Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminum round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. |
| 2 | Short point (up to 3 mtr.) |
| 3 | Medium point (up to 6 mtr.) |
| 4 | Long point (up to 10 mtr.) |
| 5 | Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminium round tiles, 2 Nos Hot Dipped Galvanized M.S Modular box of 1.2 mm thick with earth terminal,2 Nos 6 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate, screws, making connections, testing etc. as required. |
| 6 | Short point (up to 3 mtr.) |
| 7 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 6 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. |
| 8 | On board |
| 9 | Short point (up to 3 mtr.) |
| 10 | Medium point (up to 6 mtr.) |
| 11 | Long point (up to 10 mtr..) |
| 12 | S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including making jhiri in the wall,clamps at suitable spacing, covering conduit and making good the same as required. |
| 13 | 20 mm |
| 14 | 25 mm |
| 15 | 32 mm |
| 16 | 40 mm |
| 17 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminium round tiles, 1.2 mm thick Hot dipped Galavanized MS box with earth terminal, 6 A switch, 3 pin ceiling rose/holder / 3 way connector , 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required. |
| 18 | Short point (up to 3 mtr.) |
| 19 | Medium point (up to 6 mtr.) |
| 20 | Long point (up to 10 mtr.) |
| 21 | Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminium round tiles, 2 Nos 1.2 mm thick Hot dipped Galavanized MS box with earth terminal, 2 Nos 6 A two way switch,3 pin ceiling rose / holder/ 3 way connector, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required. |
| 22 | Short point (up to 3 mtr.) |
| 23 | Medium point (up to 6 mtr.) |
| 24 | Long point (up to 10 mtr..) |
| 25 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, 1.2 mm thick Hot dipped Galavanized MS box with earth terminal of required size, 6 A switch, 3/5 pin 6 A socket, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required. |
| 26 | On board |
| 27 | Short point (up to 3 mtr.) |
| 28 | Medium point (up to 6 mtr.) |
| 29 | Long point (up to 10 mtr..) |
| 30 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked ( IS:14927 P - II ) uPVC trunking & it's accessories, Hot Dipped Galvanized Modular box 1.2 mm thick with earth terminal/ Surface mounted UPVC molded modular box, 6 A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose/holder /3 way Connector, screws, making connections, testing etc. as required. |
| 31 | Short point (up to 3 mtr.) |
| 32 | Medium point (up to 6 mtr.) |
| 33 | Long point (up to 10 mtr.) |
| 34 | Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) of approved make on surface ISI marked ( IS:14927 P - II ) uPVC trunking & it's accessories, 2 No. Hot Dipped Galvanized Modular box 1.2 mm thick with earth terminal/ 2 No. Surface mounted UPVC molded modular box, 2 Nos 6 A two way Modular switch, 3 pin ceiling rose / holder/3 way Connector , Modular face plate with grid plate, screws, making connections, testing etc. as required |
| 35 | Short point (up to 3 mtr.) |
| 36 | Medium point (up to 6 mtr.) |
| 37 | Long point (up to 10 mtr..) |
| 38 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) on surface ISI marked ( IS:14927 P - II ) uPVC trunking & it's accessories, Hot Dipped Galvanized Modular box 1.2 mm thick with earth terminal/Surface mounted UPVC molded modular box, modular 6 A switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required |
| 39 | On board |
| 40 | Short point (up to 3 mtr.) |
| 41 | Medium point (up to 6 mtr.) |
| 42 | Long point (up to 10 mtr..) |
| 43 | S&F following sizes of ISI marked ( IS:14927 P - II ) uPVC trunking along with accessories like coupler, inner, outer, elbow, square box, tee, end cap etc. on surface with screws, expansion fasteners etc. as required. |
| 44 | 20 mm x 12 mm |
| 45 | 25 mm x 12 mm |
| 46 | 32 mm x 12 mm |
| 47 | 25 mm x 16 mm |
| 48 | 38 mm x 16 mm |
| 49 | 38 mm x 25 mm |
| 50 | 38 mm x 38 mm |
| 51 | 50 mm x 16 mm |
| 52 | 50 mm x 50 mm |
| 53 | 75 mm x 50 mm |
| 54 | 75 mm x 75 mm |
| 55 | 100 mm x 50 mm |
| 56 | 100 mm x 100 mm |
| 57 | Supplying and laying FR PVC insulated & unsheathed flexible copper conductor of following nominal sizes with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. |
| 58 | 1 x 1.5 sq.mm |
| 59 | 2 x 1.5 sq.mm |
| 60 | 3x 1.5 sq.mm |
| 61 | 4 x 1.5 sq.mm |
| 62 | 1 x 2.5 sq.mm |
| 63 | 2 x 2.5 sq.mm |
| 64 | 2 x 2.5 sq. mm. + 1x1.5sqmm |
| 65 | 3 x 2.5 sq.mm |
| 66 | 4 x 2.5 sq.mm |
| 67 | 1 x 4.0 sq.mm |
| 68 | 2 x 4.0 sq.mm |
| 69 | 3 x 4 sq. mm. |
| 70 | 4 x 4.0 sq.mm |
| 71 | 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. |
| 72 | 1 x 6.0 sq.mm |
| 73 | 2 x 6.0 sq.mm |
| 74 | 3 x 6.0 sq. mm. |
| 75 | 4 x 6.0 sq.mm |
| 76 | 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. |
| 77 | 2 x 6.0 sq. mm. + 1 x 4.0 sq. mm. |
| 78 | 1 x 10.0 sq.mm |
| 79 | 2 x 10.0 sq.mm |
| 80 | 4 x 10.0 sq.mm |
| 81 | 1 x 16.0 sq.mm |
| 82 | 2 x 16.0 sq.mm |
| 83 | Supplying and Laying coaxial cable 75 ohm impedance with foam PE insulated solid bare copper inner conductor, and Ist outer conductor of bonded alum. tape and second outer conductor of alum. alloy braid in existing surface or recessed conduit/casing capping including making connections as required. |
| 84 | RG - 6 |
| 85 | RG -11 |
| 86 | Supplying and Laying PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 & confirming to TEC specification GR / WIR/06-03 March 2002 in existing surface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. |
| 87 | 2 pair |
| 88 | 4 pair |
| 89 | 5 pair |
| 90 | 10 pair |
| 91 | 20 pair |
| 92 | 50 pair |
| 93 | 100 pair |
| 94 | 200 pair |
| 95 | 100 pair |
| 96 | 200 pair |
| 97 | Supply and Laying of PE Insulated, PVC Inner Sheathed, armoured & PVC Sheathed Telephone Cable. with 0.5 mm thick Solid Annealed Bare Copper Conductor as per IS: 8130/84 telephone cable confirming to TEC specifications GR/WIR 06/03, Mar.-2002 in existing pipe / open trench / Cable tray / on surface including making necessary connection, testing etc. as required of size. |
| 98 | 5 pair |
| 99 | 10 pair |
| 100 | 20 pair |
| 101 | 50 pair |
| 102 | 100 pair |
| 103 | 200 pair |
| 104 | Supply and Laying of PE Insulated jelly filled Armoured Telephone Cable. with 0.6 mm thick Solid Annealed Bare Copper Conductor and confirming to TEC specifications confirming. to DOT GR/CUG-01/Aug.2003 in existing pipe / open trench / Cable tray / on surface including making necessary connection, testing etc. as required of size. |
| 105 | 5 pair |
| 106 | 10 pair |
| 107 | 20 pair |
| 108 | 50 pair |
| 109 | 100 pair |
| 110 | 200 pair |
| 111 | Supply & laying service connection with ISI marked (IS:694) 1100 Volts grade PVC insulated flat twin core sheathed solid aluminium conductor with 10 SWG G.I. Support wire duly clipped etc. as required. |
| 112 | 2.5sq.mm |
| 113 | 4.0 sq.mm |
| 114 | 6.0 sq.mm |
| 115 | 10.0 sq.mm |
| 116 | Supply and Laying ISI marked P.V.C. insulated submersible cable confirming to(IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, existing pipe / open trench / Cable tray / on surface including making connection etc. as required. |
| 117 | 1.5 Sq.mm 3 core flat / Round |
| 118 | 2.5 Sq.mm 3 core flat / Round |
| 119 | 4.0 Sq.mm 3 core flat / Round |
| 120 | Supply and laying following size twin parallel type Speaker cables made with multi wire, bright annealed flexible bare electrolytic grade copper conductor, insulated with specially formulated transparent grade PVC compound, red strip for identification in existing conduit etc. as required. |
| 121 | 0.75 sq.mm |
| 122 | 1.0 Sq. mm |
| 123 | 1.5 Sq.mm |
| 124 | 2.5 Sq.mm |
| 125 | Supply and laying speaker cable of following size 2 core twin twisted multi stranded electrolytic grade copper conductor, overall PVC insulated and armoured cable (Blue colour) on surface/ above false ceiling including cost of GI spacers, saddles etc. as required. |
| 126 | 0.75 sq.mm |
| 127 | 1.0 Sq. mm |
| 128 | 1.5 Sq.mm |
| 129 | 2.5 Sq.mm |
| 130 | Supply and laying PVC Insulated and PVC Round Sheathed Multi Core copper conductor (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing pipe / open trench / Cable tray / on surface including making connection etc. as required. |
| 131 | 1.5 sq.mm x 3 core |
| 132 | 1.5 sq.mm x 4 core |
| 133 | 1.5 sq.mm x 6 core |
| 134 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanism , energy limiting of class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating, 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. |
| 135 | Single pole MCB (With B / C curve tripping characteristics) |
| 136 | 0.5 A to 5 A rating |
| 137 | 6 A to 32 A rating |
| 138 | 40 A rating |
| 139 | 50/63 A rating |
| 140 | 80 A rating |
| 141 | 100 A rating |
| 142 | 125 A rating |
| 143 | Double pole MCB (With B / C curve tripping characteristics) |
| 144 | 0.5 A to 5 A rating |
| 145 | 6 A to 32 A rating |
| 146 | 40 A rating |
| 147 | 50/63 A rating |
| 148 | 80 A rating |
| 149 | 100 A rating |
| 150 | 125 A rating |
| 151 | Triple pole MCB (With B / C curve tripping characteristics) |
| 152 | 0.5A to 5 A rating |
| 153 | 6 A to 32 A rating |
| 154 | 40 A rating |
| 155 | 50/63 A rating |
| 156 | Four pole MCB (With B / C curve tripping characteristics) |
| 157 | 0.5A to 5 A rating |
| 158 | 6 A to 32 A rating |
| 159 | 40 A rating |
| 160 | 50/63 A rating |
| 161 | Triple pole MCB (With D curve tripping Characteristics) |
| 162 | 0.5 A to 5 A rating |
| 163 | 6 A to 32 A rating |
| 164 | 40 A rating |
| 165 | 50/63 A rating |
| 166 | Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door (Metal / Glazed / Acrylic) Distribution board with Metal end box made out from Galvanized steel / CRCA sheet, powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, complete with 100 amp. insulated copper bus bar/shorting link , brass neutral link with shrouds, brass earth link , door earthing arrangement, color coded interconnecting wire set of minimum 10.0 sqmm size and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. |
| 167 | Metal door (single phase) IK-09 and IP-43 with Metal end box |
| 168 | 4 Way |
| 169 | 6 Way |
| 170 | 8 Way |
| 171 | 12 Way |
| 172 | 16 Way |
| 173 | Glazed / Acrylic door (single phase) IK-09 and IP-43 with Metal end box |
| 174 | 4 Way |
| 175 | 6 Way |
| 176 | 8 Way |
| 177 | 12 Way |
| 178 | 16 Way |
| 179 | Metal door (Three phase) IK-09 and IP-43 with Metal end box |
| 180 | 4 Way (8 incomer + 12 Outgoing) |
