| 1 | Supply installation testing and commssioning of the ceiling fan with the following specifications:i. Sweep: 1400mmii. Minimum RPM: 300iii. Power consumption: 75wComplete in all respects and as directed by engineer in charge |
| 2 | Supply and installation of VCB (630A)11 KV Switchgear Panel , 12kV, 500 MVA for 1 Secs., 12500A , VCB switchgear panel with required PT`s, CT`s, protective relays, metering equipment, auxiliary equipment, extensible (both sides) and including foundation , complete cable termination kits as per cable sizes specified in SLD .All the panel, relays and meters etc. shall of same make, i.e. 11KV switch gear offered should come as complete unit from the manufacture and relays, meters, panel etc. shall be of that manufacture only. |
| 3 | Supply installation testing and commissioning of Multi rack mechanical course bar screen CW:1400 mmCD: 9500 mmWD:1400 mmBar Spacing :20 mmBar Size: 10X50 mmInclination 75 Degree MOC SS-304Along with panel andsensor and conveyer belt for sewer disposal /intermediate pumping station approved make JASH/Voltas /Johnsons/Oriental casting as per satisfaction of Engineer – in – Charge complete in all respect |
| 4 | Providing, fixing, testing of Manual coarse screen of size 1500mm x3000mm of SS 304 with following material :-SS04 Channel 100X50X5,and Angle-640KgSS Patti(32X5)-207KgFastner -20No.Chain pully ,Manually-01L-Section 250X125 with MS Angle size 50X5 = 1025 KGMS Plate 400X400X12-46 KgTower Sal with chain -01 NoI/c Fabrication hydra etc. and i/c diversion of sewage during installation.Make:- Jindal |
| 5 | Operation and maintenance during defect liability period after three month trial runTrial run will be at the cost of agency. |
| 6 | Operation and maintenance in 1st Year |
| 7 | Operation and maintenance in 2nd Year |
| 8 | Supply of 400 KVA (DG set Model KG4-400WS) Prime Duty (as per ISO 8528-I), 415 Volt, Radiator Cooled, Silent Type with acoustic enclosure as per approved design as per CPCB IV, Diesel generating set having powered with suitable capacity prime duty Kirloskar Engine model DV8ETA 4G2 having 490 BHP@1500 rpm along with base frame, Alternator (capable of delivering electrical output of 400 KVA output @ 0.8 power factor, 50 Hz, 415 V, Class H with temp rise limited to class H at 40 deg C ambient), Static Excitation System, Lub Oil System, Electronic Governor (Class G3 Governing) including Microprocessor based Gen set Controller as per Kirloskar standard design, AVM pads, required 2 Nos 12 volt Lead Acid type Battery with Copper leads suitable for 3 consecutive starts, Silencer/s as per approved design of Kirloskar with bellow/s, inbuilt Day oil tank of 890 liters approx. as per Kirloskar standard design, terminal arrangements including cable termination box suitable for terminatingof recommended size Al cable with all other associated items/accessories and AMF Panel complete in all respect |
| 9 | 200 watt Flood LED Lighting and Fixture as per required complete in all respects. |
| 10 | 120 WATT LED Street Lighting Fixture as per required |
| 11 | Analysis of Fire Bucket 9 litr capacity of GI sheet of 24 Gauge with fire bucket stands complete in all respects |
| 12 | Analysis of MS Bucket stand suitable for fire safety complete in all respects |
| 13 | Fire extinguisher |
| 14 | Supply and installation of Main LT panel made up of 14/16 SWG MS CR sheet duly powder coated with Siemens Gray Shade, dust free and vermin proof with heat shrink sleeved aluminum bus bar with suitable size main incomer 1250A Specifications of LT Panel:- Make LandT/ ABB/ Schneider MAIN INCONER 1250A 4P 50KA ACB EDO MICROPROCESSOR BASED SR 18GDRAW OUT TYPE RELEASE (O/C, S/C )220VAC - SUNT RELEASE 220VAC - UNDERVOLTAGE RELEASE 220VAC - CLOSING RELEASE 230V AC LED - PHASE INDICATOR RED, YELLOW, BLUE 500V - DIGTAL VIF METER3PH 1600/5A - METERING CTS , 5VA CLASS - 16A SP- MCB 10 KA C-CURVE 4-6 MM - CT and NAUTRAL TERMINAL 1.5/2.5 Sq mm - WIRING WITH COPPER WIRE INCOMER 1 ( DG SET ) 1000A 4P 50KA - ACB EDO MICROPROCESSOR BASED SR 18GDRAW OUT TYPE RELEASE (O/C, S/C ) 220VAC - SUNT RELEASE 220VAC - UNDERVOLTAGE RELEASE 220VAC - CLOSING RELEASE 230V AC LED - PHASE INDICATOR RED, YELLOW, BLUE 500V - DIGTAL V METER 3PH 1000/5A - METERING CTS , 5VA CLASS - 16A SP - MCB 10 KA C-CURVE 4-6 MM CT and