| 1 | Supply,Installation, testing and Commsisoning of water cooler having 40 LPH cooling capacity and 80 Ltr storage capacity, 2 No tap, auto shut off stainless steel body of reputed make i.e Blue Star, voltas, Usha etc. along with all plumbing and allied work |
| 2 | Supply,Installation, testing and Commsisoning of 2 KVA automatic voltage stabilizer having input voltage range 90-270 V and Out put volatge range 220V+ 5% (Reputed Make) |
| 3 | Supply,Installation, testing and Commsisoning of commercial water purifier plant,miniumm 60 LPH of reputed make for above water cooler along with necessary connections all complete. (Reputed Make) |
| 4 | Supplying and fixing following size/ modules, GI boxalong with modular base & cover plate for modularswitches in recess etc. as required. 6 Module (200mmX75mm) |
| 5 | Supplying and fixing following modular switch/socket on th existing modular plate and switch box including connections but excluding modular plate etc. 5/6 A Awitch |
| 6 | Supplying and fixing following modular switch/socket on th existing modular plate and switch box including connections but excluding modular plate etc. 15/16 A Switch |
| 7 | Supplying and fixing following modular switch/socket on th existing modular plate and switch box including connections but excluding modular plate etc. 3 pin 5/6 A Socket outlet |
| 8 | Supplying and fixing following modular switch/socket on th existing modular plate and switch box including connections but excluding modular plate etc. 6 pin 15/16 A Socket outlet |
| 9 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A |
| 10 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 4sq mm + 1 X 4 Sq . mm earth wire. |
| 11 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole |
| 12 | Supplying and fixing following size/ modules, GI boxalong with modular base & cover plate for modularswitches in recess etc. as required. 12 Module (200mmX150mm) |
| 13 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed.All kinds of soil (DSR 2.8.1) TT x 6' x 6' x 1'8\\" = 60 cft @1.67/cum X 20 No's |
| 14 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) T1 x 6' x 6' x 2\\" = 5.76 cft @ 0.16/cum X 20 No's |
| 15 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering. All work upto plinth level with: (DSR 4.4.5) 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggrega te 20 mm nominal size) T2 x 5\\"6' x 5\\"6' x 1'6\\" = 45.375 cft @1.28 cum X 20 No's |
| 16 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering. All work upto plinth level with:(DSR 4.4.3) 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) T3 x 5\\" x 5\\" x 1'6\\" = 37.5 cft @ 1.06/cum X 20 No's |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases for columns (4 x ( 5’6” x 1'6\\" )) + (4x(5’x1’6”))+ (4x(6’x2”)) = 33 +30 +4 = 67 sqft or 6.23sqm X 20 No's |
| 18 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. 11.50.1 In colour such as White, Ivory, Grey, Fume Red Brown (5' x 5')+ (4 x 5' x 1'6\\") = 25 +30 =55 X 20 No's |
| 19 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.(DSR 40.25.2) L (50 x 50 x 6) Vm 4 x 8' = 32 Hm 2 x 4 x 5'= 40 Xm 2 x 4 x 5'= 40 Extra 1 x 4 x 1' = 4 2 x 2 x 5' = 20 Flat 40.5mm 25 x 5 = 125 = 41.46 |
| 20 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-incharge. Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade (DSR 16.25.2) (4 x 5' x 5') = 100sqft or 9.29 Sqm |
| 21 | Supply /fixing of Mild steel sheets of 1.00 mm thickness for tanks (complete job) as per direction of engineer in-charge. (8 x 5' x 1.5') = 60 Sqft or 5.57 Sqm @7.86 Kg/m2 |
| 22 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.Concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall:15 mm dia. nominal bore |
| 23 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 15 mm nominal bore |
| 24 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work) 15 mm nominal bore (DSR 19.36.1) |
| 25 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank (DSR 19.38) |
| 26 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 75 mm dia (DSR 12.58.1) |
| 27 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two or more coats on new work (4 x 8' x 5') + (2 x 5' x 5') = 210 Sqft or 19.55 Sqm |
| 28 | Providing and fixing of steel glass and Chain (Complete job) |
| 29 | Removal of Excavated mulba dismantled unserviceable material from the site of work by mech. Transport / Animal Transport or otherwise including loading complete job. TT x 6' x 6' x 1'8\\" = 60 cft @1.67/cum X 20 No's |
| 30 | Carriage of materials by mechanical transport including loading / unloading & stacking complete. Sand/Crusher Dust for an average distance 10 Km by MT |
| 31 | Carriage of materials by mechanical transport including loading / unloading & stacking complete.· Stone aggregate below/above 40mm Nominal size Crushed for an average distance of 10 kms. |
| 32 | Providing and fixing of Single Phase Motor 0.5 HP (Reputed make ) Please Enable Macros to View BoQ information |