| 181 | 6 Way (8 incomer + 18 Outgoing) |
| 182 | 8 Way (8 incomer + 24 Outgoing) |
| 183 | 12 Way (8 incomer + 36 Outgoing) |
| 184 | Glazed / Acrylic door (Three phase) IK-09 and IP-43 with Metal end box |
| 185 | 4 Way (8 incomer + 12 Outgoing) |
| 186 | 6 Way (8 incomer + 18 Outgoing) |
| 187 | 8 Way (8 incomer + 24 Outgoing) |
| 188 | 12 Way (8 incomer + 36 Outgoing) |
| 189 | Providing & Fixing of Recessed/surface mounting heavy duty Flexi / Row type Distribution board with Metal end box made out from Galvanized steel / CRCA sheet , powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3 complete with 100 Amp. copper shorting link , brass neutral link with shrouds, brass earth link , color coded interconnecting wire set of suitable rating and din bar, door earthing arrangement, masking sheet, making internal DB terminations with copper lugs, ferrules detachable gland plate, including making connections, testing etc. as required. |
| 190 | Double door IK-09 & IP-43 with metal End box |
| 191 | 4 Row 32 Module(8 module per row) |
| 192 | 4 Row 40 Module(10 module per row) |
| 193 | 4 Row 56 Module(14 module per row) |
| 194 | 3 Row 42 Module(14 module per row) with provision of 160 Amp. MCCB |
| 195 | Providing & Fixing of Recessed/surface mounting heavy duty Flexi / Row type Distribution board with Metal end box made out from Galvanized steel / CRCA sheet , powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3 complete with 100 Amp. copper shorting link , brass neutral link with shrouds, brass earth link , color coded interconnecting wire set of suitable rating and din bar, door earthing arrangement, masking sheet, making internal DB terminations with copper lugs, ferrules detachable gland plate, including making connections, testing etc. as required. |
| 196 | Double door IK-09 & IP-43 with metal End box |
| 197 | 4 Row 32 Module(8 module per row) |
| 198 | 4 Row 40 Module(10 module per row) |
| 199 | 4 Row 56 Module(14 module per row) |
| 200 | 3 Row 42 Module(14 module per row) with provision of 160 Amp. MCCB |
| 201 | Glazed / Acrylic door IK-09 & IP-43 with Metal End Box |
| 202 | 4 Row 32 Module(8 module per row) |
| 203 | 4 Row 40 Module(10 module per row) |
| 204 | 4 Row 56 Module(14 module per row) |
| 205 | P&F metal clad / Polyamide industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet , powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. (without MCB) including making connections, testing etc.as required. |
| 206 | 20 amp, (2P + E), 1 Module |
| 207 | 20 amp, (2P + E), 2 Module |
| 208 | 20 amp, (2P + E), 3 Module |
| 209 | 32 amp, (3P + E), 3 Module |
| 210 | 32 amp, (3P + N + E) 8 Module (with Polyamide Plug & Socket) |
| 211 | 63 amp, (3P + N+ E), 8 Module (with Polyamide Plug & Socket) |
| 212 | P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. |
| 213 | IP -67, IK - 09 Panel mounted socket |
| 214 | 16 A (2P+E) |
| 215 | 32 A (2P+E) |
| 216 | 32 A (3P+N+E) |
| 217 | 63 A (3P+N+E) |
| 218 | IP -67, IK-09 Surface/Wall mounted socket |
| 219 | 16 A (2P+E) |
| 220 | 32 A (2P+E) |
| 221 | 32 A (3P+N+E) |
| 222 | 63 A (3P+N+E) |
| 223 | IP -66, Surface/Wall mounted Interlocked switched socket Outlet with Provision of MCB |
| 224 | 16 A (2P+E) 250 V |
| 225 | 32 A (2P+E), 250 V |
| 226 | 32 A (3P+E), 415 V |
| 227 | IP - 67 Plug top |
| 228 | 16 A (2P+E) |
| 229 | 32 A (2P+E) |
| 230 | 32 A (3P+E) |
| 231 | 32 A (3P+N+E) |
| 232 | Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for MCB / RCCB/ RCBO up to 63 Amp and SP / TP MCB upto 32 Amp. as outgoing ,made out from Galvanized steel / CRCA sheet, powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3 complete with insulated 100 A rating copper bus bar, brass neutral bars with shrouds, brass earth bar , color coded interconnecting wire set of suitable rating and din bar, door earthing arrangement, masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. |
| 233 | Double door IK-09 & IP-43 with Metal end box |
| 234 | 4 Way (8 Incomer +12 Outgoing) |
| 235 | 6 Way (8 Incomer +18 Outgoing) |
| 236 | 8 Way (8 Incomer +24 Outgoing) |
| 237 | 12 Way (8 Incomer + 36 Outgoing) |
| 238 | Double door IP-43 & IK-09 with Provision of Incomer MCCB up to 125 A Rating with Metal end box |
| 239 | 4 Way |
| 240 | 6 Way |
| 241 | 8 Way |
| 242 | 12 Way |
| 243 | Double door IP-43 & IK-09 with Provision of Incomer MCCB 160 A Rating with Metal End Box |
| 244 | 4 Way |
| 245 | 6 Way |
| 246 | 8 Way |
| 247 | 12 Way |
| 248 | Double door IP-43 & IK-09 with Provision of Incomer MCCB 200/250 A Rating with metal End Box |
| 249 | 4 Way |
| 250 | 6 Way |
| 251 | 8 Way |
| 252 | 12 Way |
| 253 | P & F Surface mounting IP-65, IK-09 Class-II self extinguishing insulating material weather proof cabinets confirming to EN60439-3 with IP-65 Key lock, fully reversible door and cabinet, removable chasis and face plates, of following size. |
| 254 | 3/4 module |
| 255 | 6 module |
| 256 | 8 module |
| 257 | 1 row 12 module |
| 258 | 2 row 24 module |
| 259 | 3 row 36 module |
| 260 | P & F ISI marked (IS:3854) 6 amp. flush type non modular switch with CM/L no. printed and made out from industrial grade Polycarbonate material including cutting hole in tile and making connection testing etc. as required. |
| 261 | P & F ISI marked (IS :3854) 16 amp. flush type non modular switch CM/L no. printed and made out from industrial grade Polycarbonate material including cutting hole in tile and making connection testing etc. as required. |
| 262 | Providing & Fixing of 6 amp. Combined flush type non modular socket and switch set made out from industrial grade Polycarbonate material including cutting hole in tile and making connection testing etc. as required. |
| 263 | Providing & Fixing of 16 amp. Combined flush type non modular socket and switch set with indicator and fuse set, made out from industrial grade Polycarbonate material including cutting hole in tile and making connection testing etc. as required. |
| 264 | Providing & Fixing of ISI marked (IS :3854) non modular 6A bell push surface type CM/L no. printed and made out from industrial grade Polycarbonate material including making connection testing etc. as required. |
| 265 | Providing & Fixing of ISI marked (IS :3854) twin control non modular 6A switch surface type, CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal & captive screws including making connection testing etc. as required. |
| 266 | Providing & Fixing of ISI marked (IS :3854) non modular 6A bell push flush type CM/L no. printed and made out from industrial grade Polycarbonate materialincluding cutting hole in tile and making connection testing etc. as required. |
| 267 | Providing & Fixing of ISI marked (IS :3854) twin control non modular 6A switch flush type CM/L no. printed , made out from industrial grade Polycarbonate material, including cutting hole in tile and making connection testing etc. as required. |
| 268 | Providing & Fixing of non modular 6A hanging bell push/one way switch made out from industrial grade Polycarbonate material including making connection testing etc. as required. |
| 269 | Providing & Fixing of IS:1293 marked of 3 pin 6 amp. flush type non modular socket CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal with Porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required. |
| 270 | Providing & Fixing of IS:1293 3/6 pin 16 amp flush type non modular socket CM/L no. printed and made out from Industrial grade Polycarbonate material, brass terminal with Porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required. |
| 271 | Providing & Fixing of ISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal & captive screws including making connection testing etc. as required. |
| 272 | Providing & Fixing of ISI marked (IS:1258) batten/angle lamp holder with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal & captive screws including making connection testing etc. as required. |
| 273 | Providing & Fixing of ISI marked (IS:1293) 6 amp unbreakable 3 pin plug top having lamp indicator with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal including making connection testing etc. as required. |
| 274 | Providing & Fixing of ISI marked (IS:1293) 16 amp unbreakable 3 pin plug top having lamp indicator with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal including making connection testing etc. as required. |
| 275 | Providing & Fixing of flush type non modular 2 pin telephone socket with plug top made out from industrial grade Polycarbonate material, brass terminals including making connection testing etc. as required. |
| 276 | Providing & Fixing of flush type non modular single line telephone jack made out from industrial grade Polycarbonate material, including making connection testing etc. as required. |
| 277 | Providing & Fixing of flush type non modular double line telephone jack made out from industrial grade Polycarbonate materialincluding making connection testing etc. as required. |
| 278 | Providing & Fixing of flush type non modular coaxial T.V. socket made out from industrial grade Polycarbonate material,including making connection testing etc. as required. |
| 279 | Providing & Fixing of IS 11037 marked non modular socket size flush type 100 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial grade Polycarbonate material including making connection testing etc. as required. |
| 280 | P & F ISI marked 32 A D.P. switch with fuse and indicating lamp including making connection testing etc. as required. |
| 281 | Providing & Fixing of ISI marked (IS:302) gong bell with CM/L no. printed including making connection testing etc. as required. |
| 282 | Providing & Fixing of single / multi tone electronic call bell / remote bell including making connection testing etc. as required. |
| 283 | Providing & Fixing of ISI marked (IS:302) ding dong/musical chime bell including making connection testing etc. as required. |
| 284 | Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant virgin UV Stabilized Polycarbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating ,minimum width of switch toggle( PUSH PART ) should not less then 20mm, including making connections, testing etc as required. |
| 285 | 10 A one way switch |
| 286 | 10 A two way switch |
| 287 | 16 A one way switch 1M |
| 288 | 20 A one way switch 1M |
| 289 | 20 A one way switch 2M |
| 290 | 16 Amp. 2 Module switch With Led Indicator |
| 291 | 32 Amp. 2 Module switch With Led Indicator |
