| 1 | Site clearance including removal of shrubs, vegetation, grass, bush, weed,trees and saplings not exc 30 cm in girth including removal pf disposl outside MOD land. |
| 2 | M&L for ploughing the ground using Tractor mounted cultivator upto a depth of 150-200 mm in both directions longitudinally followed by transverse direction including removal of exposed organic matter/debris outside MoD land then roughly levelling the ground in a slope of approx 1-1.5% for drainage all as specified and as directed by Engr-in-Charge. |
| 3 | Supply and stacking of good agricultural earth suitable for plantation as approved by Engr-in-Charge at site to be brought from outside MOD Land. Earth measured in stacks will be reduced by 20% of volume for calculation and payment and to deposit at site as directed by Engr-in-Charge. |
| 4 | Supply and stacking of Vermi compost with following specification as per IS 16702: 2018:(i) Colour: Dark brown to black(ii) Odour: Odourless or pleasant earthy smell(iii) Texture: Fine granular, free flowing(iv) pH Value: 6.5-7.5( Near neutral)(v) Moisture content: 15%-25% at time of packing( upto 40% for storage)(vi) C: N ratio: 14:1 to 15:1 (vii) Material must pass through 3 to 4mm sieve to remove un-decomposed matter & stones |
| 5 | Landscaping of area by forming 4 nos of conical shaped landscape mounds to be created of approx dia 8-10 mtr and height 0.75 to 0.90mtrs including raising earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5 m high from base.NOTE: Supply only earth & Vermi Compost shall be measured and paid under Item no 3 & 4 respectively. |
| 6 | Mixing & spreading of approved stacked earth with Vermi compost in the ratio of 1:1( 1part vermicompost & 1 part soil) by volume in required thickness and levelling the soil in longitudinal slope of 1 to 1.5% for drainage as directed by Engr-in-Charge |
| 7 | Supply & planting of Bermuda 419 grass by stripping method (manual planting) in the prepared ground including necessary tools & plants with transportation charges etc and regular watering covering entire area.NOTES: (i) Watering of the area to be done twice a day or as per requirement/directed by Engr-in-Charge till the completion of the Defect liability period. Water will be supplied by MES.(ii) Removal of weeds/unwanted plants to be done twice a month.(iii) Moving/cutting/trimming of the area to be done twice a month till the completion of Defect liability period.(iv) Worn out/ damaged grass to be replanted at no cost basis till the completion of the Defect liability period.(v) Application of vermicompost/ suitable manure once a month for growth of grass till completion of defect liability period(vi) The rates quoted deemed to have incorporating all the points mentioned above(vii) The rate quoted by the bidder shall be inclusive of maintenance of the aboriculture work in DLP in all respect ie provision of requiste material & labour to maintain the grass/plants all as directed by the GE/Engr-in-Charge for the period of two years comencing from certified date of completion of work. |
| 8 | M&L for Spraying of Bavistin and Dithane M-45 or equivalent make as approved bt GE in the concentration of 0.1% to 0.2%( roughly 1.5 to 2 gram per liter of water covering approx area of 10-15 Sqm per 1 to 2 grams when diluted in 1 litre of water) at an interval of every 15 days till complete growth of grass as per entire satisfaction of Engr-in-Charge/GE. |
| 9 | S & F 3-layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. of 110 mm outer dia ,including fittings complete all as specified and as directed by Engr-in-Charge. |
| 10 | S & F 3-layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete of 63 mm outer dia ,including fittings all as specified and as directed by Engr-in-Charge. |
| 11 | S & F 3-layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. of 25 mm outer dia ,including fittings complete all as specified and as directed by Engr-in-Charge. |
| 12 | Supply and fix PPR Ball Valves (Brass Insert) of 25 mm bore including fittings complete all as specified and as directed by Engr-in-Charge. |
| 13 | Supply & fix sluice valve 100 mm bore cast iron flanged & drilled both ends (ISI marked) Class PN- 1.6, Non Rising stainless steel spindle including all jointing materials and mild steel nuts, bolts, washers and gasket etc complete all as specified and as directed by Engr-in-Charge. |
| 14 | Supply & fix sluice valve 65 mm bore cast iron flanged & drilled both ends (ISI marked) Class PN- 1.6, Non Rising stainless steel spindle including all jointing materials and mild steel nuts, bolts, washers and gasket etc complete all as specified and as directed by Engr-in-Charge. |
| 15 | Supply & fix Straight plain PPR ferrules (or connecting screws) in PPR pipe of 63 mm dia screwed both ends and fixed of 25 mm dia PPR Pipe complete all as specified and as directed by Engr-in-Charge. |
| 16 | Supply and fix garden light LED type 15 watt 230 watt volts AC outdoor type with decorative for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp, GI pole of 50 mm dia upto 1.2 m Height, PCC foundation as per approved design and required qty of nuts, bolts, washers, PVC junction boxes for conenction of electical cable and protection Jali made out of GI wire 4 mm dia (Size of protection Jali shall be of 1.2 mtr height, 30 cm wide of all four side) and PVC insulated FRLSH unsheathed multi-stranded copper conductor cable 1100 volts grade of 1.5 Sqmm (2 Run) of required length for conenction from junction box to connector of light etc complete all as specified and directed by Engr-in-Charge. |
| 17 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 4 core complete all as specified and directed by Engr-in-Charge. |
| 18 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for laying of HT UG Cable in soft/loose soil and getting out complete all as specified and directed. |
| 19 | M & L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. Complete all as specified and directed. |
| 20 | M & L for Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 21 | M & L for Sand filling in trenches as cable protection including watering and consolidation complete all as specified and direted.Note : Punned thickness shall be measured and paid. |
| 22 | M&L for brick protection cover to underground cable with sub-class ‘B’ old size over burnt bricks laid dry and flat across the axis of cable, abutting each other with gaps between adjacent bricks not exceeding 10mm complete all as specified & directed. Please Enable Macros to View BoQ information |