| 1 | Safe Loading carriage including unloading & proper stacking of following store materials from from any store of MVVNL to site. (33/11 KV Sub-station Sahaba Distt-Bahraich) |
| 2 | 33 KV VCB 800A, 750 MVA |
| 3 | 33 KV Control Panel for Single T/F |
| 4 | C.T. O/D 33 KV CTR 200/100/1-1A |
| 5 | 11 KV Incoming switch gear 600/300/5A |
| 6 | 11KV 3 Core cable 3x300mm XLPE |
| 7 | 33KV Bus Isolator |
| 8 | 33KV Lightening Arrestor |
| 9 | 33 KV Fuse Set |
| 10 | 90lbs rail Pcs for T/F (44.64Kg/m) |
| 11 | ACSR Dog Conductor |
| 12 | 11KV cable jointing kit indoor 3x300sq.mm XLPE |
| 13 | 11KV cable jointing kit outdoor 3x300sq.mm XLPE |
| 14 | Steel Sections(M.S Channel, M.S. Angle, 32 mm Round Bar etc) |
| 15 | 11 KV 3 Core cable 3x120mm XLPE |
| 16 | 11KV cable jointing kit indoor 3x120sq.mm XLPE |
| 17 | 11KV cable jointing kit outdoor 3x120sq.mm XLPE |
| 18 | 11 KV Outgoing swithgear 200/100/5 Amp. 350MVA |
| 19 | 8.5 M long PCC pole |
| 20 | M.S. Angle Iron 65x65x6mm Bracing with 4 clamp |
| 21 | Top Channel 100x50mm with clamps 2240 mm. long |
| 22 | 11 KV Disc. Insulator Polymeric |
| 23 | 11 KV Disc fitting |
| 24 | 11 KV Pin Insulators Polymeric |
| 25 | Stay Set Complete |
| 26 | Earthing of Pole by MS earthing Rod |
| 27 | Safe Loading carriage including unloading & proper stacking of following store materials from from any store of MVVNL to site.(33/11 KV Sub-station Newada Mod Distt-Bahraich) |
| 28 | 33 KV VCB 800A, 750 MVA |
| 29 | 33 KV Control Panel for Single T/F |
| 30 | C.T. O/D 33 KV CTR 200/100/1-1A |
| 31 | 11 KV Incoming switch gear 600/300/5A |
| 32 | 11KV 3 Core cable 3x300mm XLPE |
| 33 | 33KV Bus Isolator |
| 34 | 33KV Lightening Arrestor |
| 35 | 33 KV Fuse Set |
| 36 | 90lbs rail Pcs for T/F (44.64Kg/m) |
| 37 | ACSR Dog Conductor |
| 38 | 11KV cable jointing kit indoor 3x300sq.mm XLPE |
| 39 | 11KV cable jointing kit outdoor 3x300sq.mm XLPE |
| 40 | Steel Sections(M.S Channel, M.S. Angle, 32 mm Round Bar etc) |
| 41 | 11 KV 3 Core cable 3x120mm XLPE |
| 42 | 11KV cable jointing kit indoor 3x120sq.mm XLPE |
| 43 | 11KV cable jointing kit outdoor 3x120sq.mm XLPE |
| 44 | 11 KV Outgoing swithgear 200/100/5 Amp. 350MVA |
| 45 | 8.5 M long PCC pole |
| 46 | M.S. Angle Iron 65x65x6mm Bracing with 4 clamp |
| 47 | Top Channel 100x50mm with clamps 2240 mm. long |
| 48 | 11 KV Disc. Insulator Polymeric |
| 49 | 11 KV Disc fitting |
| 50 | 11 KV Pin Insulators Polymeric |
| 51 | Stay Set Complete |
| 52 | Earthing of Pole by MS earthing Rod |
| 53 | Safe Loading carriage including unloading & proper stacking of following store materials from any store of MVVNL to site. (33/11 KV Sub-station Risia(Urban) Distt-Bahraich) |
| 54 | 33 KV VCB 800A, 750 MVA |
| 55 | 33 KV Control Panel for Single T/F |
| 56 | C.T. O/D 33 KV CTR 200/100/1-1A |
| 57 | 11 KV Incoming switch gear 600/300/5A |
| 58 | 11KV 3 Core cable 3x300mm XLPE |
| 59 | 33KV Bus Isolator |
| 60 | 33KV Lightening Arrestor |
| 61 | 33 KV Fuse Set |
| 62 | 90lbs rail Pcs for T/F (44.64Kg/m) |
| 63 | ACSR Dog Conductor |
| 64 | 11KV cable jointing kit indoor 3x300sq.mm XLPE |
| 65 | 11KV cable jointing kit outdoor 3x300sq.mm XLPE |
| 66 | Steel Sections(M.S Channel, M.S. Angle, 32 mm Round Bar etc) |
| 67 | 11 KV 3 Core cable 3x120mm XLPE |
| 68 | 11KV cable jointing kit indoor 3x120sq.mm XLPE |
| 69 | 11KV cable jointing kit outdoor 3x120sq.mm XLPE |
| 70 | 11 KV Outgoing swithgear 200/100/5 Amp. 350MVA |
| 71 | 8.5 M long PCC pole |
