| 1 | Supply, installation and commissioning of Electromagnetic flow meter complete as per specifications including all items 300 mm dia |
| 2 | Ultrasonic/Radar level transmitter Designing, Supplying, Installing, commissioning and testing of Ultrasonic /Radar type level transmitter with following technical parameters and Interfacing with PLC/RTU panel including mounting arrangement. Output-4-20 mA Power supply 24V DC ext. Range- 0 to 5m/0-10m as per site depth Accuracy - plus /- 0.25% of Full Scale or better Enclosure- IP 67 at field locations and integration with PLC/RTU at Ranney well, MBS, IBS and SBS Locations of suitable depth. (detail specifications at Section – 7.2). |
| 3 | Pressure Transmitter Designing, Supplying, Installing, commissioning and testing of pressure transmitter with following technical parameters and Interfacing with PLC/RTU panel including mounting arrangement. Output 4-20 mA Power supply - 24V DC Accuracy - plus /- 0.1 % of full scale or better Enclosure- IP 67 at Individual Pumps and Common Header Points (detail specifications at Section – 7.2) |
| 4 | Designing, Supplying, Installing, commissioning and testing of Energy Meter interfacing to PLC/RTU Panel with Modbus communication port , as per IEC 62053 and in the prescribed format including mounting arrangement complete in all respect. (detail specifications at Section – 7.2) |
| 5 | Providing, installation, testing and commissioning of UPS (minimum size 2 KVA) with at least 4 Hrs backup at all the stations so as to control entire instrumentation, PLC/RTU etc. (detail specifications at Section – 7.2) |
| 6 | Supply, Installation, Commissioining of Remote Terminal Units(RTU)/PLC sufficient AIOs and DIOs, with HMI 7` Screen with 65000 Colours, as might be necessary including , Panel Box IP54 rated, fitting and accessories including capability to communicate Central control room, MPS, Cables, JBs, Trays and Conduits etc. at Ranney wells so as to perform functionalities as per scope of work at MBS, IBS and SBS Locations Tentative AIODIO: DI-29,DO-14,AI-10, Modbus-1, Ethernet port -1 (detail specifications at Section – 7.2) |
| 7 | GSM/GPRS connectivity at all PLC locations |
| 8 | Electrical and allied works:supplying and installing following size of perforated painted with powder coating M.S cable tray with perforation no more than 17.5%, in convenient sectionsjoined with connectors, suspended from the ceiling with M.S suspenders including bolts and nuts, painting suspenders etc. as required. (detail specifications at Section – 7.2) |
| 9 | Electrical and allied works:supplying and installing following size of perforated painted with powder coating M.S cable tray with perforation no more than 17.5%, in convenient sectionsjoined with connectors, suspended from the ceiling with M.S suspenders including bolts and nuts, painting suspenders etc. as required. (detail specifications at Section – 7.2).. |
| 10 | Providing and layingstranded/flexibleannealed bare copper conductor XLPE/PVC insulated suitably laid up together overall polyster taped AI (Mylar tape wrapped) along with ATC Drain wire overall PVC sheathed (ST-1) overall csreened pair armoured instrumentation cables generally confirming to PAS 5308- part-2-2009. (detail specifications at Section – 7.2) |
| 11 | Providing and layingstranded/flexibleannealed bare copper conductor XLPE/PVC insulated suitably laid up together overall polyster taped AI (Mylar tape wrapped) along with ATC Drain wire overall PVC sheathed (ST-1) overall csreened pair armoured instrumentation cables generally confirming to PAS 5308- part-2-2009. (detail specifications at Section – 7.2).... |
| 12 | Supply and erection of main LT panel, Panel, incomming 1 No. ACB 1000 amp FP 50 KA MDO with microprocessor based SR18G, 2 nos indiaction ON/OFF, 3 nos CT`s 1000/3 ratio, Digital Voltmeter and Ammeter with selector switch 1 no., with 630 amp MDO ACB,50KA with MP based O/C,S/C and E/F release mechanical interlock, auxillary contactors( 2 No. plus 2 NC) of DG incomer with outgoing 250 Hp VFD 1 NO. and 200 amp MCCB outgoing for 100 HP pump including trip contact, auxilary contact for MCCB and digital voltmeter and Ameter with ON/OFF trip indication lens and 4 No. 200 amp MCCB Outgoing spare including 2No. MCB outgoing for 10 hp dewatering pump including miscleneous items light,space heater with thermostart panel lamp with limit switchand neutral links etc. Including Electrical protection and foundation complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-Charge of the work. Make: Siemens/ L and T/ ABB/Schnider (Excluding GST):- VFD Panel,As old panel is totally demaged |
