| 1 | Supply , installation testing and commissioning of energy saving LED lamps as approved or Havells/ C&G/ Philips/ Halonix/eqvi.make 12 Watt |
| 2 | 15 Watt |
| 3 | 30 Watt |
| 4 | Supply fixing testing and comm. LED batten ( tube light) 10-18W complete with tube. |
| 5 | Supply fixing testing and comm. Of MCB's Legrands,Havels/ Schenieder/Hager/Crabtree /ABB 6-40 amp. SP MCB |
| 6 | 40-63 amp. DP,MCB |
| 7 | 40-63 amp TPN MCB |
| 8 | Supply fixingtestingandcomm.OfMCCB'sLegrand/Havels/ Schenieder/Hager/Crabtree/ABB 63-100 amp 4 pole 25 K |
| 9 | 160 amp 4 pole 36 K |
| 10 | 250 amp 4 pole 36 K |
| 11 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm,1100V, FR, PVC insulated M.Std copper conductor ( Havel/polycab / parflex or of approved make) single core cable to be laid in all/any type surface / recessed/grooved with standard class PVC conduit ( Anchor/ Alba make), with modular switch ( havels /legrands or as approved, make), modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 12 | Wiring for light duty power plug/sockets with 2X4 sq. mm FRLS PVC insulated copper conductor ( Havell/poly cab /Paraflex/ Eq. make as approved) single core cable in surface/recessed medium class PVC conduit 25mmdia ( Anchor/ Alba make), alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 13 | Supplying and fixing of following sizes of medium class PVC conduit ( Anchor/ Alba/ Eq. make)along with accessories in surface/recess including cutting the surfaces/wall of all types and making good the same in case of recessed conduit as required. 25-32 mm dia-1.6mm thick |
| 14 | S/F testing and comm.of PVC insulated multistranded copper 1100 V ,FRLSH wires, Havell/Polcab/Paraflex/Equivalent make as approved. 0.75-1mm sq |
| 15 | 1.5 mm sq |
| 16 | 2.5 mm sq |
| 17 | 4 mm sq |
| 18 | 6 mm sq |
| 19 | 10 mm sq |
| 20 | 16 sq mm |
| 21 | Supply fixing testing and comm.of 16 /20amp switch Havells/philips/ABB /Anchor make or as approved. |
| 22 | Supply fixing testing and comm.of 16 /20amp socket Havells/philips/ABB /Anchor make.or as approved. |
| 23 | Supply fixing testing and comm.of 6/10 amp switch Havells/philips/ ABB /Anchor make.or as approved. |
| 24 | Supply fixing testing and comm.of 6/10 amp 3/2 pin socket Havells/philips/ABB /Anchor make or as approved.. |
| 25 | Providing and fitting of 16/20 amp SS combine Legdands/Havels/ABB / Anchor make or as approved.. |
| 26 | Providing and fittting of 6 amp 3 pin top Havells/philips/ ABB /anchor make or as approved. |
| 27 | Supply fixing testing and comm. Of backlite holder /batten holder/angle holder/ceiling rose Havells/philips/ABB /Anchor make incl. PVC Block.or as approved |
| 28 | S/F/T/C of 2 KW 250 Volt heating element for geyser |
| 29 | S/F/T/C of 250 Volt thermostat for geyser . |
| 30 | S/F/ T/C of heat convectors fitted 2x1000 watt with top 16 A-3pin, Bajaj/warmex/Standard make.or as approved. |
| 31 | Providing and fixing of 48\\" sweep ceiling fan Usha/Havels/ make with iron hook or as approved.. |
| 32 | Providing and fixing of wall fan Usha/Havell make. |
| 33 | Replacement of Electrolyte in invertor battery and charging |
| 34 | S/F/T/C of 200-300mm Exhaust Fan USHA/ Havell/crompton or Standard make.as approved. |
| 35 | Supply fixing testing and comm.of 10 watt LED Bulk Head philips/Havell Halonix/make or as approved. |
| 36 | S/L,testing and commissioning of PVC alluminium armoured cable 11000 volt grade PVC insulated Havell/polycab/Equi. standard make.10 sq.mm 4 core |
| 37 | b) 16 sq.mm 4 core |
| 38 | d) 25 sq. mm 3.5 core |
| 39 | d) 35 sq. mm 3.5 core |
| 40 | e) 50 sq. mm 3.5 core |
| 41 | f) 70 sq. mm 3.5 core |
| 42 | g)90 sq mm 3.5 core |
| 43 | h) 120 sq mm 3.5 core |
| 44 | i) 185 sq mm 3.5 core |
| 45 | Earth work excavation 70% hard rock and 30 % soft soil for cable trench, 2 ft deep with an average breadth of 1.5ft including refilling of trench with excavated earth after laying of cable/pipes and ramming it properly excluding cost of cable.the job also includes laying of warning tape and sand layer below and above the cable. |
