| 1 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories complete all as specified. |
| 2 | Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified. |
| 3 | Demolition of cement concrete (reinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified. |
| 4 | Demolition of Brickwork or stone/boulder masonry, built in lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles in cement or cement lime mortar complete all as specified. |
| 5 | Taking down cement or cement lime plaster, any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified. |
| 6 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including nsinital or similar pattern roof coverings complete all as specified. |
| 7 | Dismantling Stone slabs, Interlocking tiles Laid bedded and pointed in any mortarand tiles of any description or thickness in floors, aprons etc complete all as specified. |
| 8 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified. |
| 9 | Dismantling expanded metal, any thickness or mesh, chain link fencing fixed with steel or wood fillets, if any N exc 4kg/Sqm Complete all as specified and directed |
| 10 | M&L for Preparing old steel & iron surfaces of any description over 10 cm in width or girth and applying one coats of synthetic enamel paint complete all as specified. |
| 11 | M&L for Preparing old Puff Panel surfaces of any description over 10 cm in width or girth and applying one coats of synthetic enamel paint complete all as specified. |
| 12 | M&L for Preparing old steel & iron surfaces plain or moulded, n.exe 10 cm width or girth and applying one coat of synthetic enamel paint when unconnected with other painting or when painted in a different tint complete all as specified. |
| 13 | M&L for Brick work with sub class ‘B’ old size bricks, straight or curved on plan exceeding 6 m mean radius, built in cement mortar 1:6 complete all as specified. |
| 14 | M&L for Except brick in brickwork with subclass `B` bricks, in straight or curved on plan exc 6m mean radius, built in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge Note :- Brick is obatined from the Demolotion item |
| 15 | M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4. |
| 16 | M&L Rendering 10 mm thick in cement mortar 1:6 on faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified. |
| 17 | M&L Rendering 5 mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished fair & even complete all as specified. |
| 18 | M&L Rendering 15 mm thick in cement mortar 1:4 on faces of brick work or concrete surfaces, mixed with water proofing compound @ 2% by weight of cement, finished fair and even complete all as specified and directed. Note : WPC shall be measured and paid in respective items of Sch 'A' (BOQ). |
| 19 | Supply only water proofing compound, complete all as specified and directed. |
| 20 | M & L for complete removal of existing treatment and applying two coats exterior emulsion weather proof paint over one coat of exterior wall primer incl. preparation of surfaces of old decorated walls etc, properly making of v shape crakes and filling of all crakes with crakes seal of walls complete all as specified and directed by Engr-in-charge. |
| 21 | M& L for complete removal of existing treatment in wall surface and applying two coat, of Oil bound distemper over 2mm thick birla white putty including preparation of surface complete all as specified. |
| 22 | M&L for Preparing new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper in approved colour/shade over a coat of chalk whiting primer after preparation of surfaces complete all specified. |
| 23 | M&L for Preparing new plastered or unplastered surfaces of ceiling and applying two coats of white wash complete all as specified. |
| 24 | M & L for Preparing new plastered or unplastered surfacest and applying two coats exterior emulsion weather proof paint over one coat of exterior wall primer incl. preparation of surfaces of old decorated walls etc, properly making of v shape crakes and filling of all crakes with crakes seal of walls complete all as specified and directed by Engr-in-charge. |
| 25 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall , fixed with self screws or 'J'/'L' hook complete all as specified. |
| 26 | S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwes or 'J'/'L' hook Upto a height of 10 mtrs as specified complete all as specified. |
| 27 | S&F 50mm pre-painted galvalume PUF insulated panel aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall , fixed with self screws or 'J'/'L' hook complete all as specified. |
| 28 | S&F for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified. |
| 29 | S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces,Ms Sheet and MS plates etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified. |
| 30 | S&F Joist, channel, angle, or tee sections, fixed independently, in water tank stagging, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) Fe-410- W(Gde E-250) quality B complete all as specified. |