| 292 | Providing & Fixing of IS:1293 marked modular type lockable feature socket with CM/L no. printed duly made out of unbreakable and fire retardant virgin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating, including making connections, testing etc as required. |
| 293 | 6 A 3 pin shuttered socket |
| 294 | 6/16 A shuttered socket |
| 295 | 13 A flat pin international socket (Non ISI) |
| 296 | Providing & Fixing of modular type 100W Step Fan regulator duly ISI marked (IS 11037) with CM/L no. printed made out of unbreakable and fire retardant virgin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including making connections, testing etc as required. |
| 297 | 5 step fan regulator 2 Module |
| 298 | Providing & Fixing of following modular accessories, made out of unbreakable and fire retardant virgin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating, including making connections, testing etc as required. |
| 299 | RJ-11 telephone jack single line |
| 300 | RJ-11 telephone jack Double line |
| 301 | USB Charger 2 A - 1 M with BIS mark |
| 302 | RJ-45, Cat 6 computer jack with shutter |
| 303 | T.V. coaxial socket |
| 304 | Blanking plate |
| 305 | 25 Amp. 2 Module Motor Starter with on / off Push button |
| 306 | LED Skirting /Foot Light 2 Module |
| 307 | Electronic Chime/Buzzer 2M |
| 308 | Modular MCB 6 A to 32 A SP |
| 309 | Modular MCB 6 A to 32 A DP |
| 310 | Providing & Fixing of following size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect. |
| 311 | 1/2 Module |
| 312 | 3 Module |
| 313 | 4 Module |
| 314 | 5 Module |
| 315 | 6 Module |
| 316 | 8 Module |
| 317 | 10 Module |
| 318 | 12 Module |
| 319 | 16/18 Module |
| 320 | Providing & Fixing of Hot dipped Galvanized metal box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess/ surface suitable for modular accessories as required. |
| 321 | 1-2 Module |
| 322 | 3 Module |
| 323 | 4-5 Module |
| 324 | 6-8 Module |
| 325 | 10-12 Module |
| 326 | 16/18 Module |
| 327 | Providing & Fixing of Wiring Accessories OEM fabricated following size virgin material UPVC modular boxes on surface suitable for modular accessories as required. |
| 328 | 1-2 Module |
| 329 | 3 Module |
| 330 | 4/5 Module |
| 331 | 6 / 8 module |
| 332 | 10 / 12 module |
| 333 | Providing & Fixing of Multiple socket with surge and spikes protection cartridge not less then 5 KV with minimum four nos. universal 6 A sockets, one 6 A switch and 3 pin company fitted plug top and 3 core multistrand copper lead minimum 1.5 mtr. including making connection etc as required. |
| 334 | Providing & Fixing of DLP PVC adaptable trunking system for cable management including finishing accessories like corners, tees, adjustable angles, junction etc. as required . The trunking system shall have adaptable system for modular type RJ 45 data socket/ wiring accessories/ power sockets and shall be covered with peal off plastic cover. OEM have to submit NABL accrediated /CPET lab test reports /EN 50085-2-1 complaince certificate. |
| 335 | 80mm x 50mm |
| 336 | 100/105mm x 50mm |
| 337 | 150/160mm x 50mm |
| 338 | 195/200mm x 50mm |
| 339 | Providing and fixing of power plug point with non modular accessories with Galvanized box of 1.2 mm thick with earth terminal with suitable size 3.0 mm thick phenolic laminated sheet (IS : 2036 - 1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outlet making connection , testing , etc. as required. |
| 340 | Supplying and fixing of power plug point with Modular accessories on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. |
| 341 | P & F Krone module with base frame in the recess / surface made out of 1.2 mm thick sheet steel box, front openable, having locking arrangements duly powder coated ,including dressing, ferruling and punching of telephone cable with krone tool etc. as required. |
| 342 | 10 Pairs |
| 343 | 20 Pairs |
| 344 | 50 Pairs |
| 345 | 100 Pairs |
| 346 | 200 Pairs |
| 347 | SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- |
| 348 | (a) Thickness of CRCA sheet shall not be less than 1.6 mm upto 450 mm length/ width of any compartment and be 2.0 mm above 450 mm, load bearing structure shall be 2.0 mm thick sheet supported by base M.S. channel if required, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided |
| 349 | (b) complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side(Inner & Outer side) of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. |
| 350 | [c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra ) |
| 351 | (d) Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. |
| 352 | (e) All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. |
| 353 | (f) Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra ) |
| 354 | (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. |
| 355 | (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI type Test certificates for Temp. rise test, Short circuit test for 50 kA and IP test is to be submitted) |
| 356 | Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator, with short circuit withstand capacity of 31 MVA for 1 Sec. , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. |
| 357 | Electrolytic grade Aluminium bus bar 6010 grade |
| 358 | Electrolytic grade (Cu+ETP) Tin Coated annealed copper bus bars IACS 100% grade. |
| 359 | Providing & Fixing of IS: 13875 & IEC :61326/IEC:62053-22 confirming LED Digital type (up to 500) V range Volt meter / Direct- Ammeter / CT opertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracy of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. |
| 360 | Single Phase Ammeter |
| 361 | Single Phase Voltmeter |
| 362 | Three phase Ammeter with Inbuilt Selector Switch |
| 363 | Three phase Voltmeter with Inbuilt Selector Switch |
| 364 | Three phase KWH Meter |
| 365 | Three phase KWH Meter Dual Source |
| 366 | Frequency Meter |
| 367 | Three phase AMP+HZ+PF+KW+KVA+KVAR+T.ENERGY+THD-I, THD-V & RUN HRS Meter |
| 368 | Three phase AMP + HZ + PF + KW + KVA + KVAR + KVARH+KWH+DUAL ENERGY+ ENERGY+THD-I, THD-V & RUN HRS Meter |
| 369 | Three phase with universal Auxiliary supply + AMP + HZ + PF + KW + KVA + KVAR + KVARH + KWH + DUAL ENERGY+ ENERGY+THD-I, THD-V & RUN HRS + MD with RS485 Meter |
| 370 | Providing & Fixing of Current Transformer confirming IS 2705-I (1992) with secondary terminal and shorting Block , with all necessary support in existing panel including connection etc. as required Current transformer Ring Type Tape Wound/Resin Cast Wound Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . |
| 371 | Ring type tape wound CT |
| 372 | C T Class 1, Ratio up to 150/5, Burden 5 VA |
| 373 | C T Class 1, Ratio 200/5 to 600/5, Burden 10 VA |
| 374 | C T Class 1, Ratio 800/5 to 1200/5, Burden 15 VA |
| 375 | C T Class 1, Ratio 1500/5 to 3000/5, Burden 15 VA |
| 376 | C T Class 1, Ratio 3200/5 to 5000/5, Burden 15 VA |
| 377 | Resin cast wound type CT |
| 378 | C T Class 1, Ratio up to 150/5, Burden 5 VA |
| 379 | C T Class 1, Ratio 200/5 to 600/5, Burden 15 VA |
| 380 | C T Class 1, Ratio 800/5 to 1200/5, Burden 15 VA |
| 381 | C T Class 1, Ratio 1600/5 to 3000/5, Burden 15 VA |
| 382 | C T Class 1, Ratio 4000/5 to 5000/5, Burden 15 VA |
| 383 | Providing & Fixing of selector switch of 10 A for voltmeter using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range 25 degree C to 55 degree C, frequency upto 10 KHz. Switch life under standard operating conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc. as required . |
| 384 | Voltage Between Phases with OFF ( 4 Position ) |
| 385 | Voltage Between Phases & Individual Phases to Neutral with OFF ( 7 Position ) |
| 386 | Providing & Fixing of CT linked selector switch of 10 A for Ampere meter (4 position ) using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range 25 degree C to 55 degree C, frequency upto 10 KHz. switch life under standard operating conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour , including making connection etc. as required . |
| 387 | Providing & Fixing of 10 A Cam operated rotary (Local- Remote, Auto - manual) switches on existing panel with 1 pole 2 way and off position using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc. as required . |
| 388 | All in all comprehensive maintenance of mono block / submersible motor pump set with starter panel etc. complete in all respect |
| 389 | Sub mersible Motor pump set |
| 390 | Rewinding of ceiling fan motor (starting and running winding) including all necessary material. The motor is to be wound taking no. of coils, turns and pitch as it was originally wound with required size super enamelled wire with 'E' class insulation material and making connections etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. (New model ceiling fan) |
| 391 | 900/1200 mm sweep (New model ceiling fan) |
| 392 | Labour charges for removing and refixing of Ceiling fan/ Exhaust fan from site |
| 393 | Providing & Fixing of Electrical insulating rubber matts confirming to IS: 15652 / 2006 with one side anti skid aberration marks and pasting the mat with synthetic rubber adhesive as required. |
| 394 | 3.3 KV, class A 2 mm thick with proof voltage 10 KV AC (rms) and Break Down Voltage 30 KV AC (rms) |
| 395 | 11 KV, Class B 2.5 mm thick with proof voltage 22 KV AC (rms) and Break Down Voltage 45 KV AC (rms) |
| 396 | Providing & Fixing of self healing IP20 MPP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 OR IEC : 60831-1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz, Operating loss less than 0.30 Watt per KVAR. Min over current capacity 1.8 times rated current & peak inrush current min. 300 times of rated current, life expectancy greater than 100000hrs (temp class - 25 D) in 440 V including making connections, testing etc. as required. |
| 397 | Heavy duty Three phase 440 V, 50 Hz cylindrical type capacitor (Bank) |
| 398 | Heavy duty Three phase 525V, 50 Hz cylindrical type capacitor (Bank) |
| 399 | Providing & Fixing of 3-Phase 415/440 V , 7 % / 14 % Detuned Reactors conforming to IEC 61558-2-20 & IEC 60076-6 Aluminium wound for harmonics filter with 180% to 200 % Linearity, H - Class Insulation ( 180 degree C), high temp. Disconnection above 155 deg C., ambient temperature: +60 deg C. with thermal cut off switch in existing panel with following Capacitor ratings. including making connections, testing etc. as required. |
| 400 | 7 % (189 Hz) Aluminium wound Reactors |
| 401 | For 1 to 5 KVAR capacitor |
| 402 | 10 KVAR |
| 403 | 12.5 KVAR |
| 404 | 15 KVAR |
| 405 | 20 KVAR |
| 406 | 25 KVAR |
| 407 | 50 KVAR |
| 408 | 100 KVAR |
| 409 | 14 % (133 Hz) Aluminium wound Reactors |
| 410 | For 1 to 5 KVAR capacitor |
| 411 | 10 KVAR |
