |
| 73 | Loading of 11 KV Panel/33 KV C&R panel including dragging to loading site |
| 74 | Unoading of 11KV Panel/33 KV C&R panel including dragging to requisite site |
| 75 | Fixing , installation, testing and commissioning of 11 KV link set including dismentling of damaged one, if any |
| 76 | Fixing, installation, testing & commissioning of 11KV G.O Set 800 Amps including dismentling of damaged one, if any |
| 77 | Fixing ,installation testing & Commissioning of 11KV Isolators including dismentling of damaged one, if any |
| 78 | Fixing ,installation testing & Commissioning of (33KV DO / Fuse set) including dismentling of damaged one, if any |
| 79 | Installation/Testing/Commissioning of 36 V Battery Charger |
| 80 | Installation/Testing/Commissioning of 36 V Battery Bank including dismanteling of existing one if any |
| 81 | Installation/Testing/Commissioning of AC Distribution Board including dismanteling of existing one if any |
| 82 | Installation/Testing/Commissioning of DC Distribution Board including dismanteling of existing one if any |
| 83 | Repairing of A/C and D/C Distribution Board by way of replacing of damaged MCB(5A/10A) etc |
| 84 | Repairing of 33 KV ODY LED Lights |
| 85 | I/T/C of 36V Tripping Coil for 11KV VCB Breaker like Easun Reyroll, Allind, Alsthom, Crompton Greeves, Electric field, Sudhir or the like including dismantelling of damaged one |
| 86 | I/T/C of 36V Closing Coil for 11KV VCB Breaker like Easun Reyroll, Allind, Alsthom, Crompton Greeves, Electric field Sudhir or the like including dismantelling of damaged one |
| 87 | Erection of 13 Mt Steel Tubular Pole with planting depth of 1/6 th of the height of the pole |
| 88 | Erection of 11 Mt Steel Tubular Pole with planting depth of 1/6 th of the height of the pole |
| 89 | Erection of 9 Mt Steel Tubular Pole with planting depth of 1/6 th of the height of the pole |
| 90 | Dismantling of 13 Mt S.T pole/Wooden/PCC pole and returning to divisional Stores Lazbal Anantnag |
| 91 | Dismantling of 11 Mt S.T pole/Wooden/PCC pole and returning to divisional Stores Lazbal Anantnag |
| 92 | Dismantling of 9 Mt S.T pole/Wooden/PCC pole and returning to divisional Stores Lazbal Anantnag |
| 93 | Painting of 13 Mt S.T Poles including fixtures with one coat of red-oxide and two coats of silver(aluminium) paint |
| 94 | Painting of 11 Mt S.T Poles including fixtures with one coat of red-oxide and two coats of silver(aluminium) paint |
| 95 | Painting of 9 Mt S.T Poles including fixtures with one coat of red-oxide and two coats of silver(aluminium) paint |
| 96 | Cement Bottoming (U/G,A/G) in 1:2:4 mix including excavation and form work (0 .78 Cum) as per REC of 13 Mt long ST Poles |
| 97 | Cement Bottoming (U/G,A/G) in 1:2:4 mix including excavation and form work (0 .66 Cum) as per REC of 11 Mt long ST Poles |
| 98 | Cement Bottoming (U/G,A/G) in 1:2:4 mix including excavation and form work (0 .48 Cum) as per REC of 9 Mt long ST Poles |
| 99 | Fixing & Commissioning of Almunium Thimbles of sizes |
| 100 | Fixing & Commissioning of Galvanised spiral Earthing of SWG No. 8, G.I wire of 115 turns confirming to REC-J1 construction standard |
| 101 | Fixing & Commissioning of 33KV Galvanised Guy Set including Guy wire,Guy Rods,Turn Buckle with plate ,Guy Insulators-Complete Job |
| 102 | Laying ,stringing,tensioning , binding of 0.05 ACSR Conductor |
| 103 | Laying ,stringing,tensioning , binding of 0.1 ACSR Conductor |
| 104 | Laying ,stringing,tensioning , binding of 0.15ACSR Conductor |
| 105 | Laying ,stringing,tensioning , binding of 0.2 ACSR Conductor |
| 106 | Fixing & Commissioning of 100/150/200 Sqmm ACSR P.G Clamps |
| 107 | Unloading of 13 Mt long Steel Tubular Pole/wooden/PCC pole including carriage upto dumping site |
| 108 | Unloading of 11 Mt long Steel Tubular Pole/wooden/PCC pole including carriage upto dumping site |