| 46 | Supply fixing testing and comm.of automatic voltage stabilizer 1-phaseof following capacities Alba/Electricfield/ Cosco as approved. a) 1 KVA |
| 47 | b) 2 KVA |
| 48 | c) 3 KVA |
| 49 | d) 5 KVA |
| 50 | Supply installation testing and comm.of 16/20 amp power extension box ( 1 No. 6 amp switch, -1 No. 20amp switch,- 3 Nos. 6 amp multipin socket and- 1 No.6/16 Socket) with suitable size lead and top. C&S make. |
| 51 | Providing and fixing of Hylum Sheet |
| 52 | S/I/T/C of AC/DC Electronic Bell complete standard make. |
| 53 | Supply installation testing and commissioning of chordless Bell with 2 no battery,standard make |
| 54 | Supply of Trasformer oil oil for DTR/AVR/STABLISERS |
| 55 | Supply of Deisel oil for running of Generator. |
| 56 | Providing and fixing of Al.thimble 10-35mm sq. |
| 57 | Supply fixing testing and comm.of baklite/porcelene, cable connector 40-63 amp.Legrands/Havells/polycab/or as approved |
| 58 | Supply, laying overhead, testing and comm. Of 16mm -2 core- 650/1100V grade unarmoured Aluminium cable Havell/Polycab/Eq. standard make. |
| 59 | Supply installation testing and comm, of control pannel prewired of sheet stee1.6 mm thick 2'x2'x1 deep' powder coated phosphatised designed having angle 4' height iron stand fitted with following accessories to be grouted in the cement concrete,complete job, a)panel as per given dimensions/specifications. |
| 60 | b)200 amp 4 strip bus set |
| 61 | c) Analog type A/V meters set/indicators 3 set |
| 62 | Supply fixing testing and comm.of globe/fency decorative unbreakable luminaries 6-9inch Height,8\\"-10\\" dia Havels/philips standard make as approved complete with 15 Watt warm/cool LED lamp Havell/philips/Halonix make. |
| 63 | Supply installation testing and comm. of new gen.Street lighting luminaire 150 Watt,15000-17500 lumen LED type. new gen, environmental friendly long life versatile pressure die-cast aluminium- IP66- with high power LED as light source Havells/Philips/Halonix/Standard make as approved. |
| 64 | Supply installation testing and comm. of new gen.Street lighting luminaire 120 Watt,15000-17500 lumen LED type. new gen, environmental friendly long life versatile pressure die-cast aluminium IP66 with high power LED as light source Havells/Philips/Havells/ Halonix/Standard make as approved. |
| 65 | Supply installation testing and comm. of Street lighting luminaire 60-80Watt LED type, >6000-8000 lumens environmental friendly, long life ,versatile ,pressure die-cast aluminium, IP66 , with high power LED as light source Havell/Philips/Halonix/ Eq. Standard make or as approved |
| 66 | Supply installation testing and comm. of die cast aluminium IP66 flood light 150 W with high power LED's as light source anchor /in built powe supply unit Philips/ Havells/Halonix/Eq. Standard make or as approved |
| 67 | Supply installation testing and comm. of die cast aluminium IP66 flood light 50-60 W with high power LED's as light source >6000 lumens Street lighting luminaire. Philips/ Havells/ HalonixEq. Standard make |
| 68 | S/F testing and comm. Of recessed/ surface mounted ceiling 12-15 Watt LED down lighters commercial series philips / Havell( Pluto pannel)/Halonix equivalent standard make. |
| 69 | Supply and fixing of 0ne way arm bracket for mounting the luminaire on the top of the pole/ with the wall etc fabricated out of 0.9mtr long, 50/40mm diameter GI . pipe, along with GI SOCKET with dia equal to pole top ouerdia,gasset plate 3-4 mm thick , clips, nuts and bolts for holding the luminarie. |
| 70 | Supply installation testing and comm.of invertor battery 180 -200AH/12 V Exide invatubular/ Su-kam /Luminous make including battery trollies carriage complete job |
| 71 | Supply installation testing and comm.of hybrid/duo inverter of following rating Microtek/Sukam/Luminous make. ( strictly as per approved sample).a)800 - 1100 VA. |
| 72 | b)1400-1600 VA |
| 73 | c)1800-2000 VA |
