| 1 | Surface excavation not exc. 30 cmm deep and averaging 15 cm deep and getting out in any type of soil complete all as specified and directed. |
| 2 | Excavating over areas, not exc 1.5 m deep andgetting out in soft/loose soil complete all as specified and directed. |
| 3 | Ditto as per Item No 2 Above but depth beyond first 1.5 m and up to 3.0 m and getting out in soft/loose soil complete all as specified and directed. |
| 4 | Excavating over areas, not exc 1.5 m deep andgetting out in soft/disintegrated soil complete all as specified and directed. |
| 5 | Earth work in excavation by mechanical means (Hydraulic excavator) over areas exc. 1.5 m depth including getting out and disposalof excavated earth lead up to 50 m and lif up to 1.5m complete all as specified and directed. |
| 6 | M&l for cement concrete Type B1 14:8 Type D2 using 40 mm graded crushed stone aggregate in foundation filling and mass concrete complete all as specified an directed. |
| 7 | M&L for R C C (design Mix) M- 30 ( 20 mm graded crushed stone aggregate ) as in fountation raft, footing, bases for clouumn, basement slab and mass concrete complete all as specified an directed. |
| 8 | M&L for R C C (design Mix) M- 30 ( 20 mm graded crushed stone aggregate ) as in wall, retaining wall any thickness above footing complete all as specified an directed. |
| 9 | M&L for R C C (design Mix) M- 30 ( 20 mm graded crushed stone aggregate ) as in beam, cantilever, lintels etc complete all as specified an directed. |
| 10 | M&L for R C C (design Mix) M- 30 ( 20 mm graded crushed stone aggregate ) as slabs, landing, balconies deck slab shelves, and the like complete all as specified an directed. |
| 11 | M&L for R C C (design Mix) M- 30 ( 20 mm graded crushed stone aggregate ) as in coloumns, pillars, piers , posts and strut and the like complete all as specified an directed. |
| 12 | M&L for formwork to sides of concrete foundation,footing and similar work to rough finished surface of concrete complete all as specified and directed. |
| 13 | M&L for formwork to face of wall retaining wall parapets similar work to rough finished surface of concrete complete all as specified and directed. |
| 14 | M&L for formwork to beams, beam haunching, similar work to rough finished surface of concrete complete all as specified and directed. |
| 15 | M&L for formwork to slabs, roof slabs, landings, similar work to rough finished surface of concrete complete all as specified and directed. |
| 16 | M&L for formwork to sides of pillars post struts, coloumns of square or rectangular similar work to rough finished surface of concrete complete all as specified and directed. |
| 17 | M&L for Mild steel TMT(CRS) bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, all as specified and directed. |
| 18 | M&L for Mild steel TMT(CRS) bars 6 to 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, all as specified and directed. |
| 19 | Material and labour for cement 1:2:4 type B-1 (20 mm graded stone aggregate) as in flooring levelling course etc complete all as specified and directed. |
| 20 | Excavating in trenches,i n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. and getting out in hard/ dense soil.complete all as specified and directed. |
| 21 | M&L for Mild steel TMT(CRS) bars 6 to 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, all as specified and directed. |
| 22 | M & L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished the surface even and smooth with out using extra cement complete all as specified. |
| 23 | M & L for rendering 5mm thick on fair faces of ceiling in cement mortar 1:6 finished the surface even and smooth with out using extra cement complete all as specified. |
| 24 | M & L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 mixed with water proofing compound @ 3% by weight of cement finished the surface even and smooth with out using extra cement complete all as specified. |
| 25 | Supply only water proofing compound of ISI marked complete all as specified and directed. |
| 26 | M&L for hard core of guage not exc, 63 mm (broken stone or bouldere) deposited spread and levelled in layers not exc. 15 cm thick watered and rolled/rammed in to a true surface complete all as specified and directed. |
| 27 | M&L for hard core of guage not exc, 63 mm (broken stone or bouldere) deposited spread and levelled in layers not exc. 15 cm thick watered and rolled/rammed in to a true surface complete all as specified and directed. |