| 31 | M & L for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe-410- W(Gde E-250) quality B complete all as specified. |
| 32 | S& F in repair Bird Spikes of 304 stainless steel,UV stabilished polycarbonate ,height 11.43 cm and spread width up to 20 cm for roof edges and buliding ledges the installation must be done by cleaning the surface throughly and fixing the base using screws and wall plugs or industrial grade weather-proof adhesive as per the specification. |
| 33 | S& F in repair Bird Spikes of Polycarbonate l,UV stabilished polycarbonate ,height 10.00 cm and spread width up to 20 cm for roof edges and buliding ledges the installation must be done by cleaning the surface throughly and fixing the base using screws and wall plugs or industrial grade weather-proof adhesive as per the specification complete all as specified. |
| 34 | M&L PCC in foundations, filling and mass-concrete type C2 (1:3:6) using 40 mm graded stone aggregate |
| 35 | Supply only Chain link MS galvanised fencing, any size or type complete all as specified and as directed. |
| 36 | Fixing only chain link fencing including line wire any mesh, size and type to any type of standards rails staining bolts etc including provision of binding wire complete all as specified and as directed |
| 37 | S&F Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled & countersunk for balusters running bars, for doors,balusters,nosing to steps including embeding in concrete & screwing etc. wind ties for roof including securing bolts; posts & struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., & similar work conforming to Fe 290-0 Gde E-165 complete all as specified. |
| 38 | S&F Mild steel screw bolts (machine made) with hexagonal /square heads at one end & screwed the other/ screwed both ends, each screwed end to be fitted with washers & one hexagonal or square nut, length of bolt exc 5cm but n exc 10cm long dia of shank 11 to 15 mm complete all as specified. |
| 39 | M&L for 100mm PCC 1:4:8 type D2 (40mm graded aggregate) as in sub base complete all as specified and directed. |
| 40 | M&L cement concrete work in pavement / hard - standing of flexural strength 40 Kg per sqm cm in field using 400 kg of cement per cubic metre ,thickness of concrete 25cm or less complete all as specified and directed. |
| 41 | M & L Providing, cement concrete (1:2:4) type B-1(using 20 mm graded agg) in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed |
| 42 | M & L Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified. |
| 43 | M&L Providing precast cement concrete 1:2:4 type B-1 Using 20mm graded aggregate in but in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified. |
| 44 | S&F in repair Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings & straining & fixing to any type of standard rails straining bolts, including, securing or tying at crossings with & provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified. |
| 45 | S & F TMT bars 10 mm dia and over, cut to length, bent to shape as required incl cracking bending hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia, complete all as specified and as directed |
| 46 | M&L Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand;complete all as specified. |
| 47 | M&L Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified.. |
| 48 | S&F PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in tranches or in floors or wall (110mm bore) including taking down all as specified. |
| 49 | S&F PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in tranches or in floors or wall (75mm bore) including taking down all as specified. |
| 50 | M & L for preparing bituminous /Conrete surfaces of road and marking paint of approved colour apllting two coat of water based over a coat of primer (Conforming to IS-164-1981) White or Yellow exc 10 Cms width using automatic mechanical nozzle spray machine complete all as specified and directed |
| 51 | M&L PCC in surface channels and drains type B2 (1:2:4) using 12.50 mm graded stone aggregate complete all as specified and directed. |
| 52 | M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped end etc. complete all as specified and directed. |
| 53 | Cleaning of Mud/Unwanted Vegitation from drain to plastering and PCC in Foundation and forming fair finished of drain or channel complete all as specified and dirested. |
| 54 | M & L Walling of random rubble, uncoursed , well bonded, bedded and solidly hearted, built in CM 1:4 complete all as specified. |
| 55 | M&L Raised pointing to random or polygonal rubble, un coursed or brought upto courses complete all as specified. |
| 56 | Notes :- Amount of Credit Schedule for Schedule 'A' Part-ll shall be deducted from total quoted amount of BOQ to arrive at the contract sum. Please Enable Macros to View BoQ information |