| 74 | Supply installation testing and comm. of Street lighting luminaire 35-45Watt LED >3500-4500 lumens, environmental friendly long life versatile pressure die-cast aluminium IP66 with high power LED as light source Havells( Endurra Cityliner NEO)/Philips/Halonix/Eq. Standard make. |
| 75 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. |
| 76 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 77 | Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required. |
| 78 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.a)4 X 16 sq.mm (set.) |
| 79 | b)3½ X 35 sq.mm (set) |
| 80 | Erection of metallic pole 8.0 to 11.0 metre including cost of ..P/L of cement concrete in 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation including excavation of pit of 1/6th of pole length ,form work for proper shape and refilling etc. complete job/ as reqd |
| 81 | Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required |
| 82 | Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels. |
| 83 | Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels. |
| 84 | Supply and errection of 8.0 mt long(410SP-14) steel tubular poles, sawaged type conforming to IS-2713, (Part-II) ,planting depth 1.5 mt .Pole shall have 2 no bolts welded at a distance of 3 mt. from bottom of pole and suitable holes shall be drilled in pole for service connection and for luminaryand earth wires. |
| 85 | Painting of pole with one coat of red oxide and two coats of Al. paint 0r as apprved for 8-11 mtr long poles |
| 86 | Supply and errection incl. carriages of 9.0 mt long(410SP-33) steel tubular poles, sawaged type conforming to IS-2713, (Part-II) ,planting depth 1.5 mt .Pole shall have 2 no bolts or GI clamp welded at a distance of 3 mt. from bottom of pole and suitable holes shall be drilled in pole for service connection and lum. earth wires. |
| 87 | Supply installation testing and comm.of prodigy meter with kiosk of class 1.0 accuracy class , static 3 phase-4wire, tri -vector Prodigy energy meter , having current range 40-200 A of latest version with P/F of suitable size of kiosk/enlosure Secure/L&T/ or as approved equivalent make. The meter shall be suitable for measurement of energy and power , demand requirement in an AC balanced/unbalanced system over a power factor range of zero lag to unity. these meters should have additional communication port for wireless remote meter reading. ( complete job) |
| 88 | S/F/T/C of three phase 4 wire energy meter 100 amp Secure/L&T/equivalent make Or as approved and a kiosk of suitable size to house energy meter. The kiosk is to be fitted on the pole/wall with the help of clamps. .Complete job. |
| 89 | S/F/T/C of single phase 2 wire, energy meter 60-100 amp Secure/equivalent make and kiosk /box of suitable size to house energy meter. The kiosk is to be fitted on the pole/wall OR grouting in conc. with the help of angla iron legs clamps./bolts stud type .Complete job. |
| 90 | Supply laying , testing and commissioning of PVC sheathed alluminium cable un-armoured 1100 volt grade Al. cable Havel/Eq. approved standard make..the job also includes the end termination of cables by suitable size lugs and connecting the same with the main line.a)35 sq. mm single core |
| 91 | b)50 sq. mm single core |
| 92 | c)70 sq. mm single core |
| 93 | d)95 sq. mm single core |
| 94 | P/L of HDPE -WD PIPE 40-50 mmdia |
| 95 | P/F Alu. wound LT Booster/Main coil FOR 30-20 kva AVR |
| 96 | P/F copper wound tuner coil with brush set and holding bar 40-60 AMPS |
| 97 | P/F Digital cut plate double display with wiring set,plug in/out sockets for AVRs 40-60 amps Including cutting , welding,connecting, make as of approved sample/quality. |
| 98 | P/F contactors 4 pole-40-60amps Legrand/havel/l&t make |
| 99 | P/F of astronomical timer switch of approved sample / quality Legrand/havel/l&t make |
| 100 | P/F double or single cut relay 32-40-50 amps of approved sample / quality Legrand/havel/l&t make |
| 101 | P/F digital voltmeter /amperemetr 0-440V/0-150A of approved sample /quality Legrand/Philips/havel/l&t make |
