Tender For Running Maintenance & Operation Of Electrical & Mechanical Services, Sub-Station, Dg Set, Pump Set, Passenger Lift, Fire Fighting, Fire Alarm, Wet Riser System R.O. Installed In Various Blocks At Vikas Bhawan, I.P. Estate, New Delhi (Sh:-, Delhi-Delhi
TDR : 55303846
Tender Notice
BOQ
4 Days Left
Delhi
Delhi
Tender For Running Maintenance & Operation Of Electrical & Mechanical Services, Sub-Station, Dg Set, Pump Set, Passenger Lift, Fire Fighting, Fire Alarm, Wet Riser System R.O. Installed In Various Blocks At Vikas Bhawan, I.P. Estate, New Delhi (Sh:-
Name of Work:- Running Maintenance & Operation of Electrical & Mechanical Services, Sub-Station, DG Set, Pump Set, Passenger Lift, Fire Fighting, Fire Alarm, Wet Riser System R.O. installed in various Blocks at Vikas Bhawan, I.P. Estate, New Delhi (SH:- Replacement of Non-Functional old outlived Air-Conditioners at various Blocks, Vikas Bhawan).
Sl. No.
Item Description
1
Supply, Installation, Testing and Commissioning of Air Cooled HI Wall split type Air conditioners complete with Indoor unit (IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cut off and50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll /rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS694 or IS 9968 temperature sensing control IS/ International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS :1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature).Inverter Type - Cooling only1.1) 2.0 TR with 5 Star BEE Rating
2
1.2) 1.5 TR with 5 Star BEE Rating
3
Supply, Installation, Testing and Commissioning of Air Cooled Floor standing Tower type split Air conditioners of capacity 2.4 TR complete with Indoor unit(IDU), Out door unit (ODU), surface/ concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5 Mtr (IDU to ODU), copper power cable upto 5.5 Mtr (IDU to ODU), i/c drain pipe of suitable length and size. R-32/R-410/R-407C Green Refrigerant, wireless Remote control, suitable for working between 180-260Vwith low & high voltage cut off and 50 hz,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll/ rotary with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB) as specified. The system shall be able to deliver 100% of the rated capacity as per relevant IS Code. The lab testing reports as per IS: 1391 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per International Electro technical Commission (IEC) 17025 standards/ Central Power Research Institute (CPRI)/ Electrical Research and Development Association (ERDA) with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification and as per IS: 1391 as required.’Cooling Only
4
Supply, Installation, Testing and Commissioning of Window type Air conditioners complete with copper power cable upto 3 Mtr, wireless Remote, suitable for working between 180- 260V with low & high voltage cut off and 50 hz, 1 phase AC supply capable of performing, cooling, dehumidification, air circulation, R-32/R-410A /R-407B Green Refrigerant with Scroll/ rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB), antifreeze thermostat on the coil as a safety feature, complete with fixing including T&P & labour etc. as required complete in all respect as specified of following capacity. Sound level of up to50dB inside the room is acceptable. The unit shall be in confirmation with IS 1391 Part-I 2023 and CPWD Specification. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. The system shall be able to operate upto 50 Degree C (out door ambient temperature).Inverter Type(a) 1.5 TR with fixed speed 5 Star BEE rating
5
Providing & Laying of refrigerant copper piping of size 1/4\\" or 3/8\\" & 5/8\\" diameter from indoor unit to outdoor unit of split type Air Conditioner unit along with 4 core 2.5 sq.mm PVC insulated and PVC sheathed flexible copper conductor cable including 20 mm size of cotton thread ribbed PVC flexible pipe from drip tray of Air Conditioner unit to drain pipe along with necessary support complete etc all as per Direction of Engineer-in-charge.
6
Supplying & drawing of 3x4 sqmm size of PVC insulated &pvc sheathed copper conductor round multicore flexible cable for indoor to outdoor and upto nearest power point i/c providing suitable copper lugs connection etc. as required.
7
Providing & fixing of 25 mm dia (SDR-13.5) UPVC heavy duty white colour drain pipe of with necessary fitting such as nipple, reducer, clamp on surface / recess i/c cutting the wall and making good the same complete as required.
8
Credit of following items etc. complete as required.(a) 1.5/2.0 TR Split Type AC
9
(b) 1.5 TR Window Type AC Please Enable Macros to View BoQ information
We takes all possible care for accurate & authentic tender information, however Users
are requested to refer Original source of Tender Notice / Tender Document published by
Tender Issuing Agency before taking any call regarding this tender.