| 1 | Earthwork in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 Sq. m on plan), including dressing of sides & remaining of bottoms , lift upto 1.5 m , including getting out the excavated soil and disposal of surplus excavated soil as directed , within a lead of 50 m |
| 2 | All kinds of soil. |
| 3 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering - All work up to plinth level : |
| 4 | 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 5 | 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 6 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses,string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills,fillets etc upto floor V level, including curing but excluding the cost of centring, shuttering and finishing with. |
| 7 | 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 8 | 1:5:10 (1 cement : 5 coarse sand : 10 graded brick aggregate 40 mm nominal size) |
| 9 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 10 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 11 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 12 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 14 | Foundations, footings, walls, bases of columns, etc. for mass concrete. |
| 15 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 16 | Suspended floors, roofs, landings, balconies and access platform. |
| 17 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 18 | Stairs (excluding landings) |
| 19 | Edges of slabs and breaks in floors and walls. |
| 20 | Under 20 cm wide |
| 21 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. |
| 22 | Cold twisted/TMT bars |
| 23 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (at all levels) in all shapes and sizes in : |
| 24 | Cement mortar 1: 6 (1 cement: 6 coarse sand) |
| 25 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 26 | 200x10 mm |
| 27 | Providing and fixing aluminium D handles ISI marked (powder coated) with necessary screws etc. complete : |
| 28 | 200 mm |
| 29 | Providing and fixing aluminium floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868)transparent or dyed to required colour and shade with necessary screws etc. complete. |
| 30 | Single rubber stopper |
| 31 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc. complete. |
| 32 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. |
| 33 | Granite of any colour and shade |
| 34 | Area of slab over 0.50 sqm. |
| 35 | Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 36 | Hot finished welded type tubes. |
| 37 | Design, fabrication, and installation of a permanent PTFE-Coated Fiberglass Tensile Membrane Roofing system, including complete structural engineering, form-finding, and wind-load analysis; providing and fixing high-tenacity PTFE fabric (minimum weight 1150g/sqm) with Class ‘A’ fire rating and self-cleaning top coat; including all Grade 6063-T6 Aluminum extruded clamping profiles, UV-resistant EPDM gaskets for 100% waterproofing, Hot Dip Galvanized or SS316 high-tensile boundary cables with forged turnbuckles, and all necessary specialized rigging, hydraulic tensioning, and safety systems, complete with a 15-year manufacturer’s warranty against UV degradation and structural defects. |
| 38 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 , of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 39 | Size of tile 600x600 mm |
| 40 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer) with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make in all colours & shade in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. |
| 41 | Size of Tile 600x600 mm |
| 42 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete. |
| 43 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete |
| 44 | Providing gola 75x75mm in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1:3(1 cement : 3 fine sand) as per standard design |
| 45 | In 75x75mm deep chase |
| 46 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400 micron, finished with 12mm cement plaster 1:3 (1 cement :3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 47 | 12 mm cement plaster of mix : |
| 48 | 1:6 (1 cement: 6 fine sand) |
| 49 | 15 mm cement plaster on the rough side of single or half brick wall finished with a floating coat of neat cement of mix : |
| 50 | 1:6 (1 cement: 6 fine sand) |
| 51 | 6 mm cement plaster of mix : |
| 52 | 1:3 (1 cement: 3 fine sand) |
| 53 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 54 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade. |
| 55 | New work (two or more coats) over and including water thinnable priming coat with cement primer. |
| 56 | Finishing walls with Acrylic exterior paint of required shade : : |
| 57 | New work (Two or more coat and including priming coat of exterior primer applied @ 2.20 kg/10 sqm). |
| 58 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 59 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: |
| 60 | (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. |
| 61 | (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. |
| 62 | (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. |
| 63 | (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. |
| 64 | (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : |
| 65 | With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 66 | Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991,in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm diafully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. |
