| 1 | Demolition of cement concrete (un-reinforced) in ground floors and paving's not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 2 | M&L for machine pressed rubber moulded precast coloured concrete interlocking paver block, any shape and size conforming to IS 15658-2006 of 80 mm thickness, grade M-40 with grey cement and no pigments complete all as specified and directed. |
| 3 | M&L for machine pressed rubber moulded coloured precast concrete interlocking paver block of size 200x200mm and 80 mm thickness square shape and , grade M-40 with grey cement and pigments, complete all as specified and directed. |
| 4 | M&L for sand filling under floor or in foundations including spreading leveling in layers n exc 25 cm thick, well ramming, watering and consolidation complete all as specified and directed. |
| 5 | M&L for PCC 1:4:8, Type D-2, using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and directed. |
| 6 | M&L for PCC 1:2:4, type B-1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including formwork for rough finished surfaces of concrete complete all as specified and directed. |
| 7 | M&L for 9-10mm thick coloured vitrified paver tiles (endura tiles) of size 600x600mm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 20mm thick screed bed in cement mortar 1:4, complete all as specified and directed. |
| 8 | M&L for chequered cement concrete tiles pre polished lacquer and glossy finish 30cmx30cmx20-23mm thick, set, jointed and pointed in neat cement slurry with grey cement and pigment in floors over a 15mm thick CM 1:6 screed bed, complete all as specified and directed. |
| 9 | Demolition of brick work or stone masonry built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and directed.Note: Reused stone for except stone work shall be as certained by BOO as approved by GE. |
| 10 | M&L for walling of random rubble stone masonry, brought up to courses, well bonded, bedded and solidly hearted built in CM 1:6 including raking or cutting out joints complete all as specified and directed. |
| 11 | All as per srl item No 10.00 above but \\"except stone\\" complete all as specified and directed.Note: Qty shall be certained by approved BOO. |
| 12 | M&L for brick work with sub class 'B' bricks old size straight or curved on plan built in CM 1:6, complete all as specified and directed. |
| 13 | M&L for hand packing with boulders or stones (any thickness) at the back of walls over arches etc. and raising (or lowering) to the required level, complete all as specified and directed. |
| 14 | S&F 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed. |
| 15 | Dismantling of floor hearth or wall tiling incl cement mortar bedding (but not backing) removing serviceable tiles to store & rubbish of the premises, complete all as specified and directed. |
| 16 | S&F wall cladding glazed ceramic tiles in vertical surfaces of size 450x300-350x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick backing on wall in CM 1:4, complete all as specified and directed. |
| 17 | M&L for taking down cement or cement lime plaster of any description on brick or stone walls etc including racking out joints, hacking for key scrubbing down with water etc complete all as specified and directed. |
| 18 | M&L for rough cast plaster complete as specified in SSR Part-I, clause 14.22 shall consisting of following:- firstly apply under coat in cement mortar 1:3 not less than 15 mm thick and while still it is in plastic state the rough cast mixture consisting of crushed stone or fine gravel agg. which is generally of size between 6 to 12 mm depending on texture required mixed with coarse sand and cement in the ratio 1:1:1 shall be applied, complete all as specified and directed. |
| 19 | M&L for preparation of new plastered /concrete surface of wall applying of two coats of cement base paint over a coat of chalk whiting ,on plastered surface, preparatory to distempering complete all as specified and directed. |
| 20 | M&L for rendering 15mm thick in cement plaster 1:4 on any faces of brick work or concrete wall surfaces and finished even and fair without using extra cement complete all as specified and directed. |
| 21 | M&L for preparation of new plastered/concrete surface of wall and applying two or more coats of 100% premium acrylic emulsion paint (weather proof paint on external surfaces) having VOC less than 50 gm/liter and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 liter/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 liter/ 10 sqm over new surfaces at any height of building/ tower complete all as specified and directed. |
| 22 | M&L for complete removal of existing treatment on walls, pillars cornices etc ( any number of layers) by scrapping with steel scrap or any other means, washing down with water to remove loose particles etc and applying/finishing walls with acrylic smooth exterior paint of required shade (two or more coats applied @ 1.67 ltr/10 sqm) complete all as specified and directed. |
| 23 | M&L for rolled mild steel framed work as in door ornamental and intricate design of door or gates of angle or other section with gusset plates, rails, braces etc. complete, drilled for fixing of steel sheeting or other covering, doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fitting (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing conforming to Fe-410-(Gde E-250) quality-'A', complete all as specified and directed. |
| 24 | M&L for framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-290, Gde-E-165, complete all as specified and directed. |
| 25 | M&L for 16-18 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:6) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and directed. |
| 26 | M&L for preparation of new steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 27 | M&L for RCC nominal mix 1:2:4, type B-1, using 20mm graded crushed stone aggregates as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 28 | M&L for TMT Mild steel bars 10mm dia and over cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 29 | M&L for form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work n exc 200mm thick, finished rough surfaces of concrete flat complete all as specified and directed. |
| 30 | Demolition of Cement concrete (un-reinforced) of any description and in any position not other wise specifically provided for complete all as specified and directed. |
| 31 | M&L for PCC 1:2:4, type B-1, using 20mm graded crushed stone aggregate as in coping to retaining walls/ steps/ parapet/ kerbs/ base of railing post etc., including necessary formwork complete all as specified and directed. |
| 32 | S&F 5mm thick plain poly carbonate translucent sheeting fixed with self tapping, screw and dismantling of old sheet complete all as specified and directed. |
| 33 | M&L for excavating in post holes hard/ dense soil (or similar holes) each n. exc 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc 25cm, watering and removing surplus soil to a distance n exc 50m and making good surface in hard/ dense soil, complete all as specified and directed. |
| 34 | M&L for PCC 1:2:4, type B-1, using 20mm graded crushed stone aggregate as in surface channel and drain etc., including necessary formwork and smooth fair finish complete all as specified and directed. Please Enable Macros to View BoQ information |
| 35 | M&L for PCC 1:2:4, type B-1, using 20mm graded crushed stone aggregate as in surface channel and drain etc., including necessary formwork and smooth fair finish complete all as specified and directed. Please Enable Macros to View BoQ information |