| 1 | 33/11kV, 6.3 MVA ,ONAN, Copper wound, Out-door Type, conventional Power Transformer, Oil Filled with OLTC and all accessories including HT and LT Terminal connections |
| 2 | SUB STATION MAIN EQUIPMENTS |
| 3 | 33 kV VCB (36 kV, 2000A, 26.2 kA, Outdoor Type) |
| 4 | 33kV C&R Panel for Transformer BAY Simplex/duplex as per requirement completely wired including Sub Staion Automation Supporting IEDS/ Numerical Relays of Make ABB/Seimens/GE/MICOM/ALSTOM/Schneider with IEC 61850 Compatibility with Differetial Relay, O/C and E/F Protection ( Tri-vector meter -5 Amps , DLMS Compliant with RS-485 port |
| 5 | 33 kV Isolator with Earthing Blade (36kV,1250A, Outdoor, 3 poles, 25 kA) |
| 6 | 33 kV Isolator without Earthing Blade (36KV,1250A, Outdoor, 3 poles, 25 KA) |
| 7 | 33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ) |
| 8 | 30 kV Lightening Arrestors (30 kV, 10kA, Station class, ZnO, Polymer) gap less |
| 9 | 33KV Voltage Transformer |
| 10 | 33 kV Solid Core Post Insulator 36kV, 235kV Impulse |
| 11 | Structures |
| 12 | Galvanised Steel Structures |
| 13 | Galvanised Nuts & Bolts |
| 14 | Control Cables |
| 15 | CONTROL CABLE 2 CORE, 2.5MM2 , COPPER ARMOURED 1.1 KV GRADE |
| 16 | CONTROL CABLE 5 CORE 2.5MM2 , COPPER ARMOURED 1.1 KV GRADE |
| 17 | CONTROL CABLE 8 CORE 2.5MM2 , COPPER ARMOURED 1.1 KV GRADE |
| 18 | 12 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. |
| 19 | 4 Core 6 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. |
| 20 | Lugs, Ferrules etc. |
| 21 | CONDUCTOR & HARDWARE |
| 22 | 200 mm² ACSR Conductor |
| 23 | T Clamps |
| 24 | Single Suspension Fitting |
| 25 | Single Tension Fittings |
| 26 | Polymeric composite Disc Insulator 70 KN, Suitable for 36 KV |
| 27 | CT CLAMP CONNECTORS |
| 28 | CONDUCTOR CLAMPS FOR SURGE ARRESTOR |
| 29 | BI METTALIC ISOLATOR PAD CLAMPS FOR CONDUCTOR |
| 30 | VCB PAD CLAMPS |
| 31 | PG CLAMPS SUITABLE FOR 0..2 ACSR |
| 32 | BUS POST INSULATOR CLAMPS |
| 33 | 11 KV POWER CABLES 400 MM2, 1 CORE XLPE, ARMOURED CABLE / CABLE FRLS TYPE (For Transformer I/Cs) |
| 34 | GI Flat for Earthmat 50x6mm |
| 35 | MS EARTHING SPIKES 3 METER LONG 20 MM DIA (30 Nos) |
| 36 | Bay Marshalling Kiosk, made of 2.5 mm. thick sheet steel, protection class IP 55 complete with 200 TB |
| 37 | GI Strip 25x6mm For Gantry Structure / Beam / Earthing Equipments |
| 38 | Earthing of Transformers / LA |
| 39 | 11 kV VCB Panel Board (12 kV, 1250A, 25 kA, Outdoor) with O/C, E/F relays (IEC61850), Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port |
| 40 | 6.3 MVA (1+5) |
| 41 | 11kV, Gapless Surge Arrestor,9 kV ,10 kA ,LA with Polymer housing, Stn. Type (8/10 Sets) |
| 42 | 11 kV XPLE Power Cables- |
| 43 | 11 kV 400 mm² 3 Core XLPE Cable armoured, FRLS |
| 44 | 11kV 3 Core XLPE 185 mm² Round Wire Armoured, FRLS from Control Room to feeding gantry |
| 45 | 11 kV Indoor Heat Shrinkable Cable Termination Kit for 3 Core 400 mm2 Cables |
| 46 | 11 kV Indoor Heat Shrinkable Cable Termination Kit for 3 Core 185 mm2 Cables |
| 47 | 11 kV Outdoor Heat Shrinkable Cable Termination Kit for 3 Core 400 mm2 Cables |
| 48 | 11 kV Outdoor Heat Shrinkable Cable Termination Kit for 3 Core 185 mm2 Cables |
| 49 | 11 kV Isolator, double break,3-pole, 600Amp, horizental mounting Type, with Earth Switch. |
| 50 | 11 Mtr. Long Pole |
| 51 | 11kV HG , Fuse Switch 3-Phase |
| 52 | Galvanised iron of sorts |
| 53 | 100 kVA,11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound) |
| 54 | 120 mm² PVC LT Cable 4 Core, armoured, FRLS |
| 55 | Cement bottoming 1:2:4 mix as per REC standards 0.5cum per pole |