| 102 | P/F/binding/connecting through 1.5 mm wire,LED tape/strip rain/water/frost proof having 20 to 32 leds per meter ,connecting through 1.5 mm wire, with pin adopter/tape waterproof /pins ,nails, rope,screws,,of approved sample/quality oppel/havel/philips make |
| 103 | P/F of electronic driver for 120/150 watt flood lights of 0.35-0.70 Amps. 120V-270V GL Prog sXt Or as approved philips/havels/LnT |
| 104 | Supply,Fabrication,drilling,welding and assembling the steel structure inclu grouting /fixing in M15 2' deep 1'x1' square, shape and painting with anti corrosive metal primer and metal paint of approved shade with 2 coats each |
| 105 | P/F revisable sync motor 5-10kg-mtr torque Havel/ Crompton/Fisher or as per approved sample. |
| 106 | Providing/supply of electricians 1- Grade |
| 107 | Providing/supply of electricians 1- Grade |
| 108 | Supply , Installation ,testing and commissioning of Change over switch of isi marked make incl making of necessary connections. |
| 109 | 32-40 Amps DP type Change over switch |
| 110 | 63 Amps DP Change over switch |
| 111 | 63 Amps TPN Change over switch with sheet steel enclosure |
| 112 | 100 Amps TPN Change over switch with sheet steel enclosure |
| 113 | 200 Amps TPN Change over switch with sheet steel enclosure |
| 114 | 400 Amps TPN Change over switch with sheet enclosure |
| 115 | Supply , Installation ,testing and commissioning of Bus Bar Chambers to be fitted on Walls /floors complete Job including making of necessary connections etc |
| 116 | 63 Amps TPN Aluminium Bus Bar Chamber |
| 117 | 100 Amp TPN Aluminium Bus Bar Chamber |
| 118 | 200 Amps TPN Aluminium Bus Bar Chamber |
| 119 | 400 Amps Aluminium Bus Bar Chamber |
| 120 | 630 Amps Aluminium Bus Bar Chamber |
| 121 | Supply ,installation ,testing and commissioning of Cable termination Kit (Heat Shrink type ) |
| 122 | Supply ,Installation ,testing and commissioning of following size thimbles dully crimped with hydraulic tool,including making of necessary connections |
| 123 | 630-800 Sq.mm Aluminium thimbles |
| 124 | 300-400 sq.mm Aluminium thimbles |
| 125 | 185-240 Sq.mm Aluminium thimbles |
| 126 | 95-120 sq.mm Aluminium thimbles |
| 127 | 50-70 Sq.mm Aluminium thimbles |
| 128 | 25-35 sq.mm Aluminium thimbles |
| 129 | 6-10 Sq.mm Copper thimbles |
| 130 | 25-35 Sq.mm Copper thimbles |
| 131 | 50-70 Sq.mm Copper thimbles |
| 132 | Hire Charges for Supply,Laying and Connecting of Decorative Electric Jallaries ,including laying of electric cables for providing power supply from LT panels,The Job Further includes Watch & Ward of Materials and removing of same after the due date of completion.The job also includes to & fro carriage of materials upto site of work |
| 133 | Day-1st |
| 134 | Day-2nd and onwards |
| 135 | Supply ,installation ,testing and Commissioning of Outdoor type multi Colour LED Strip with alled accessories adoptor ,chockes etc complete job. |
| 136 | Supply and fixing of 9-10 Watts LED Surface/recess mounted lighting fixtures of having Aluminium body of Philps / Havells/Halonix makes dully isi marked ,incl making of necessary connection |
| 137 | Supply and fixing of 12-15 Watts LED Surface/recess mounted lighting fixtures of having Aluminium body of Philps /Havells/Halonix makes dully isi marked ,incl making of necessary connection |
| 138 | Supply ,Installation,Testing and Commissioning of decorative type Glow mac fitting made of unbreakable polycarbonate of following size ,including cost of providing and fixing of LED Lamps of standard make dully ISI Marked |
| 139 | Glow mac fitting suitable for housing of 9-12 Watts LED Lamps |
| 140 | Glow mac fitting suitable for housing of 23 Watts LED Lamps |
| 141 | Glow mac fitting suitable for housing of 36 Watts LED Lamps |
| 142 | Glow mac fitting suitable for housing of 50 Watts LED Lamps |
| 143 | Supply ,Installation,Testing and Commissioning of decorative LED Wall brackets |
| 144 | 10-12 Watts |
| 145 | 15-20 Watts |
| 146 | Supply ,Installation,Testing and Commissioning Bollard of new Generation saving enviromental friendly long life Aesthetically designed aluminium Lands caps IP65 Luminary for diffused lighting with higher power as light source (Cone LED Bollard) of havells/Halonix make or any other equivalent make |