| 412 | 12.5 KVAR |
| 413 | 15 KVAR |
| 414 | 20 KVAR |
| 415 | 25 KVAR |
| 416 | 50 KVAR |
| 417 | 100 KVAR |
| 418 | Providing & Fixing of microprocessor based 3 CT’s for all 3 phase sensing compensation power factor correction relay with Approx. Size 139 mm x 139 mm, Operating Voltage 415/440 V , IEC / EN 61000-6-(2&4) having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analyzing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, High voltage, THD-I & THD-V insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi Built in MFM with PF Controller LCD Display, CT polarity auto correction % THD up to 30 harmonics level, step switching time 2 sec to 1800 sec. Lead & Lag parameters, metering facility and 3 no. Class- 0.5 Cast Resin CT for sensing the relay including making connection with 1.5 Sq.mm copper wire etc. as required. |
| 419 | 6 to 8 stage |
| 420 | 12 to 16 stage |
| 421 | Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor confirming to IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. |
| 422 | 4 pole Power contactors with following AC 1 Rating |
| 423 | 16 Amp. |
| 424 | 25/32 Amp. |
| 425 | 40 Amp |
| 426 | 50/55 Amp |
| 427 | 63 Amp |
| 428 | 100/105 Amp |
| 429 | 160 Amp |
| 430 | 200 Amp |
| 431 | 250 Amp |
| 432 | 325 Amp |
| 433 | 400 Amp |
| 434 | Providing & Fixing of 440 Volt 3 pole capacitor (AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current as per IS/IEC 60947-4-1 : 2000, insulation voltage 1000V, impulse withstand voltage 8 KV,Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank. |
| 435 | up to 6 KVAR |
| 436 | 8.5 KVAR |
| 437 | 10 KVAR |
| 438 | 12.5 KVAR |
| 439 | 15.0 KVAR |
| 440 | 20.0 KVAR |
| 441 | 25.0 KVAR |
| 442 | 30.0 KVAR |
| 443 | 40.0 KVAR |
| 444 | 50.0 KVAR |
| 445 | 60.0 KVAR |
| 446 | 75.0 KVAR |
| 447 | 85 KVAR |
| 448 | 100 KVAR |
| 449 | P & F of Control relays (Auxiliary Contactor) for AC control standard. 24 V Coil 110, 240 V, 415 V, 50 Hz conforming to IS:13947-4-1/IEC:60947-4-1 with required NO & NC combination including making connections, testing etc. as required. |
| 450 | P & F of Front / Side mounting Add on Auxiliary Contact Block with required NO & NC combination including making connections, testing etc. as required. |
| 451 | Providing & Fixing of thermal over load relay with built in single phase protection and having at least 1NO & 1NC contacts, manual /auto reset facility including making connection testing etc. as required. |
| 452 | Up to 14 Amp |
| 453 | 14 to 23 Amp |
| 454 | 20 to 33 Amp |
| 455 | 24 to 40 Amp |
| 456 | P & F of 240 / 415 V Electronic ON - OFF Timer 3 -30 Sec / 12 - 120 Sec including making Connection etc. as required. |
| 457 | Providing & Fixing of Electromechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming conforming to IEC 60730-1 and 60730-2-7 etc. as required. |
| 458 | One day reserve (Electromechanical type ) |
| 459 | One day & week reserve (digital type ) |
| 460 | Providing & Fixing of 110 - 240 V, AC, 1 ph. , 2 W Astronomical time switch with surge suppressor, memory card, Sunrise / Sunset selectable, software for programming including making connection, etc. as required. |
| 461 | Providing & Fixing of IP54 direct or CT operated, 1x240 / 3x240 volts , 50 Hz static watt-hour meter (kwh) , having resolution 0.1 / 0.01 kwh , confirming to IS:13779/ IS:15959, LED indicators for tamper operation ( Reverse &/or earth connection) , pulsating LED indicator for meterology , LCD Display, cover plate for body and terminal sealing , push button for all standard parameters, including making connection ,testing etc. as required. |
| 462 | up to 30 ampere single phase meter acc. Cl 1 |
| 463 | 10 A to 60 ampere Single phase meter acc. Cl 1 |
| 464 | 3ph, 4W KWh CT Operated Base mounting 240 V-/5A acc. Cl 0.5s |
| 465 | 3ph, 4W KWh Direct Base mounting 240 V 10-60 Amp acc. Cl 1 |
| 466 | 3ph, 4W Trivector Meter,240 V(L-N) 5A acc. Cl 0.5 |
| 467 | P & F of Direct on line (DOL) / Star - Delta Starter as per IEC type-2 Co-ordination chart of OEM in Existing Panel with circuit breaker having inbuilt overload protection or separate thermal Overload relay , Short circuit, phase loss protection, suitable Contactors, including wiring between switchgears, Indicating lamps for R,Y,B,ON,OFF, Push button for ON, OFF, Volt meter, Ammeter, selector switch for local/remote, auto/manual/OFF operation. Cast resin CT's, provision for potential free contacts making connection, testing etc. as required. |
| 468 | Direct on line (DOL) Starter with following Motor rating |
| 469 | Motor rating 0.55 KW |
| 470 | Motor rating 0.75 KW |
| 471 | Motor rating 1.5 KW |
| 472 | Motor rating 2.2 KW |
| 473 | Motor rating 4.0 KW |
| 474 | Motor rating 5.5 KW |
| 475 | Motor rating 7.5 KW |
| 476 | Star - Delta Starter with following Motor rating |
| 477 | Motor rating 4.0 KW |
| 478 | Motor rating 5.5 KW |
| 479 | Motor rating 7.5 KW |
| 480 | Motor rating 9.0 KW |
| 481 | SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation from 50 to 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle ( to be paid extra) , including making connections etc. as required. OEM shall have submit NABL / CPRI / ERDA/ Intertek accrediated lab type test certificate. |
| 482 | 3 pole MCCB With Thermal Magnetic release |
| 483 | up to 100 Amp , 10 kA, fixed O/L & fixed S/C setting |
| 484 | up to 100 Amp , 25 kA, adjustable O/L & Fixed S/C setting, |
| 485 | 125 Amp , 25 kA, adjustable O/L & fixed S/C setting, |
| 486 | 160 Amp , 25 kA, adjustable O/L & fixed S/C setting, |
| 487 | 200 Amp , 25 kA, adjustable O/L & fixed S/C setting, |
| 488 | 250 Amp , 25 kA, adjustable O/L & adjustable S/C setting, |
| 489 | 250 Amp , 35 kA, adjustable O/L & adjustable S/C setting, |
| 490 | 400 Amp , 35 kA, adjustable O/L & adjustable S/C setting, |
| 491 | Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Aluminium cable confirming to IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing commissioning etc. as required of following size. |
| 492 | 4.0 Sq. mm |
| 493 | 2 core |
| 494 | 3 core |
| 495 | 4 core |
| 496 | 6.0 Sq. mm |
| 497 | 2 core |
| 498 | 3 core |
| 499 | 4 core |
| 500 | 10.0 Sq. mm |
| 501 | 2 core |
| 502 | 3 core |
| 503 | 4 core |
| 504 | 16.0 Sq. mm |
| 505 | 2 core |
| 506 | 3 core |
| 507 | 4 core |
| 508 | 25.0 Sq. mm |
| 509 | 2 core |
| 510 | 3 core |
| 511 | 3.5 core |
| 512 | 35.0 Sq. mm |
| 513 | 2 core |
| 514 | 3 core |
| 515 | 3.5 core |
| 516 | 50.0 Sq. mm |
| 517 | 2 core |
| 518 | 3 core |
| 519 | 3.5 core |
| 520 | 70.0 Sq. mm |
| 521 | 1 core |
| 522 | 2 core |
| 523 | 3 core |
| 524 | 3.5 core |
| 525 | 95.0 Sq. mm |
| 526 | 1 core |
| 527 | 3.5 core |
| 528 | Excavation of trench of size 75 cm (Depth) x 35 cm(Width) for laying of suitable no. of LT cables (Inter spacing between cables should not be less than 2 D) in ground with following procedure :- (a) Make a river sand bed of height 100 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 100 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable, (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth. |
| 529 | Add Extra in Item no.11.5 if Excavation done in Hard Rock / CC road / TAR Road and making Good the same |
| 530 | Excavation of trench of size additional 20 cm in width, with procedure as per following points :- (a) Make a river sand bed of height 100 mm along the trench, (b) Lay another cable in middle of trench in such manner that spacing between another cable is 20 cm., (c) Provide river sand bed of height 100 mm on top of the cable. (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 /Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically (Longest side is vertical to cable) along the cable , (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth |
| 531 | Add Extra in Item no. 11.7 if Excavation done in Hard Rock / CC road / TAR Road and making Good the same |
| 532 | Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 533 | Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. |
| 534 | Above 35 sq. mm and upto 95 sq. mm fixed with 40 mm x 3 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. |
| 535 | Above 95 sq. mm and upto 185 sq. mm fixed with 40 mm x 4 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. |
| 536 | Above 185 sq. mm and upto 400 sq. mm fixed with 50 mm x 5 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. |
| 537 | Add extra in item no. 11.1 to 11.4 for Laying Charges for cable through Manual Boggi by making pit at regular interval and repairing the pit after laying of cable with PCC/ Bitumin as required. |
| 538 | Add Extra in item no. 11.1 to 11.4 for Laying Charges for cable through Vermeer machine by making pit at regular interval and repairing the pit after laying of cable with PCC/ Bitumin as required. |
| 539 | Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring, Compression Nut, heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as per IS 8337-1976 of following size of PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required. |
| 540 | 2 x 4.0 sq.mm |
| 541 | 2 x 6.0 sq.mm |
| 542 | 2 x 10.0 sq.mm |
| 543 | 2 x 16.0 sq.mm |
| 544 | 2 x 25.0 sq.mm |
| 545 | 2 x 35.0 sq.mm |
| 546 | 2 x 50.0 sq.mm |
| 547 | 2 x 70.0 sq.mm |
| 548 | 3 x 4.0 sq.mm |
| 549 | 3 x 6.0 sq.mm |
| 550 | 3 x 10.0 sq.mm |
| 551 | 3 x 16.0 sq.mm |
| 552 | 3 x 25.0 sq.mm |
| 553 | 3 x 35.0 sq.mm |
| 554 | 3 x 50.0 sq.mm |
| 555 | 3 x 70.0 sq.mm |
| 556 | 3.5 x 25.0 sq.mm |
| 557 | 3.5 x 35.0 sq.mm |
| 558 | 3.5 x 50.0 sq.mm |
| 559 | 3.5 x 70.0 sq.mm |
| 560 | 3.5 x 95.0 sq.mm |
| 561 | 3.5 x 120.0 sq.mm |
| 562 | 3.5 x 150.0 sq.mm |
| 563 | 3.5 x 185.0 sq.mm |
| 564 | 3.5 x 240.0 sq.mm |
| 565 | 3.5 x 300.0 sq.mm |
| 566 | 3.5 x 400.0 sq.mm |
| 567 | Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring, Compression Nut, heavy duty Copper lugs (IS 8337- 1976) duly crimped with crimping tool, PVC tape for following size of PVC insulated & PVC sheathed/ XLPE copper conductor cable of 1100 volt grade as required. |
| 568 | 1 x 16.0 sq.mm |
| 569 | 1 x 25.0 sq.mm |
| 570 | 1 x 35.0 sq.mm |
| 571 | 1 x 50.0 sq.mm |
| 572 | 1 x 70.0 sq.mm |
| 573 | 1 x 95.0 sq.mm |
| 574 | 1 x 120.0 sq.mm |
| 575 | 2 x 4.0 sq.mm |
| 576 | 2 x 6.0 sq.mm |
| 577 | 2 x 10.0 sq.mm |
| 578 | 2 x 16.0 sq.mm |
| 579 | 2 x 25.0 sq.mm |
| 580 | 2 x 35.0 sq.mm |
| 581 | 2 x 50.0 sq.mm |
| 582 | 2 x 70.0 sq.mm |
| 583 | 2 x 95.0 sq.mm |
| 584 | 2 x 120.0 sq.mm |
| 585 | 3 x 1.5 sq.mm |
| 586 | 3 x 2.5 sq.mm |
| 587 | 3 x 4.0 sq.mm |
| 588 | 3 x 6.0 sq.mm |
| 589 | 3 x 10.0 sq.mm |