| 67 | With 15 mm thick regular edged light weight calcium silicate false ceiling tiles. |
| 68 | Providing and fixing in position wall panelling at all heights with integral densified calcium silicate panels/tiles of size 595 x 595mm, having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity <0.043 W/m K as per ASTM 518:1991, comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mm thick pressed section (galvanizing @120 grams per sqm including both sides) i.e. vertical studs of size 48 x 34 x 36 mm are placed at 600mm center to center in a floor and ceiling channel section of size 50 x 32m fixed to the floor and soffit at 600mm centers using 12mm dia,50mm long wedge type expanded zinc alloy dash fastner with 10mm bolt. This same channel is then to be fixed in horizontal direction at 600mm center to center so as to form a grid of 600mm x 600mm. Glasswool of 50mm thickness is then to be inserted in the slots and finally calcium silicate non combustible panels/tiles are to be screw fixed with self tapping pan head nickel coated mild steel screws of size 13 x 3.2mm on to this grid leaving an even groove of 1 mm between the panels. The joints between the panels are to be duly jointed and finished using recommended jointing calcium silicate based compound and fiber joint tape roll 50mm wide (90 metre) roll and two coats of primer suitable for panelling as per manufacturer’s specification as per direction of Engineer-in-Charge all complete. |
| 69 | With 15 mm thick fully perforated square/butt edge lightweight calcium silicate panels/ tiles |
| 70 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 71 | For fixed portion |
| 72 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 73 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). |
| 74 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 75 | Providing and fixing ACP in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . |
| 76 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 77 | With float glass panes of 5.0 mm thickness |
| 78 | Providing and fixing wire gauge in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 79 | Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P brass/ stainless steel screws @ 200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment) |
| 80 | Providing and fixing aluminium lock handles for aluminium sliding shutters. |
| 81 | Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. |
| 82 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 83 | Circular tank |
| 84 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size),foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete |
| 85 | Inside size |
| 86 | 300 x 300 mm |
| 87 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size),foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design. |
| 88 | Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (medium duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : |
| 89 | With common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 |
| 90 | Providing and fixing following PVC pipes alongwith necessary assesories and fitting (such as tee, elbow, bends etc )complete items |
| 91 | PVC pipe (150 mm nominal dia) |
| 92 | PVC pipe (100 mm nominal dia) |
| 93 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: |
| 94 | W.C. pan with ISI marked white solid plastic seat and lid. |
| 95 | Providing and fixing viterous china wash basin of approved make, size and colour,with 32 mm C.P. brass waste of standard pattern, including fittings and brackets, fasteners etc. complete in all respects as per the direction of Engineer-in-charge |
| 96 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required |
| 97 | Kitchen sink without drain board |
| 98 | 610x460mm bowl depth 200mm |
| 99 | Providing and fixing C.P. brass mixer /pillar cock of approved quality and make |
| 100 | 15 mm nominal bore. |
| 101 | Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 893 |
| 102 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 103 | Providing and fixing C.P. soap dish |
| 104 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. |
| 105 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 106 | Flexible pipe |
| 107 | 32 mm dia |
| 108 | Providing and fixing 100 mm CP grating. |
| 109 | Providing and fixing un plasticized P.V.C. connection pipe with PTMT nuts, collars and bush of approved quality and colour |
| 110 | 15 mm nominal bore with 30 cm length. |
| 111 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 112 | 15 mm nominal bore. |
| 113 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. : Internal work – Exposed on wall. |
| 114 | 15 mm dia. nominal bore |
| 115 | 20 mm dia. nominal bore |
| 116 | SUB-DISTRIBUTION BOARDS |
| 117 | Providing and fixing 6 amps to 32 amps rating 240 volts, 'L' series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as reqired (category B) |
| 118 | Single Pole |
| 119 | Triple Pole and neutral |
| 120 | Triple Pole |
| 121 | Supply and fixing of following rating, 2P 230 volts, SPN in the existing MCB DB complete with connections, testing and commissiong etc. as required |
| 122 | 40 amps SPN |
| 123 | 63 amps SPN |
| 124 | EARTHING AND LIGHTNING PROTECTION |
| 125 | Earthing with GI earth plate 600mm x 600 mm x 6mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) complete as required for earthing and lightning protection. |
