| 1 | RE- ELECTRIFICATION (INTERNAL) |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 3 | Group B |
| 4 | Wiring for One light point controlled by 10A SP MCB with 2x1.5 and earthing with 1.5 sq mm PVC insulated copper coductor earth wire in surface/recessed medium class PVC conduit etc. as required.(without cost of sp mcb) |
| 5 | Wiring for circuit wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. |
| 6 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 7 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 8 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 9 | Wiring for submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. |
| 10 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 11 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 12 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 13 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 14 | 2 Pair |
| 15 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 16 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. (For telephone, tv socket and bell push) |
| 17 | 1 or 2 Module |
| 18 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A Modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 19 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 20 | Wiring for group controlled (looped) light point/fan point/exhaust fan/point (without independent switch etc.) with 1.5 sq. mm PRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. |
| 21 | Group B |
| 22 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB \\"C\\" curve including connections, painting etc. as required. |
| 23 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 20 A modular socket outlet and 20 A modular SP MCB \\"C\\" curve including connections, painting etc. as required. |
| 24 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) |
| 25 | 6 Way Double Door |
| 26 | 8 Way Double Door |
| 27 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) |
| 28 | 6 Way ( 4+18 ) Double Door |
| 29 | 8 Way ( 4+24 ) Double Door |
| 30 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing an commissioning etc. as required. |
| 31 | Single pole |
| 32 | Supplying and fixing TP sheet steel enclosure on surface/ recess along with 415 V \\"C\\" curve TP MCB complete with connections, testing and commissioning etc. as required. |
| 33 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 34 | Supplying and fixing DP Following Rating, Double Pole, ( Single Phase & Neutral ) 240V, Residual Current Circuit Breaker ( RCCB), having a Sensitivity Current 30 mA in the Existing DP MCB complete with connections, testing and commissioning etc. as required. |
| 35 | Supplying and fixing DP Following Rating, Double Pole, ( Three Phase & Neutral ) 415 V, Residual Current Circuit Breaker ( RCCB), having a Sensitivity Current 30 mA in the Existing DP MCB complete with connections, testing and commissioning etc. as required. |
| 36 | Providing & Fixing IK 09 Rating Recessed/Surface Mounting Heavy Duty Vertical Type Sheet Steel 1.6 mm thick Distribution Board for Electrical Work ISI Marked Conforming to IS -13032 & IS- 8623/ Conforming to IEC61439-3 with Provision of Incomer Suitable for MCCB and SP/TPMC outgoing, Phosphatised, Powder Painted Complele with Insulated Suitable Rating Cu. Busbar, Neutral link ,Earth link and din bar , masking sheet , including making internal Db Termination with Copper lugs and with dectacchable gland Plat, Testing etc. as required complete in all respect . |
| 37 | 8 Way (IP43-DD with Provision of Incomer MCCB-100/125/160 Amp Rating. |
| 38 | 8 Way (IP43-DD with Provision of Incomer MCCB-200/250 Amp Rating. |
| 39 | Supplying and fixing following Sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required (for Submain Wire ). |
| 40 | Supply and fixing surface mounting LED down lighter, LED of 15w assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy > 100 lm / Watt. LED driver PF > 0.95, THD < 20% & surge protection 4 KV. The colour rendering index of LED light should be more than 70. Housing made of pressure die cast aluminium / CRCA powder coated frame with glare free diffused polycarbonate cover. |
| 41 | Supply and fixing Led tube rod comprising of LED tube battan with non integral / integral driver, upto 6500K color temp having 40000 burning hrs life with minimum @L70 , system lumen output should be minimum with system efficacy > 100lm /Watt . LED driver PF > 0.95 &THD. |