| 109 | Unloading of 9 Mt long Steel Tubular Pole/wooden/PCC pole including carriage upto dumping site |
| 110 | Loading of 13 Mt long Steel Tubular Pole/wooden/PCC pole including carriage upto dumping site |
| 111 | Loading of 11 Mt long Steel Tubular Pole/wooden/PCC pole including carriage upto dumping site |
| 112 | Loading of 9 Mt long Steel Tubular Pole/wooden/PCC pole including carriage upto dumping site |
| 113 | Unloading of Steel of Sorts including carriage to requisite site |
| 114 | Loading of Steel of Sorts including carriage to loading site |
| 115 | Unloading of Conductor 50/100/150/200 Sqmm including carriage to requisite site |
| 116 | Loading of Conductor 50/100/150/200 Sqmm including carriage to loading site |
| 117 | Fixing , installation, testing & Commissioning of Disc (70KN) Disc Insulator including dismentalling of damaged one, if any for 33KV Lines (Polymer/Porecelain) |
| 118 | Fixing , installation, testing & Commissioning of Disc (45 KN) Disc Insulator including dismentalling of damaged one, if any for 11KV Lines (Polymer/Porecelain) |
| 119 | Fixing , installation, testing & Commissioning of 33KV Pin Insulators (10 KN) including dismentalling of damaged one, if any COMPLETE |
| 120 | Fixing , installation, testing & Commissioning of Tension fittings suitable for 50/100/150/200 Sqmm ACSR including dismentalling of damaged one, if any |
| 121 | Fabrication of X-arms of different sizes of channel/Anglel/ Flat Iron and chequred plate. |
| 122 | Fixing of X-arms of different sizes of channel/Anglel/ Flat Iron with different sizes and sorts of nuts,bolts and washers |
| 123 | Restoration of Conductor snap 100/150/200 Sqmm |
| 124 | Restringing of loose conductor |
| 125 | Restoration of Burnt Jumper |
| 126 | Re-errection of tilted/fallen down poles |
| 127 | Branch Cutting of 33/11KV Line |
| 128 | Fixing ,installation testing & Commissioning of 33 KV link set conforming to IS 9921/IEC-129 standards |
| 129 | Unloading of various hardware/porcelin/ polymer materials in divisional stores at Lazbal Aanantnag, verification, carriage upto stocking site and stocking at proper place like, 33KV isolators, 11KV link sets,33KV/11KV CTs & PTs, cable kits, 33/11 KV insulators along with GI pins, 33/11KV LAs etc |
| 130 | Loading of various hardware/ porcelin/polymer materials in divisional stores at Lazbal Aanantnag, verification, carriage from stocking site to loading site including loading into the vehicle, like, 33KV isolators, 11KV link sets,33KV/11KV CTs & PTs, cable kits, 33/11 KV insulators along with GI pins, 33/11KV LAs etc. |
| 131 | UnLoading of various materials in divisional stores at Lazbal Aanantnag, verification, carriage upto stocking site and stocking at proper place like 33KV/11KV XLPE Cables of sizes , control cables of sizes etc. |
| 132 | Loading of various materials in divisional stores at Lazbal Aanantnag, verification, carriage from stocking site to loading site including loading into the vehicle, like, 33KV/11KV XLPE Cables of sizes , control cables of sizes etc. |
| 133 | Loading/Unloading of OPC Cement |
| 134 | Fixing of Danger Plate |
| 135 | Fixing of Anti climbing devices |
| 136 | Installation / Fixing of Guard netting of 33KV/11KV Lines as per REC |
| 137 | Providing of Tata Mobile (Load Carrier) on AS & WHEN REQUIRED BASIS for lifting/Carrying of Key Materials from Divisional Stores Laizbal Anantnag to Site and others . (Rate to be quoted on Per KM basis for each trip including fuel and taxes/toll ) |
| 138 | Providing of Truck on AS & WHEN REQUIRED BASIS for lifting/Carrying of ST Poles of sizes and other heavy material from Divisional Stores Laizbal Anantnag to Site and others. (Rate to be quoted on Per KM basis for each trip including fuel and taxes/toll ) Please Enable Macros to View BoQ information |