| 590 | 3 x 16.0 sq.mm |
| 591 | 3 x 25.0 sq.mm |
| 592 | 3 x 35.0 sq.mm |
| 593 | 3 x 50.0 sq.mm |
| 594 | 3 x 70.0 sq.mm |
| 595 | 3 x 95.0 sq.mm |
| 596 | 3 x 120.0 sq.mm |
| 597 | 4 x 1.5 sq.mm |
| 598 | 4 x 2.5 sq.mm |
| 599 | 4 x 4.0 sq.mm |
| 600 | 4 x 6.0 sq.mm |
| 601 | 4 x 10.0 sq.mm |
| 602 | 4 x 16.0 sq.mm |
| 603 | 4 x 25.0 sq.mm |
| 604 | 4 x 35.0 sq.mm |
| 605 | 4 x 50.0 sq.mm |
| 606 | 4 x 70.0 sq.mm |
| 607 | 4 x 95.0 sq.mm |
| 608 | 4 x 120.0 sq.mm |
| 609 | 6 x 1.5 sq.mm |
| 610 | 6 x 2.5 sq.mm |
| 611 | 8 x 1.5 sq.mm |
| 612 | 8 x 2.5 sq.mm |
| 613 | 10 x 1.5 sq.mm |
| 614 | 10 x 2.5 sq.mm |
| 615 | 12 x 1.5 sq.mm |
| 616 | 12 x 2.5 sq.mm |
| 617 | Supplying and making end termination with heavy aluminium lugs ( Pin / ring type ) confirming to IS 8309 -1993 duly crimped with crimping tool, PVC tape etc of following size. |
| 618 | 1.5 Sq.mm |
| 619 | 2.5 Sq.mm |
| 620 | 4.0 Sq.mm |
| 621 | 6.0 Sq.mm |
| 622 | 10.0 Sq.mm |
| 623 | 16.0 Sq.mm |
| 624 | 25.0 Sq.mm |
| 625 | 35.0 Sq.mm |
| 626 | 50.0 Sq.mm |
| 627 | 70.0 Sq.mm |
| 628 | 95.0 Sq.mm |
| 629 | 120.0 Sq.mm |
| 630 | 150.0 Sq.mm |
| 631 | 185.0 Sq.mm |
| 632 | 240.0 Sq.mm |
| 633 | 300.0 Sq.mm |
| 634 | 400.0 Sq.mm |
| 635 | 500.0 Sq.mm |
| 636 | 630.0 Sq.mm |
| 637 | 800.0 Sq.mm |
| 638 | 1000.0 Sq.mm |
| 639 | Supplying and making end termination with heavy duty Copper lugs ( ANY type ) confirming to IS 8309 -1993 duly crimped with crimping tool, PVC tape etc of following size. |
| 640 | 1.5 Sq.mm |
| 641 | 2.5 Sq.mm |
| 642 | 4.0 Sq.mm |
| 643 | 6.0 Sq.mm |
| 644 | 10.0 Sq.mm |
| 645 | 16.0 Sq.mm |
| 646 | 25.0 Sq.mm |
| 647 | 35.0 Sq.mm |
| 648 | 50.0 Sq.mm |
| 649 | 70.0 Sq.mm |
| 650 | 95.0 Sq.mm |
| 651 | 120.0 Sq.mm |
| 652 | Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required. |
| 653 | 100mm x 50mm x 1.6mm |
| 654 | 150mm x 50mm x 1.6mm |
| 655 | 225mm x 50mm x 1.6mm |
| 656 | 300mm x 50mm x 1.6mm |
| 657 | Supply, Fabricating & installing following sizes of perforated Powder coated MS cable tray with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required. |
| 658 | 100mm x 50mm x 1.6mm |
| 659 | 150mm x 50mm x 1.6mm |
| 660 | 225mm x 50mm x 1.6mm |
| 661 | 300mm x 50mm x 1.6mm |
| 662 | 375mm x 50mm x 2.0mm |
| 663 | S & Making Heat shrinkable type Tubular sleeve version outdoor straight through joint for following size of PVC/ XLPE insulated aluminium conductor cable of 1.1 KV grade as required. |
| 664 | 1 x 25 sq.mm-50 sq.mm |
| 665 | 1 x 70 sq.mm-150 sq.mm |
| 666 | 1 x 185 sq.mm-300 sq.mm |
| 667 | 1 x 400 sq.mm |
| 668 | 1 x 500 sq.mm |
| 669 | 1 x 630 sq.mm |
| 670 | 1 x 800 sq.mm |
| 671 | 1 x 1000 sq.mm |
| 672 | 2 x 1.5 sq.mm-6 sq.mm |
| 673 | 2 x 10.0-16.0 sq.mm |
| 674 | 2 x 25.0 sq.mm-50 sq.mm |
| 675 | 2 x 70.0 sq.mm-150 sq.mm |
| 676 | 2 x 185.0 sq.mm-300 sq.mm |
| 677 | 2 x 400 sq.mm |
| 678 | 2 x500 sq.mm |
| 679 | 3/3.5/4 x 1.5 sq.mm-6 sq.mm |
| 680 | 3/3.5/4 x 10.0-16.0 sq.mm |
| 681 | 3/3.5/4 x 25.0 sq.mm-50 sq.mm |
| 682 | 3/3.5/4 x 70.0 sq.mm-150 sq.mm |
| 683 | 3/3.5/4 x 185.0 sq.mm-300 sq.mm |
| 684 | 3/3.5/4 x 400 sq.mm |
| 685 | 3/3.5/4 x500 sq.mm |
| 686 | S/F cable route marker with 10cm x 10cm x 5mm thick or 10 cm dia. G.I.plate with inscription thereon, bolted/welded to 35mm x 35mm x 5mm angle iron, 60cm long and fixing the same in ground in C C ( 1:3:6 ) as required |
| 687 | P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of trench, CC Haunching, Back filling of Earth with compaction is to be Paid Extra). |
| 688 | 50 mm |
| 689 | 63 mm |
| 690 | 75 mm |
| 691 | 90 mm |
| 692 | 110 mm |
| 693 | 120 mm |
| 694 | 160 mm |
| 695 | 200 mm |
| 696 | Providing & Laying XLPE insulated three core Armoured Aluminium cable for working voltage 11 K.V.(E) confirming IS :7098 P - 2 with H4- Grade electrolytic aluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831 in existing RCC pipe / Hume Pipe/ Stoneware Pipe/ PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. |
| 697 | 3 core 95.0 Sq.mm |
| 698 | 3 core 120.0 Sq.mm |
| 699 | 3 core 150.0 Sq.mm |
| 700 | 3 core 185.0 Sq.mm |
| 701 | 3 core 240.0 Sq.mm |
| 702 | 3 core 300.0 Sq.mm |
| 703 | Providing & Laying XLPE insulated three core Armoured Aluminium cable for working voltage 33 K.V.(E) confirming IS :7098 P - 2 with H4- Grade electrolytic aluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. |
| 704 | 3 core 150.0 Sq.mm |
| 705 | 3 core 185.0 Sq.mm |
| 706 | 3 core 240.0 Sq.mm |
| 707 | 3 core 300.0 Sq.mm |
| 708 | Excavation of trench of size 120 cm (Depth) x 35 cm(Width) for Laying of suitable no. of HT cable( Inter spacing between cables should not be less than 2 D) in ground with following procedure:- (a) Make a river sand bed of height 125 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 125 mm on top of the cable. (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth |
| 709 | Add Extra in Item no. 13.3 if Excavation done in Hard Rock / CC road / TAR Road and making Good the same |
| 710 | Add Extra for Laying of one number additional XLPE power cable of 11/33 KV (Earthed) voltage grade direct in ground in the same trench in one tier horizontal formation including excavation of trench of size additional 20 cm in width, with procedure as per following points:- (a) Make a river sand bed of height 125 mm along the trench, (b) Lay another cable in middle of trench in such manner that spacing between another cable is 20 cm, (c) Provide sand bed of height 125 mm on top of the cable. (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.) (e) Backfill the excavated soil leaving 300 mm from the Ground level. (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth |
| 711 | Add Extra in Item no. 13.5 if Excavation done in Hard Rock / CC road / TAR Road and making Good the same |
| 712 | Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit suitable for 11 KV / 33 KV (Earthed) cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 including testing etc. as required of following sizes. |
| 713 | 11 KV End Termination Kit Indoor type |
| 714 | 3 core up to 35 Sqmm |
| 715 | 3 core 50/70/95 Sq.mm |
| 716 | 3 core 120/150/185 Sq.mm |
| 717 | 3 core 240/300 Sq.mm |
| 718 | 3 core 400 Sq.mm |
| 719 | 11 KV End Termination Kit Outdoor type |
| 720 | 3 core up to 35 Sqmm |
| 721 | 3 core 50/70/95 Sq.mm |
| 722 | 3 core 120/150/185 Sq.mm |
| 723 | 3 core 240/300 Sq.mm |
| 724 | 3 core 400 Sq.mm |
| 725 | 11 KV Straight Through Joint Kit |
| 726 | 3 core up to 35 Sq.mm |
| 727 | 3 core 50/70/95 Sq.mm |
| 728 | 3 core 120/150/185 Sq.mm |
| 729 | 3 core 240/300 Sq.mm |
| 730 | 3 core 400 Sq.mm |
| 731 | Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. ' B ' class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required. |
| 732 | Plate Earthing as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required. |
| 733 | Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required. |
| 734 | SITC of Copper Bonded rod Earthing with high tensile strength (more than 600 N / sq.mm low carbon steel rod molecularly bonded with Copper thickness (250 microns) and confirming to UL 467 of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- |
| 735 | (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole |
| 736 | (b)Earth enhancing compound to ensure the moisture content and electrical conductivity, 25 kg for 3000 mm. The compound shall be tested form NABL accredited lab for low resistivity (less than 0.12 Ohm - meter) & high conductivity in nature with carbon as a major content in accordance with IEC 62561-7 |
| 737 | © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt |
| 738 | (d) Place Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm. |
| 739 | (e) Testing of earth resistance for value of 5 ohms or less as required. |
| 740 | (f) Test certificates for confirming above standards from OEM is mandatory. |
| 741 | 17.2 mm thick and 3 Mtr. Long |
| 742 | 25 mm thick and 3 Mtr. Long |
| 743 | Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping double the width of strip and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. |
| 744 | 20mm x 3mm copper strip |
| 745 | 25mm x 3mm copper strip |
| 746 | 20mm x 3mm G.I. ( Hot Dipped ) Strip |
| 747 | 25mm x 3mm G.I. ( Hot Dipped ) Strip |
| 748 | Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required. |
| 749 | 6 SWG tinned copper Wire |
| 750 | 8 SWG tinned copper Wire |
| 751 | 10 SWG tinned copper. Wire |
| 752 | 6 SWG copper Wire |
| 753 | 8 SWG copper Wire |
| 754 | Supply & Laying following size' B ' class , G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc. for laying earth conductor/ strip / cable in ground/ surface/ recess as required. (Earth Excavation will be Paid Extra) |
| 755 | 15 mm dia. |
| 756 | 20 mm dia. |
| 757 | 25 mm dia. |
| 758 | 32mm dia |
| 759 | Making of hole in wall (brick/stone) of required and placing NP-2 RCC pipe ring of required size for housing exhaust fan and making good the same, with cement plaster required of following size. |
| 760 | Up to 457 mm size |
| 761 | more than 457 mm & up to 610 mm |
| 762 | Supply & Fixing of phenolic laminated board of 6.0 mm thick for fresh air fan/exhaust fan up to size of 300 mm on existing window frame including cost of board, cutting of hole , Nut bolts etc. as required. |
| 763 | Providing & Fixing of BEE Star rated copper wounded with class of Insulation 'F', double ball bearing capacitor start, aluminium body & aluminium blade ceiling fan conforming to all the performance requirements laid down in IS 374:2019 with down rod up to 30 cm with secondary support safety cable ( steel rope) , cotter pin, shackle kit with 3 x 1.5 sq.mm pvc insulated flexible copper conductor and making connection testing etc. as required. |
| 764 | 1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) |
| 765 | Providing & Fixing of shackle (iron hook) made from 2mm nominal thick CRCA sheet and bolts (2nos) of 6mm with spring washer nut, checknut & split pin as required. |
| 766 | Providing & Fixing of of M.S. J- hook of standard design made out of 16 mm dia. M.S. round bar and fixed with cement concrete mortar with required support as required. |
| 767 | P & F 1.2 mm thick M.S. Recessed fan box and top lid screwed on Box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 150 mm length extended on each side as required. |
| 768 | Providing & Fixing of of Double ball bearing, copper wounded capacitor start single phase metallic blade fresh air fan, in existing opening including cost of hardware , flexible 3 core 1.5 Sq.mm copper conductor ,making connections, testing etc. as required. |