| 28 | M & L for cement concrete 1:4:8: type B-2 using 40 mm graded stone aggregate, 100 mm thick as in sub base all as specified and directed. |
| 29 | M & L for cement concrete 1:2:4: type B-0 using 12.5 mm graded stone aggregate, 100 mm thick as in flooring finished surface even complete all as specified and directed. |
| 30 | M&L, for machine cut mirror polished kota stone slab flooring 22-25mm thick over cement screed bed in CM (1:4) 15mm thick, & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete all as specified and directed. |
| 31 | M&L, for machine cut mirror polished kota stone slab flooring 22-25mm thick in riser / treads of steps in single piece, skirting, dado and pillar laid over cement screed and jointed withover cement screed bed in CM (1:4) 15mm thick, & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing and rounding the edges where as required complete all as specified and directed. |
| 32 | M&L for PCC 1:3:6 type C-2 (40 mm graded stone aggregate)75 mm thick as in plinth protection finishing the surface even smooth with out using extra cement complete all as specified and directed. |
| 33 | S&F Steel rolling shutters 1.25mm thickness of laths, without ball bearing, as specified including top cover, anchoring rod, hasp and staple; erected in position as indicated, complete:gear operated type with bevel gear box and crank, handle including all assessories and fittings, complete all as specified and directed. |
| 34 | Supply & Fixing upto any floor height powder coated (50 micron minimum thickness) Aluminium anodised frame and shutter for door, windows, ventilators etc. with one or more rebates including joining cleat for fixing etc. fixed type/louvered window or ventilator without sash bar, aluminium including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, sliding rollers, rubber gasket etc. complete all as specified and directed by the Engineer-in-charge. Note:a) Glazing shall be measured separately. b) Item shall be paid as per weight of aluminium section.c) The rate quoted shall be inclusive of neoprene beading, glazing clips, screws, etc., as required which shall not be measured for arriving the weight.d) The rate shall be inclusive of the locking arrangement including complete packing with silicon gel around contacting surfaces of aluminium work, and including matching the existing surface area.Note:- Aluminium window shall be factory made, contractor shall make arrangement for visiting the factory site during the currency of work (if required). The size of aluminium section shall be as per HQ CE(N) MZ TD Drawing No. TD/2021/01 to 05. |
| 35 | S&F in repair aluminium grill with and including suitable aluminium anodised frame F/H section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, as directed by Engr- in- charge. |
| 36 | S&F 4.8 mm thick sheet glass selected quality n exc 0.5Sqm in each pane,fixed to Aluminium windows including rubber beeding etccomplete all as specified and directed. |
| 37 | M&L for preparation of new plastered surface of wall and applying 2 coats of oil emuslion distemper over a coat of primer including 3 mm thick wall care putty complete all as specified and directed. |
| 38 | M&L for preparation of new plastered surface of wall and applying 2 coats of cement base paint over a coat of primer complete all as specified and directed. |
| 39 | M&L for preparation of old plastered surface of ceiling and applying 2 coats of oil emuslion distemper all as specified and directed. |
| 40 | M&L for preparation of newly steel surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer zink chrome complete all as specified and directed. |
| 41 | M&L for preparation of newly wooden surfaes of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer incl preparation of surfaces. |
| 42 | M& L for Exacation on post holes in soft/loose soil not exc 0.50 cum each getting out , returning , filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed. |
| 43 | Material and labour for cement 1:2:4 type B-2 using 40 mm graded crushed stone aggregate) asin filling ,concrete complete all as specified and directed. |
| 44 | Supply only Mild steel galvanised Chain link fencing, any size or type complete all as specified and directed. |
| 45 | Fixing only Mild steel galvanised Chain link fencing, any size or type complete all as specified and directed. |
| 46 | M&L for preparation of newly steel surfaces of any description over 10 cm in width or girth and applying two coats of black japan paint over a coat of red oxide primer zink chrome complete all as specified and directed. |