| 72 | M.S. Angle Iron 65x65x6mm Bracing with 4 clamp |
| 73 | Top Channel 100x50mm with clamps 2240 mm. long |
| 74 | 11 KV Disc. Insulator Polymeric |
| 75 | 11 KV Disc fitting |
| 76 | 11 KV Pin Insulators Polymeric |
| 77 | Stay Set Complete |
| 78 | Earthing of Pole by MS earthing Rod |
| 79 | Safe Loading carriage including unloading & proper stacking of following store materials from any store of MVVNL to site. (33/11 KV Sub-station Utraula IPDS Distt-Balrampur) |
| 80 | 33 KV VCB 800A, 750 MVA |
| 81 | 33 KV Control Panel for Single T/F |
| 82 | C.T. O/D 33 KV CTR 200/100/1-1A |
| 83 | 11 KV Incoming switch gear 600/300/5A |
| 84 | 11KV 3 Core cable 3x300mm XLPE |
| 85 | 33KV Bus Isolator |
| 86 | 33KV Lightening Arrestor |
| 87 | 33 KV Fuse Set |
| 88 | 90lbs rail Pcs for T/F (44.64Kg/m) |
| 89 | ACSR Dog Conductor |
| 90 | 11KV cable jointing kit indoor 3x300sq.mm XLPE |
| 91 | 11KV cable jointing kit outdoor 3x300sq.mm XLPE |
| 92 | Steel Sections(M.S Channel, M.S. Angle, 32 mm Round Bar etc) |
| 93 | 11 KV 3 Core cable 3x120mm XLPE |
| 94 | 11KV cable jointing kit indoor 3x120sq.mm XLPE |
| 95 | 11KV cable jointing kit outdoor 3x120sq.mm XLPE |
| 96 | 11 KV Outgoing swithgear 200/100/5 Amp. 350MVA |
| 97 | 8.5 M long PCC pole |
| 98 | M.S. Angle Iron 65x65x6mm Bracing with 4 clamp |
| 99 | Top Channel 100x50mm with clamps 2240 mm. long |
| 100 | 11 KV Disc. Insulator Polymeric |
| 101 | 11 KV Disc fitting |
| 102 | 11 KV Pin Insulators Polymeric |
| 103 | Stay Set Complete |
| 104 | Earthing of Pole by MS earthing Rod |
| 105 | Earth Mat- Laying of earth mat in the Switchyard by laying of MS round bar of 32 mm Dia in 750 mm deep trenches and grounding of earth mat with MS Round bar 32 mm Dia 3 Mtr. Long earth electrode as per respo drawing. The work includes welding/ bolting of MS round bar, G.S. strip and connecting all steel structure in the switchyard with the earth mat by means of G.S. strips of size 50x6mm as per item below. |
| 106 | Digging of trench of size 500x750mm for laying of 32mm Dia MS round bar including refilling of earth and ramming the same after laying of MS round bar/G.S. strip |
| 107 | Laying and welding of lap joints of MS round bar of 32mm Dia with minimum 150mm overlaping. The MS round shall be welded on both side so as to fill the wedges completely using high quality Arc welding and good work Manship. The Joint shall be covered with black Bitumen Paint. |
| 108 | Fabrication of 32mm Dia MS round bar 3 Mtr long earth electrodes and driving them into ground so that tip of the electrodes remains atleast 750mm below the ground level and Jointing of earth electrodes 32mm Dia with the earth mat using high quality Arc welding and good workmanship. |
| 109 | Jointing of MS round bar 32mm Dia in earth mat at cross joints using high quality Arc welding. A 75mm piece of 32mm Dia MS round bar shall also be welded to make the joint strong for carrying fault current. The joints shall be covered with black Bitumen Paint. |
| 110 | Providing and laying of G.S. strip of size 50x6mm for connecting the earth mat with the super structure, Security fencing post, Including digging of trench 500x500,, bending, cutting, straightening and welding of the earth strip with the earth mat and various street structure using high quality Arc welding. The work include proper overlapping of the strip and jointing by welding . |