NAUTRAL TERMINAL1.5/2.5 Sq mm - WIRING WITH COPPER WIRE 6A SP MCB 10 KA C-CURVE 230V AC LED - PHASE INDICATING RED, YELLOW, BLUE 1.5/2.5 Sq mm - WIRING WITH COPPER WIRE 24VDC - BATTERY CHARGER OUT GOING 400ATP plus N 36KA DN3B-400D - MCCB WITH THERMAL-MAGNETIC 400ATP plus N 36KA DN3B-400D - MCCB SPREADER TERMINAL 400ATP plus N 36KA DN3B-400D- -MCCB HANDLE (ROM) with 4nos. soft starter panel/VFD BUS BAR MAIN BUS BAR CHAMBER OF 1250A FP ALUMINIUM WITH COLOR COATED HEADED SHRRINKABLE SLEEVES AND OUT GOING ACCORDING TO AMP. ACCESSORIES -THIMBLES, H/W, WIRE TIE, WIRE SLEEVE, PANEL DOOR LOCK, GASKET A ACB DGSET incomer supply 800A ACB with 4 nos. outgoing panel for running 200HP each motor including multifunction meters with each feeder. All the ACB/MCCB shall have potential free auxiliary contacts for on/off, trip function. Outgoings: i) 400A FP, 25 kA, MCCB (microprocessor based release with overload, short circuit, earth fault protection, 1 no. NO/NC auxiliary contact and shunt trip, RS-485 communication module similar to Legrand DPX3 250 or equivalent): 2 Nos.All the MCCBs shall have potential free auxiliary contacts for ON, OFF, TRIP All the MCCB shall have suitable rotary handle with facility for Pad locking Ul) All Breakers shall be provided with Shunt trip coil and auxiliary contacts.iv) Insulated shrouding shall be provided for live partsv) FRLSH PVC insulated copper wires (not less than 2.5 Sq mm) shall be used for control wiring.vi) CT`s shall be provided with shorting terminals.vii) Earthing of LT panel should be done with in all respect.complete in all respects Make |
| 15 | Supply and jointing three core submersible flat cables of approved make with bare bunched copper conductor insulated and sheathed with PVCfor submersible pump motors /fountain lights etc with voltage grade 1100 volts marked with IS:694, 1990 including cost of jointing, materials aswell as carriage, loading, unloading etc. complete in all respect up to the entire satisfaction of Engineer- in-Charge.Submersible Copper Cable 3 Core 25 sqmm |
| 16 | Providing and fixing and commissioning of non-clog submersible sewage pump having discharge 750m3/hr. and 20mtr.head with suitable HP Motor including LT PMU, Auto coupling with integral bend including loading unloading etc and complete in all respects . Make Aqua |
| 17 | Supply Installation Testing and Commissioning of rising spindle flush bottom CI Sluice Gate size(1000mmx1000mm) generally conform to IS:133-19 material detail 1 Frame, door, guide, extension, wedge, wall thimble, floor standard. CI. to IS 210 Gr. Fg 260 2 Spindle SS: 304 3 Seating faces SS :304/SSCF8 4 Wedge Block DI with SS AISI: 304/CF8 Lining 5 Lift Nut High termite brass(HT2) 6 Fastener (Thimble/Adjustable wedge) Stainless steel 7. Other fasteners Carbon steel 8 Extension spindle SS: 304 9 Guide bracket CI to IS.210 Gr. Fg.260 10. Coupling SS AISI: 304 for sewer disposal/ Intermediate Pumping Station Approved make as per satisfaction of Engineer- in-Charge complete in all respect |
| 18 | Analysis for Providing and fixing of Non-Return Valve 350mm Dia DI IVC make (PN 1.6) with DI pipe K-9 pipe including Carriage Loading and unloading complete in all respects as per satisfaction of the Engineer-in-charge. |
| 19 | Rate Analysis of Construction of Staff quarter and JE office complete in all respect. (As per plinth area rates by Haryana PWD BandR) |
| 20 | Analysis of overhauling of 500 KVA Transformer with Oil filtration Transformer Oil Filtration 500 KVA HT,LT, Top cover leakage repairing TRF IR Value testing Transformer silica gel breather Transformer Oil complete in all respects. Providing and fixing jointing testing commissioning aligning of 600mm Dia MS pipe with 10mm thick food grade epoxy paints complete in all respects and satisfactory Engineer-in-charge. |
| 21 | HSR Items- Master sewerage scheme Faridabad: - Designing, re-construction and commissioning of existing intermediate pumping station complete in all respect including construction of required civil structure such as panel room, DG room, Operator room, office with attached toilet, screen chamber, collecting tank, screen channel etc. and electrical and mechanical items as required for capacity of 15MLD (Average) at Sector-4R Disposal Faridabad Please Enable Macros to View BoQ information |