| 56 | Earthing of 100kVA substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 75 mm x10 mm & 50 mm x 6 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 57 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 3 mtr long through GI strip |
| 58 | ACSR 50mm2 |
| 59 | 11 KV Pin Insulator |
| 60 | Disc Insulator Complete |
| 61 | Anti Climbing Devices |
| 62 | BATTERY BANK FOR 30 VOLTS DC /100AH of 15 Number Cell of 2Volt each /SEALED MAINTENANCE FREE/VRLA TYPE 30V 100 ah Float cum Boost Charger |
| 63 | AC DISTRIBUTION BOARD |
| 64 | DC 30 Volt DISTRIBUTION BOARD |
| 65 | Fire Fighting Equipments |
| 66 | FE CO2 4.5 Kg capacity, Wall mounted |
| 67 | Fire Buckets |
| 68 | Rubber mats |
| 69 | Helmet |
| 70 | Rubber Gloves for 33 kV level |
| 71 | Rubber Gloves for 11kV level |
| 72 | Safety Belt |
| 73 | Safety Shoes |
| 74 | Earthing rod (set of 3 rods) |
| 75 | HV Detectors all voltages |
| 76 | Solar Plant 20KW |
| 77 | 12KV capacitor bank with VCB Panel with complete arrangements for connection with 11KV incommer Panel , series reactor , isolator , RVT, Surge Arrestor , HT cable , with termination Kit , CRCA Cubical panel with structure foundation and accessories |
| 78 | Supply installation testing commissioning 16 meter highmast light suitable for 9 lantern systmetrically fitted alongwith their control gear with electrically operated motor system and having two point suspension system with stainless steel wire rope of 6 mm dia 97/19 guage and double drum winch with luminaries mounting arm,pully assemblyTrailing cable 2.5 x 4 core manual handle junction box lightening finial compensating disc (top-150, bottom dia 360 mm) sheet thickness 4 mm/3 mm with base plate 7750 x 25 mm foundation bolts M 30 x 1000 long 12 nos J type menufactured from special steel along with nuts washers anchor plates and templates with 6 arm ringsviation obstruction light lightening arrestor spike including necessary excavation and RCC foundation as per height complete all as specified and as directed including 150 watt lights 9 nos |
| 79 | Earth work in filling in plinth, under floors, and yard area with borrowed earth including royalty and carriage by mechanical transport up to any lead. Earth shall be spread in layers not exceeding 20cm in depth, each layer being properly watered and consolidated by ramming/rolling to achieve minimum 95% MDD, including removal of all vegetation and dressing of finished surfaces complete as per PWD specifications. |
| 80 | Construction of Compound Wall : Detailed work including Earthwork in excavation in all kinds of soil for foundation trenches; providing and laying 150mm thick Lean Concrete of M5 grade (1:5:10) in foundation (width 900mm);Providing and laying M10 grade (1:3:6) cement concrete in two steps with 750 mm width and 750 mm depth of 1st step & 450 mm width and 900 mm depth of 2nd step: providing 230mm thick Brick Work of height 1.8m in cement mortar (1:6) for the main wall; providing R.C.C. (M20) tie beam of size 300 x 300mm with 6 No. 12mm dia bars and 8mm stirrups @150 mm c/c at plinth and level for structural stability; 12mm thick cement plastering (1:4) on both sides; 50mm thick PCC (1:2:4) coping with rounded edges; and finishing with two or more coats of weather-proof exterior grade paint over a coat of primer, including all labor, scaffolding and materials complete. |