| 126 | Providing and fixing 25 mm x 5mm GI strip from earth electrode as required |
| 127 | DISTRIBUTION BOARD |
| 128 | Supply, installation, testing at works, installation and commissioning of following distribution boards totally enclosed compartmentalized, cubicle indoor type fabricated with 16 SWG sheet steel, with Aluminium bus bars (both for main and neutral bus bars), complete with following switchgear/ mountings cable terminations, inter-connections as required, for 415 volts, 3 phase, 4 wire 50 HZ AC supply as per specifications and drawings. |
| 129 | Moulded case circuit Breakers shall be thermal magnetic trip type. Fault level for all MCCB and bus bar shall be 35 KA. ICU shall be equal to ICS=100% |
| 130 | Note : |
| 131 | All metering current transformers shall be Class 1, 15 VA. |
| 132 | MDB-1 (Indoor Type) |
| 133 | Incomer |
| 134 | 125 A 4P MCCB – 1No. |
| 135 | R,Y,B phase indicating lights with control fuses - 1 set |
| 136 | Bus Bar |
| 137 | 125 A 415V, 50Hz, 3ph, 4 wire Aluminium Bus bar |
| 138 | Outgoing |
| 139 | 40 Amp TPN - 2 No. |
| 140 | 63 Amp TPN - 2 No. |
| 141 | 40 Amp SPN - 1 No. |
| 142 | 63 Amp SPN - 1 No. |
| 143 | Supply and laying of PVC Power cable 1.1 KV Grade armoured aluminium XLPE cables including earth work, cost of end termination, thimbles and saddles etc. as required. |
| 144 | 3.5C x 95 sq.mm |
| 145 | SUB-DISTRIBUTION BOARDS |
| 146 | Supply and fixing of the following way, single pole and neutral / three pole and neutral, sheet steel, double door, phase segregation type, MCB distribution board, 230V / 415V on surface/recess, complete with tinned copper bus bar, neutral bus bar and link, earth bar, din bar, detachable gland plate, interconnections, including painting, earthing, etc., as required. |
| 147 | 4 way TPN |
| 148 | 12 way SPN |
| 149 | Supply and fixing 2x2 36 watt LED recess panel with connection testing etc. as reqd.(LCTLRN -36- FO- CDL) |
| 150 | Supply and fixing of 18 Watt LED Panel recess mounted including connection testing etc as reqd. (CAT No. LSCRM-18-CDL) |
| 151 | Supply and fixing of 18 Watt LED Panel surface mounted including connection testing etc as reqd. (CAT No. LCDSPLN-R-18-CDL) |
| 152 | Supply and fixing of 70 Watt LED street light with GI pipe bracket with all accessories including connection testing. |
| 153 | WIRING |
| 154 | Wiring for light / fan / exhaust fan / call bell point with 1.5 Sq mm FR PVC insulated copper conductor cable in surface / recessed ISI marked PVC conduit(2mm thick) including modular switch, modular plate suitable box and earthing the point with 1.5 sq mm FRLS pvc insulated copper conductor single core cable etc as requried |
| 155 | Light point on board with copper wiring in ISI marked PVC conduit wiring for 3 Pin 6 amp plug point with 1.5sqmm PVC insulated multistrand copper conductor cable including P/F of modular switch, modular plate suitable box and earthing the point earth the as required with 01 No. PVIC insulated green colour wire. |
| 156 | Wiring for light plug with 2 x 2.5sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked PVC conduit along with 1x 2.5 mm copper wire for loop earthing required |
| 157 | Wiring for power plug with 2 x 4 sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked PVC conduit along with 1x4.0 Sq mm copper wire for loop earthing as required |
| 158 | Wiring for power plug with 2 x 1.5sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked PVC conduit along with 1x1.5 Sq mm copper wire for loop earthing as required |
| 159 | Wiring for 1x 1.5sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked in the existing PVC conduit etc. as required ( Invertor wiring ) |
| 160 | Wiring for sub main wiring with following sizes of PVC/ insulated copper conductor wires in the surface/ recessed PVC / MS conduit along with PVC insulated copper conductor earth wire as required complete with connections, testing and commissioning etc. as per specifications and drawings. |
| 161 | 2x6 sq mm with 1x6.0sqmm earth wire |
| 162 | Wiring for sub main wiring with4x10 sqmm alongwith 2x6sqmm earth wire sizes of PVC/ insulated copper conductor side core conductor in surface/recessed PVC conduit etc. as reqd. |
| 163 | Wiring for twin control light point with 2x1.5 sq. mm PVC insulated copper conductor cable in surface / recessed ISI marked PVC conduit with 2 way 6 Amp switch |
| 164 | Supplying and fixing suitable GI box with modular plate and cover in front on surface or in recess, including P/F 6 pin 15/16 amp and 5/6 amp modular socket outlet and 15/16 amp modular switch , connection testing etc as requried |
| 165 | Supplying and fixing of wall fan 400 mm sweep heavy duty with including connection, texting etc. as required. |
| 166 | Supply and fixing of 25 mm dia PVC conduit alongwith accessories in surface/recess. |
| 167 | Supply and fixing of 32 mm dia PVC conduit alongwith accessories in surface/recess. |
| 168 | Supply and fixing 20 Amp Industrial socket with 32 Amp SPN including connection, testing, etc. as required |
| 169 | Supply installation testing commissioning of 2.0 ton capacity split AC 5 star with high flow (20 meter flow range) complete with indoor and outdoor units including extra copper pipe with insulation, wall stand and 5 KVA voltage stablizer (range 90-270v) complete job Please Enable Macros to View BoQ information |