| 1 | Work of fabrication and installation of cubical partition and other allied works at Female medicine ward of Medicine department on 6th floor of Dr. R. N. Cooper Hospital. |
| 2 | 4 mm thick Hardener Laminated sheet (Bakelite composite panel) |
| 3 | Aluminum section used |
| 4 | 6 mm thick Plain / frosted / tinted Glass |
| 5 | Providing and fixing in position three track aluminum window of extruded modular and anodized aluminum sections of approved make and of size 92 mm x 45.5 mm x 1.5 mm thk (wt 1.659 kg/Rm) for bottom and 92 mm x 31.75 mm x 1.3mm thk. (wt 0.933 kg/Rm) for top and sides mounted on anodized aluminum rectangular frame of size 100mm x 40mm x 1.3 mm. (Wt 0.976 kg/m) The shutter comprising of bearing bottom and top of size 40mm x 18 mm x 1.25 mm thk (wt. 0.417 Kg/Rm) Interlocking section of size 40mm x 26.7 mm x 1.10 mm thk. (Wt. 0.469 kg./Rm) and hand sides of 40mm x 18mm x 1.25 mm thk (wt. 0.417kg/Rm) with 5 mm thick plain /frosted / tinted glass fixed in shutter including approved quality neoprene gasket, fixtures, fastenings and accessories like PVC rollers, PVC weep holes, locks, handles etc. complete as directed by Engineer In Charge. (Note: anodic film must not be less than 15 microns i.e. AC-15 as per IS, the anodizing must be scaleted by keeping the anodized section in boiling de-anodized water for a period of one hour) |
| 6 | Providing and fixing in position, Double leaf flush door of required size including providing & fixing T.W. frame 60mm x 150mm., 45mm thick solid code hard wood block board shutters with 25mm x 45mm lipping patti, allround the shutter & finished with 1mm thick approved textured laminates on either sides, finishing all exposed surfaces of wood with approved shade french polish, treating all the surfaces of wood in contact with masonary with tar paint (Black Japan), hrominum plated brass fittings & fastenings, S.S. handles etc. complete as per detailed drawing and as directed by the Engineer In charge. D2,D3,GL-D1,GL-D2,GL-D3 |
| 7 | Replacement of Door Closure |
| 8 | Exhaust fan of 230mm sweep, 1400RPM, with 450 CFM free air delivery, AC 230V/415V , 50 Hz, single phase / three phase complete with all necessary accessories for completing installation . |
| 9 | SITC of Medical Grade Copper Tube/Pipes including all type of accessories Like,Tee, Elbow, Valves, etc. complete_Copper Pipes of 15mm OD x 1.0mm thk |
| 10 | SITC of Air curtain of length - 36\\" |
| 11 | Standard Industrial type Fly killer with M.S. body, 4 X 20W tube and approx. area covered: 2000 sq.ft. |
| 12 | SITC of Medical Gas Terminal Units (Gas Outlets) for Oxygen : It shall be duly CE marked /UL listed or equivalent. |
| 13 | SITC of Medical Gas Terminal Units (Gas Outlets) for MA4 Air 4 Bar : It shall be duly CE marked/UL listed or equivalent. |
| 14 | Light /Fan / Ex. fan Points |
| 15 | Providing and fixing 2mm thick Antistatic Vinyl flooring of approved brand, pattern, shade fixed with approved adhesive as per manufacturer's specifications including floor base preparation using epoxy mortar if required. The flooring shall be in roll form etc complete as directed by Engineer In Charge. |
| 16 | Work of removing of existing wooden partition of size (30ft X30ft) & finishing the work for installation of door's and glass of size 6ft X6ft |
| 17 | Shifting of ICU Oxygen- Electrical Panel Please Enable Macros to View BoQ information |