| 42 | Tube light LED 1X18 Watt, Integral i/c batten aluminium body, PC diffuser. |
| 43 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP 20, CRI > 80, Flicker free, ( flicker should be below 5 % ), life time (LED, Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000 K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark / Name Engraved / Embossing / Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM 79 & LM 80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) |
| 44 | 36 watt |
| 45 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req |
| 46 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 47 | Supplying,erecting and testing of approved make exhaust fan heavy duty with mounting frame, blades AC 230-250 complete connection and including, frame bolt/anchor hole fasteners etc. complete finished and as required |
| 48 | 300mm sweep RPM 900 / 1400 |
| 49 | EPABX SYSTEM |
| 50 | SITC of EPABX system with following specification: Nos of line: 06 (Minimum) Nos of Extension: 24 {02 DKP, 22 STL (upto)} Other Features: Hotline, Live Call Supervision, Auto Call Back, Automatic Call Disconnector, Auto Redial, Call Splitting, Call Conference, Direct Inward Dialing, External call forwarding, Exccutive / Secretary etc |
| 51 | SITC of Telephone Operator console with LED light indication, call forwording, Call Splitting, call Conference etc, (Make: Matrix/Panasonic) |
| 52 | SITC of fully featured CLI Telephone. (Make:Cisco/Panasonic/Beetel) |
| 53 | SITC of 10 Pair Telephone DB, Powder coated,Epoxy Painted sheet steel 18SWG with Backmounting frame, original KRONE Module and locking arrangement. |
| 54 | DISMANTLING OF CIVIL & ELECTRICAL WORKS |
| 55 | Dismantling of point/circuit wiring accessories |
| 56 | Dismantling of existing light/fan/ bell/socket out let point on separate board/wiring and circuit with insulated wire in casing/conduit/ batten complete with fitting and accessories |
| 57 | Making the site clear of the dismantled installation by refilling the hole with cement mortar & finished with paint gitties and replacing to match the colour& wall ceiling. |
| 58 | Dismantling the existing ceiling/exhaust/cabin fan with complete accessories and making the site clear. |
| 59 | RE- ELECTRIFICATION (EXTERNAL) |
| 60 | MIMIC shall be made of polycarbonate sheet of 5 mm thickness fixed on acylic sheet of 2mm thick.the size of panel shall be such that the diagram can be visualized from 5 to 6 meter distance. The panel shall display complete single line diagram of Main LT Panel this line diagram shall be made from luminous non fading materials to glow in dark and each breaker legend shall be provided with bi-colour LED lights to show the ON/OFF status of the respective feeder (Incomers / Bus couplers) |
| 61 | 50 KA fault level continous Al Earth Bus shall be part of Panel for full length of panel |
| 62 | FOR SENSING MAINS, AUTOLOAD MANAGEMENT, OPERATION OF MAINS INCOMERS, BUSCOUPLERS, MCCBs, INTERFACE WITH DG SETS PCC. PLCMAIN LT PANEL / Capacitor Panel as described as above (Sr. No. A to M ) and as per specification complete in all respects. |
| 63 | Main LT panel Capacitor Panel as described as above (Sr. No. A to M ) and as per specification complete in all respects. |
| 64 | Electrolytic high conductivity Aluminium three phase and neutral busbars rated at 125 Amps, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. Current density of Bus Bar to be 1.0 sq.mm / amp.1 Nos. 40 A FP, MCB of 10 KA breaking capacity.12 Nos. 25 A FP, MCB of 10 KA breaking capacity. 01 Nos. 25 A FP, MCB of 10 KA breaking capacity.UPS PANEL as described above . |
| 65 | LIFT PANEL Digital Multifunction meter with RS-485 communication port for measurement of PF, V, A & Hz , equivalent to EM6459,with CT as required. Makes- Trinity , Secure etc.Phase indicating lamps RYB with 6 Amps SP MCB back up. if Required.Electrolytic high conductivity copper three phase and neutral busbars rated at 80 Amps, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. Current density of Bus Bar to be 1.0 sq.mm / amp.2 Nos. of 63 Amp TP, MPCB (10 kA) breaking capacity. . 2 Nos. of 40 Amp TP MCB of 10 kA breaking capacity.1 Nos. of 40 Amp DP MCB of 10 kA breaking capacity.2 Nos. of 63 Amp TP, MPCB (10 kA) breaking capacity.1 Nos. of 40 Amp TP MCB of 10 kA breaking capacity. . LIFT PANEL as described above . |
