|
| 1 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size Tile 600 x 1200 mm (DSR 2023 11.41A.1.3) |
| 2 | Providing and laying Laminate wooden flooring (Grade AC4 or AC4+ laminates) 6 mm to 12 mm thick, having a good backing layer made up of plastic laminate or melamine, core made up of medium-density fiberboard (MDF),which is less resistant to impact damage and less resistant to being dented by heavy furniture, having a décor dented by heavy furniture, having a décor layer to give each floor its appearance and consisting of one or more sheets of paper impregnated with melamine resin and top wear layer having clear aluminum oxide finish that protects the decorative layer & imparts the desired level of sheen, from full gloss to low gloss, duly fixed to the base floor using adhesive as approved by the manufacturer (CSR 14.101) |
| 3 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/ Semi Matt /Glosy/ Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 450 x 310 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. (CSR 14.127) |
| 4 | Providing and applying Anti Termite Treatment using post constructional chemical treatment measures as per IS - 6313 - 2001 ( Part 3 ) & using Chemical containg chloropyrifos systemic insecticide diluted to manufacturers specifications by drilling holes in the floor slab & along skirting 300 mm apart & 12 mm dia, drilling holes along all possible entry points such as junctions of floor and walls, door frames, sewage lines, entry points , etc. & injecting them with the chemical solution. (CSR 14.132) |
| 5 | Wire gauge Hollock wood door shutter without springs housed in chowkhat (A) 35 mm thick (CSR 17.11 (ii) A) |
| 6 | Providing and fixing bright finished brass 100 mm mortise latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality). (CSR 17.22 (iv) |
| 7 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete (c) I.S.I Designation No. III (size of door 851mm to 1000mm) (CSR 17.43 c) |
| 8 | Providing & fixing 6\\" stainless steel handles ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge. (CSR 17.69) |
| 9 | Providing & fixing 12\\" stainless steel handles ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge. (CSR 17.71) |
| 10 | Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge (ii) 4mm thick ACP Sheet (CSR 17.97 (ii) |
| 11 | Providing & Fixing decorative high pressure laminated sheet 1mm thick High Class Texture with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, ISI marked complete in all respect as per the directions of Engineerin- charge. (CSR 17.92) |
| 12 | Providing & fixing 8\\" stainless steel tower bolts ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge (CSR 17.77) |
| 13 | Providing and fixing of Partal wooden jafri fixed with 3\\" wide strips in wooden frame 3\\"x1½\\" size at top & bottom to hold vertical strip wooden batttens and fixing vertical battens of size 3\\" x ½\\" @ 4.5\\" c/c both sides of frame with nails and screws supported with angle iron 50mmx 50mmx 5mm thick including painting/ priming coat etc. complete in all respect. |
| 14 | Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled (b) Windows of area 3 sqm and below (CSR 8.26 (b) |
| 15 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall fi (CSR 13.55) |
| 16 | Supply & Fixing Fiber Glass Coated Mesh with thickness of 45 Gsm for the water proofing of roof (CSR 13.90) |
| 17 | Water proofing treatment of Roof Slab with High performance cementitious two component product (CSR 13.91) |
| 18 | Supply of Curtain Rod, i/c brackets, final, screws etc., complete in all respect |
| 19 | Providing and fixing of M.S. steel spiral staircase i/c painting complete in all respect. |
| 20 | Providing and fixing of PVC wall paneling 8mm thick as per approved degign complete in all respect |
| 21 | Providing and fixing of cupboard made of 19mm thick commercial board finished with lamination from both sides (including partition and drawers) complete in all respect i/c necessary fittings |
| 22 | Removal of Malba by Mannual labour |
| 23 | Disposal of Malba |
| 24 | Providing and fixing of polycarbonate sheet shed made of 2\\"x2\\" section hollow pipe and 2\\" wide aluminium section for fixing of sheet with rubber gasket and silicon etc. complete in all respect. |
| 25 | Providing and fixing polycarbonate sheet sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws with EPDM seal, and the joints shall be provided with aluminium strips at top and bottom as a seal complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (a) Pollycarbonate sheet Multiwalled 10mm thick (CSR 13.27 (v) (a) |
| 26 | Providing and fixing ply wood, plain lining, butt jointed including PVC Plug placed at 45 cm to 65 cm centers complete with necessary nails (Frame work shall be payable extra) (f) 9mm thick commercial ply wood (CSR 17.32 f) |
| 27 | Chowkats of commercial hard wood such as Hollock confirming to ISI specification no 1003 m kiln seasoned of doors and windows including iron hold fasts, corner straps cleats, stops, bolts for hold fasts etc, complete fixed in position (Section 60mm x 150mm) (A) Double Rebate (60mm x 150mm) (60mm x 150mm) (CSR 17.15 (ii) A) |
| 28 | Wire gauge Hollock wood door shutter without springs housed in chowkhat. (A) 35 mm thick (CSR 17.11 (ii) A) |
| 29 | Hollock wood doors shutter windows shutter including hinges, screws, chocks, cheats, stops cords etc. complete fixed in position. (a) panelled, glazed or glazed and panelled. (ii) 35 mm thick (CSR 17.10(xvii) (ii) |
| 30 | Renewing glass panes with wooden fillets wherever necessary (b) Glass panes weighing 10.75 Kg/sqm (CSR 31.6 (b) |
| 31 | Renewing glass panes with wooden fillets wherever necessary (c) Frosted glass Panes weighing 8.44Kg/sqm (CSR 31.6 (c) |
| 32 | Providing & fixing 4\\" stainless steel hinges ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge |
| 33 | Providing & fixing 9\\" stainless steel handles ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge (CSR 17.70) |
| 34 | Providing & fixing stainless steel dead lock ISI marked on door frames complete in all respect as per the directions of Engineer-in-charge |
| 35 | Providing & fixing 4\\" stainless steel tower bolts ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge (CSR 17.75) |
| 36 | Providing & fixing stainless steel catcher ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge Please Enable Macros to View BoQ information |