| 13 | Supply and erection of Rubber Mat 1mx2mx 12mm thick suitable for 11/33 KVA as per IS No. 15652C/M/L 3017739 as per approved by Chief Electrical inspector, Govt. of Haryana (Excluded GST) |
| 14 | S/E of fire bucket 9 Ltrs Capacity of G.I. sheet of 24 gauge write with ` FIRE` as per fire specification.(Excluded GST) |
| 15 | S/E of MS bucket stand suitable for six Nos. fire buckets (but without buckets) including the cost of welding and painting with all cost of red oxide and two coat of enameled paint of red colour completion all respect.(Excluded GST) |
| 16 | 6.5 KG CO2 Type Fire Extinguisher |
| 17 | Dismentaling of Electric Panel, Cable carrier, Damage electrical equipments and all other electrical wastage |
| 18 | Dismantling ,Shifting and refixing /installation of 250 and 100 HP induction motor pumps and panel from new chamber tank to old chamber including hydra machine and other accessories complete |
| 19 | Labour charges for Cutting holes 2 Nos. in both tanks in vertical walls and Making good the same after work and jointing of 450 mm dia pipes with other cracks repair using epoxy compound coating like FIS-V-PLUS injection mortar complete |
| 20 | Supply and installation of CFL Lamps ISI Marked. 13-18 watts |
| 21 | Dismentling of existing MS delivery and suction pipes 150-300 mm dia with CI specials ,nut ,bolt, and stacking the same |
| 22 | Supply, fixing and commissioning of M.S. Pipe (spiral welded) 200 mm i/d ,10 mm thick (Fe-330 ), MS plate of Make JINDAL ,TATA, Essar, with bituminous coating of 4 mm thickness (minimum) on outside and two coats of Food grade Epoxy paint inner linning 200 micron minimum, fabricated as per IS 3589 of 1991 from steel plates confirming to IS :-2062 including cutting , bevelling, grinding with radiographically spiral welding of pipe as per IS-1182 and testing complete in all respects to the entire satisfaction of Engineer-in-charge. For inlet Header in old and new chamber |
| 23 | Labour charges for Making connections of new Headers with existing Header near old chamber, inside old and new chamber complete with using welding set,mechanical cutter/grinder,gas cutter,MS sheet (if required) with labour |
| 24 | Providing and fixing sluice valves/flap valves socketed or flanged including cartage from stores. 200 mm i/d |
| 25 | Providing and fixing sluice valves/flap valves socketed or flanged including cartage from stores. 250 mm i/d |
| 26 | Providing and fixing sluice valves/flap valves socketed or flanged including cartage from stores. 300 mm i/d |
| 27 | Providing and fixing sluice valves/flap valves socketed or flanged including cartage from stores. 350 mm i/d |
| 28 | Providing and fixing sluice valves/flap valves socketed or flanged including cartage from stores. 400 mm i/d |
| 29 | Providing and fixing sluice valves/flap valves socketed or flanged including cartage from stores. 450 mm i/d |
| 30 | Analysis of rates providing and fixing of CI NRV IVC/VAG/Kirloskar make of PN 16 rating, including, carriage, loading and unloading and fixing, complete in all respect as per satisfaction of the Engineer-in-Charge. 350 mm i/d |
| 31 | Hiring of tractor with dewatering pump including other accessories for 10 hrs. working |
| 32 | Painting of Truss bridge with spray pump complete in all respects including air sprayer, scaffolding, ladder, rassa, safety belt, gen set, grinder etc. |
| 33 | supply and installation of 2 HP dewatering motor pump complete as per specification |
| 34 | supply and installation of 5 HP vaccum motor pump complete as per specfication |
| 35 | supply and fixing of G.I pipe B class for dewatering and vacuum pumps with fittings 40 mm dia. including HSR B1144 |
| 36 | Supply and fabrication of MS Flanges made from 8 mm thick MS sheet complete with cutting from sheet, drilling holes etc. 150 mm i/d |
| 37 | Supply and fabrication of MS Flanges made from 8 mm thick MS sheet complete with cutting from sheet, drilling holes etc. 200 mm i/d |
| 38 | Supply and fabrication of MS Flanges made from 8 mm thick MS sheet complete with cutting from sheet, drilling holes etc. 250 mm i/d |
| 39 | Supply and fabrication of MS Flanges made from 8 mm thick MS sheet complete with cutting from sheet, drilling holes etc. 300 mm i/d |
| 40 | Supply and fabrication of MS Flanges made from 8 mm thick MS sheet complete with cutting from sheet, drilling holes etc. 350 mm i/d |
| 41 | Supply and fabrication of MS Flanges made from 8 mm thick MS sheet complete with cutting from sheet, drilling holes etc. 400 mm i/d |