| 66 | SPARE 1 Nos. 100 Amps 50KA 440 volt TPN, MCCB with overcurrent, inbuilt earth fault and short circuit releases each complete with:1 Nos. 63 Amps 50KA 440 volt TPN, MCCB with overcurrent, inbuilt earth fault and short circuit releases each complete with:1 Nos. 250 Amps 50KA 440 volt TPN, MCCB with overcurrent, inbuilt earth fault and short circuit releases each complete with:Makes- Accord Automation, Super Pannel etc.COMMON PANEL as described above . |
| 67 | SPARE 2 Nos. 125 Amps 50KA 440 volt TPN, MCCB with overcurrent, inbuilt earth fault and short circuit releases each complete with:2 Nos. 63 Amps 50KA 440 volt TPN, MCCB with overcurrent, inbuilt earth fault and short circuit releases each complete with:1 Nos. 200 Amps 50KA 440 volt TPN, MCCB with overcurrent, inbuilt earth fault and short circuit releases each complete with:Makes- Accord Automation, Super Pannel etc.Sub Panel-01 as described above . |
| 68 | SAPRES 1 Nos. 160 Amps 50KA 440 volt TPN, MCCB with overcurrent, inbuilt earth fault and short circuit releases each complete with:2 Nos. 63 Amps 50KA 440 volt TPN, MCCB with overcurrent, inbuilt earth fault and short circuit releases each complete with:Makes- Accord Automation, Super Pannel etc.Sub Panel-02 as described above |
| 69 | SAPRES 2 Nos. 125 Amps 50KA 440 volt TPN, MCCB with overcurrent, inbuilt earth fault and short circuit releases each complete with:2 Nos. 63 Amps 50KA 440 volt TPN, MCCB with overcurrent, inbuilt earth fault and short circuit releases each complete with:1 Nos. 200 Amps 50KA 440 volt TPN, MCCB with overcurrent, inbuilt earth fault and short circuit releases each complete with:Makes- Accord Automation, Super Pannel etc.Sub Panel-03 as described above . |
| 70 | SPARES 1 Nos. 125 Amps 50KA 440 volt TPN, MCCB with overcurrent, inbuilt earth fault and short circuit releases each complete with: 2 Nos. 63 Amps 50KA 440 volt TPN, MCCB with overcurrent, inbuilt earth fault and short circuit releases each complete with: 1 Nos. 100 Amps 50KA 440 volt TPN, MCCB with overcurrent, inbuilt earth fault and short circuit releases each complete with: Makes- Accord Automation, Super Pannel etc. Sub Panel-04 as described above |
| 71 | 30 KVA (3 phase input & 3 phase output) |
| 72 | Supply, installation, testing and commissioning of 12/24V Battery system in series/parallel combinations or assingleas per requirement including interconnetion wiring, lugs and other required material as required with maunting stand/trolley, warranty period: Minimum 3 year |
| 73 | Electrolytic high conductivity Aluminium three phase and neutral busbars rated at 125 Amps, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. Current density of Bus Bar to be 1.0 sq.mm / amp.3 Nos. 40A DP MCB 10 KA breaking capacity controlled by 3 Nos 40 A DP contactor and Timer.18 Nos. 25A DP MCB 10 KA breaking capacity.EXTERNAL LIDHTING DB- X (Typ. for DB-Y) described as above and all as per specification. |
| 74 | MIMIC shall be made of polycarbonate sheet of 5 mm thickness fixed on acylic sheet of 2mm thick.the size of panel shall be such that the diagram can be visualized from 5 to 6 meter distance. The panel shall display complete single line diagram of Main LT Panel this line diagram shall be made from luminous non fading materials to glow in dark and each breaker legend shall be provided with bi-colour LED lights to show the ON/OFF status of the respective feeder (Incomers / Bus couplers)Makes- Accord Automation, Super Pannel e50 KA fault level continous Al Earth Bus shall be part of Panel for full length of panelFOR SENSING MAINS, AUTOLOAD MANAGEMENT, OPERATION OF MAINS INCOMERS, BUSCOUPLERS, MCCBs, INTERFACE WITH DG SETS PCC. PLCMAIN LT PANEL / Capacitor Panel as described as above (Sr. No. A to M ) and as per specification complete in all respects. |
| 75 | 3.5 x 300 Sq.mm. |
| 76 | 3.5 x 240 Sq.mm. |
| 77 | 3.5 x 185 Sq.mm. |
| 78 | 3.5 x 150 Sq.mm. |
| 79 | 3.5 x 120 Sq.mm. |
| 80 | 3.5 x 70 Sq.mm. |
| 81 | 3.5 x 50 Sq.mm. |
| 82 | 3.5 x 35 Sq.mm. |
| 83 | 4 x 16 Sq.mm. |
| 84 | 3 x 6 Sq.mm. For External Lighting all Around Main Hospital Building |