| 111 | Plinth of 5 MVA, for 33/11 KV T/Fs - Construction of Plinth of size 3.46x3.46 Mtr suitable for 5 MVA to 10 MVA T/F Plinth decided by E/I. The work includes Excavation of foundation, base concreting in C.C. 1:6:12 ratio (cement, coarse sand and brick ballast) Ist Class bricks work in cement mortar of ratio 1:4 foundation, C.C.in 1:4:8 ratio (cement, coarse sand and brick ballast) and RCC working ratio 1:2:4 (cement, coarse sand and stone grit of 20 mm gauge) using MS Bars of 10 mm Dia (Tor) in reinforcement including its cutting, bending and binding in required shape. The work also includes laying of 2 Nos. 3.46 mts long each rail pieces complete with cutting, welding and proper fitting etc. The Plinth will be made as per Drawing and shall be plastered/ finished on Top and Side of the Plinth. |
| 112 | Fabrication, Erection & Grouting of Sub Station Structure |
| 113 | Bus Isolator Structure - Fabrication of isolator structures 3.5mtr in height as per drawing No. RES 39 Digging of two Nos. Pits of size 1.075 x0.9 xO.3 Mtr providing stone pad at the bottom of the pit and grouting pad at the bottom of the pit and grouting of two legs of the isolator structure in CC (cement, coarse sand and stone grit of 20 mm gauge) of ratio 1:4:8 in block of 1.075 mtx 0.3 Mtr including supply of all T&P complete in all respect. The work includes dragging, shifting upto 40 Mtr., Raising and erecting the two legs with runner of Isolator in proper allingment level and plumb. Both Plinths of the Isolator structure shall be properly finished with champering of edges. |
| 114 | Lightening Arrestor Structure - Fabrication of Lightening Arrestor per drawing No. RES 39 Digging of two Nos. Pits of size 1.075 x 0.3 xO.3 Mtr providing stone pad at the bottom of the pit and grouting of two legs of the above structure in CC (cement, coarse sand and stone grit of 20 mm gauge) of ratio 1:4:8 in block of 1.075 Mtr x 0.3 Mtr x 0.3 Mtr including supply of all T&P complete in all respect. The work includes dragging, shifting upto 40 Mtr. Raising and erecting the two legs with Top frame above structure's in proper allignment level and plumb. Both Plinths of the structure shall be properly finished with champering of edges etc. |
| 115 | Post Insulator,C.T. Structure,P.T. Structure & Fuse set Structure - Fabrication of Post Insulator,C.T. Structure & Fuse set Structure per drawing No. RES 39 Digging of two Nos. Pits of size 1.075 x 0.3 x O.3 Mtr providing stone pad at the bottom of the pit and grouting of two legs of the above structure in CC (cement, coarse sand and stone grit of 20 mm gauge) of ratio 1:4:8 in block of 1.075 Mtr x 0.3 Mtr x 0.3 Mtr including supply of all T&P complete in all respect. The work includes dragging, Shifting upto 40 Mtr. Raising and erecting the two legs with Top frame above structure's in proper allingment level and plumb. Both Plinths of the structure shall be properly finished with champering of edges etc. |
| 116 | Plinth for 33 KV VCB - Construction of Plinth of 2.0X1.5X0.9(mtr) suitable for erection of super structure 33 KV VCB including grouting of Anchor boards in proper alligntment and level. Scope of work incluldes exvacation of foundation base concreting base CC 1:6:12(cement, Coarse sand and brick ballast) first class brick work in cement mortar of ratio 1:4 CC in ratio 1:4:8 and RCC work in ration 1:2:4(Cement, coarse sand and stone grid of 20 mm gaze) as per drawing. |
| 117 | Hiring of 3 phase diesel generator Set 02 nos. including Carriage,Loading, unloading operating charges (with fuel) at 33/11 KV Substation Under Construction in case L.T. Supply is not available near S/s within prescribed accessible limit. 63 KVA, Three phase D/G Set for fabrication and other work . |