| 769 | 230 mm sweep, Minimum air delivery 750 Cum / hour |
| 770 | 300 mm sweep Minimum air delivery 1600 Cum / hour |
| 771 | Providing & Fixing of Heavy duty capacitor start, copper wound Double ball bearing 900/1400 RPM single phase Exhaust fan conforming to IS:2312 marked in existing opening including making connections testing etc. as required. |
| 772 | 300 mm sweep(900 RPM) |
| 773 | 380 mm sweep(900 RPM) |
| 774 | 450 mm sweep(1400 RPM) |
| 775 | 600 mm sweep(900 RPM) |
| 776 | Providing & Fixing of ventilating fans Capacitor start, copper wounded, single phase with PVC impeller, ABS body, automatic openable louver shutter in existing opening including making connection, testing etc. as required. |
| 777 | 150 mm sweep Minimum Air Delivery 150 Cum / hour |
| 778 | 200 mm sweep Minimum Air Delivery 450 Cum / hour |
| 779 | 250 mm sweep Minimum Air Delivery 750 Cum / hour |
| 780 | Providing & Fixing of Wall mounting / Pedestal type Heavy duty Air Circulator , Double ball bearing and with metal sturdy mesh guard; Aluminium alloy one piece blade and conforming to IS:2997, including fixing with anchor bolts, making connection testing etc. as required. |
| 781 | 450 mm sweep Wall mounting and three speed regulator with Minimum Air Delivery 150 Cum. / Minute |
| 782 | 450 mm sweep Pedestal type and three speed regulator with Minimum Air Delivery 150 Cum. / Minute |
| 783 | 600 mm sweep Wall mounting with Minimum Air Delivery 270 Cum. / Minute |
| 784 | 600 mm sweep Pedestal type with Minimum Air Delivery 270 Cum. / Minute |
| 785 | Providing & Fixing of 450 mm Sweep Oscillating type Wall mounting / Pedestal type fans with Three speed, ON and OFF position, Sintered Iron bush oil impregnated, with metal front and back 120 or more ribs guard; Three no. Aluminium blades, minimum Air delivery 100 Cum. / Minute , Minimum Service Value 1.11 Cum./min/watt, noise level should be <= 75 dB, power consumption <= 120 watts, motor protection through thermal overload protection device, including fixing with anchor bolts, making connection testing etc. as required. |
| 786 | Wall mounting type with Adjustable Vertical Angle |
| 787 | Pedestal Type with Adjustable Height |
| 788 | Providing & Fixing of extra down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steel pipe including cutting, threading, drilling, fixing quarter pin etc as required. |
| 789 | Numbering of ceiling fans/ fixtures with approved enamel paint etc as required. |
| 790 | P & F of Gravity Louver shutter of superior quality made out of frame of 18 swg M.S. sheet & Louvers made from 24 swg MS Sheet with enamel paint including cost of nuts, bolts, etc as required. |
| 791 | Up to 380 mm size |
| 792 | above 380 mm size |
| 793 | P & F of Wall cowl with Bird Screen Suitable for Outside Wall of Exhaust Fan Opening of following size and made out from 24 SWG GI sheet as per instructions of Engineer in charge including fixing with suitable fasteners etc. as required. |
| 794 | Suitable for 300 mm sweep Exhaust Fan |
| 795 | Suitable for 380 mm sweep Exhaust Fan |
| 796 | Suitable for 450 mm sweep Exhaust Fan |
| 797 | S & F Extruded Aluminium Fresh Air / External Weather Louver, Small Format type with 38 mm flange width & 50 mm depth. finish - powder coated off white with aluminium mesh of required size. |
| 798 | Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap action adjustable thermostat , Dual indicating lamps Injected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top , including making inlet, outlet Flexible alloy connection, testing etc. as required. |
| 799 | 6 Ltr. |
| 800 | 10 Ltr. |
| 801 | 15 Ltr. |
| 802 | 25 Ltr. |
| 803 | 35 Ltr. |
| 804 | 50 Ltr. |
| 805 | Providing & Fixing of stem type ISI marked (IS 3017 / 85) snap action adjustable thermostat for storage water heater including making connection testing etc. complete in all respect. |
| 806 | Providing & Fixing of stem type ISI marked (IS 3017 / 85) , snap action bipolar adjustable thermostat with built in auto thermal cut out for storage water heater including making connection testing etc. complete in all respect. |
| 807 | Providing & Fixing 2 / 3 KW nickle plated, mineral filled heating element including making connection testing etc complete in all respect. |
| 808 | Providing & Fixing of 2 / 3 KW Glass Line Coated , mineral filled heating element including making connection testing etc complete in all respect. |
| 809 | Providing & Fixing of Multi safety valve of 8.5 bar capacity with built in drain, NRV, Vacuum release, Pressure release etc. as required complete in all respect. |
| 810 | Providing & Fixing of Twin neon indicating lamp of superior quality for storage water heater complete in all respect. |
| 811 | Providing & Fixing of 13 mm Brass with C.P. finished ISI marked angle valve for storage water heater as required complete in all respect. |
| 812 | Providing & Fixing of heavy duty flexible alloy pipe for storage water heater for inlet and outlet of suitable length including the cost of nuts, washers etc complete in all respect. |
| 813 | 450 mm |
| 814 | 600 mm |
| 815 | Charges for descaling of storage water heater including replacement of Multi Function Valve as required. |
| 816 | Charges for Fixing of storage water heater including 10/12 mm Anchor fasteners of suitable size, testing, carrying from store to site,etc. as required. |
| 817 | Providing & Fixing of 2.0 KW twin ceremic cartridge, Withstands temperatures up to 1000 C long lasting even in hard water including making connection testing etc complete in all respect. |
| 818 | Supplying, Installation, Testing, Commissioning of following capacity Evacuated Tube Collector (ETC) Solar Water Heating System comprising of all glass ETC tube absorber. The inner layer of absorber shall be of solar selected absorbing coated tube, Vacuum jacket, cover glass tube, getter and getter mirror surface, as per IS 16543. The system shallhave temperature gauges, strainer, 2 nos. water meters, Suitable capacity cold and hot water tank, all MS structure for installation including suitable electric control panel complete with control and power wiring, necessary pluming including piping for cold and hot water line between tank and solar water system, water heater and thermostat including non-return valve, float valve and other valve etc. as required. The various component shall have specification as A, B, C, D, E & F |
| 819 | A)The Absorber area i.e. the number, dimension and thickness of solar evacuated tube as per IS:16544 clause 5.4 and IS: 16543 clause 4.2 |
| 820 | B) Boro Silicate Glass 3.3 for cover plat as per ISO: 3585. |
| 821 | C) The material for three target coating shall be aluminum nitrate, aluminum nitrate stainless steel and copper multi layer selecting coating as per IS: 16543. |
| 822 | D) Manifold shall be of Mild steel section with PP coating and Inner material shall be of SS 304. |
| 823 | E) Recommended operating pressure:10 Bars. 6. The capacity of hot water tank shall be minimum 1.5 times the rated capacity system. Inner Material shall be Stainless Steel SS 316 b) as per IS 1730 grade SS304-2B (22SWG). The hot water tank shall be insulated with high density injected PUF insulation 50 mm thickness between inner and outer tank. Tank stand shall be of mild steel and shall be design to withstand wind velocity of 100km/hours (minimum) or more as per site. |
| 824 | F) Suitable nos. ISI Marked electrical heaters along control panel, with suitable breaker, all protections, and all safety provisions so as to achieve 60 0C temperature rise in an hour. The range of thermostat shall be upto 80 0C |
| 825 | 100 litre/ day |
| 826 | 200 litre/ day |
| 827 | 300 litre/ day |
| 828 | 500 litre/ day |
| 829 | Supply, Installation, Testing & Commissioning of Flat Plate collector (FPC) Solar Water Heating System comprising of solar flat plate collector ISI Marked made of copper sheet/copper tube, absorber toughened glass cover and aluminium extruded channel confirm to IS: 12933 (Part 1,2,3&5). The system shall have temperature gauges, strainer, water meter 2 nos., cold and hot water tank. The system shall have suitable electric backup complete with control and power wiring etc. with specification as per A, B, C, D & E |
| 830 | A) Cover plate: cover plate shall be toughened glass and thickness of 4.0 mm (min) conforming to section -1 of IS: 12933(pt-2)/2003 the solar transmittances of the cover plate shall be minimum 82 percent at near normal incidence. |
| 831 | B) Collector box: collector box shall be made of aluminium sections. The type grade, size, and finish of the material used shall be as per section-2 of IS: 12933 (pt-2)/2003: the minimum thickness of aluminium shall be as under: a. Channel section for sides 1.6 mm. b. Sheet for bottom 0.7 mmc. Support for glass retaining 1.2 mm d. Sheet for entire body 1.0 mm. The insulation of collector box shall be minimum 0.96 sq.m 0C/W for back insulation and minimum 0.48 m square degree c/w for side insulation conform to sec. 4 of IS 12933 (Part – 2) / 2003. (b) Gaskets and grommets: gaskets and grommets shall conform to Sec. 5 of IS 12933 (pt-2)/2003. |
| 832 | C) Absorber Shall Consist of riser, Header and Sheet for absorber. The Diameter of header shall be 25.4 + /-0.5mm and thickness 0.71mm. The Diameter of riser shall be 12.7 + /-0.5 mm and thickness 0.56mm and made of copper only. The distance between the risers from centre to centre shall be 120mm. type grade, size , workmanship and finish of the material used shall be as per section- 3 of IS : 12933 (pt -2 ) /2003 the sheet for absorber shall be of copper sheet 34 gauge/copper tube (at least 10 nos.) 4.Riser and header assembly designed for working pressure up 245 k pa (2.5 kg/ cm square) shall be tested for leakage at a minimum hydraulic pressure of 490 k pa (5 kg/ cm square). Sheet for absorber shall be made of copper only. Type Grade, size, workmanship and finis of the material used shall be per Section -3 of IS: 12933 (pt -2) /2003. 5.HDPE/LDPE cold water tank and hot water tank shall be dully erected on MS angle /channel duly painted with dual coats of enamel paint. The overall structure of solar collector plate module shall be design to with stand wind velocity of 100 kms /hr (minimum) or more as per site. |
| 833 | D) Hot water tank : The tank capacity shall be minimum 1.25 time the rated capacity of system. Inner tank material shall be stainless steel SS 316, as per IS 1730 GRADE SS304-2B. Hot water shall be insulated with high density injected PUF insulation: 50 mm, of 50 mm thickness between inner and outer tank ensures maximum heat rotenone ever season. |