| 47 | Cutting into existing manholes for connecting new drain making good to200mm pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 Sec) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as reqd for 200mm bore of pipe. |
| 48 | M&L forMild steel Nut and bolt ( Machine made) with hexagonal or squre heads one end and screwed the other fitted with washers length of bolt exc 5 cm not exc 10 cm and dia of neck 10 to 11 mm complete all as specified and directed. |
| 49 | Material and labour for brick work with sub class \\"B\\" bricks, straight or curved on plan exc 6 m mean radius, built in CM (1:6), complete all as specified and directed. |
| 50 | Material and labour for brick work with sub class \\"B\\" bricks, straight or curved on plan exc 6 m mean radius, built in CM (1:4), complete all as specified and directed. |
| 51 | M&L for forming channel or drain inside the manhole with PCC 1:2:4 type B1 using 20mm graded aggregate complete all as specified and directed. |
| 52 | M&L for extra forming fair finishes drain or channel 30CM inner girth in cement complete all as specified and directed. |
| 53 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel in cement concrete 1:2:4 type B1 all complete for pipe upto 225 mm internal dia.complete all as specified and directed by Engr-in-Charge. |
| 54 | M & L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished the surface even and smooth with out using extra cement complete all as specified. |
| 55 | S&F for 200mm bore RCC pipe class NP-2 laid and jointed complete with collers as specified including testing all as specified and directed . |
| 56 | M&L for cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in bed to drain pipes including forming cradle after they are laid and tested for 200mm bore RCC pipe complete all as specified and as directed . |
| 57 | S&F Rolled mild steel in Joist, channel, angle,purlin, or tee sections, fixed independently, without connecting plates, etc, as in vertical post and fixing of post with drilling and fixing with fastener of required size or cutting, welding, reveting etc conforming to Fe-410 (gde E-250) complete all as specified and directed. |
| 58 | S&F Rolled mild steel in Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410 (gde E-250) complete all as specified and directed. |
| 59 | Demolition of cement concrete in ground floor (unreinforced) and in paving in any position including removing debris out side MD land complete all as specified and directed. |
| 60 | M&L for Machine pressed precast concrete interlocking paver block having glossy finish shape and size as approved by GE confirming to IS 15658-2006 of 80mm thickness, M-40 Grade of with grey cement and pigments laid over and including 50 mm thick dry sand cushioning and voids filled with dry and surface compact, including compaction by means of surface vibrator and removing old paver blocks complete all as specified and directed. |
| 61 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. in Hard / dense soil, complete all as specified. |
| 62 | Removal of excavated material from site to distance exc 5.0 Km but not exc 15 Km and depositing where directed , complete all as specified.and directed. |
| 63 | Supply and laying of spigot and socket ductile iron water tubing, class K-9, 150 mm dia cement mortar lining on inner surface and one coat of bituminous paint over exposed surface ISI marked, IS No. 8329: 2000, including rubber joint of suitable size laid on roof/floor/trenches with proper alignment as per site requirement and carryout testing against leakage before filling the trenches etc complete all as specified and directed. |
| 64 | Supply & fix sluice valve 100mm size both ends flanged with high tensile stainless brass spindle, I body as per IS-14846, ISI Marked,PN-1.6 including all joints with rubber or fibre board, nuts, bolts, washers complete all as specified and directed. |
| 65 | Supply & fix of 80 mm dia ERW MS pipe heavy grade including MS fittings confirming IS-1239 and applying two coats of synthetic enamel paint over a coat of red oxide primer to pipe including welding, supporting brackets as required at site complete all as specified and directed. Note : Rate deemed to be inclusive of bituminous wrapping and coating as per IS 15337:2003 for 80 mm NB pipes if required to be laid under ground |