| 85 | Control Cables |
| 86 | Supply of following sizes of 1.1 KV PVC insulated, inner & outer PVC sheath extruded type ST-2, Copper conductor, armoured cables conforming to IS : 7098 (Part-II) and as per specification.(For HT Panel controls, Transformer Protection, PLC controls.) including cost of termation. |
| 87 | 12 x 2.5 sq. mm. |
| 88 | 10 x 2.5 sq. mm. |
| 89 | 6 x 2.5 sq. mm. |
| 90 | 4 x 2.5 sq. mm. |
| 91 | 2 x 2.5 sq. mm. |
| 92 | 2 x 1.5 sq. mm. Cu. Shielded Cable |
| 93 | INSTALLATION OF EQUIPMENTS |
| 94 | INSTALLATION, TESTING & COMMISSIONING: Unloading, receiving, Storing, handling, shifting to place of work, installation, laying, effecting proper connections, testing, commissioning as per manufacturer's instruction and as per specification and as required at site of work and handing over of the following: |
| 95 | LT /DG/CAPACITOR PANEL, DISTRIBUTION PANEL |
| 96 | MAIN LT PANEL ( MAIN HOSPITAL BUILDING ) |
| 97 | CAPACITOR PANEL |
| 98 | UPS PANEL |
| 99 | LIFT PANEL |
| 100 | DISTRIBUTION PANEL |
| 101 | VTPN DB |
| 102 | COMMON PANEL |
| 103 | Total carried over to Summary (I) |
| 104 | FEEDER PILLARS |
| 105 | Street Lighting Feeder Pillar. |
| 106 | SUPPLY, INSTALLATION, TESTING, COMMISSIONING AND HANDING OVER OF THE FOLLOWING: |
| 107 | LT CABLES |
| 108 | The rates for all items of work shall include : |
| 109 | Excavation of trenches, sand filling, covering with bricks and back filling. |
| 110 | Effecting adequate terminations and connections. |
| 111 | Providing lugs, solder / crimping etc. at joints and terminations as called for. |
| 112 | Use of Brass or G.I. thimbles for earthing. |
| 113 | Receiving, shifting, laying, testing and commissioning of following sizes of 1.1 KV grade XLPE insulated aluminium conductor armoured power cables conforming to IS : 7098 (Part-II) laid in existing Hume pipe / PVC pipe / GI pipe and existing cable tray in an approved manner complete as required and as per specifications and dressing of the cable in an approved manner complete as required as per IS1255 and as per drawing. (Necessary end sealing when cables laid in hume pipe shall be done by contractor) |
| 114 | 3.5 x 300 Sq.mm. |
| 115 | 3.5 x 240 Sq.mm. |
| 116 | 3.5 x 185 Sq.mm. |
| 117 | 3.5 x 150 Sq.mm. |
| 118 | 3.5 x 120 Sq.mm. |
| 119 | 3.5 x 70 Sq.mm. |
| 120 | 3.5 x 50 Sq.mm. |
| 121 | 3.5 x 35 Sq.mm. |
| 122 | 4 x 16 Sq.mm. |
| 123 | 3 x 6 Sq.mm. For External Lighting all Around Main Hospital Building |
| 124 | Supply and making terminal joints for the following sizes of 1.1 KV XLPE insulated, Aluminium conductor armoured cable including providing terminal Cu./ Bimetallic Lugs lugs, crimping the joints effecting terminal connections to the equipment complete as required double brass compression gland. |
| 125 | 3.5 x 300 Sq.mm. |
| 126 | 3.5 x 240 Sq.mm. |
| 127 | 3.5 x 185 Sq.mm. |
| 128 | 3.5 x 150 Sq.mm. |
| 129 | 3.5 x 120 Sq.mm. |
| 130 | 3.5 x 70 Sq.mm. |
| 131 | 3.5 x 50 Sq.mm. |
| 132 | 3.5 x 35 Sq.mm. |
| 133 | 4 x 16 Sq.mm. |
| 134 | 3 x 6 Sq.mm. For External Lighting all Around Main Hospital Building |
| 135 | Control Cables |
| 136 | Receiving, laying, testing and commissioning of following sizes of 1.1 KV PVC insulated, Copper conductor, armoured cables in existing open trench complete as required. |
| 137 | 12 x 2.5 sq. mm. |
| 138 | 10 x 2.5 sq. mm. |
| 139 | 6 x 2.5 sq. mm. |
| 140 | 4 x 2.5 sq. mm. |
| 141 | 2 x 2.5 sq. mm. |
| 142 | 2 x 1.5 sq. mm. Cu. Shielded Cable |
| 143 | Control Cable Termination |
| 144 | Supply and making terminal joints for the following sizes of 1.1 KV PVC insulated Copper conductor cable including providing terminal copper lugs, crimping the joints effecting terminal connections to the equipment complete as required brass double compression gland. |
| 145 | 12 x 2.5 sq. mm. |
| 146 | 10 x 2.5 sq. mm. |
| 147 | 6 x 2.5 sq. mm. |
| 148 | 4 x 2.5 sq. mm. |
| 149 | 2 x 2.5 sq. mm. |
| 150 | 2 x 1.5 sq. mm. Cu. Shielded Cable |
| 151 | EARTHING SYSTEM & CABLE TRAY ( MAKES : GENIUS PROTECTION , JMB, GS ELECTROCONTROLS ETC. ) |
| 152 | Supply and installation of Pipe Earthing using Electrode of size 40 mm dia, 4.5 meter long connected with 50X6 mm Copper internal strip complete with excavation, civil works, cast iron cover with back fill compound. The voltage between Neutral & Earth not to exceed 0 volts & IR value less than 1 ohm. The earth resistance shall be as per IS 3043 for Neutral Earthing. |