| 147 | Supply ,Installation,Testing and Commissioning of 6-9 Wtts LED Bulk head fittings |
| 148 | Supply ,Installation,Testing and Commissioning of New generation post to energy saving enviromental friendly long life aesthetically designed with symmetrical light distribution ,Spun Aluminium Lands cape luminary with high power LED's as light source of Havells /Halonix/phillipsEq.make |
| 149 | Supply and fixing of PVC Trolley suitable for housing batteries |
| 150 | For Housing of Single Battery |
| 151 | for Housing of Two Battery |
| 152 | Supply, Installation, Testing and commissioning of Servo Voltage stabilizers having all inbuilt protections like Over voltage, under voltage & Overloading with TDR.The Stabilizer shall be servo-controlled automatic ,ONAN cooled and provided with first filling of fresh filtered transformer oil having required dielectric strength (Operating from AC input voltage from 90-260 Volts incase Single and 155 Volts to 460 Volts in case three phase) of Casco /Alba /Servokon Make |
| 153 | 20 KVA (3-Phase IN ,3-Phase Out) |
| 154 | 30 KVA (3-Phase IN ,3-Phase Out) |
| 155 | Wet servicing of AC's (1 Ton/1.5Ton/2 Ton) |
| 156 | Dry servicing of AC's (1 Ton/1.5Ton/2 Ton) |
| 157 | Servicing and gas filling of AC's (1 Ton/1.5Ton/2 Ton) |
| 158 | Supply ,installation of PC Card of 2 Ton AC of LG/IFB/Panasonic/Diakin make for replacement of damaged PC Card |
| 159 | Supply ,installation of Compressor for 1.5/2 Ton AC of LG/IFB/Panasonic /Diakin make for replacement of damaged compressors |
| 160 | Providing and fitting of 6mm and 10 mm Copper tubes along with insulation |
| 161 | Dismentling of AC's from existing position including lowering down of indoor and outdoor units with allied copper pipings and reinstallation of same to new location ,including servicing and gas filling ,testing and commissioning complete job. |
| 162 | Dismentling of AC's from existing position including lowering down of indoor and outdoor units with allied copper pipings stacking of same and handing over to intending department |
| 163 | Supply,Installation,Testing & Commissioning of D.C Invertor Techonology Hot and Cold Air Conditioner of ogeneral/mitshubi/eq make .The job further includes providing and fitting of indoor unit on wall by employing suitable clamps and outdoor units on angle iron Stand for holding of out door unit fitted with nuts and bolts,laying of refrigerant copper piping upto 3 mtrs, whereever needed,insulating the copper pipeline with nitrilic foam ,topping up with refrigerant for additional length of piping etc.complete. The job also includes p/f of pvc flexible drain pipe of length 12 mts alongwith fittings.The job further encompasses carrying out repairs to walls whereever the same are cut.The job includes AMC of AC for a period of two years from date of sucessfull commissioning . |
| 164 | 1.5 Ton |
| 165 | 2 Ton |
| 166 | Supply,Installation,Testing & Commissioning of BEE 4-Star rating Hot and Cold Air Conditioner of Toshiba / O general/Mitsubhushie make .The job further includes providing and fitting of indoor unit on wall by employing suitable clamps and outdoor units on angle iron Stand for holding of out door unit fitted with nuts and bolts,laying of refrigerant copper piping upto 3 mtrs, whereever needed,insulating the copper pipeline with nitrilic foam ,topping up with refrigerant for additional length of piping etc.complete. The job also includes p/f of pvc flexible drain pipe of length 12 mts alongwith fittings.The job further encompasses carrying out repairs to walls whereever the same are cut.The job includes AMC of AC for a period of two years from date of sucessfull commissioning . |
| 167 | 1.5 Ton |
| 168 | 2 Ton |
| 169 | Supply ,Installation ,testing and commision of relay voltage stabilizer (Alumium Wound ) operating from AC input voltage from 90-260 Volts thereby Producing 230 +-3 output voltage |
| 170 | 4 KVA Please Enable Macros to View BoQ information |