| 66 | Supply & fix 100 mm dia ERW MS pipe heavy grade including MS fittings confirming IS-1239 and applying two coats of synthetic enamel paint over a coat of red oxide primer to pipe including welding, supporting brackets as required at site complete all as specified and directed. Note : Rate deemed to be inclusive of bituminous wrapping and coating as per IS 15337:2003 for 100 mm NB pipes if required to be laid under ground. |
| 67 | Supply & fix 150 mm dia ERW MS pipe heavy grade including MS fittings confirming IS-1239 and applying two coats of synthetic enamel paint over a coat of red oxide primer to pipe including welding, supporting brackets as required at site complete all as specified and directed. |
| 68 | Supply & fix sluice valve 150 mm size both ends flanged with high tensile stainless steel spindle, I body as per IS-14846, ISI Marked,PN-1.6 including all joints with rubber or fibre board, nuts, bolts, washers complete all as specified and directed. |
| 69 | Supply & fix sluice valve 80 mm size both ends flanged with high tensile stainless steel spindle, I body as per IS-14846, ISI Marked,PN-1.6 including all joints with rubber or fibre board, nuts, bolts, washers complete all as specified and directed. |
| 70 | Supply & fix Non return valve (ISI marked) 80 mm size both ends flayed with high tensile stainless steel spindle, I body including all joints with rubber or fibre board, nuts, bolts, washers complete all as specified and directed. |
| 71 | Supply and fix CI foot valve (ISI marked) 80 mm (3\\") dia flanged end IS 4038 PN 0.2 housing complete including replacement of nut bolts, cutting of pipe, welding complete all as specified and directed. |
| 72 | Construction of brick masonery valve chamber of size 1.2 x 1.2 x 1.2 M (internal dimension) (above GL 0.30 mtr) suitable for fixing of sluice valves, 15cm thick foundation using PCC 1:4:8 type D-2 over 15cm thick hardcore of broken stone, 23cm thick brick walls built in cement and sand mortar 1:4, 15mm thick internal and external plaster including top of floor in cement and sand mortar 1:3, 15mm thick, finished even and smooth, without using extra cement, 8 mm thick plate cover on 50mm x 50mm x 6mm MS angle frame embeded in PCC 1:2:4 type B-1coping, having rectangular, hinged, opening of size 150 x 100mm with locking arrangements ,hold fasts, etc, applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surfaces and earth work in any type of soil including disposal of debris outside MD land complete all as specified. |
| 73 | M & L for CI/DI specials conforming to IS - 1538& 9523, spigot /socket or flanged fitting I.e. bend, tee, collar, flanged/ socket /spigot, Tappers, flanges and tail pieces etc suitable for 100/150/200/250/300 mm bore CI/DI pipes (joints and joining material shall be measured and paid seperately) |
| 74 | Supply/Fixing of G I water tubing 25 mm bore , galvanised, Medium grade with all fittings in shafts such as nipple, union, socket, elbow, bends, fixed to wall including necessary & capacity up to 15 th floor in high rise buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/on wall and making good the disturbed surfaces complete all as specified and directed by Engineer-in-charge.Note (1)Work to be carried out in high rise buildings plain wall or in shafts or in terraces or inside the flats for cutting the existing GI pipe line and replace the same with new GI pipe in short piece or full length. complete all as specified and directed. |
| 75 | Supply/Fixing of G I water tubing 80 mm bore , galvanised, Medium grade with all fittings in shafts such as nipple, union, socket, elbow, bends, fixed to wall including necessary & capacity up to 15 th floor in high rise buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/on wall and making good the disturbed surfaces complete all as specified and directed by Engineer-in-charge.Note (1)Work to be carried out in high rise buildings plain wall or in shafts or in terraces or inside the flats for cutting the existing GI pipe line and replace the same with new GI pipe in short piece or full length. complete all as specified and directed. |
| 76 | S&F 1000 ltr PVC water storage Tank with cover 3 layer, ISI marked, pure anti microbail round type and making connections including replacement of new GI fittings i.e. tank nipple, washers, float valves and Gate valves and Pipes for connecting the existing Inlet/delivery lines, testing complete all as specified and directed Note :- Gate valves and GI pipe only shall be paid under relevant item of Schedule 'A' remaining items shall be deemed to be included in the item rate. |