| 42 | Supply and fabrication of MS Flanges made from 8 mm thick MS sheet complete with cutting from sheet, drilling holes etc. 450 mm i/d |
| 43 | Labour charges for repair of burst/cracked/damaged rising main within Truss Bridge over Agra and Gurugram Canals including DG set, gas cutter, methane/oxygen gas,grinder,welding rods,MS sheet (if rq.) etc.Truss bridge over Agra canal |
| 44 | Labour charges for repair of burst/cracked/damaged rising main within Truss Bridge over Agra and Gurugram Canals including DG set, gas cutter, methane/oxygen gas,grinder,welding rods,MS sheet (if rq.) etc.Truss bridge over Gurugram canal |
| 45 | Supply and fixing of GI pipe class -B nipple for pump80 mm i/d |
| 46 | Supply and fixing of GI pipe class -B nipple for pump100 mm i/d |
| 47 | Supply and fixing of heavy duty MS clamp made from 10 mm thick MS sheet80 mm i/d for lowering pipe of Tube well |
| 48 | Supply and fixing of heavy duty MS clamp made from 10 mm thick MS sheet100 mm i/d for lowering pipe of Tubewell |
| 49 | Supply and fixing of MJ collar 300 mm dia complete with rubber rings and nut bolts of required size , C.I coller thickness is 10 mm to 20 mm (0.5-0.8 in ) conferming to marked with ISO 2531, AWWA C10 , no. of holes 15 to 20 .The rubber ring EBDM made (ethylene propylene diene monomer )or NBR ( nitrile butadiene rubber) with hardness 52 to 70 shore a unit. ensure the rubber ring material is compatible with the fluid or gas being transpoted.,size of rubber ring match to the MJ coller and pipe specifications and rubber is suitable for the operating temperature range. |
| 50 | Supply of lock, 6-7 leavers, harison etc. make |
| 51 | Supply of Broom, Broom with bamboo handle 6` long , bamboo sticks complete |
| 52 | Supply of chargeable torch Eveready make |
| 53 | Supply of PVC Bucket, mug, (1 ltr), jug (2 ltr), tray with 4 glass(kantch),liquid soap, (Dettol), hand towel, PVC flexible pipe 1` dia,(1 roll). |
| 54 | Supply and fixing of Dismantling joint with Nut and bolt complete200 mm |
| 55 | Supply, fixing and commissioning of M.S. Pipe (spiral welded) 450 mm i/d ,10 mm thick (Fe-330 ), MS plate of Make JINDAL ,TATA, Essar, with bituminous coating of 4 mm thickness (minimum) on outside and two coats of Food grade Epoxy paint inner linning 200 micron minimum, fabricated as per IS 3589 of 1991 from steel plates confirming to IS :-2062 including cutting , bevelling, grinding with radiographically spiral welding of pipe as per IS-1182 and testing complete in all respects to the entire satisfaction of Engineer-in-charge FOR MAKING inter connection of old and new tanks. |
| 56 | Supply, fixing and commissioning of M.S. Pipe (spiral welded) 300 mm i/d ,10 mm thick (Fe-330 ), MS plate of Make JINDAL ,TATA, Essar, with bituminous coating of 4 mm thickness (minimum) on outside and two coats of Food grade Epoxy paint inner linning 200 micron minimum, fabricated as per IS 3589 of 1991 from steel plates confirming to IS :-2062 including cutting , bevelling, grinding with radiographically spiral welding of pipe as per IS-1182 and testing complete in all respects to the entire satisfaction of Engineer-in-charge -for making connection of 250 HP motor pump assembly to rising main. |
| 57 | Labour charges for Cutting holes (4 Nos.) in old tank and Chamber walls for inserting 300 mm MS pipe and making good the same after work and jointing of 300 mm dia. Pipe to inlet of motor pump with Reducer matching the suctions size of the pump.(For tank and old chamber) |
| 58 | GI pipe 32 mm dia bend for street light- 1 metre long |
| 59 | Over hauling of 750KVA Transformer including oil filteration and bushing work etc. completer in all respects. |
| 60 | O and M of IBS at Budhena Booster including 11 No. Tubewells, motor 1No. 100 HP, 2 NO. 60 HP, 2 NO. 30 HP ,2 NO. 3 HP , 11 NOS. 15 HP and DI pipe line 200mm /300 MM size and 2800 meter AND 300 MM/400 MM DIA 5800 meter length including Establishment maintenance and repair charges in all other work contingent thereto. |
| 61 | HSR Items- Master Water Supply Scheme Faridabad- Special repair of IBS Budhena (including 11 No. Tube wells along Agra canal and near IBS Budhena) including replacement of unserviceable EandM components, repair of civil structures, replacement of existing pipeline 200mm and 300mm with D.I Pipeline independent electric feeder main LT line, transformers and DG sets, Road repair and all other works contingent thereto with OandM for a period of 2 years. Please Enable Macros to View BoQ information |