| 118 | Erection and Installation Of 33/11 KV 10MVA/5MVA Transformer |
| 119 | Fabrication and grouting of M.S.Angle 50x50x6 mm in L shape & in proper size and allignment to provide support for the two separate earthing strips for Power Transformer Neutral including supply & fixing of two Nos Flexible Copper bonds for neutral earthing. |
| 120 | Fabrication and erection of cable support made of two pieces of M.S. Strip 50 x 50 x 6 mm, 3.0 Mtr long joined to each other by means of 5 Nos M.S. Flat 5Ox6mm pieces of size 150 mm long each by welding at equal intervals as per drawing and grouting in a block of size 300 x 300 x 700 mm complete with one coat of ready mixed primer and two coats of Alluminum Paint. This includes providing of four Nos. M.S.clamp made of M.S. flat for holding the Cable including nuts and Bolts and fixing of XLPE cable. |
| 121 | Special Delta Earthing by way of boring and lowering of \\"B\\" class G.I. pipe 50mm Dia, 20Mtr long from ground upto the water level.The G.S. strip size 50X6mm will be welded to the G.I. Pipe. The work also includes Cap & Clamps for pouring water, the cost of all material with all labour & T&P etc.Providing and constructing earth pit with GI pipe electrode, brick masonry chamber, RCC/CI cover, and watering arrangement, complete as per standard specifications. Complete in all respect. |
| 122 | Body earthing of 5 MVA T/F |
| 123 | Neutral of Transformer |
| 124 | Lightening Arrestor |
| 125 | 11 KV I/G & O/G Panel |
| 126 | 33KV Control Panel |
| 127 | Installation of Isolators - Assembling and installation of Bus isolator on the Isolator structure, adjusting of opening mechanism in proper alignment so as to ensure smooth operation of the same. In case of line Isolator proper operation of earth links shall also be ensured. The work includes fabrication for proper fixing if required. |
| 128 | Installation of lightning Arrestors - Assembling and installation/ mounting of three Nos. Lightening Arrestors on the L.A. structure/ complete with making earth connection (Separate) and line connections. The work includes fabrication for proper fixing if required. |
| 129 | Installation of Post Insulator & Fuse Set - Installation of 3 Nos Post Insulators on the post insulators structure & Fuse set. The work includes fabrication for proper fixing if required |
| 130 | Installation of CT's & PT's - Installation of 3 no. CT's of ratio 200/100/1 amp. On the Ct's structure & 3 no. PT (O/D Type)(33KV/110V) On P.T. structure The work includes fabrication for proper fixing if required. |
| 131 | Installation of VCB - Installation of 33 kv VCB 800 amp capacity complete in all respect including commissioning. |
| 132 | Installation of Switchgears & 11 KV Bus Coupler in Control Room- |
| 133 | Shifting, carefully and safely 11 KV Switchgear from out side of the , switch gear room, Including grouting the two Nos. 100x50x6mm channels pieces (each 800mm long including cutting to size) and, foundation Bolts in 1:2:4 CC (Including cutting of CC of the floor and finishing of Floor) as per direction of Engineer Incharge, Placing and fixing of switchgear on foundation providing nuts & bolt of proper size in proper position in the alignment and filling of oil in tank after cleaning and checking, complete work with mounting of P.T. on incoming S/G. |