| 77 | Supply and fix 25 mm dia gun metal gate valve (ISI marked) with iron wheel head screwed both ends for iron pipe including fittings i.e. union, socket etc complete all as specified |
| 78 | Supply, installation, testing and commissioning of Electric driven Pump in factory fitted with below requirements complete all as specified and directed.(a) 925 LPM at head of 75 Mtr, Horizontal type, centrifugal, split casing pump body made up of cast iron & enclosed type impeller made up of bronze with stainless steel shaft,with suitable sealing, glands packing conforming to IS 1520.(b) Suitable Squirrel cage IE-2 induction motor ,TEFC, synchronous speed 1500 RPM, suitable for operation. on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated Common base plate,coupling guard, Pressure guage upto 6kg/cm2 of size 150mm dia with accuracy + 2% of foundation bolts etc. as required.(d) Suitable cement concrete foundation duly plastered with anti vibration pads,painting of blue colour to suction and delivery pipe line, MS common base plate coupling guard. (e) One coat of red lead primer of best quality (IS approved ) shall be applied. Finally two (2) coats of Synthetic enamel paint of best quality(IS approved) colour shall be appliedNote:submitting pump performance curves and pump efficiency at site Motor Make :- As approved Pump make :-As approved |
| 79 | Ditto as per item no 78 above but capacity 635 LPM and head 60 mtrs |
| 80 | Supply ,install, testing and commissioning of LT distribution panel 900mm x 700mm x 250mm of suitable size, CPRI type tested, weather/vermin proof, made out of 2mm thick CRCA sheet, factory assembled cubicle pattern modular and compartmentalized construction ,indoor type, with front and backside doors with locking arrangement, floor mounted free standing type ,duly powder coated copper bus bar of 200 amps with epoxy insulated coating with cable galleries comprising of following consisting prewired with ferrule including connection from SCADA PLC Panel to LT Panel & control wiring . (a) 415V MCCB 4P 100 A with thermal magnetic protection unit and thermal adjustable 0.8 to 1 In, Magnetic adjustable 5 to 10In and breaking capacity of 50 KA with suitable spreaders -01 Nos (Incoming)(b) 415V MCCB 3P 63 A with thermal magnetic protection unit and thermal adjustable 0.8 to 1 In, Magnetic adjustable 5 to 10In and breaking capacity of 36 KA with suitable spreaders -03 Nos (Outgoing) (01 Spare)(c) Suitable capacity of Star delta starter ranges for 20 HP to 30 HP pump sets, 3 phase, 415 volt with comprehensive motor protection, programmable over load protection built in RTD and thermistor input with constant current adoptive acceleration and deceleration for smooth start and stop operation of motor. 03 Nos ( 01 No stand by)(d) Selector switch, Push buttons/Indication lamp and other required accessories for panel. (e) Supply and fixing multi meter with suitable CT and PT 0 to 200 Amp and 02 to 415 Volt- 04 Nos (f) Suitable size of RCC foundation for fixing of LT panel including angle frame of suitable size |
| 81 | Supply and lay PVC insulated,PVC outer sheated , FRLS,single core copper cable of size 10 Sqmm in HDPE pipe of suitable size concealed in floor/ clamped in wall/tranch between motor terminal and starter panel complete all as specified and directed. |
| 82 | Supply and fixing, Installation Testing & Commissioning of Indoor type Programmable Logic Controller based Valve Automation and communication Panel suitable for control and/or monitoring of 02 Nos. Pumps, 02 Nos Pressure Transmitter, 02 Nos. Priming Solenoid Valves, 02 Nos. Air release Solenoid Valves, 8 Nos motorized valves (+02 Spare) and 04 Nos. magnetic sensors PrimingTanks-01(2 Levels), energy meters and 01 Nos Ultrasonic level sensor, . The panel should be of suitable size fabricated from 2.0 mm thick CRCA sheet and properly powder coated. PLC with following specifications:-(i) Suitable Digital inputs/ outputs, (ii) 4 serial ports supporting open communication protocol, 01 No. Ethernet port, (iii) Programming software based on IEC to facilitate building of custom built function blocks(iv) Expandable up to 192 DI / DOs. (v) 01 No. SMPS of 5 A rating (Make: As approved )(vi) Suitable no. of interposing relays 24 V D.C. coil rating, 4 pole and 2 A contact rating. (Make: As approved )(vii) Selector Switches as per requirement (Make: As approved ).(vii) Selector Switches as per requirement (Make: As approved ). The control logic shall be as directed by the Engineer In Charge for Automatic Operation of Motor Actuated Valve, Supply: 230V, 50 HzCompatible with OFC based and GPRS communication. Compatible for Wimax Connectivity if required.Mounting: Grouted on floor on angle support /on Wall |
