| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Executive Engineer Electric Division-III , JPDCL Jammu Name of Work: Restoration of power by way of deteriorated infrastructure of HT/LT flash Floods for Permanent restoration Creation under SASCI scheme. The period of execution shall be till the validity of this scheme and the same rates can also be used for other works under the jurisdiction of Electric Division-III, JPDCL, Jammu (J&K) for FY 2026-27.” Specific locations will be provided at the time of letter of award. Contract No: e-NIT No. 13 of 2026-27 dt. 30.04.2025. Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # |
| 2 | Item Description |
| 3 | Laying of 11 KV Line on PCC Pole 9.0 Mtr long using ACSR Weasel (Supplying including Transportation , Erection, Testing & Commissioning Comp. Job) |
| 4 | PCC Pole 9.0 Mtr long (WL 300 Kg) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. |
| 5 | GI Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminium paint coated including all necessary Nut & Bolts & Washers etc. |
| 6 | ACSR Weasel Conductor on Cross arms through insulators including proper binding & twisting with soft Aluminium Wire. |
| 7 | 11kV Polymeric composite Pin Insulator 12kV, 5kN,Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm |
| 8 | 11kV Polymeric composite Disc Insulator 12kV,minfailing load 45kN, Lighting Impulse 75kV Positiveand 80kV Negative, creepage distance 320mm |
| 9 | Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete |
| 10 | Danger Plates with Clamps |
| 11 | Anti Climbing device with Clamps |
| 12 | Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm, 2.5 Mtr Long through GI Strip |
| 13 | Stone Pad 300 mmx300mmx75mm |
| 14 | Aluminium Jointing sleeves |
| 15 | Laying of 11 KV Line on Steel Tubular Pole 9.0 Mtr long using ACSR Weasel/Rabbit. (Supplying including Transportation , Erection, Testing & Commissioning Comp. Job) |
| 16 | Steel Tubular Pole 9.0 Mtr long (ST-410 SP-33) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. |
| 17 | GI Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminium paint coated including all necessary Nut & Bolts & Washers etc. |
| 18 | ACSR Weasel Conductor on Cross arms through insulators including proper binding & twisting with soft Aluminium Wire. |
| 19 | 11kV Polymeric composite Pin Insulator 12kV, 5kN,Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm |
| 20 | 11kV Polymeric composite Disc Insulator 12kV,minfailing load 45kN, Lighting Impulse 75kV Positiveand 80kV Negative, creepage distance 320mm |
| 21 | Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete |
| 22 | Danger Plates with Clamps |
| 23 | Anti Climbing device with Clamps |
| 24 | Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm, 2.5 Mtr Long through GI Strip |
| 25 | Cement Bottoming |
| 26 | Aluminium Jointing sleeves |
| 27 | Laying of LT Line on PCC Poles 8.0 Mtr long using ACSR Weasel (Supplying including Transportation , Erection, Testing & Commissioning Comp. Job) |
| 28 | PCC Pole 8.0 Mtr long (WL-200 KG) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. |
| 29 | GI U-Clamp (duly painted with twio coats of Red Oxide and Al. paint) with Shackle Insulator (Polymer/Porcelain) along with Nut & Bolt of sorts |
| 30 | ACSR Weasel Conductor through insulators including proper binding & twisting with soft Aluminium Wire. |
| 31 | Danger Plates with Clamps |
| 32 | Anti Climbing device with Clamps |
| 33 | LT Line Spacers (3-Phase, 4-Wire) |
| 34 | Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm, 2.5 Mtr Long through GI Strip |
| 35 | Stone Pad 300 mmx300mmx75mm |
| 36 | Aluminium sleeves |
| 37 | Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete |
| 38 | Laying of LT Line on ST Poles 8.0 Mtr long using ACSR Weasel (Supplying including Transportation , Erection, Testing & Commissioning Comp. Job) |
| 39 | ST Pole 8.0 Mtr long (ST 410 SP15) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. |
| 40 | GI U-Clamp (duly painted with twio coats of Red Oxide and Al. paint) with Shackle Insulator (Polymer/Porcelain) along with Nut & Bolt of sorts |
| 41 | ACSR Weasel Conductor through insulators including proper binding & twisting with soft Aluminium Wire. |
| 42 | Danger Plates with Clamps |
| 43 | Anti Climbing device with Clamps |
| 44 | LT Line Spacers (3-Phase, 4-Wire) |
| 45 | Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm, 2.5 Mtr Long through GI Strip |
| 46 | Cement Bottoming |
| 47 | Aluminium sleeves |
| 48 | Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 No Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information Compatibility Report for BOQe-NIT68.xls Run on 05-03-2024 17:31 If the workbook is saved in an earlier file format or opened in an earlier version of Microsoft Excel, the listed features will not be available. Significant loss of functionality # of occurrences Version Any effects on this object will be removed. Any text that overflows the boundaries of this graphic will appear truncated. 3.0 Excel 97-2003 Some cells in this workbook contain data validation rules, which refer to values on other worksheets. These rules won't be saved. 4.0 Excel 97-2003 Minor loss of fidelity Some cells or styles in this workbook contain formatting that is not supported by the selected file format. These formats will be converted to the closest format available. 4.0 Excel 97-2003 |