| 134 | Fixing and making Bus Bar connection in between all switchgears after cleaning and tapping with H.T. tape, Empire tape and PVC tape properly Providing and fixing of 6mm thick bakelite seperators and plugging of all opening and holes with plastic compound. complete work including cost of all material ( Except Copper Bus Bars) Strictly to the satisfaction of site incharge |
| 135 | Shifting carefully and installation of 33 KV single/double Transformer Control Pannel in room including grouting of above and its proper connection. |
| 136 | Earthing of 11 KV & 33 KV Switchgear |
| 137 | Earthing of all indoor equipment by providing and laying G.S. strip 50 x 6 mm including cutting, welding, bending etc. |
| 138 | Providing and laying of G.S. strip of size 50x6mm for connecting the earth mat with the super structure as well as body and neutral of power T/F, 33 kv VCB, C.T. structure, L.A. structure, post insulator structure up to equipments including digging of trench 500x750mm (approx) deep till existing earth mat, bending, cutting, straightening and welding of the earth strip with the earth mat and various steel structure using high quality Arc welding. The work include proper overlapping of the strip and jointing by welding . |
| 139 | H.T. Cable Laying - |
| 140 | Laying & dressing of 11 KV, 3x300 Sq.mm XLPE Cable underground from 5 MVAT/F to 11 KV incoming switchgear in the trench 450mm wide, 900mm deep, providing 150mm fine sand cushion bench and 150mm fine sand cushion above the cable. The cable shall be duly protected by 1st class bricks two either side and third on top of the cables. The cable shall be duly protected by 1st class bricks two either side and third on top of the cables, laid in series one after the other, the work includes supplying of fine sand and bricks, refilling and ramming of the left out soil, closing the trench and leveling. Spare cable shall be left and buried in the trench in the safe of rings at both ends. Cable laying work includes unrolling, cutting, meggering and sealing both end of the cable.Supply & fixing of double compression brass cable gland with all accessories including earthing tag, shroud, complete termination, testing & commissioning as per IS/IEC standards. |
| 141 | Laying & dressing of 11 KV, 3x120 Sq.mm ground cable in the trench 450mm wide, 900mm deep, providing 150mm fine sand cushion bench and 150mm fine sand cushion above the cable. The cable shall be duly protected by1st class bricks two either side and third on top of the cables, laid in series one after the other, the work includes supplying of fine sand and bricks, refilling and ramming of the left out soil, closing the trench and leveling. Spare cable shall be left and buried in the trench in the safe of rings at both ends. For the protection of the cable 100mm Dia G.I.pipe has to be provided on the Cable where the cable is to be laid across PUCCA/Main Road/ Nallah. Cable laying work includes supply of G.I.Pipe, unrolling, cutting, meggring & sealing both ends of the cable.Supply & fixing of double compression brass cable gland with all accessories including earthing tag, shroud, complete termination, testing & commissioning as per IS/IEC standards. |
| 142 | Hoisting of 11 KV cable, cable box, fixing with clamp nut & bolt with proper clamping with provision of G.I. pipe 3 mtr long of 150 mm dia.(All material will be supplied by the contractor) |
| 143 | Supply ,Fixing and fabrication and erection of cable jointings kits suitable for following sizes of 11 KV XLPE cable of 11 KV cables. With housing of 3.5Mtr long 100 sq.mm. Dia G.I.pipe with feeder cable at feeder D/P. |