| 153 | Supply and installation of Pipe Earthing using Electrode of size 40 mm dia, 4.5 meter long connected with 25X5 mm G.I. internal strip complete with excavation, civil works, cast iron cover with back fill compound. The voltage between Neutral & Earth not to exceed 0 volts & IR value less than 1 ohm. The earth resistance shall be as per IS 3043 for Body Earthing. |
| 154 | Supply and installation of Pipe Earthing using Electrode of size 40 mm dia, 4.5 meter long connected with 50X6 mm G.I. internal strip complete with excavation, civil works, cast iron cover with back fill compound. The voltage between Neutral & Earth not to exceed 0 volts & IR value less than 1 ohm. The earth resistance shall be as per IS 3043 for Body Earthing . |
| 155 | Supply and laying in position the following GI tape/wires including providing all fixing accessories and effecting proper connections including clamping to wall with suitable clamp / Saddle and fixing bolts / Soldering / rivetting in ground including the cost of digging & back filling as required & complete as required to comply with IS 3043. All joints shall be tinned. |
| 156 | 25 x 5 mm GI tape |
| 157 | 25 x 5 mm CU tape |
| 158 | 50 x 5 mm GI tape |
| 159 | 50 x 5 mm CU tape |
| 160 | CABLE TRAY ( MAKES: MEM, KME, OBO ETC.) |
| 161 | Supply and Fixing & installation of following sizes of MS Perporated type cable trays fabricated from 2 mm thick sheet steel with stove enamel paint of approved colour with necessary factory made bends, tees, reducer couplers, dashfastners,GI nuts bolts including cutting,bending, drilling, bolting etc.complete as per specifications and as approved by Project Manager, including providing required MS supports fabricated from steel flats, angles, bars, channels as required for fixing/hanging cable trays duly painted with one coat of primer and 2 coats of synthetic enamel paint of approved colour etc. complete as per specifications and as approved by Project Manager. |
| 162 | 600 mm wide, 75 mm high Perforated Type. |
| 163 | 300 mm wide, 62.5mm high Perforated Type. |
| 164 | 100 mm wide, 50 mm high Perforated Type. |
| 165 | Fitting and Accessories : The following fittings shall be provided:- a) Two earthing terminals with the earthing symbol b) Oil level gauge indicating oil levelat minimum, 30°C and maximum operating temperature; c) Air release device (for non-sealed type transformers) d) Rating and terminal marking plates; e) Silica gel breather f) Drain-cum-sampling valve (¾″ nominal size thread, IS 554) preferably steel with plug for three phase transformers; g) Thermometer pocket with cap; h) Oil filling holes having (1¼″ nominal size thread) with cover (for sealed type transformers without conservator); i) Lifting lugs for the complete transformer as well as for core and winding assembly; j) Pressure relief device or explosion vent above 200 kVA; k) One filter valve on the upper side of the tank (for transformers above 200 kVA); l) Unidirectional flat rollers (for transformers above 200 kVA); m) Inspection hole (for transformers above 200 kVA); n) HV side neutral grounding strip (where one of the HV bushing terminal is connected to earth); o) Buchholz relay for transformers above 800 kVA. p) Arcing horns or suitable rating lightning arrestors for HT side – 3 Nos. q) Bird guard; r) Oil temperature indicator and winding temperature indicators for transformers above 200 kVA with suitable tripping mechanism above permissible limit s) Jacking pads (for transformer above 1 600 kVA); t) Additional Neutral separately brought out on bushing for earthing. u) Magnetic oil level gauge (for transformer above 1600 kVA) with low oil level alarm contact; v) Non return valve (for conducting pressure test); w) Pressure relief device or explosion vent x). Monogram Plate y) Inspection cover z). Detachable type radiators with top and bottom shutoff valve. aa) Oil Conservator with Oil level indicator, minimum level marking and drain plug for all transformers of capacity 50 KVA and above. bb) Necessary hardware, clamps, lugs etc. for termination on HV/MV etc. for all transformers. Please Enable Macros to View BoQ information |