| 81 | Providing and fixing G.I. Chain-link Fencing of 1.8M (6ft) height using 8 SWG (4mm) dia wire with mesh size 50x50mm. Fencing shall be supported by ISA 50x50x6mm angle iron posts spaced at 1.8m centers, embedded in M15 grade concrete in two steps with 600mm depth and 600mm width of 1st step & 300mm width and 600mm width of 2nd step; M15 grade conrete top be laid on 150mm thick lean concrete of M5 grade including excavtion and shuttering etc. complete. The fencing fabric shall be securely stretched and fixed to the posts using 40x5mm MS Flat patti runners along with ISA 50x50x6mm angle iron at top and bottom and vertical supports, including two rows of G.I. barbed wire at the top and painting of all steel members with anti-corrosive primer and synthetic enamel paint. |
| 82 | Providing and laying HDPE Pipe of Outer Dia 180mm and Inner Dia 152mm (PN-6 rating) for 11kV XLPE Cable protection. Pipes shall be laid in trenches at a minimum depth of 1.0M below ground level, including excavation, 100mm sand cushioning, jointing of pipes, and backfilling with selected earth in layers complete as per technical requirements. |
| 83 | Construction of RCC Foundation for 33/11kV Power Transformer as per structural design. Item includes Earthwork excavation, 150mm PCC (1:4:8) base, providing and laying M20 grade Reinforcement Cement Concrete (1:1.5:3) using 20mm graded stone aggregate, providing and placing Fe500 TMT reinforcement bars, shuttering, and finishing of exposed surfaces, including curing and fixing of anchor bolts. |
| 84 | Construction of Equipment and Gantry Foundations for 33kV switchyard. Includes all earthwork, PCC (1:4:8) sub-base, M20 grade RCC for footings and pedestals, providing and tying Fe500 reinforcement, formwork, and precise fixing of foundation bolts using templates to ensure gantry alignment, including finishing and backfilling. |
| 85 | Providing and laying 33kV Yard Metalling/Concreting works. Includes site clearing, spreading and compacting a 100mm thick base layer of 40mm nominal size stone metal/boulders, and surfacing with M15 grade PCC or cement grouting as per standard utility yard specifications to ensure proper drainage and weed suppression. |
| 86 | Construction of Control Room Building (111 sqm plinth area) as per approved drawings. Works include RCC framed structure using M20 grade concrete; 230mm thick brick masonry for all internal as well as external walls in CM (1:6); 150mm thick RCC roof slab with necessary waterproofing treatment; vitrified tile flooring in main area; providing and fixing ceramic floor and wall tiles for bathroom/toilet area; internal and external plastering (1:4); painting; providing and fixing steel doors and aluminum windows; and internal electrification/sanitary works complete. |
| 87 | Development of site and landscaping: Includes removal of wild vegetation and debris, leveling and dressing of ground to proper slopes, ornamental landscaping with plantation of trees/shrubs in unbuilt areas, and construction of internal WBM/CC roads with associated surface drains for storm water management. |
| 88 | Design, supply, and installation of Yard Lighting System. Includes providing 8.0 meter high Octagonal steel poles, LED flood light fixtures (minimum 120W), internal wiring, switchgear/control panel, earthing of poles, and necessary foundations complete for illumination of the yard area. |
| 89 | Construction of Cable Trenches of required widths. Work includes excavation, providing 150mm thick RCC (M20) or Brick masonry walls, 100mm PCC base, internal plastering with water-proofing compound, and providing 6mm thick MS Chequered plate covers or pre-cast RCC covers with lifting hooks complete. |
| 90 | Note:-Buy back of old existing 33/11kV, 6.3 MVA ,ONAN, Copper wound, Out-door Type, conventional Power Transformer, Oil Filled transformer (Reserve Price=Rs 12,00,000/- shall be deducted from the total amount quoted by the bidder) Please Enable Macros to View BoQ information |