| 834 | E) Suitable nos. ISI Marked electrical heaters along control panel, suitable breaker all protections, and all safety provisions so as to achieve 600C temperature rise in an hour. The range of thermostat shall be upto 800C. |
| 835 | 100 litre/ day |
| 836 | 200 litre/ day |
| 837 | 300 litre/ day |
| 838 | 500 litre/ day |
| 839 | Supplying, installation , testing & commissioning of Heat pumps system for hot water using heat energy source from ambient air to Hot water, of High efficiency and energy saving operation, capable of heating water at 550 to 600 C with silent operation (the sound level should not exceed 65 dB). The Heat Pump shall have LCD display control panel with built in diagnostic and troubleshooting information and an inbuilt cycle for defrosting in case icing occurs on evaporator including all other mounting, fitting and controls, all interconnecting wiring/cabling between heat pump and electric panel etc including hot water storage tank complete in all respect with but not limited to following specifications. Power Supply V/Ph/Hz : 400V~440V, three Phase, 50Hz. Suggested Maximum output water temperature in 0C: >55 0C, ambient temperature range in 0C: -5 0C~45 0C , Type of Fan : Low Noise axial fan , Suggested Noise level: dB <65 , COP: 3.0 to 4.0. Hot Water Storage Tank consisting of GI/MS/SS cylindrical shape clarifier tank. (inlet temperature of hot water storage tank >550C) suitable for minimum 4 Kg /Sq.cm working pressure. Tank shall be provided with water flow meter, inlet / outlet, overflow, drain connection with cover, 6 mm thick tank, pressure relief valves, pressure gauge at inlet / outlet with isolation cock, thermometer at inlet / outlet, ball Valve, safety valve,check valve etc and capacity of the tank shall be for 03 Hr rated output.The complete system to be tested to a pressure of 10 Kg/cm2 complete in all respects including temperature indicators, thermostat and other required accessories.Tank shall be insulated with 100 mm thick crown 150 grade & 50 mm rock wool pads of approved quality and cladded with 24 SWG aluminium sheet cladding. |
| 840 | 200 Litre |
| 841 | 300 Litre |
| 842 | 500 Litre |
| 843 | SITC of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output only at CW (5700K to 6500K) , internal surge protection of 4.0 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 844 | 1170mm(+/-10%) LED batten with min. lumen output 2200 lm |
| 845 | 570mm (+/-10%) batten with min. lumen output 1000 lm |
| 846 | SITC of IP-20 LED Recessed / Surface Mounted, Round / Square backlit & SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS compliance 4.0 KV surge protected Isolated driver, with Short & Open circuit protection input 320VAC-48 hr protection, input 350VAC-2 hr protection), having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt,at CW (5700K to 6500K) , THD < 10 % , Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 847 | Recessed Mounting |
| 848 | Minimum lumen output 600 lm (lumen efficacy ≥ 100 lm / watt) |
| 849 | Minimum lumen output 1300 lm |
| 850 | Minimum lumen output 1600 lm |
| 851 | Minimum lumen output 1950 lm |
| 852 | Minimum lumen output 2400 lm |
| 853 | Surface Mounting (with extruded alumn. Housing ) |
| 854 | Minimum lumen output 600 lm (lumen efficacy ≥ 100 lm / watt) |
| 855 | Minimum lumen output 1300 lm |
| 856 | Minimum lumen output 1600 lm |
| 857 | Minimum lumen output 1950 lm |
| 858 | Minimum lumen output 2400 lm |
| 859 | SITC of IP20, 2'x2' LED Surface/ Recessed mounting backlit & SMD Mid power type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmissivity UV stabilized Non -yellowish diffuser for uniform light distribution. operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V . High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection ( input 320VAC-48 hoursprotection,input 350VAC-2 hours protection) (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 860 | Recessed Mounting |
| 861 | Minimum lumen output 4320 lm |
| 862 | Minimum lumen output 4800 lm |
| 863 | Surface Mounting (Driver should be Inside the Luminaire) |
| 864 | Minimum lumen output 4320 lm |
| 865 | Minimum lumen output 4800 lm |
| 866 | SITC of IP20, 1'X1' LED Surface/ Recessed mounting backlit & SMD Mid power type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution.operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 867 | Recessed Mounting |
| 868 | Minimum lumen output 2880 lm |
| 869 | Minimum lumen output 3600 lm |
| 870 | Surface Mounting (Driver should be Inside the Luminaire) |
| 871 | Minimum lumen output 2880 lm |
| 872 | Minimum lumen output 3600 lm |
| 873 | SITC of IP65 IK08 rated Integrated High power LED ( each LED between 3 to 5 watt power with secondary lencs on each LED) Highbay light fixture made from Pressure Die Cast Aluminium housing, UV stabilized PC Cover/ Toughened glass diffuser, potted driver, Eye bolt for mounting, system lumen efficacy ≥150 lm/Watt output , THD < 10% ,p.f.≥0.95,CRI >70 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and . surge protection 4 KV inbuilt & 10 KV external inside fixture as required. |
| 874 | Minimum lumen output 12000 lm |
| 875 | Minimum lumen output 15000 lm |
| 876 | Minimum lumen output 18000 lm |
| 877 | Minimum lumen output 22500 lm |
| 878 | SITC of Suspended mounting IP66 IK08 rated Integrated High power LED Wellglass light fixture made from Pressure Die Cast Aluminium housing, potted driver, Eye bolt for mounting, PC clear / Opal Diffuser, system lumen efficacy ≥130 lm/Watt output only at CW (5700K to 6500K) , THD < 10% ,p.f.≥0.95,CRI >70 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating surge protection 4 KV inbuilt & 10 KV external inside fixture as required. |
| 879 | Minimum lumen output 4550 lm |
| 880 | Minimum lumen output 9100 lm |
| 881 | SITC of energy efficient /energy saving IP 20 LED direct retrofit Bulb in existing holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf 0.95 , CRI >70, minimum life time of minimum 25000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 882 | 9 Watt |
| 883 | 15 Watt |
| 884 | 18/20 Watt |
| 885 | SITC of IP 20 box made out from 1.0 mm thick CRCA sheet steel with depth of minimun 30 mm and finished with powder coating and suitable for mounting LED tube including side covers, holders , internal wiring to illuminate the single sided connection LED tube. ( Without tube). |
| 886 | Suitable for 2' LED Tube shape fixture for single rod |
| 887 | Suitable for 4' LED Tube shape fixture for single rod |
| 888 | Suitable for 4' LED Tube shape fixture for double rod |
| 889 | Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap ( 250x 88.9 / 114.3 x 3.25 mm) over the existing poles. |
| 890 | Single arm overhang |
| 891 | Double arm overhang |
| 892 | Charges for oiling, overhauling of ceiling fan, table fan, pedestal fan irrespect to the size of fan including removing,refixing of fan from site and testing etc. as required. |
| 893 | Fans w/o Removing & Refixing |
| 894 | Fans with Removing & Refixing at Suitable Location |
| 895 | Providing and Replacement of ball bearing of ceiling/ exhaust fan and refixing the same at suitable location as requiredand as per OEM recommendations. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material shall be retained by the contractor. |
| 896 | Replacement of existing transformer oil confirming to IS: 335 after removing of old oil and remove from site (old oil shall be retained by the contractor) |
| 897 | Charges for Collection , Filtration and dehydration of existing transformer oil with the help of high vaccum filtration machine and cleaning of core-coil assembly by hot oil for removal of sludge / dust particles etc. as required. |
| 898 | Add for supply and fixing of Pole OEM fabricated Galvanized Overhang of following size over the existing poles. |
| 899 | 76.1 mm OD x 3.25 mm thickness |
| 900 | 88.9 mm OD x 3.25 mm thickness |
| 901 | 114.3 mm OD x 3.65 mm thickness |
| 902 | Add for supply and fixing of Pole OEM fabricated Mild steel Overhang of following size over the existing poles, Overhang shall be painted with two coat of red oxide primer and two coat of enamel paint of silver colour as required. |
| 903 | 76.1 mm OD x 3.25 mm thickness |
| 904 | 88.9 mm OD x 3.25 mm thickness |
| 905 | 114.3 mm OD x 3.65 mm thickness |
| 906 | Rewinding of Heavy duty Exhaust fan motor including all necessary material,The motor is to be wound taking no. of coils,turns and pitch as it was originally wound with required size super enamelled wire with 'E' class insulation material and making connections etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 907 | 300/ 380 mm sweep |
| 908 | 450 mm sweep |
| 909 | Providing & Fixing of IK07 IP65 protected Top/Bottom mounted LED Post top Luminarie top & bottom made of single piece construction powder coated die cast alluminium housing with UV stabalized Clear / frosted Polycarbonate diffuser and Aluminium anodised with powder quoted reflector. The System level Luminous efficacy ≥ 80 Lumen/W. SMD LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency > 85%, PF>0.9, THD<10% and input Voltage range of 140-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained . LED Driving output current <750mA as required. |
| 910 | Minimum lumen output 2800 lm Post top Luminarie |
| 911 | Minimum lumen output 3200 lm Post top Luminarie |
| 912 | Minimum lumen output 3600 lm Post top Luminarie |
| 913 | Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass with suitable lenses on LED / integrated lens diffuser to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated metal case potted driver as a unique BIS R number (as per IS 15885) having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate(Fitting & driver both have separate BIS R number). The System level Luminaire efficacy >=130 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC & Low Voltage cutoff @>=90 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , LED driving output current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K as required. |
| 914 | High Power LED Flood Light Minimum lumen outpu 3900 lm |
| 915 | High Power LED Flood Light Minimum lumen output 6500 lm |
| 916 | High Power LED Flood Light Minimum lumen output 10400 lm |
| 917 | High Power LED Flood Light Minimum lumen output 13000 lm |
| 918 | High Power LED Flood Light Minimum lumen output 15600 lm |
| 919 | High Power LED Flood Light Minimum lumen output 19500 lm |