| 144 | 11 KV 3x300 sq.mm. indoor jointing kit |
| 145 | 11 KV 3x300 sq.mm.outdoor jointing kit |
| 146 | 11 KV 3x120 sq.mm. indoor jointing kit |
| 147 | 11 KV 3x120 sq.mm. outdoor jointing kit |
| 148 | Erection & Grouting of 2 Nos 11Mtr STP support for making D/P structure Including fabrication, Fixing of MS Channel, M.S. angle etc. The work Includes supply and fixing of necessary clamp with nut, bolts and washers & Stay set including grouting. The work also includes grouting of double pole supports in CC 1:4:8 in block of size 0.45Mtr into 0.45Mtr into 2.0Mtr earthing of Double pole with M.S. earthing rod, complete in all respect. Painting of one Coat of Red Oxide Primer and Two Coats of Aluminum paint of good quality. (All material excluding 2 Nos of STP will be provided by contractor.) |
| 149 | Supply & Laying of 2x2.5 sq.mm./ 4x2.5 sq.mm. armoured control cables in trench & related all the work complete in all respect including Supply & fixing of double compression brass cable gland with all accessories including earthing tag, shroud, complete termination, testing & commissioning as per IS/IEC standards.Control cables shall be properly terminated using suitable size lugs and ferrules, ensuring correct identification, tight connections, and reliable operation as per standard practices. |
| 150 | Construction of control cable Trench Pacca by Coarse sand, Bricks & cement in size ( 300 mm wide x 450 mm depth) with cover as per Norms including Supply & fixing of MS rest angles in cable trench for supporting control cables, including painting, fastening, and all materials, labor & consumables, complete. |
| 151 | Laying and Fixing of lnterlocking Bricks in the Switchyard 1.5 Mtr wide. Making approach path after Proper leveling and finishing etc. The work includes cost of all the material. |
| 152 | Maintenance & Repairing of 5MVA T/F |
| 153 | If The B.D.V. of Oil is Low then the centrifusing of Transformer Oil is Necesarry On the Basis for requirement of Centrifusing of Transformer Oil,All the Equipment and Machinary Needed For Centrifusing of Oil shall be provided By Contractor. |
| 154 | Supply and Installation of Silica Gel With Cabinet. |
| 155 | Supply and Installation of OTI&WTI |
| 156 | Painting of 5 MVA T/F |
| 157 | Replacement of Damage oil seal/Packing |
| 158 | Painting of Structure Painting of following structure with one coat of ready mixed primer and 2 coats of AL.Paint of good quality including cost of material, Labour and T&P complete in all respect. The work includes cost of all the material. |
| 159 | Bus/Line Isolator Structure |
| 160 | Lightening Arrestor |
| 161 | Post Insulator Structure |
| 162 | Cable Stand |
| 163 | Neutral Stand |
| 164 | VCB & CT Structure |
| 165 | Supply, fixing and mounting of following equipments/ items in the control room |
| 166 | Rubber matting one side chequered and other side plane size 1800x900x12mm |
| 167 | Rubber hand gloves |
| 168 | Commissioning & Testing of 01 No. 5MVA T/F / 10 MVA T/F and its eqipments installed in switchyards and 11 KV Incoming and Outgoing Pannels complete in all respect upto energising.(Work includes testing,repairing of control circuit if requiured to ensuring proper working of all Protection system.) |
| 169 | GEO tagging of Respective Work according to corporation Letter no. 2259/CMUD/SE-1/2025. Please Enable Macros to View BoQ information |