| 83 | Supply and fixing, Installation Testing & Commissioning of Indoor type Programmable Logic Controller based Valve Automation and communication Panel suitable for control and/or monitoring of 20 Nos motorized valves and 24 Nos. magnetic sensors . The panel should be of suitable size fabricated from 2.0 mm thick CRCA sheet and properly powder coated.PLC with following specifications:-(i) Suitable Digital inputs/ outputs, (ii) 4 serial ports supporting open communication protocol, 01 No. Ethernet port, (iii) Programming software based on IEC to facilitate building of custom built function blocks(iv) Expandable up to 192 DI / DOs. (v) 01 No. SMPS of 5 A rating (Make: As approved )(vi) Suitable no. of interposing relays 24 V D.C. coil rating, 4 pole and 2 A contact rating. (vii) Selector Switches as per requirement (Make: As approved)(vii) Selector Switches as per requirement (Make: As approved) The control logic shall be as directed by the Engineer In Charge for Automatic Operation of Motor Actuated Valve, Supply: 230V, 50 HzCompatible with OFC based and GPRS communication. Compatible for Wimax Connectivity if required.Mounting: Grouted on floor on angle support /on Wall Note : For item No 20 & 21 : To make the system fully functional. all panels shall be consisting of the following :-(a) Rack mountable Web Smart Switch with 28 ports and POE for CPE hardware and following specifications:-(i) Number of Ports 24 10/100Base-TX Ethernet ports 2, 10/100/1000BASE-T 2 Combo 10/100/1000BASE-T/SFP.(ii) Port Standard Supply and fixing functions • IEEE 802.3 10BASE-T Ethernet (twisted-pair copper) • IEEE 802.3ab 1000BASE-T Gigabit Ethernet (twisted-pair copper) • IEEE 802.3x Flow Control • IEEE 802.3u 100BASE-TX Fast Ethernet (twisted-pair copper) • IEEE 802.3z Gigabit Ethernet (fiber) ANSI/IEEE 802.3 • IEEE 802.3z Gigabit Ethernet (fiber) ANSI/IEEE 802.3 Switching Capacity • 12.8 Gbps |
| 84 | (b) Hot pluggable 1310 nm multimode/Single mode SFP (mini-GBIC) transceiver, supporting full duplex, Gigabit speeds on multimode/Single mode fiber for distances of up to 550m/550m/10km on 62.5µm/50µm/9µm respectively in a metal housing to reduce EMI and to increase durability(c) Rack Mountable LIU with the following specifications:-(i) Rack Mountable 12 Port Unloaded LIU (ii) Aluminium Base Material(iii) Slim 1 U mounting height (iv) Metal Shelf Aluminium 1.2 mm thick(v) Splice tray Aluminium 0.6mm (vi) Winding Panel – Plastic(vii) Cable Plug – Rubber for minimum 2 cable entries (viii) Adaptor Panel Aluminium 1.5 mm thick(ix) 2 fiber spools built in for 900 um tight buffered fibre storing(x) Capable of storing upto 3 mts of 900 um tight buffered fibre per adaptorMake : Dlink, Ubiquiti, Cisco(d) SC-LC Duplex SM Patch Cord 0.9 mm dia of suitable length (i) Size 0.9mm dia (ii) Insertion Loss <=0.2 db, max 0.3 db(iii) Return Loss PC>=45dB, UPC>=50dB, APC>=60dB (iv) Connector Ferrule Ceramic(v) Apex Offset <50um (vi) Fiber Height +-100nm (vii) End Face Radius of Curvature 7mm |
| 85 | (e) SC Simplex Coupler/Adaptor (i) Insertion Loss <=0.2 dB for Zirconia Sleeve (ii) Sleeve/Ferrule Withdrawl Force 2.0N to 5.9NMake : Dlink, Ubiquiti, Cisco(f) Adaptor Panel (i) 6 port adaptor Panel for SC AdaptorsMake : Dlink, Ubiquiti, Cisco(g) SC-SM-Simplex Pigtail of suitable length(i) Insertion Loss <=0.2 db, max 0.3 db (ii) Return Loss PC>=45dB, UPC>=50dB, APC>=60dB(iii) Connector Ferrule Ceramic (iv) Apex Offset <50um (v) Fiber Height +-100nm(vi) End Face Radius of Curvature 7mm |
| 86 | Seamless Integration of the above PLC Panels into the Existing SCADA System incorporating (a) Development:(i) SCADA Screens for new Updated Panel configuration(ii) Layout for App new Updated Panel configuration(iii) Report Format new Updated Panel configuration(b) On-site development:(i) Modifications in SCADA Screens (ii) Modifications in reporting format(iii) Modifications in App layout Please Enable Macros to View BoQ information |
| 87 | Seamless Integration of the above PLC Panels into the Existing SCADA System incorporating (a) Development:(i) SCADA Screens for new Updated Panel configuration(ii) Layout for App new Updated Panel configuration(iii) Report Format new Updated Panel configuration(b) On-site development:(i) Modifications in SCADA Screens (ii) Modifications in reporting format(iii) Modifications in App layout Please Enable Macros to View BoQ information |