| 920 | High Power LED Flood Light Minimum lumen output 23400 lm |
| 921 | High Power LED Flood Light Minimum lumen output 26000lm |
| 922 | High Power LED Flood Light Minimum lumen output 32500 lm |
| 923 | High Power LED Flood Light Minimum lumen output 39000 lm |
| 924 | High Power LED Flood Light Minimum lumen output 45500 lm |
| 925 | High Power LED Flood Light Minimum lumen output 52000 lm |
| 926 | Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing and secondary lens on each LED/ integrated lens diffuser without cover & should be High power LED of 3 to 5 watt each . The System efficacy >=135 lm/ wt and integrated metal case potted driver & has a unique BIS R number ( as per IS 15885) with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC & Low Voltage cutoff @>=90 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . LED driving output current <750mA. The luminaire shall be BIS certified (Fitting & driver both have separte BIS R number) and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs as required. |
| 927 | LED Street Light fixture with Minimum lumen output 2700 lm |
| 928 | LED Street Light fixture with Minimum lumen output 4050 lm |
| 929 | LED Street Light fixture with Minimum lumen output 6075 lm |
| 930 | LED Street Light fixture with Minimum lumen output 8100 lm |
| 931 | LED Street Light fixture with Minimum lumen output 9450 lm |
| 932 | LED Street Light fixture with Minimum lumen output 12150 lm |
| 933 | LED Street Light fixture with Minimum lumen output 13500 lm |
| 934 | LED Street Light fixture with Minimum lumen output 16200 lm |
| 935 | LED Street Light fixture with Minimum lumen output 20250 lm |
| 936 | LED Street Light fixture with Minimum lumen output 24300 lm |
| 937 | LED Street Light fixture with Minimum lumen output 28350 lm |
| 938 | Providing & Fixing of IK08 IP65 protected 600-800 mm height LED Bollard Luminarie with base plate made of powder coated die cast aluminium housing with UV stabalized PC diffuser. The System level Luminous efficacy ≥ 80 Lumen/W. SMD LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency > 85%, PF>0.9, THD<20% and input Voltage range of 90-270V AC at 50Hz. System life of 30000 Burning hours with 70% of Initial Lumens maintained Light output in Cool white or Warm White Colour as per engineers choice. LED driving output current <750mA. as required. |
| 939 | Minimum lumen output 800 lm Bollard |
| 940 | Minimum lumen output 980 lm Bollard |
| 941 | Providing & Fixing of IK08 IP66 / IP67 protected Rectangular shape LED Step Luminarie made of powder coated die cast alluminium housing with UV stabalized PC diffuser. The System level Luminous efficacy ≥ 60 Lumen/W. SMD LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency > 85%, PF>0.9, THD<20% and input Voltage range of 140-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained . driver current <750mA as required. |
| 942 | Minimum lumen output 450 lm Step light |
| 943 | Minimum lumen output 630 lm Step light |
| 944 | Minimum lumen output 800 lm Step light |
| 945 | Providing & Fixing of IK08 IP65 / IP66 protected LED Up - Down Luminarie Wall / Surface mounting made of powder coated die cast alluminium housing with with UV stabalized PC diffuser. The System level Luminous efficacy ≥ 80 Lumen/W. COB LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency > 85%, PF>0.9, THD<10% and input Voltage range of 140-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained Light output in Cool white or Warm White Colour as per engineers choice. LED driving output current <750mA. as required. |
| 946 | Minimum lumen output 800 lm Up-Down Luminary |
| 947 | Minimum lumen output 1300 lm Up-Down Luminary |
| 948 | Minimum lumen output 2150 lm Up-Down Luminary |
| 949 | Providing & Fixing of Street light bracket made out from following size of ' B ' class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. |
| 950 | 20 mm Dia. |
| 951 | 25 mm Dia. |
| 952 | 32 mm Dia. |
| 953 | 40 mm Dia. |
| 954 | Providing & Fixing of IP - 65 protected impact resistant polycarbonate / Polysterene enclosures with knock out for cable entry/out including fixing with nut, bolt, fatner etc as required complete in all respect of following sizes. |
| 955 | 180 x 180 x 91 mm |
| 956 | 250 x 200 x 115 mm |
| 957 | 300 x 450 x 132 mm |
| 958 | 320 x 440 x 179 mm |
| 959 | 320 x 640 x 179 mm |
| 960 | Labour charges for installation of submersible motor pump set including lowering/ delowering of pipes, cables, accessories etc. in tube-well/ open well complete including T&P, transportation of tripod, chain pulley block & any other material required for this purpose complete in all respect. |
| 961 | Lowering only |
| 962 | Delowering only |
| 963 | Delowering and Lowering |
| 964 | Supply & fixing of PVC threaded casing pipes for Tube well (IS 12818:1992) as required |
| 965 | Up to 400 ft Depth |
| 966 | 150 mm dia |
| 967 | 175mm dia |
| 968 | 200 mm dia |
| 969 | 250 mm dia |
| 970 | more than 400 ft to 1200 ft. Depth |
| 971 | 40mm dia |
| 972 | 50 mm dia |
| 973 | 80mm dia |
| 974 | 100 mm dia |
| 975 | 125 mm dia |
| 976 | 150 mm dia |
| 977 | 175 mm dia |
| 978 | 200 mm dia |
| 979 | 250 mm dia |
| 980 | Providing & Laying of Polypropylene rope Confirming to IS:5175 for submersible pump of following sizes. complete in all respect. |
| 981 | 12mm (suitable up to 50 mm OD pipe) |
| 982 | 16mm (suitable above 50mm & up to 75 mm OD pipe) |
| 983 | 20mm (suitable for 90 mm OD pipe) |
| 984 | Providing & Fixing of HDPE pipe Confirming to IS:4984:2021 for water supply suitable for submersible & jet pump with required fittings ie socket, elbows, tee etc. complete in all respect. |
| 985 | for vertical installation |
| 986 | 40 mm OD 6 kg / cm2 |
| 987 | 50 mm OD 6 kg / cm2 |
| 988 | 63 mm OD 6 kg / cm2 |
| 989 | 75 mm OD 6 kg / cm2 |
| 990 | 90 mm OD 10 kg / cm2 |
| 991 | for Horizontal installation |
| 992 | 40 mm OD 4kg/ cm2 |
| 993 | 50 mm OD 4 kg/ cm2 |
| 994 | 63 mm OD 4 kg/ cm2 |
| 995 | 75 mm OD 4 kg/ cm2 |
| 996 | 90 mm OD 6 kg/ cm2 |
| 997 | SITC of Radial / mixed flow water and anti-corrosive liquid filled submersible motor pump sets suitable for 100/150mm dia borewell. The size of adopter fixed on top of the motor should exceed the top of coupler , for safegaurd the coupler. The job includes labour part of lowering of riser pipe G.I./ H.D.P.E. with rope, cables & pump, installation of complete fitting and accessories, jointing of electrical cables up to Starter. All labour for testing of submersible pumps set and supply of water to water mains, complete in all respect. |
| 998 | 100 mm diameter Submersible pump shall have following HP Rating, phase, Head range, Discharge range respectively. |
| 999 | 1.0 HP, 1-Ø, (10 - 83)Mtr, (40- 10) LPM |
| 1000 | 1.5HP, 1-Ø, (11 - 94)Mtr, (40 - 10) LPM |
| 1001 | 2.0 HP, 1-Ø, (7- 95)Mtr, (55-22) LPM |
| 1002 | 3.0 HP, 1-Ø, (40 -170)Mtr, (60- 20) LPM Copper Wound |
| 1003 | 5.0 HP, 1-Ø, (56 - 236)Mtr, (90 - 25) LPM Copper wound |
| 1004 | 150 mm diameter Submersible pump shall have following HP Rating, phase, Head range, Discharge range respectively. |
| 1005 | 3.0 HP, 3-Ø, (40 -110)Mtr, (280-50) LPM |
| 1006 | 5.0 HP, 3-Ø, (72 - 161)Mtr, (230-48) LPM |
| 1007 | 7.5 HP, 3-Ø, (85-165)Mtr, (300-100) LPM |
| 1008 | 10.0 HP, 3-Ø, (110 - 212)Mtr, (400-167) LPM |
| 1009 | SITC of Monoblock closed coupled motor pump set with TEFC motor, motor should be IP55-F class and IE2 efficiency for monobloc, with carbon steel /SS-410 shaft, Mechanical seal, Single/Three phase Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively and Dynamically balanced rotating parts to ensure min. vibration etc. complete in all respect. |
| 1010 | 5.0 HP, 3-Ø, (19-44)Mtr, (550-300) LPM ( Bronze impeller & CI Body) |
| 1011 | 7.5 HP, 3-Ø, (20-35)Mtr, (1060-400) LPM ( Bronze impeller & CI Body) |
| 1012 | SITC of Pressure boosting pump with MS Tank, pressure switch, pressure gauge, and all standard fittings fully automatic ON / OFF system, 2900 RPM with stainless steel casing, & impellor suitable for following capacity complete in all respect. |
| 1013 | 0.5 HP ( 12 - 26 ) Mtr, (50 - 10 ) with 8 Ltr tank |
| 1014 | 0.75 HP -0.90 HP ( 10 - 34 ) Mtr, (72 - 5 ) LPM with 24 Ltr Tank |
| 1015 | 1.0 HP ( 10 - 38 ) Mtr, (76 - 8 ) LPM with 24 Ltr Tank |
| 1016 | 1.5 HP ( 18-44 ) Mtr, (10-78 ) LPM with 35 ltr tank |
| 1017 | Providing & Fixing of CI foot valve complete in all respect as required. |
| 1018 | 50/ 60 mm |
| 1019 | 80/ 100 mm |
| 1020 | Supply & fixing of GI pipes confirming to IS : 1239 P - 1 ( 2004 ) with socket,elbow,tee, flanges duly screwed & welded including rubber washer, nuts & bolts of 8mm dia complete in all respect. ( If Pipe Laid Underground Excavation and refilling cost will be paid extra) |
| 1021 | 32mm dia |
| 1022 | 40 mm dia. |
| 1023 | 50 mm dia. |
| 1024 | 65 mm dia. |
| 1025 | 80 mm dia. |
| 1026 | 100 mm dia. |
| 1027 | SITC of IP 54 OEM Fabricated DOL/Star-Delta Starter panel with switchgear selection as per Type-2 Coordination Chart and made out from 1.6 mm thick powder coated CRCA sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection(for three phase pumps), Illuminated ON / OFF push buttons, ammeter, voltmeter, indicating lamps, 2P/4P MCB etc. suitable for following rating motors complete in all respect. |
| 1028 | For single phase Submersible / Monoblock pump |
| 1029 | 0.5 HP to 1.5 HP (DOL starter) |
| 1030 | 2.0 HP to 3.0 HP (DOL starter) |
| 1031 | 5.0 HP (DOL starter) |
| 1032 | For Three phase Submersible / Mono block pump |
| 1033 | Upto 3.0 HP ( DOL starter ) |
| 1034 | 3.0 HP to 5.0 HP ( DOL starter ) |
| 1035 | 7.5 HP to 10.0 HP ( DOL starter ) |
| 1036 | 3.0 HP to 5.0 HP ( Star / Delta starter ) |
| 1037 | 7.5 HP to 10.0 HP ( Star / Delta starter ) |
| 1038 | SITC of Interconnecting refrigerant copper pipe for split/Ductable/ Casseette AC of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. Piping between each set of indoor & outdoor units of different sizes as per OEM requirement & specifications including class 'O' Nitrile rubber sleeves (size as per item no. 22.43),7 mil Glass Cloth with 3 coats of anti UV paint (on area which is exposed to weather) chase cutting, supports, making good the same with sand cement plaster etc. as required. |
| 1039 | Hire charges for Cable fault locator machine with manpower for detecting fault in underground cable of LT 1.1 KV grade or 11/33KV HT cable |
| 1040 | for 1st day |
| 1041 | for 2nd day onwartds |
| 1042 | GST@18% Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail