| Sl. No. | Item Description |
| 1 | PART A Civil works (1.001 to 1.065) |
| 2 | Surface dressing of ground including removing vegetation in equalities not exceeding 15 cm deep and disposal of rubbish lead upto 50 m and lift upto 1.5 m. |
| 3 | Providing detailed layout plan of area in scale 1:500 including carrying out contour survey and detailed Engineering plane table Survey with the help of 24' Alidade. The dolomite area measurement of the plot and structures, trees, over head line and under ground service amenities within the area, with triagular method and giving detailes of the structures, such as total area, type of building and distance from all corners taking trial pit 0.5x0.5x2.00 m.-2One Number. per acre and collection of record from city survey / D.I.L.R. authorities and authentication. The plan shall be traced on 75 micron polyster film and shall be submitted along with three Amonia prints. The contour levels shall be marked at 0.5 Meter intervals. Note:- The items includes- 1)Traversing work with theodolite and steel tape. 2) Levelling Grid Work of the terrain. 3)Detailed Engineering Survey and contouring work of the terrain. 4)Plotting work. 5)Collection of Record. b) Above 1 Acre |
| 4 | Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in :All kinds of soil |
| 5 | Earthwork in by mechanical means (hydraulic excavator)/manual means in foundation pipeline trenches drain (not exceeding 1.5 m in width or 10 sq.m. on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m..All kinds of soil |
| 6 | Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge |
| 7 | Earthwork in by mechanical means (hydraulic excavator)/manual means in foundation pipeline trenches drain (not exceeding 1.5 m in width or 10 sq.m. on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m. All types of Ordinary rock including all types of laterite rock, blasting prohibited |
| 8 | Providing anti – termite treatment to buildings conforming to I.S.S. 6113 part II 1971 (revised) including adopting precautions for health hazards and safety measures as required therein with the cost of all materials, chemicals, plants, equipments required for the treatment and furnishing a guarantee for a minimum period of 10 years from the date of completion including eradicating any infestation of termite free of cost during the guaranty period complete. (The payment will be made on plinth of the building. )-Pre-construction |
| 9 | Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. |
| 10 | Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etccomplete. |
| 11 | Dewatering on BHP basis by using water pump including diversion of stream, providing cofferdams, earthern bunds etc. as may be necessary for foundation and other parts of the the works and pumping out water during and after excavation as may be required by using 3.0 BHP pump etc. complete. (prior approval of Superintending Engineer will be necessary) |
| 12 | Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ ranite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fineaggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) |
| 13 | Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. columns asper detailed designs and drawing or as directed including Steel centering formwork, cover blocks laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface orroughening if special finish is to be provided and curing etc. complete. (Excludingreinforcement and structural steel). with fully automatic micro processor based PLCwith SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Panmixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 14 | Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 15 | Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).withfully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 16 | Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 17 | Providing and laying in situ cement concrete M30 with tremix treatment for 125 mm thickness for flooring with groove cutting of 4mm wide and 10mm deep with necessary refilling with bitumen etc. complete. |
| 18 | Providing and fixing vitrified glossy finished (600x600) and 10mm thick tiles in floor, treads of steps, landing on 25mm thick bed of cement mortar 1:3 and jointed with cement slurry complete. |
| 19 | Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete |
| 20 | Providing and laying in position flooring of telephone black /Amba White / Cat barybrown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. |
| 21 | Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete . Both side polish for urinal |
| 22 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc.with hairline finish, including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 23 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. |
| 24 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete |
| 25 | Providing internal cement plaster 12mm. Thick in Single coats in cement mortar 1:3 with out neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. |
| 26 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Spec . No. Bd. L.7 Page No.369. |
| 27 | Providing and applying interior wall finish luster of approved make on internal wall surface as detailed below Scrapping the surface with emery paper and wipe clean wall primer with brush with mineral turpentine with brush 8 to 10% and oil 15 to 20% with roller and allowing to dry for a period 6 to 8 hours. wall putty with appropriate proportion of water allowing to dry for period 4 to 6 hours. Scrapping with Emery paper 180 and wipe clean. Applyingwall primer with brush with mineral turpentine 8 to 10% and oil 15 to 20% with roller Scrapping Emery paper 320 and wipe clean, interior wall finish luster 1st coat with brush/rubber/spray with mineral turpentine 7 to 9% and Oil with roller 19 to 21% After 8 hours of activity Applying 2nd coat or wall finish Lustre with mineral turpentine 7 to 9 % with brush and Oil with roller 19 to 21% after allowing dry for the period of 6 to 8 hours activity. (With prior approval of S.E.) |
| 28 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Spec. No. Bd.F.17 Page No. 306 |
| 29 | Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed / fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from under side to give smooth, seamless ceiling. The rate should includ enecessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cutouts, painting including labour, material, lifts etc. all complete. |
| 30 | Providing, detailing, and fabricating as per specifications, transporting to site and erecting MS Openable / Sliding / Ornamental Entrance Gates including track and wheel, locking arrangement, fixing bolts, nuts, washers, cleats, stiffeners, gussets decorative balusters, arrow heads etc. and all necessary operations like straightening, bending, cutting, drilling, grinding, machining if specified, welding etc. complete weighing 60 to 65 kg/Sqm, including cleaning, Grinding and removing the welding burr and preparing surface and applying one coat of red oxide zinc chromate primer and one coat of Synthetic Enamel paint after fabrication and second coat of Synthetic Enamel paint after erection, with approved colour, shade and brand etc. including touching up with primer etc. complete as directed by Engineer In Charge |
| 31 | Providing & fixing factory-made Single leaf 2 hour fire rated door as per IS 3614 Part 2 & BS 476 Part 20 & 22, tested to UL 10 C and conforming to NFPA 80 , tested at NTL /CBRI/ARAI of Plain Steel finish type with a.) Frame of size 143x58 mm and thickness of 1.6 mm thick skin pass galvanized iron sheet (Conform to IS 277 ) formed to single or double rebate profile b.) Shutter of 46 mm thickness and constructed from 1.2 mm thick skin pas galvanized iron sheet (Conform to IS 277) infill Rockwool / Mineral wool/ Honey comb craft paper c.) Vision glass of 5mm thick clear/wired glass Circular or Rectangular d.) Finish : Primed with zinc phosphate stoving primer and finished with Polyurethane aliphatic grade or epoxy paint as required of thickness 60 micron e.) Accessories : Min 8 Anchor fastener of HILTI make, min 3 SS Ball Bearing Butt Hinges, Mortise sash lock with lever handle, Mortise dead bolt , Mortise latch , Door closer , Panic bar and external trim lock and Flush bolts complete. |
| 32 | Providing and fixing of factory made uPVC Louver window (White Colour) comprising of uPVC multi-chambered with wall thickness of 2.3mm (+-0.2 mm ), duly reinforced with 1.5 mm thick G. I. Section. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specifie Parameter1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm25 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm26 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 Surface Spread of flame BS : 476 - Part 7 Classification 18 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable9 Tensile modulus ASTM D 638 Shall not be < 35 MPa10 Shear Modulus ASTM D 732 Shall not be < 220 MPa11 Tensile Strength EN ISO 527 Shall not be < 30 MPa. All corners of frame shall be fusion welded. Both vertical sides of the frame, adjustable louver mechanism having one lever or fixed louver bracket shall be fitted with the of 4 mm Frosted Annealed glass. Window will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration,wrapping and rotting under general use.a.Louver Window (Big Series) frame of size 67 x 62 mm & Mullion (if required) of size 67 x 78 mm. |
| 33 | Proving and fixing white vitreous china water closet squatting pan (Indian type w.c. pan) size 580 mm with 100 mm sand cast iron P. or S trap 10 litres high level P.V.C. flushing cister (of approved make) with fittings, rack bolts 32 mm diameter P.V.C telescopic flush pipe with fit tings and clamps 25mm P.V.C. over flow pipe with specials & mosquito proof coupling of approved municipal design and nylon pull complete cutting and making good the walls and floors where required. |
| 34 | Providing and fixing European type white glazed earthenware coupled closet symphonic trap with symphonic low level white glazed 10 litres cistern with black backlite seat with all necessary pipe connection etc. complete. |
| 35 | Providing and fixing white glazed earthenware lipped flat back/corner type Urinal with PVC 5 liters flushing cistern with fittings,inletpipe with stop tap,brackets for fixing the cistern,32mm diameter P.V.C. flush pipe with fitting including lead soil pipe, lead trap and soil pipe connection up to the outside face of wall. |
| 36 | Providing and fixing white glazed earthen ware Wash Hand Basin of 55cm. x 40 cm. size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connections including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete. |
| 37 | Providing and fixing 600 x 450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleats with C. P. brass screws and washers. |
| 38 | Design, Supply, Fabrication, Erection, Testing & Commissioning of Pre-Engineered Steel Building (PEB) including all structural and architectural components as per approved drawings and specifications.The scope shall include: Primary Structure: Built-up steel columns, rafters, and rigid frames fabricated from high-strength steel plates, complete with base plates, stiffeners, and shop-applied primer. Secondary Members: Cold-formed Z/C purlins, girts, eave struts, flange bracings, and sag rods of required thickness and spacing. Mezzanine System: Structural steel framing including beams, joists, columns, and metal decking with provision for a mezzanine floor of approx. 50 sqm. Bracing System: Rod/X-bracing in roof and sidewalls, designed as tension members for stability. Roofing System: 0.47 mm thick bare galvalume roofing sheets fixed with self-drilling fasteners, including ridge, closures, and sealants.Wall Cladding: 0.50 mm thick color-coated profiled sheets for full-height wall cladding including fasteners and sealants.Decking Panels: 0.8 mm thick metal deck sheets for mezzanine slab or platform areas.Accessories: All trims, flashings, facia, gutters, downspouts, canopy soffits, and necessary weather protection systems.Structural Accessories: Anchor bolts, templates, high-strength connection bolts, nuts, washers, and all fixing hardware.Walkways & Access Systems: Staircase, walkways, and cage ladder complete with handrails and safety features.Hot Rolled Steel Members: Pipes, tubes, and miscellaneous supports as required.Gutter System: Valley gutters and rainwater disposal system including downpipes.Surface Treatment: Shop primer and touch-up painting at site.Design Criteria: As per applicable design standards, wind load, seismic zone at MOPA airport Goa, includes EOT crane provision.Structural stability certificate from independent competant third party.Complete Scope Includes:All materials, labor, equipment, tools, transportation, loading/unloading, erection, alignment, bolting, and site completion As Directed By Engineer In Charge. |
| 39 | Providing and fixing colour coated Zincalume (R) AZ150 (min150gms/sq.mt. total on each side) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45mm Base Metal Thickness (BMT) (0.5mm TCT), Hi-strength steel with min. 550MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLOR BOND (R) steel quality super durable polyester paint coat (within organic pigment). The paint shall have a total coating thickness of nominal 35um, comprising of nominal 25um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom.950-1050 mm effective cover width and nominal 25-30mm deep ribs with subtles quarefluting in the five panat nominal 180-250 mm center-to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25um Zinc-Tin alloy coated, Hexhead, self-drilling screw etc. complete. (weight of profile 4.52 kg/sqm) Spec. No. Directed as per engineer incharge (S. S. R. I. No. 38.34 & Page No. 302) |
| 40 | Providing and erecting chain link fencing 1.6 M. height with G.I. chain link of size 50 x 50 mm, 8 gauge thick and fixed 75 mm above ground level on vertical M.S. Angles of 40 x 40 x 6 mm size, includind excavating pits for foundation and embedded in C.C. block of1:4:8 mix of size 450 x 450 x 670 mm. at 1.75 M. c/c with iron bar 16mm dia as hold fast including welding link with angle frame at 30 cm c/c with nuts and bolts and horizontal M.S. Angles at top and bottom of 25 x 25 x 5 mm size and vertical M.S. flat 35 x 5 mmand 25 x 5 mm horizontal including cross support of 40 x 40 x 6 mm angles both side at every corner or bend embedded in concrete blocks of 1:4:8 of size 450 x 450 x 670 mmincluding 3 coats of oil painting etc. complete. |
| 41 | Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. |
| 42 | Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 450mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. |
| 43 | Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 900mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. |
| 44 | Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 1200mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. |
| 45 | RWH - Recharge PitProviding and constructing recharge pit of 2.0m deep and 1.0m dia of pre-cast RCC rings with 6.5\\" dia x 25m deep borewell at the floor of recharge pit including installation of combination of solid/perforated PVC casing pipe wrapped around with netlon mesh including 300mm thick sidefilling around outside of RCC rings (annular space) with 40mm size boulders including filling of recharge pit up to 0.5m depth with 25-75mm clean washed gravels from bottom up followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs, PVC end-caps, fittings etc. including arrangement for inlet & outlet pipe excavation & backfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge. |
| 46 | Providing and laying concrete pipes of I.S. NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.. Spec. No. Bd.V.41, Page No. 573 (S. S. R. I. No. 42.07 & Page No. 351) |
| 47 | Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding boltsand handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (With mechanical gear)BD-T-55 Page No.510 |
| 48 | Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compoundand laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1 Kg per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 31.04 & Page No. 263 |
| 49 | Providing and constructing cast-in-situ reinforced cement concrete (RCC) storm water drainage gutter of size 500 mm (width) × 1000 mm (depth), in specified grade concrete (M20 / as per design), including centering, shuttering, and reinforcement steel as per structural drawings. The work shall include proper bed preparation, laying, compaction, finishing to required slope and alignment for effective drainage, smooth internal finish, and curing.The item also includes necessary formwork, reinforcement, joints, chamfers, inlet/outlet arrangements, connection to down-take pipes / drainage system, and all materials, labour, tools, and equipment required to complete the work.Finished with neat cement mortar / trowel finish to ensure water-tightness. Complete in all respects as per drawings, specifications, and direction of Engineer-in-charge. |
| 50 | Providing and applying epoxy floor coating system of approved make on concrete surface including surface preparation by grinding, application of epoxy primer, intermediate coat and two coats of epoxy top coat applied by roller to achieve total thickness of 300–500 microns |
| 51 | Providing and applying epoxy coving 50 × 50 mm at floor–wall junction using approved epoxy resin system, including surface preparation, primer, application, finishing to smooth curvature, curing, complete. |
| 52 | Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessaryfittings, remaking good the demolished portion etc. complete. Including removing existingpipe line if necessary and conveying and stacking the same in PWD chowky or as directedetc. complete. |
| 53 | Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessaryfittings, remaking good the demolished portion etc. complete. Including removing existingpipe line if necessary and conveying and stacking the same in PWD chowky or as directedetc. complete |
| 54 | Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessaryfittings, remaking good the demolished portion etc. complete. Including removing existingpipe line if necessary and conveying and stacking the same in PWD chowky or as directedetc. complete |
| 55 | Valves & fittings for plumbing works |
| 56 | P.V.C.pipe 160mm dia.Soil Pipe |
| 57 | Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe andwith necessary fixtures and fitting such as bends, tees, single junctions, slotted vent,clamps etc. complete |
| 58 | Providing and fixing 10 cm PVC nahani trap with grating etc. complete. |
| 59 | Providing, laying and fixing P.V.C. pipe of 110 mm. dia. with fittings such as bends,tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete.Including removing existing pipe line if necessary and conveying and stacking thesame in PWD chowky or as directed etc. complete. |
| 60 | Providing and constructing Brick Masonry inspection trap Chamber 90cm x 45cmincluding 1:4:8 C.C foundation, 1:2:4 C.C.channels/half round glazed stoneware pipechannel, salt glazed stone-ware intercepting trap with rodding pipe set in 1:4:8cement concrete block, brick masonry plastering inside and Outside, fixed incement concrete with R.C.C. Cover medium duty 140 Kilogram. etc complete |
| 61 | Providing and fixing H.D.P container one piece moulded water tank made out of lowdensity polythyler and built corrugation including of delivery up to destinationhoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacityabove 1000 to 20,000 litres |
| 62 | 160 mm HDPE SN8 Non-Pressure Underground Sewerage, Drainage & Cross Drainage |
| 63 | P.V.C. 75 mm Soil Pipe 6 Kg/cm2 Pressure |
| 64 | P.V.C. 110 mm Soil Pipe 6 Kg/cm2 Pressure |
| 65 | Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channelshalf round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed incement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete. |
| 66 | Providing complete liaisoning services for obtaining all required statutory approvals, permissions, consents, and clearances from concerned authorities for execution and making the facility fully operational. The scope shall include preparation, submission, follow-up, compliance, and obtaining approvals such as building plan sanction, commencement certificate, occupancy/ completion certificate, Consent to Establish (CTE) and Consent to Operate (CTO) from Maharashtra Pollution Control Board, and permissions/NOCs from Airports Authority of India wherever applicable.Also includes coordination and approvals from statutory/export/agriculture bodies such as APEDA, National Plant Protection Organization, MADA or any other local/state/central authorities as required.The item shall cover documentation, drawings submission, compliance to norms, attending queries, site visits by authorities, and securing all final approvals required for smooth commissioning and operation of the project, complete in all respects.Note:Statutory fees payable to authorities shall be reimbursable at actuals unless specified otherwise. Item includes all coordination, follow-ups, and professional charges. |
| 67 | PART-B PLANT & MACHINERY WORKS (2.001 TO 2.175) |
| 68 | Supply & installation of 80 mm thick Wall Panel (PUF Panel -80 MM-SFPL-DWP-2005) sandwich panel with core material made up of PUF 9002. Manufactured in Continuous line plant with Density 40 +/- 2 Kg/Mt³. Standard width: 1000 mm for Wall and ceiling. |
| 69 | Supply & installation of 120 mm thick Wall Panel (PUF Panel -120 MM-SFPL-DWP-2005) sandwich panel with core material made up of PUF 9002. Manufactured in Continuous line plant with Density 40 +/- 2 Kg/Mt³. Standard width: 1000 mm for Wall and ceiling. |
| 70 | Supply & installationof 120 mm XPS Slab with (two layer) density of 35 Kg/Mt3, Manufactured in continuous line process with density 35 +/- 2 Kg/Mt³ for Slab. |
| 71 | Supply & installation of 75 mm XPS Slab with density of 35 Kg/Mt3, Manufactured in continuous line process with density 35 +/- 2 Kg/Mt³ for Slab. |
| 72 | Supply of Accessories for panel installation including flashings, Si sealant, PUF chemical, screws etc as may required for complete foolproof insulation job |
| 73 | Floor insulation Accessories including bitumin primer, bitumin, polythene sheet vapour barrier, two ply tarfelt etc |
| 74 | Supply of PUF ceiling panel support T section with tie rod 8 mm of required length as per site conditions |
| 75 | Providing fabricationg and erecting in position Structural Steel (channels, angles etc), for insulated roof/wall panel, dock door supports, primary supports at roof level for ACUs , Pre-ccoling chamber ACU support structure, Outdoor unit stands etc. as per approved drawings and specifications and instructions |
| 76 | Supply of Single leaf Manual Hermetically Sealed Horizontal CHILLER Sliding Door with SS-304 Door Profile for negative application uptill 0 degree. PUF Insulation 45 Kg, PPGL sheet on both sides, 80 mm door thickness, for clear opening dimension 1500 mm Width and 2600 mm Height with C-flushing, Wall frame |
| 77 | Supply & installation of Rolling Shutter motorised type 3m x3m - auto |
| 78 | Supply & installation of Hinged Door Single leaf with view ports 1.0m x 2.0 m |
| 79 | Supply & installation of Dock door, vertically moving with motorized movement. The shutter be made of pre-coated steel sandwich panels 40mm thick injected with PUF foam (density 40 ± 2 Kg/m3) & clear opening size as specified. Steel external / internal facing shall have white paint (RAL9002)/ Equivalent. opening size: 3000 mm width x 3000 mm height |
| 80 | Supply & installation of Dock leveler, 6-ton Dynamic Load capacity,Swing Lip system, approx. 400 mm Lip Length, Heavy Duty Rubber Bumper pair, Push Button Operation. Self- supporting base frame, Open and self-cleaning hinge design with platform and lip are made of high-quality tear plate |
| 81 | installtion Dock Shelter: Retractable Type, highly durable curtains made of 3 mm thick wear and tear resistant double layered which is a combination of polyester fibre and PVC top coating. Top projection of 1000 mm, depth 600 mm, Side curtain of 670 mm on both sides. Structure: Aluminium Frame, Fittings and Spring |
| 82 | Supply & installation of PVC strip curtains 3 mm thick, transparent sheets with 40 / 50 mm overlapping and supporting clamps for Door opening size 1.5m x2.6m |
| 83 | Supply & installation of pressure relief ports for cold rooms fermod 2230 / eqvt |
| 84 | Making of cut outs on PUF panels for doors, windows, pipes, cables etc and & finishing it with PUF foam with asthetical manner to the satisfaction of engineer in charge / consultant as per requirement at site |
| 85 | Provide & install a PVC or equivalent sturdy covering flap below the fan section of ACU of Pre-cooling Chambers to ensure proper airflow through the produce. The flap shall have internal and edge reinforcement for adequate support and durability.The flap shall be complete with all fittings and mounting arrangements, and its cost shall be included in the scope. |
| 86 | REFRIGERATION SYSTEM FOR PRE-COOLING CHAMBERS |
| 87 | Air Cooled Condesing Units for Pre-Cooling Chambers Refrigeration systemSupply & installtion of air-cooled condensing unit complete with semi-hermetic compressor working on R407C refrigerant, Air cooled condenser with axial fans, liquid receiver, oil separtor with check valve,Base frame, suction accumulator, safety controls, vibration isolators and accessories. . Suitable for pre-cooling application. Complete in all respects.Capacity: 43.5 KW at 5 deg. C evap. & 40 deg C Ambient Design Temperature: 5 deg. C evap. or (-) 3 deg C evap depending on the product |
| 88 | Supply of ceiling-mounted evaporator unit suitable for Pre-cooling Chambers compatible with R407C DX system complete with Cu cooling coil with Al fins, fans, drain tray, sturdy frame in PPGS, mounting hardware and accessories. Rated capacity: 43.5 kW at 5 deg C Evap & 5 deg C TD Airflow & Coil area suitable for pre-cooling application and shall be able to deliver 85-90% RHOffcycle defrost |
| 89 | Supply & installation refrigeration piping, fittings using seamless copper tubes of refrigeration grade, complete as per approved P&ID. Piping shall be properly supported at maximum 1.5 m spacing using GI supports/rods and routed on suitable cable trays (common trays permitted with approval). Installation shall ensure neat alignment, proper slopes for oil return, and vibration-free operation. Design shall limit pressure drop as per industry standard. All piping shall be cleaned before installation as per standard practices, Rate shall include all supports, fittings, and workmanship, complete in all respects.FOR PRE-COOLING CHAMBERS REFRIGERATION SYSTEM |
| 90 | Refrigeration Valves, controls & Accessories Electronic Expansion valve with required sensors etc. FOR PRE-COOLING CHAMBERS REFRIGERATION SYSTEM |
| 91 | Supply, installation of ISI marked UPVC condensate drain piping laid to nearest drain point with fittings, solvent joints, supports. The drain piping, shall be given proper slope and U-trap per room shall be provided as per standard indutry practice. FOR PRE-COOLING CHAMBERS REFRIGERATION SYSTEM |
| 92 | Supply and installation of suction line insulation using EPDM/XLPE/Nitrile rubber, complete with aluminium foil cladding, finished as per standard practice.25mm thick. FOR PRE-COOLING CHAMBERS REFRIGERATION SYSTEM |
| 93 | Supply, installation of digital temperature & RH indicator complete with sensors, cabling, mounting and all accessories.FOR PRE-COOLING CHAMBERS REFRIGERATION SYSTEM |
| 94 | Supply and charging of R407C refrigerant gas as first charge, complete for system commissioning. FOR PRE-COOLING CHAMBERS REFRIGERATION SYSTEM |
| 95 | Surface preparation and application of primer and two coats of approved paint as per applicablev standards on all equipment, piping and supports, including cleaning, rust removal and finishing.FOR PRE-COOLING CHAMBERS REFRIGERATION SYSTEM |
| 96 | Supply, fabrication, installation, testing and commissioning of electrical control panel as per approved drawings and specifications, complete with incomer (MCCB/MCB/RCBO), motor starters, Outgoing MCB/MCCB,relays etc, protection devices, control MCBs, Electronic expansion valve / room temp. controller with temp display, Condenser fan on/off control on pressure etc. The control panel shall have provision for interlocking of various equipment as per standard practice.FOR PRE-COOLING CHAMBERS REFRIGERATION SYSTEM |
| 97 | Supplying, laying & termination of Power & control cabling for the units as per system requirement and selected as per standard engineering practices.FOR PRE-COOLING CHAMBERS REFRIGERATION SYSTEM |
| 98 | Earthing for the control panel and various motors etc. FOR PRE-COOLING CHAMBERS REFRIGERATION SYSTEM |
| 99 | Supply of Perforated / ladder type trays of required widths (150 mm to 600 mm) made of hot-dip galvanized GI sheet of thickness 1.6–2.5 mm as per size along with all required accessories |
| 100 | Installation, testing and commissioning of system including complete erection, pressure testing, evacuation, refrigerant charging, and making the system fully operational, complete in all respects as per requirement and standard engineering practices, to the satisfaction of the Engineer-in-Charge /consultant. FOR PRE-COOLING CHAMBERS REFRIGERATION SYSTEM |
| 101 | REFRIGERATION SYSTEM FOR COLD ROOM 1 &2 |
| 102 | Air Cooled Condesing Units for COLD ROOM 1 & 2 (2 NOS EACH) Refrigeration systemSupply & installtion of air-cooled condensing unit complete with semi-hermetic compressor working on R404A refrigerant, Air cooled condenser with axial fans, liquid receiver, oil separtor with check valve,Base frame, suction accumulator, safety controls, vibration isolators and accessories. . Suitable for pre-cooling application. Complete in all respects.5 kW at (-)25 deg C Evap. & 40 deg C ambientDesign Temperature: (-)25 deg. C evap. or 5 deg C evap depending on the Whether chamber runs at negetive or postive temp. |
| 103 | Supply of ceiling-mounted evaporator unit suitable for for COLD ROOM 1 & 2 (2 NOS EACH) compatible with R40A DX system complete with Cu cooling coil with Al fins, fans, drain tray, sturdy frame in PPGS, mounting hardware and accessories. Rated capacity: 5kW at (-)25 deg C Evap & 5 deg C TD or min.7.5 kW at 5 deg C evap & 5 deg TDElectric defrost, drain dray insulation & heaters, fan heaters. |
| 104 | Supply & installation refrigeration piping, fittings using seamless copper tubes of refrigeration grade, complete as per approved P&ID. Piping shall be properly supported at maximum 1.5 m spacing using GI supports/rods and routed on suitable cable trays (common trays permitted with approval). Installation shall ensure neat alignment, proper slopes for oil return, and vibration-free operation. Design shall limit pressure drop as per industry standard. All piping shall be cleaned before installation as per standard practices, Rate shall include all supports, fittings, and workmanship, complete in all respects.For COLD ROOM 1 & 2 Refrigeration system |
| 105 | Refrigeration Valves,controls & Accessories including Solenoid valve, filter drier, sight glass, Electronic Expansion valve with required sensors etc.For COLD ROOM 1 & 2 Refrigeration system |
| 106 | Supply, installation of GI inside chamber/ UPVC outside chamber condensate drain piping laid to nearest drain point with fittings, solvent joints, supports. The drain piping, shall be given proper slope and U-trap per room shall be provided as per standard indutry practice. Drain piping inside chamber shall provided with heat tracer. For COLD ROOM 1 & 2 Refrigeration system |
| 107 | Supply and installation of suction line insulation using EPDM/XLPE/Nitrile rubber, complete with aluminium foil cladding, finished as per standard practice.75 mm thick. or COLD ROOM 1 & 2 Refrigeration system |
| 108 | Supply, installation of digital temperature & RH indicator complete with sensors, cabling, mounting and all accessories.For COLD ROOM 1 & 2 Refrigeration system |
| 109 | Supply and charging of R404A refrigerant gas as first charge, complete for system commissioning.For COLD ROOM 1 & 2 Refrigeration system |
| 110 | Surface preparation and application of primer and two coats of approved paint as per applicablev standards on all equipment, piping and supports, including cleaning, rust removal and finishing.For COLD ROOM 1 & 2 Refrigeration system |
| 111 | Supply, fabrication, installation, testing and commissioning of electrical control panel as per approved drawings and specifications, complete with incomer (MCCB/MCB/RCBO), motor starters, Outgoing MCB/MCCB,relays etc, protection devices, control MCBs, Electronic expansion valve / room temp. controller with temp display, Defrost Controller, Condenser fan on/off control on pressure etc. The control panel shall have provision for interlocking of various equipment as per standard practice.For COLD ROOM 1 & 2 Refrigeration system |
| 112 | Supplying, laying & termination of Power & control cabling for the units, heaters etc as per system requirement and selected as per standard engineering practices.For COLD ROOM 1 & 2 Refrigeration system |
| 113 | Earthing for the control panel and various motors etc. For COLD ROOM 1 & 2 Refrigeration system |
| 114 | Supply of Perforated / ladder type trays of required widths (150 mm to 600 mm) made of hot-dip galvanized GI sheet of thickness 1.6–2.5 mm as per size along with all required accessories For COLD ROOM 1 & 2 Refrigeration system |
| 115 | Installation, testing and commissioning of a system, including complete erection, pressure testing, evacuation, refrigerant charging, and making the system fully operational, complete in all respects as per requirement and standard engineering practices, to the satisfaction of the Engineer-in-Charge /consultant. For COLD ROOM 1 & 2 Refrigeration system |
| 116 | COLD ROOM 3 ( POSITIVE TEMP ONLY) |
| 117 | Air Cooled Condesing Units for COLD ROOM-3 Refrigeration systemSupply & installtion of air-cooled condensing unit complete with semi-hermetic compressor working on R407C refrigerant, Air cooled condenser with axial fans, liquid receiver, oil separtor with check valve,Base frame, suction accumulator, safety controls, vibration isolators and accessories. . Suitable for pre-cooling application. Complete in all respects.Capacity: 10 kW at (-)3 deg C Evap & 40 deg C ambientDesign Temperature: 5 deg. C evap. or (-) 3 deg C evap depending on the product |
| 118 | Supply of ceiling-mounted evaporator unit COLD ROOM-3 compatible with R407C DX system complete with Cu cooling coil with Al fins, fans, drain tray, sturdy frame in PPGS, mounting hardware and accessories. Rated capacity: 43.5 kW at 5 deg C Evap & 5 deg C TDAirflow & Coil area suitable for Cold room for fresh products application and shall be able to deliver 85-90% RH, Offcycle defrost |
| 119 | Supply & installation refrigeration piping, fittings using seamless copper tubes of refrigeration grade, complete as per approved P&ID. Piping shall be properly supported at maximum 1.5 m spacing using GI supports/rods and routed on suitable cable trays (common trays permitted with approval). Installation shall ensure neat alignment, proper slopes for oil return, and vibration-free operation. Design shall limit pressure drop as per industry standard. All piping shall be cleaned before installation as per standard practices, Rate shall include all supports, fittings, and workmanship, complete in all respects.FOR COLD ROOM-3 REFRIGERATION SYSTEM |
| 120 | Refrigeration Valves,controls & Accessories Thermostatic expansion valve etc.FOR COLD ROOM-3 REFRIGERATION SYSTEM |
| 121 | Supply, installation of ISI marked UPVC condensate drain piping laid to nearest drain point with fittings, solvent joints, supports. The drain piping, shall be given proper slope and U-trap per room shall be provided as per standard indutry practice. FOR COLD ROOM-3 REFRIGERATION SYSTEM |
| 122 | Supply and installation of suction line insulation using EPDM/XLPE/Nitrile rubber, complete with aluminium foil cladding, finished as per standard practice.25mm thick. FOR COLD ROOM-3 REFRIGERATION SYSTEM |
| 123 | Supply, installation of digital temperature & RH indicator complete with sensors, cabling, mounting and all accessories.FOR COLD ROOM-3 REFRIGERATION SYSTEM |
| 124 | Supply and charging of R407C refrigerant gas as first charge, complete for system commissioning.FOR COLD ROOM-3 REFRIGERATION SYSTEM |
| 125 | Surface preparation and application of primer and two coats of approved paint as per applicablev standards on all equipment, piping and supports, including cleaning, rust removal and finishing.FOR COLD ROOM-3 REFRIGERATION SYSTEM |
| 126 | Supply, fabrication, installation, testing and commissioning of electrical control panel as per approved drawings and specifications, complete with incomer (MCCB/MCB/RCBO), motor starters, Outgoing MCB/MCCB,relays etc, protection devices, control MCBs, Electronic expansion valve / room temp. controller with temp display, Condenser fan on/off control on pressure etc. The control panel shall have provision for interlocking of various equipment as per standard practice.FOR COLD ROOM-3 REFRIGERATION SYSTEM |
| 127 | Supplying, laying & termination of Power & control cabling for the units as per system requirement and selected as per standard engineering practices.FOR PRE-COOLING CHAMBERS REFRIGERATION SYSTEM |
| 128 | Earthing for the control panel and various motors etc. FOR COLD ROOM-3 REFRIGERATION SYSTEM |
| 129 | Supply of Perforated / ladder type trays of required widths (150 mm to 600 mm) made of hot-dip galvanized GI sheet of thickness 1.6–2.5 mm as per size along with all required accessories FOR COLD ROOM-3 REFRIGERATION SYSTEM |
| 130 | Installation, testing and commissioning of system including complete erection, pressure testing, evacuation, refrigerant charging, and making the system fully operational, complete in all respects as per requirement and standard engineering practices, to the satisfaction of the Engineer-in-Charge /consultant. FOR COLD ROOM-3 REFRIGERATION SYSTEM |
| 131 | REFRIGERATION SYSTEM FOR ANTE-ROOM 1 & 2 AND DOCK AREA |
| 132 | Air Cooled Condesing Units for ANTE-ROOM 1 Refrigeration systemSupply & installtion of air-cooled condensing unit complete with scroll compressor working on R407C refrigerant, Air cooled condenser with axial fans and all accessories Complete in all respects. Capacity: 17 kW at 2 deg C Evap & 40 deg C ambient |
| 133 | Air Cooled Condesing Units for ANTE-ROOM 2 Refrigeration systemSupply & installtion of air-cooled condensing unit complete with scroll compressor working on R407C refrigerant, Air cooled condenser with axial fans and all accessories Complete in all respects.Capacity: 11 kW at 2 deg C Evap & 40 deg C ambient |
| 134 | Air Cooled Condesing Units for Dispatch Dock Refrigeration systemSupply & installtion of air-cooled condensing unit complete with scroll compressor working on R407C refrigerant, Air cooled condenser with axial fans and all accessories Complete in all respects.Capacity: 7.5 kW at 2 deg C Evap & 40 deg C ambient |
| 135 | Supply of ceiling-mounted evaporator unit Ante-room-1 compatible with R407C DX system complete with Cu cooling coil with Al fins, fans, drain tray, sturdy frame in PPGS, mounting hardware and accessories. Rated capacity: 17.5 kW at 2 deg C Evap & 10 deg C TD |
| 136 | Supply of ceiling-mounted evaporator unit Ante-room-2 compatible with R407C DX system complete with Cu cooling coil with Al fins, fans, drain tray, sturdy frame in PPGS, mounting hardware and accessories. Rated capacity: 11 kW at 2 deg C Evap & 10 deg C TD |
| 137 | Supply of ceiling-mounted evaporator unit Ante-room-2 compatible with R407C DX system complete with Cu cooling coil with Al fins, fans, drain tray, sturdy frame in PPGS, mounting hardware and accessories. Rated capacity: 7.5 kW at 2 deg C Evap & 10 deg C TD |
| 138 | Supply & installation refrigeration piping, fittings using seamless copper tubes of refrigeration grade, complete as per approved P&ID. Piping shall be properly supported at maximum 1.5 m spacing using GI supports/rods and routed on suitable cable trays (common trays permitted with approval). Installation shall ensure neat alignment, proper slopes for oil return, and vibration-free operation. Design shall limit pressure drop as per industry standard. All piping shall be cleaned before installation as per standard practices, Rate shall include all supports, fittings, and workmanship, complete in all respects.ANTE-ROOM 1 & 2 AND DOCK AREA REFRIGERATION SYSTEM |
| 139 | Refrigeration Valves,controls & Accessories including Solenoid valve, filter drier, sight glass, Thermostatic expansion valve etc.ANTE-ROOM 1 & 2 AND DOCK AREA REFRIGERATION SYSTEM |
| 140 | Supply, installation of ISI marked UPVC condensate drain piping laid to nearest drain point with fittings, solvent joints, supports. The drain piping, shall be given proper slope and U-trap per room shall be provided as per standard indutry practice. ANTE-ROOM 1 & 2 AND DOCK AREA REFRIGERATION SYSTEM |
| 141 | Supply and installation of suction line insulation using EPDM/XLPE/Nitrile rubber, complete with aluminium foil cladding, finished as per standard practice.19mm thick. ANTE-ROOM 1 & 2 AND DOCK AREA REFRIGERATION SYSTEM |
| 142 | Supply, installation of digital temperature & RH indicator complete with sensors, cabling, mounting and all accessories.ANTE-ROOM 1 & 2 AND DOCK AREA REFRIGERATION SYSTEM |
| 143 | Supply and charging of R407C refrigerant gas as first charge, complete for system commissioning.ANTE-ROOM 1 & 2 AND DOCK AREA REFRIGERATION SYSTEM |
| 144 | Surface preparation and application of primer and two coats of approved paint as per applicablev standards on all equipment, piping and supports, including cleaning, rust removal and finishing.ANTE-ROOM 1 & 2 AND DOCK AREA REFRIGERATION SYSTEM |
| 145 | Supply, fabrication, installation, testing and commissioning of electrical control panel as per approved drawings and specifications, complete with incomer (MCCB/MCB/RCBO), motor starters, Outgoing MCB/MCCB,relays etc, protection devices, control MCBs, room temp. controller with temp display etc. The control panel shall have provision for interlocking of various equipment as per standard practice.ANTE-ROOM 1 & 2 AND DOCK AREA REFRIGERATION SYSTEM |
| 146 | Supplying, laying & termination of Power & control cabling for the units as per system requirement and selected as per standard engineering practices.ANTE-ROOM 1 & 2 AND DOCK AREA REFRIGERATION SYSTEM |
| 147 | Earthing for the control panel and various motors etc. ANTE-ROOM 1 & 2 AND DOCK AREA REFRIGERATION SYSTEM |
| 148 | Supply of Perforated / ladder type trays of required widths (150 mm to 600 mm) made of hot-dip galvanized GI sheet of thickness 1.6–2.5 mm as per size along with all required accessories ANTE-ROOM 1 & 2 AND DOCK AREA REFRIGERATION SYSTEM |
| 149 | Installation, testing and commissioning of system including complete erection, pressure testing, evacuation, refrigerant charging, and making the system fully operational, complete in all respects as per requirement and standard engineering practices, to the satisfaction of the Engineer-in-Charge /consultant. ANTE-ROOM 1 & 2 AND DOCK AREA REFRIGERATION SYSTEM |
| 150 | REFRIGERATION SYSTEM FOR VEGETABLE PACKHOUSE & PACKING AREA |
| 151 | Air Cooled Condesing Units for VEGETABLE PACKHOUSE Refrigeration systemSupply & installtion of air-cooled condensing unit complete with scroll compressor working on R407C refrigerant, Air cooled condenser with axial fans and all accessories Complete in all respects.Capacity: 17 kW at 6 deg C Evap & 40 deg C ambient |
| 152 | Air Cooled Condesing Units for PACKING AREA Refrigeration systemSupply & installtion of air-cooled condensing unit complete with scroll compressor working on R407C refrigerant, Air cooled condenser with axial fans and all accessories Complete in all respects.Capacity: 20 kW at 6 deg C Evap & 40 deg C ambient |
| 153 | Supply of ceiling-mounted evaporator preferabally dual discharge type for unit VEGETABLE PACKHOUSE compatible with R407C DX system complete with Cu cooling coil with Al fins, fans, drain tray, sturdy frame in PPGS, mounting hardware and accessories. Rated capacity: 17 kW at 6 deg C Evap & 10 deg C TD |
| 154 | Supply of ceiling-mounted evaporator unit preferabally dual discharge type for PACKING AREA compatible with R407C DX system complete with Cu cooling coil with Al fins, fans, drain tray, sturdy frame in PPGS, mounting hardware and accessories. Rated capacity: 20 kW at 6 deg C Evap & 10 deg C TD |
| 155 | Supply & installation refrigeration piping, fittings using seamless copper tubes of refrigeration grade, complete as per approved P&ID. Piping shall be properly supported at maximum 1.5 m spacing using GI supports/rods and routed on suitable cable trays (common trays permitted with approval). Installation shall ensure neat alignment, proper slopes for oil return, and vibration-free operation. Design shall limit pressure drop as per industry standard. All piping shall be cleaned before installation as per standard practices, Rate shall include all supports, fittings, and workmanship, complete in all respects.VEGETABLE PACKHOUSE & PACKING AREA |
| 156 | Refrigeration Valves,controls & Accessories including Solenoid valve, filter drier, sight glass, Thermostatic expansion valve etc. VEGETABLE PACKHOUSE & PACKING AREA |
| 157 | Supply, installation of ISI marked UPVC condensate drain piping laid to nearest drain point with fittings, solvent joints, supports. The drain piping, shall be given proper slope and U-trap per room shall be provided as per standard indutry practice.VEGETABLE PACKHOUSE & PACKING AREA |
| 158 | Supply and installation of suction line insulation using EPDM/XLPE/Nitrile rubber, complete with aluminium foil cladding, finished as per standard practice.19mm thick. VEGETABLE PACKHOUSE & PACKING AREA |
| 159 | Supply, installation of digital temperature indicator complete with sensors, cabling, mounting and all accessories.VEGETABLE PACKHOUSE & PACKING AREA |
| 160 | Supply and charging of R407C refrigerant gas as first charge, complete for system commissioning.VEGETABLE PACKHOUSE & PACKING AREA |
| 161 | Surface preparation and application of primer and two coats of approved paint as per applicablev standards on all equipment, piping and supports, including cleaning, rust removal and finishing.VEGETABLE PACKHOUSE & PACKING AREA |
| 162 | Supply, fabrication, installation, testing and commissioning of electrical control panel as per approved drawings and specifications, complete with incomer (MCCB/MCB/RCBO), motor starters, Outgoing MCB/MCCB,relays etc, protection devices, control MCBs, room temp. controller with temp display etc. The control panel shall have provision for interlocking of various equipment as per standard practice.VEGETABLE PACKHOUSE & PACKING AREA |
| 163 | Supplying, laying & termination of Power & control cabling for the units as per system requirement and selected as per standard engineering practices.ANTE-ROOM 1 & 2 AND DOCK AREA REFRIGERATION SYSTEM |
| 164 | Earthing for the control panel and various motors etc. VEGETABLE PACKHOUSE & PACKING AREA |
| 165 | Supply of Perforated / ladder type trays of required widths (150 mm to 600 mm) made of hot-dip galvanized GI sheet of thickness 1.6–2.5 mm as per size along with all required accessories VEGETABLE PACKHOUSE & PACKING AREA |
| 166 | Installation, testing and commissioning of system including complete erection, pressure testing, evacuation, refrigerant charging, and making the system fully operational, complete in all respects as per requirement and standard engineering practices, to the satisfaction of the Engineer-in-Charge /consultant. VEGETABLE PACKHOUSE & PACKING AREA |
| 167 | REFRIGERATION SYSTEM FOR POST COOLING CHAMBER |
| 168 | Air Cooled Condesing Units for POST COOLING CHAMBER Refrigeration systemSupply & installtion of air-cooled condensing unit complete with scroll compressor working on R407C refrigerant, Air cooled condenser with axial fans and all accessories Complete in all respects.Capacity: 17 kW at 6 deg C Evap & 40 deg C ambient |
| 169 | Supply of ceiling-mounted evaporator unit for POST COOLING CHAMBER compatible with R407C DX system complete with Cu cooling coil with Al fins, fans, drain tray, sturdy frame in PPGS, mounting hardware and accessories. Rated capacity: 17 kW at 0 deg C Evap & 10 deg C TD |
| 170 | Supply & installation refrigeration piping, fittings using seamless copper tubes of refrigeration grade, complete as per approved P&ID. Piping shall be properly supported at maximum 1.5 m spacing using GI supports/rods and routed on suitable cable trays (common trays permitted with approval). Installation shall ensure neat alignment, proper slopes for oil return, and vibration-free operation. Design shall limit pressure drop as per industry standard. All piping shall be cleaned before installation as per standard practices, Rate shall include all supports, fittings, and workmanship, complete in all respects.for POST COOLING CHAMBER |
| 171 | Refrigeration Valves,controls & Accessories including Solenoid valve, filter drier, sight glass, Thermostatic expansion valve etc. for POST COOLING CHAMBER |
| 172 | Supply, installation of ISI marked UPVC condensate drain piping laid to nearest drain point with fittings, solvent joints, supports. The drain piping, shall be given proper slope and U-trap per room shall be provided as per standard indutry practice.for POST COOLING CHAMBER |
| 173 | Supply and installation of suction line insulation using EPDM/XLPE/Nitrile rubber, complete with aluminium foil cladding, finished as per standard practice.19mm thick. for POST COOLING CHAMBER |
| 174 | Supply, installation of digital temperature indicator complete with sensors, cabling, mounting and all accessories.for POST COOLING CHAMBER |
| 175 | Supply and charging of R407C refrigerant gas as first charge, complete for system commissioning.for POST COOLING CHAMBER |
| 176 | Surface preparation and application of primer and two coats of approved paint as per applicablev standards on all equipment, piping and supports, including cleaning, rust removal and finishing.for POST COOLING CHAMBER |
| 177 | Supply, fabrication, installation, testing and commissioning of electrical control panel as per approved drawings and specifications, complete with incomer (MCCB/MCB/RCBO), motor starters, Outgoing MCB/MCCB,relays etc, protection devices, control MCBs, room temp. controller with temp display etc. The control panel shall have provision for interlocking of various equipment as per standard practice.for POST COOLING CHAMBER |
| 178 | Supplying, laying & termination of Power & control cabling for the units as per system requirement and selected as per standard engineering practices.for POST COOLING CHAMBER |
| 179 | Earthing for the control panel and various motors etc. for POST COOLING CHAMBER |
| 180 | Supply of Perforated / ladder type trays of required widths (150 mm to 600 mm) made of hot-dip galvanized GI sheet of thickness 1.6–2.5 mm as per size along with all required accessories for POST COOLING CHAMBER |
| 181 | Installation, testing and commissioning of system including complete erection, pressure testing, evacuation, refrigerant charging, and making the system fully operational, complete in all respects as per requirement and standard engineering practices, to the satisfaction of the Engineer-in-Charge /consultant. for POST COOLING CHAMBER |
| 182 | Humidification system for pre-cooling chambers & cold room complete with Industrial type Ultrasonic Humidifier, U-PVC water piping humidistats etc. to maintain the relative humidity in the design rangeHumidifier Capacity: 3 Lit/hr. |
| 183 | Post-Harvest Handling & Processing Machinery for Fruit & Vegetables |
| 184 | Hot Water Treatment (HWT) System for Mangoes (NSPM-15 Compliant)Design, supply, installation, testing and commissioning of complete Hot Water Treatment (HWT) system , suitable for quarantine treatment of fresh mango fruits against fruit flies, fully compliant with NSPM-15 guidelines of DPPQS, Govt. of India, and suitable for certification by DPPQS / APEDA, including all equipment, controls, instrumentation, software, safety interlocks and accessories, complete in all respects. ss304 MOC mirror finishScope shall include:1. Hot Water Dipping Tank (Batch Type – Jacuzzi System): Supply and installation of insulated SS 304 hot water dipping tank (approx. 3.0 × 1.5 × 0.81 m), with 2.5 mm inner and 1.5 mm outer sheet, 50 mm PUF insulation, complete with hygienic food-grade finish and smooth weldsTank Qty: 1 No2. Heating & Temperature Control System: Supply of SS 316L immersion heaters (~33 kW per tank / as per NSPM complience requirement) with PID-based automatic temperature control, operating range 45.0–47.8°C with ±0.3°C accuracy, including tamper-proof, sealable set points and no manual override during treatment, compliant with NSPM-15.3. Water Circulation System: Hot water recirculation system comprising 3 HP circulation pump with SS piping, designed to ensure uniform temperature distribution with variation not exceeding 1°C, with heaters interlocked with pump operation. |
| 185 | 4. Fruit Handling System:Supply of stainless steel fruit cages suitable for 500 Kilogram per batch loading, approximate size 2.5 m × 1.1 m × 0.7 m, fabricated from SS 304 angles and strips, with SS perforated top cover, designed to allow free circulation of hot water on all sides and ensuring fruits remain minimum 100 mm below water level. Flotation prevention grid/barrier included.No of cages 2 Number Supply of food-grade plastic crates (Nilkamal JR 64175 or equivalent) – 40 Number., arranged as 10 crates per layer × 4 layers, suitable for NSPM-15 approved loading limits. [80 crates to be considered in costing PER SET]5. Drainage & Accessories:Each tank provided with 2-inch SS drain connection with SS ball valve, lifting hooks, supports and all required fittings.6. Temperature Measurement, Monitoring & Recording System:– Minimum 5 One Number. permanent Pt-100 RTD sensors per tank, SS 316L sheath, installed in lower one-third depth– Pulp sensors – 10 Nos., & Portable Sensors – 10 Nos. Mango Precision tools – 5 Nos. To get the sensor values, sensors are to be connected to desktop and values to be constantly displayed / recorded. Data login with report., accuracy ±0.1°C (as per NPPO requirement)– Certified glass mercury reference thermometer, accuracy 0.1°C– 16-channel paperless temperature recorder/data logger, recording interval ≤2 minutes, resolution 0.1°C, USB export, minimum 1-year data retention |
| 186 | 7. Alarm Safety Interlocks & Controls:Audio-visual alarm for treatment cycle completion, interlocks to prevent premature basket removal, heater cut-off on pump failure, over-temperature or power fault, and hoist enablement only after successful completion of approved treatment cycle.8. Control Panel & Power Supply:Industrial control panel with PLC/PID controllers, power and control wiring, cable tray, proper earthing, shock protection, and compliance with applicable electrical safety standards.11. Testing, Calibration & Certification Support:Complete performanance testing, calibration of all sensors and recorders, trial runs, documentation, and assistance during DPPQS / APEDA inspection and certification.Rate to include:All materials, fabrication, erection, instrumentation, wiring, software, calibration, testing, commissioning, training of operators, and all incidental works complete as per specifications and directions of Engineer-in-Charge. |
| 187 | Supply of heating calibration bath suitable for calibration of permanent and portable RTD sensors, temperature range ambient to minimum 60°C, stability/uniformity ±0.1°C, compliant with NSPM-15 Appendix-5 & 6 requirements |
| 188 | PC, Software & Documentation:Industrial PC with UPS, temperature recording and reporting software providing real-time monitoring, graphical and tabular data, PDF report generation, password-protected access, audit trails, data backup and compliance-ready reports for DPPQS/APEDA audits. Laser printer included.- can be made centralised in consultation with client/consultant |
| 189 | Design, supply, fabrication, installation, testing and commissioning of complete overhead electric hoist and transfer system suitable for batch type Hot Water Treatment (HWT) operation for mangoes, for safe lifting, lowering and transfer of fully loaded stainless steel fruit cages, complete in all respects as per specifications and directions of Engineer-in-Charge.Rate to include Cost of hoist Minimum 1.0 MT (or suitable for fully loaded fruit cage including self-weight and safety margin), mono-rail/beam structure, electrical works, interlocks, testing, commissioning, safety devices, consumables, labour, tools and all incidental works complete. |
| 190 | SITC of Mango Hot Water treatment Line Continuous type 2MT/hr capacity as per NSPM 15 requirements. in SS304 construction, mirro finish, complete with (1) Feeding cum sorting inspection Belt Conveyor: 600 mm wide x 2500 mm length approx., SS304 MOC,0.25 HP geared motor. (To feed & sort mangoes for external defects)(2) Washer Unit with detergent washing & Fresh water rinsing: 2500x700 mm wide approx.(4) On- Line Hot Water Treatment Unit as per NSPM 15 requirement :750 mm wide x 4500 mm length approx., SS304 MOC, Flap conveyor: 1 HP geared motor, PVC belt flaps, Roller conveyor: Al rollers powered by 0.25 HP geared motor, monoblock recirculation pump, SS304 piping, adequate temparature sensors.(5) Brusher Unit with Sanitiser application & Wax application : SS304, 700 mm wide x 3500 mm length approx.(6) Dryer Unit: SS304 MOC, 5500 mm length x 1250 mm width approx, Al rollers, 0.25 HP geared motor, 5 HP x4 nos axial fans, 9 kW heaters(7) Belt Singulator: powder coated MS, 3000 mm length x 300 mmwidth approx, PVC belt with0.5 HP geared motor(8) Electronic Grader: MS powder coated, HDPE cups size suitable for all mango variety available and exported from Goa,Maharashtra, Karnataka states.UK imported load cells, min. 4-6 mangos capcity per sec, rotary type iported make solenoids, electrical control panel with complete reporting system.2 HP geared motor.(8) Electrical power & control Panel with power and control cabling, SS cable trays & supports etc as may be reqiredOhter specs as per general specifications attached in the tender. |
| 191 | SORTING / INSPECTION BELT CONVEYOR:M.O.C.: S.S.304.Size: 700 mm (width) x 4000 mm (length) x 1160 mm (height)Conveyor having divider for easily sort the fruits & vegetables.Channel made from sheet in 2 mm thickness.S.S.304 structure of square tube.It will be stands on leveling studs which provide (+/- 50 mm)leveling adjustment.PVC food grade quality inspection belt with white colour.Electrical Drive: 1 H.P. |
| 192 | GRADING BELT CONVEYOR: (BOTH SIDE WORKING TABLE) (MANUAL)M.O.C.: S.S.304.Size: 600 mm (width) x 4000 mm (length) x 1000 mm (Height).Conveyor having divider for easily sort the fruits & vegetables.Channel made from sheet in 2 mm thickness.Table size: 450 mm (1.5') (width) x 900 mm (3') (length) x 1000 mm(Height).Table qty. 6 nos.S.S.304 structure of square tube.Conveyor having 300 mm side working table at both side forgrading.It will be stands on leveling studs which provide (+/- 50 mm)leveling adjustment.PVC food grade quality inspection belt with white colour.Electrical Drive: 1 H.P. |
| 193 | ROLLER CONVEYOR FOR PACKING:Size: 600 mm (Width) x 2500 mm (Length) x 1000 mm (height).Roller dia 51 mm.Every roller mounts at 150 mm pitch with 99 mm gap between tworollers.Roller holding channel construct in 2 mm thickness.Conveyor with end discharge shute at drive end.S.S.304 structure of square tube with level adjustment ball fit.Electrical load: 1 HP |
| 194 | ELECTRICAL CONTROL PANEL FOR ABOVE EQUIPMENTS:Panel construct in S.S.304 material with door.Panel consist V.F.D for inspection conveyor only, starter for all motors with respective H.P., on/off switch, emergency stop button,RYB indicator etc. Power &control wiring, cable trays with supports etc shall be included in the cost |
| 195 | WEIGHING SCALE: FOR PACKED VEGE. WEIGHING |
| 196 | SS packing tables Size: 1.0m(L) x 2.20m(B) x 0.85m (H) Material: SS 304 |
| 197 | SS TrolleySS304 construction with castors. Suitable for movement of plastic crates. |
| 198 | Electronic weighing scale capacity 1000kg accuracy 200gm Platform size 1500*1500mm ms chequred plate Platform heavy duty type |
| 199 | Waste Management bins Nilkamal WB120LGRN / eqvt |
| 200 | PVC Crates of suitable models for F&V handling |
| 201 | Hydraulically Operated Hand Pallet TruckGodrej / Nilkamal / Eqvt, 1500 Kilogram, Nylon / Polyurethane wheels, Suitable for heavy duty operation and long life, |
| 202 | Supply of industrial-grade plastic pallets (HDPE/PP), size 1000 × 1200 mm, injection-moulded, heavy-duty, 4-way entry type suitable for forklift/pallet truck handling. Pallet shall be durable, anti-skid, moisture and chemical resistant. |
| 203 | Platform type Weighing balance Capacity: 100 Kilogram with 10g accuracyFull body in SS construction, , with LED display pole type, Built in battery backup |
| 204 | Water cooler 230/250 V 50 cycles nominal cooling capacity of 80 litres/hr and storage capacity 120 litres with partially stainless steel body complete. specification One Number Blusetar / eqvt approved make |
| 205 | Cartoon straping machine Semi automatic type |
| 206 | MISCELLANEOUS ITEMS |
| 207 | Compay name Board LED |
| 208 | Signages & boards as per industry practice and norms to be put at various locations |
| 209 | Supply & fixing of industrial type fly catcher , suitable mounting arrangment on walls/ceiling as per site requirement. Confirming to CGMP & food safety standards |
| 210 | Rodents boxes |
| 211 | Supply & installtion of split type inverter technology AC 1 TR capacity having minimum BEE 3 star rating suitable to operate on single phase A.C. supply having 1 One Number of air handling unit hi-wall type complete with refrigerant R410A/R32 and copper condenser at position.Necessary refrigerant piping, duly insulated with Nitrile / EPDM insulation power/control wiring between indoor & outdoor unit, mounting stand, and drain piping to be led to the nearest drain point shall be included in the costing. |
| 212 | Supply & installtion of split type inverter technology AC 1.5 TR capacity having minimum BEE 3 star rating suitable to operate on single phase A.C. supply having 1 One Number of air handling unit hi-wall type complete with refrigerant R410A/R32 and copper condenser at position.Necessary refrigerant piping, duly insulated with Nitrile / EPDM insulation power/control wiring between indoor & outdoor unit, mounting stand, and drain piping to be led to the nearest drain point shall be included in the costing. |
| 213 | Supply & installtion of split type inverter technology AC 2 TR capacity having minimum BEE 3 star rating suitable to operate on single phase A.C. supply having 1 One Number of air handling unit hi-wall type complete with refrigerant R410A/R32 and copper condenser at position.Necessary refrigerant piping, duly insulated with Nitrile / EPDM insulation power/control wiring between indoor & outdoor unit, mounting stand, and drain piping to be led to the nearest drain point shall be included in the costing. |
| 214 | Supply & installtion of indutrial type air curtain with necessary mounting arrangement and limit switch based on/off control |
| 215 | Supply & fabrication of support structure (channels/angles/square pipes) in SS304 mirror finish |
| 216 | Oil injected air compressor withI inbuilt dryer , & inbuilt min 500 lit size of air receiver. 7.5 Hp model |
| 217 | Flexible Arm Illuminated Magnifier Model: Lensel Flexible Arm Illuminated Magnifier Deluxe Model with Movable Base (L104DX+L104B) / Eqvt |
| 218 | Binocular research microscope, size: 17*13*9.5, LABLINC /Labline / eqvt approved |
| 219 | Compound Microscope with camera & LED monitor,LABLINC /Labline / eqvt approved make |
| 220 | Vernier caliper DIGITAL 150MM, Electronics india / eqvt approved make |
| 221 | Weighing balance with platform & digial display 30 Kilogram ,least count: 1gm, Electronics india / eqvt approved make WEIGHING BALANCE [FOR LAB USE ONLY] |
| 222 | pH meter DIGITAL, Labtronics / eqvt make |
| 223 | TSS meter(Refractometer) Range 0 to 32°, |
| 224 | Digital hand held TDS meter 0-3000, HM Taiwan / eqvt approved make |
| 225 | Digital multystem Thermometer (pen type) -50 to 300 degree C |
| 226 | Magnifying hand lens (10X) |
| 227 | Temprature Probes to measure temprature of the fruit- Food grade |
| 228 | Penetrometer to measure Pulp pressure - |
| 229 | Exhaust Fans - approx 230 mm dia complete |
| 230 | Exhaust Fans - approx 300 mm dia complete |
| 231 | Exhaust Fans - approx 450 mm dia complete |
| 232 | Supply & installtion of centrifugal cabinet type fan with cabinet suitable for exposed area installtion with 12mm static presure and 20 mivron filter along with starter control panel and power wiring from the point of supply to fan along with earthing etc as per site requirement.For HWT treatment room supply fan: 9500 cmh |
| 233 | Supply & installtion of centrifugal cabinet type fan with cabinet suitable for exposed area installtion with 5 mm static presure and along with starter control panel and power wiring from the point of supply to fan along with earthing etc as per site requirement.For HWT treatment room exhaust fan: 9000 cmh |
| 234 | Supply, erection and testing of air ducting made out of GS sheet of Grade 120 as per latest IS 277 (120 gsm) or higher complete in al respect with necessary support etc22 Gauge (0.8 mm) |
| 235 | Supply, erection and testing of air ducting made out of GS sheet of Grade 120 as per latest IS 277 (120 gsm) or higher complete in al respect with necessary support etc24 Gauge (0.63 mm) |
| 236 | Supply and erection of Exhaust air Grilles in Aluminium construction and with powder coated finish of various sizes to the satisfaction of the owners and architects |
| 237 | Supply and erection of Supply air Grilles with dampers in Aluminium construction and with powder coated finish of various sizes to the satisfaction of the owners and architects |
| 238 | SITC of 3000 LPH RO Water Treatment Plant complete with pre-treatment system, dosing arrangement, RO unit with imported membranes, SS pumps & storage tank, control panel, piping, cabling, and all accessories mounted on skid, suitable for fully automatic operation. |
| 239 | SITC of Pre-fabricated Effluent treatment plant with capacity 25KLD. Source water- Water from vegetable & fruits washing, sewage from toilets. BOD, COD etc shall be considered accordingly. Treated water BOD, COD & other parameters shall be as per state pollution control board requirements. Adequate precaution shall be taken to remove foul odour and color of waste water. The water is expected to reuse for gardening etc.Appropriate technology for ETP shall be considered considering the requirement. |
| 240 | SITC of Pre-fabricated Sewage Treatment Plant (STP) of 3KLD,MBBR type, comprising collection & equalization, aeration/biological treatment, clarification, filtration and disinfection system, complete with pumps, blowers, control panel, interconnecting piping, cabling, and all accessories on skid/compact structure for fully automatic operation and reuse of treated water. |
| 241 | SITC of 500 kg/day Organic Waste Composting Machine (food & fruit waste), fully automatic PLC-based system with SS304 construction, 3-phase power supply, inbuilt odor control system, and automatic temperature/moisture control, capable of 80–90% volume reduction within 24 hours, complete with control panel, accessories, and all necessary fittings for efficient operation. |
| 242 | SITC of cylindrical Water tank/Tanks of various sizes with MOC Zincalume Steel (high corrosion resistant) of Tata BlueScope Make, reinforced inner liner, under liner as per standard and shall be suitable for Fire water tank application. The tank shall have hot dip galvanized external & internal cage ladder,a locakble mahole, roof mounted air ventilator, water level indicator, inlet connection, outlet connection (antivortex type), overflow connection, drain connection with drain valve etc as per the site requirement. The reinforce structure,flanges etc all shal be hot dip galvanized. Tank design to confrm to the relevant standards. Maximum Wind velocity & seismic zone shall be considered as per location of installtion Goa, IndiaThe detailed techncial specifications shall be submitted along with the proposal. |
| 243 | PART-C ELECTRICAL WORKS (3.001 to 3.140) |
| 244 | Metering Kiosk |
| 245 | Supply & Installation, Testing and Commissioning of 11 KV, HT Metering Kiosk , Outdoor type, with CT ratio of 25/5 amp(0.2 to 0.5 accuracy) with 3CTs & 3 PT's and suitable HT TOD Meter , as per Local Power Supply company's approvals and requirements. |
| 246 | Supplying, erecting, testing and commissioning Energy meter suitable for above metering cubical, duly tested from power supply authority |
| 247 | Providing and erecting Heat shrinkable OUTDOORtermination kit for 11 kV ( E ) XLPE HT cable 3X95 OR 3x185 Sq. mm. with necessary material as per specification |
| 248 | Providing and erecting Heat shrinkable INDOORtermination kit for 11 kV ( E ) XLPE HT cable 3x95 OR 3x185 Sq. mm. with necessary material as per specification |
| 249 | Supplying & erecting 3 x 95 OR 3x185 sq.mm 11 kV, XLPE armoured cable on wall/ceiling or laid in trench / pipe in an approved manner as per specification |
| 250 | Providing and erecting Heat shrinkable INDOORtermination kit for 11 kV ( E ) XLPE HT cable 3x95 OR 3x185 Sq. mm. with necessary material as per specification |
| 251 | Providing and erecting Heat shrinkable Touch Proof Joint termination kit for 11 kV ( E ) XLPE HT cable 3x95 OR 3 X 185 Sq. mm. with necessary material as per specification |
| 252 | HT RMU |
| 253 | Supply,Installation,Testing & Commissioning of Sheet Metal Enclosed Outdoor /Indoor as per site condition type 11KV, 630A, 21ka/3 sec, 2 Way,outdor,Non-Extensible SF-6 insulated RMU,comprising 1 Nos. Load break switch as incomer & 1 No. Circuit Breaker. with Earth Switch & Motorised Spring Charged 24V DC supply, mechanical tripping & Closing arrangement. Manufactured as per I.S. / IEC standards switchgears requirements. WITH TOUCH PROOF TERMINATION KIT |
| 254 | Transformer |
| 255 | Supply,Installation & Testing of Outdoor /Indoor as per site condition Type 11 KV/ 433V 400 KVA OLTC ONAN Distribution Transformer (As per IS 1180 Level 2) with Copper Foil winding, delta star connected Indoor type oil cooled transformer, cable termination Box for HV & LV Side,Class A Insulation level, boltless core design, Efficiency as per IS-1180 level 2, all standard accessories like dial type thermometer, breather, rollers, buchholz relay, Surge Arrestor, Marshalling box for interconnection with incomer switch and hooters, First fill of oil, Rating and diagram Plate. Transformer shall be as per Latest IS 1180 Level 2 efficiency. Scope should be consist of Supply of RTCC Panel also.400 KVA Oil Type Indoor) - 11/0.433 KV |
| 256 | INTERNAL ELECTRIFICATION - DB |
| 257 | DISTRIBUTION BOARDSProviding and fixing Lighting/ Power Distribution Boards Flush mounting/ Concealed Type, Double Door type as per approved make and comprising of the following:1. Powder Coated Double Door Type Distribution Board 2. Incoming Breaker.3.Copper Bus Bars4. Outgoing Breakers5. Sub-incomer for RCCB’s (wherever indicated)6. All internal cabling as per specifications. 7. Ferrules for circuits8. Control Chart inside DBAll MCB’s to be of 10 KA Breaking Capacity and RCCB’s of 30mA rating. |
| 258 | LIGHTING DB FLEXI D.B. (LEGRAND MAKE) - 4 ROW 14 MODULEI/C - 40 A FP MCB - 1 No ; 40 A DP RCCB (30mA) - 3 Nos.O/G - 10 A SP MCB - 24 Nos. |
| 259 | 8-WAY TPN D.B.I/C - 40 A FP MCB - 1 No ; 40 A DP RCCB (30mA) - 3 Nos.O/G - 10 A SP MCB - 18 Nos. |
| 260 | UPS DB 4-WAY TPN D.B.I/C - 40 A DP MCB – 1 No, O/G -32 A DP MCB – 2 Nos.40 A DP MCB – 2 Nos. |
| 261 | UPS DB 12-WAY SPN D.B.I/C - 40 A DP RCCB (30mA) - 1 Nos.O/G - 10A SP MCB - 10 Nos. |
| 262 | STREET LIGHT DB6-WAY TPN D.B.I/C - 63 A FP MCB (30mA) – 1 No, O/G -25 A SP MCB – 3 Nos.10 A SP MCB – 15 Nos. |
| 263 | 25 A DP MCB WITH ENCLOUSER |
| 264 | 8-WAY SPN D.B.I/C - 32 A DP RCCB (30mA) - 1 Nos.O/G - 10A SP MCB - 6 Nos |
| 265 | INTERNAL WIRING |
| 266 | POINT WIRING |
| 267 | 1 Light Point controlled by 1 Switch Providing point wiring for 1 light point controlled by Single 6A Switch using 2 X 1.5 X 1.5(E) sq. mm copper conductor PVC insulated FRLS wires in rigid PVC conduits of 25mm and 1.8mm wall thickness ISI mark, concealed in wall & ceiling with necessary boxes/pull boxes complete with 6Amp single pole switch of approved make fixed on concealedmhot dipped GI outlet boxes with earthing screws flushedmwith wall and continuous earthing up to fixture from switch board using 1.0 sq.mm. PVC insulated green color copper earth-wire and terminate the point in angle holder / battenm holder / ceiling rose near the fixtures, including rate of GIbox & white colour poly carbonate front plate for modular Switches. (AVERAGE LENGTH 7 MTR) |
| 268 | 1 Light Point controlled by 1 Switch Providing point wiring for 1 light point controlled by Single 6A Switch using 2 X 1.5 X 1.5(E) sq. mm copper conductor PVC insulated FRLS wires in rigid PVC conduits of 25mm and 1.8mm wall thickness ISI mark, concealed in wall & ceilingwith necessary boxes/pull boxes complete with 6Amp single pole switch of approved make fixed on concealed hot dipped GI outlet boxes with earthing screws flushed with wall and continuous earthing up to fixture from switch board using 1.0 sq.mm. PVC insulated green color copper earth-wire and terminate the point in angle holder / batten holder / ceiling rose near the fixtures, including rate of GI box & white colour poly carbonate front plate for modularSwitches. (AVERAGE LENGTH 7 to 10 MTR) |
| 269 | Secondary Light Point looped using 2 X 1.5 X 1.5(E) sq. mm copper conductor PVCinsulated FRLS wires in rigid PVC conduits of 25mm and1.8mm wall thickness ISI mark, concealed in wall & ceilingwith necessary boxes/pull boxes complete with 6Ampsingle pole switch of approved make fixed on concealedhot dipped GI outlet boxes with earthing screws flushedwith wall and continuous earthing up to fixture from switchboard using 1.0 sq.mm. PVC insulated green color copper earth-wire and terminate the point in angle holder / battenholder / ceiling rose near the fixtures, including rate of GIbox & white colour poly carbonate front plate for modularSwitches. (AVERAGE LENGTH 4 MTR) |
| 270 | Secondary Light Point looped using 2 X 1.5 X 1.5(E) sq. mm copper conductor PVCinsulated FRLS wires in rigid PVC conduits of 25mm and1.8mm wall thickness ISI mark, concealed in wall & ceilingwith necessary boxes/pull boxes complete with 6Ampsingle pole switch of approved make fixed on concealedhot dipped GI outlet boxes with earthing screws flushedwith wall and continuous earthing up to fixture from switchboard using 1.0 sq.mm. PVC insulated green color copper earth-wire and terminate the point in angle holder / battenholder / ceiling rose near the fixtures, including rate of GIbox & white colour poly carbonate front plate for modularSwitches. (AVERAGE LENGTH 4 to 7 MTR) |
| 271 | 1 Fan Point Controlled by 1 SwitchProviding point wiring for 1 fan point controlled by Single 6 Amp Switch using 2 X 1.5 X 1.5(E) sq. mm copper conductor PVCinsulated FRLS wires in rigid PVC conduits of 25mm and1.8mm wall thickness ISI mark, concealed in wall & ceilingwith necessary boxes/ pull boxes, including provision ofFan Box as per specifications complete with 6Amp singlepole switch of approved make fixed on concealed hotdipped GI outlet boxes with earthing screws flushed with wall and continuous earthing up to fixture from switch board using 1.0 sq.mm. PVC insulated green color copper earth-wire and terminate the point in angle holder / batten holder / ceiling rose near the fixtures, including Hum Free (Low noise) 6 Position Step Type Regulator, including rate of GI box & white colour poly carbonate front plate for modular switches. (AVERAGE LENGTH 7 MTR) |
| 272 | 1 Fan Point Controlled by 2 WAY SwitchProviding point wiring for 1 fan point controlled by Single 6 Amp Switch using 2 X 1.5 X 1.5(E) sq. mm copper conductor PVCinsulated FRLS wires in rigid PVC conduits of 25mm and1.8mm wall thickness ISI mark, concealed in wall & ceilingwith necessary boxes/ pull boxes, including provision ofFan Box as per specifications complete with 6Amp singlepole switch of approved make fixed on concealed hotdipped GI outlet boxes with earthing screws flushed with wall and continuous earthing up to fixture from switch board using 1.0 sq.mm. PVC insulated green color copper earth-wire and terminate the point in angle holder / batten holder / ceiling rose near the fixtures, including Hum Free (Low noise) 6 Position Step Type Regulator, including rate of GI box & white colour poly carbonate front plate for modular switches. (AVERAGE LENGTH 7 MTR) |
| 273 | 1 Exhaust Fan Point Controlled by 1 SwitchProviding point wiring for 1 Exhaust fan point with plug nextto window controlled by Single 6 Amp Switch mountedoutside toilet/ main board using 2 X 1.5 X 1.5(E) sq. mm copperconductor PVC insulated FRLS wires in rigid PVC conduitsof 25mm and 1.8mm wall thickness ISI mark, concealed inwall & ceiling with necessary boxes/pull boxes completewith 6Amp singlepole switch of approved make fixed onconcealed hot dipped GI outlet boxes with earthing screwsflushed with wall and continuous earthing up to fixture fromswitch board using 1.0 sq.mm. PVC insulated green colorcopper earth-wire and terminate the point in angle holder /batten holder / ceiling rose near the fixtures including rate ofGI box & white colour poly carbonate front plate for modularSwitches. |
| 274 | 6 Amp Switch Socket mounted on Independent Switchboard Providing point wiring for 1 No. 5 Pin 6 Amp plug point controlled by Single 6 Amp Switch mounted on an independent board using 2 X 1.5 + 1.5 (E) sq. mm copper conductorPVC insulated FRLS wires from main switchboard in rigid PVC conduits of 25mm and 1.8mm wall thickness ISI mark,concealed in wall & ceiling with necessary boxes/pullboxes complete with 6 Amp single pole plug and switch ofapproved make fixed on concealed hot dipped GI outletboxes with earthing screws flushed with wall and continuousearthing up to main switchboard from the plug switch board using 1.5 sq. mm. PVC insulated green color copper earth-wire including rate of GI box & white colour polycarbonate front plate for modular switches. Average length 6 mtr. Excess length will be paid extra in point no C-4 |
| 275 | 2 nos. 6 Amp Socket - below table & 2 nos. 6 Amp Switch + 1no. 6 Amp Socket - above tablemounted on Independent Switchboard Providing point wiring for above point independent board using 2 X 2.5 + 1.5 (E) sq. mm copper conductorPVC insulated FRLS wires from main switchboard in rigid PVC conduits of 25mm and 1.8mm wall thickness ISI mark,concealed in wall & ceiling with necessary boxes/pullboxes complete with 6 Amp single pole plug and switch ofapproved make fixed on concealed hot dipped GI outletboxes with earthing screws flushed with wall and continuousearthing up to main switchboard from the plug switch board using 1.5 sq. mm. PVC insulated green color copper earth-wire including rate of GI box & white colour polycarbonate front plate for modular switches. Submains will be paid extra in point no C-2 |
| 276 | 6 Amp Switch Socket mounted on Lighting/ Power Switchboard (HALF BOARD)Providing point wiring for 1 No. 5 Pin 6 Amp plug pointcontrolled by Single 6 Amp Switch mounted on an mainlighting / power switchboard board using 2 X 2.5 + 1.5 (E) sq. mmcopper conductor PVC insulated FRLS wires, concealed inwall & ceiling with necessary boxes/pull boxes completewith 6 Amp singlepole plug & switch of approved makefixed on concealed hot dipped GI outlet boxes with earthingscrews flushed with wall and continuous earthing up to mainswitchboard from the plug switch board using 1.0 sq. mm.PVC insulated green color copper earth-wire including rateof GI box & white colour poly carbonate front plate formodular switches. |
| 277 | AC Point Providing point wiring for 1 No.16 Amp Heavy Duty Socket/Connector Concealed for Air-Conditioner mounted on an independent switchboard board including 2 X 4.0 + 1 X 2.5 (E) sq. mm copper conductor PVC insulated FRLS wiresin rigid PVC conduits of 25mm and 1.8mm wall thickness ISImark, concealed in wall & ceiling with necessary boxes/pullboxes complete of approved make fixed on concealed hotdipped GI outlet boxes with earthing, screws flushed withwall and continuous earthing up to main switchboard fromthe plug switch board using 2.5 sq.mm. PVC insulatedgreen color copper earth-wire including rate of GI box &white colour poly carbonate front plate for modular switches.Average length 6 mtr. Excess length will be paid extra in point no C-5 |
| 278 | 6/16 Amp Switch Socket Providing point wiring for 1 No.16 Amp plug point controlled by Single 6/16 Amp Switch mounted on an independent switchboard board including 2 X 2.5 + 1 X 1.5 (E)sq. mm copper conductor PVC insulated FRLS wires in rigid PVC conduits of 25mm and 1.8mm wall thickness ISI mark, concealed in In wall & ceiling with necessary boxes/pullnecessary boxes/pull boxes complete with 6/16 Amp single pole plug & switch of approved make fixed on concealed hot dipped GI outlet boxes with earthing screws flushed with wall and continuous earthing using 2.5 sq.mm. PVC insulated green color copper earth-wire including rate of GI box & white colour poly carbonate front plate for modular switches. Average length 6 mtrSubmains will be paid extra in point no C-3 |
| 279 | INTERNAL WIRING - SUBMAINS |
| 280 | Providing sub-Mains Wiring for Lighting Circuit from Distribution Board to Switchboard using 2 X 2.5 + 1 X 1.5 sq. mm copperconductor PVC insulated FRLS wires in rigid PVC conduitsof 25mm and 1.8mm wall thickness ISI mark, concealed inwall & ceiling with necessary boxes/pull boxes completewith continuous earthing up to main switchboard from theDistribution board using 1.5 sq.mm. PVC insulated greencolor copper earth-wire. |
| 281 | Providing sub-Mains Wiring for 6A Socket from Distribution Board to Switchboard using 2 X 2.5 + 1 X 1.5 sq. mm copperconductor PVC insulated FRLS wires in rigid PVC conduitsof 25mm and 1.8mm wall thickness ISI mark, concealed inwall & ceiling with necessary boxes/pull boxes completewith continuous earthing up to main switchboard from theDistribution board using 1.5 sq.mm. PVC insulated greencolor copper earth-wire. |
| 282 | Providing sub-Mains Wiring for Power Circuit from DistributionBoard to Switchboard using 2 X 2.5 + 1 X 1.5 sq. mm copperconductor PVC insulated FRLS wires in rigid PVC conduitsof 25mm and 1.8mm wall thickness ISI mark, concealed in wall& ceiling with necessary boxes/pull boxes complete withcontinuous earthing up to main switchboard from theDistribution board using 1.5sq.mm. PVC insulated greencolor copper earth-wire. (6/16 AMP SOCKETS) |
| 283 | Providing sub-Mains Wiring for 6A Socket from Distribution Board to Switchboard using 2 X 1.5 + 1 X 1.0 sq. mm copperconductor PVC insulated FRLS wires in rigid PVC conduitsof 25mm and 1.8mm wall thickness ISI mark, concealed inwall & ceiling with necessary boxes/pull boxes completewith continuous earthing up to main switchboard from theDistribution board using 1.0 sq.mm. PVC insulated greencolor copper earth-wire. |
| 284 | Providing sub-Mains Wiring for AC Circuit from DistributionBoard to Switchboard using 2 X 4.0 + 1 X 2..5 sq. mm copperconductor PVC insulated FRLS wires in rigid PVC conduitsof 25mm and 1.8mm wall thickness ISI mark, concealed in wall& ceiling with necessary boxes/pull boxes complete withcontinuous earthing up to main switchboard from theDistribution board using 1.5sq.mm. PVC insulated greencolor copper earth-wire. |
| 285 | Empty conduit : Supply and Laying and fixing PRECISION make ISI mark FR PVC conduit with 1.8 mm wall thickness, including all accessories like solid bends, inspection bends, junction boxes, metal boxes etc accessories etc on surface/ recessed and making good to the damage to original finish of following size of conduit for low voltage.25 mm dia conduit |
| 286 | LIGHTING FIXTURES & EXHAUST FAN |
| 287 | Supply,Installation, testing and commissioning of luminaires complete with, lamps, Drivers ,ballast, starter, HPF condenser, standard down rod , connecting cord, The rate shall include all necessary fixing accessories like MS hooks, MS supports, fasteners, with all necessary hardware, accessories as required for complete installation. Note: Catalogue numbers indicated are only to describe type of light fixture required. Lamp Colour shall be - 84 or as approved by Architect / Consultant.Note: All light fittings quantities shall be procured as per Final approved Drawings by architect & approval from client /Architects for sample of each light fittings. |
| 288 | Supplying and erecting LED square / circular Max. 18 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuserhaving system lumens output of Min. 2000 Lumens, min. efficacy of 110lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mountingarrangement with board for surface type or spring loaded mounting clipscomplete with 3 years warranty. |
| 289 | Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty. CSR 2022-23 |
| 290 | Supplying and erecting IP65 and IK08 rated UV shielded polycarbonatewaterproof and dustproof industrial grade LED fitting (4 feet) max. 36Wwith high transitivity diffuser with system lumens output of min. 4300 lumens ,min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 120-270V, surgeprotection of 4 kV, Life class of 50,000 Hrs. at L70B50 , IP20 rated, includingdriver with auto cutoff & auto restart feature at 325V with end caps on PVCBlock/wooden board with 3 years warranty. |
| 291 | 18 watt wall Light |
| 292 | Installation, testing and commissioning of 48\\"/ 52\\"ceiling fan with cover on fan box: Installation, testing and commissioning of ceiling fan, fan box including wiring the down rods of standard length (up to 30cm) with 3X 1.5sq.mm 1.1 kV grade FRLS PVC insulated copper conductor, single core cables including providng and fixing 3mm thick phenolic laminated sheet cover on the fan box etc.as required. |
| 293 | Installation, testing and commissioning of exhaust fan up to 250 mm sweep: Instalaltion of exhaust fan up to 250 mm sweep in exisitng opening, including making the hole to suit the size of the above fan,making good the damage, connection, testing, commissioning etc.as required with bird protective screen. |
| 294 | FOR STREET LIGHT |
| 295 | Supply,Installation and commissioning of 7 MTR. GI Octagonal, Single Arm Street Light Pole. The rate shall include all necessary fixing accessories like MS supports with all necessary hardware, accessories as required for complete installation. Note: Catalogue numbers indicated are only to describe type of light fixture required. Lamp Colour shall be as approved by Architect / Consultant. |
| 296 | Supplying and erecting integrated LED street light fitting 85-90W IP65 & IK08class having single piece pressure die-cast aluminium housing, having systemlumens output of Min. 9300 Lumens, min. efficacy of 110 lumen/W, CRI>70,CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuiltsurge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including drivercomplete with 3 Years warranty as per specification No FG-ODF/FLS2 |
| 297 | UPS /INVERTER SYSTEM |
| 298 | UPS SYSTEM : Supply,Installation and Testing of 10 KVA UPS, Min battery back Up ,Input volts :3 Ph 415 Volts,±10% Output : 1-Phase-230 Volts 4 w 50 Hz ±2%(Dedicated UPS for EMERGENCY LIGHT SYSTEM) Including installation of SMF type batteries to each UPS. |
| 299 | EARTHING SYSTEM |
| 300 | Supply, Installing, Testing and Commissioning Pipe in Pipe type Earthing Rod with 3 meter long Galvanised rod with G.I strip (Mimimum coating shall be 70 Micron on surface) of 50x6 mm for termination, Brick Massionary Chamber etc.required to complete the job. Including Back fill compound of 25 KG,excavation & refilling of Earth pit. |
| 301 | Supply installation of G.I. STRIP 50 X 6 MM |
| 302 | Supply installation of G.I. STRIP 25 X 6 MM |
| 303 | Supply, Installing, Testing and Commissioning Pipe in Pipe type Earthing Rod with 3 meter long Copper Bonded rod with CU strip of 25x6 mm for termination, Brick Massionary Chamber etc.required to complete the job. Including Back fill compound of 25 KG,excavation & refilling of Earth pit. |
| 304 | Supply installation of COPPER STRIP 25 X 6 MM / CABLE |
| 305 | LIGHTENING ARRESTOR WORK |
| 306 | EARLY STREAMER EMISSION LA WORK (ESE)Supply & installation of ESE type LA with Elevation pole, Mounting Mast , Base plate, Mounting bracketClamps all required fixing accessories.supply down conductor of minimum cross sectional area 150 mm2to withstand lightning current. Vendor to approve design from Consultant/Architect/Client. |
| 307 | CABLE TRAYS & ASSOCIATED WORKS |
| 308 | Supply and fixing Hot dip galvanized factory fabricated PERFORATED type cable trays, with Tee, radial bends, threaded rods, supports of cable trays support with special clamp suit to Building PEB structutre etc for the following sizes of cable trays & as per specification.(The GI Coating shall be mimimum 70 micron coating ) |
| 309 | 450 mm x 75x 75 x 2 mm thick |
| 310 | 300 mm x 75x 75 x 2 mm thick |
| 311 | 150 mm x 50 x 50 x 2 mm thick |
| 312 | 50 mm x 50 x 50 x 2 mm thick |
| 313 | CABLES AND CABLE TERMINATIONS |
| 314 | Supply,taking delivery at site, unloading at site,Installation,testing & commisioning of XLPE Insulated, PVC sheathed, armoured, 650/ 1100 V grade power and control cables to be laid in trenches, on cable trays , burried in ground. Civil work for cables to be laid burried in ground such as excavation, backfilling, sand and brick protection and cable tray /tray supports are measured separately and Miscellaneous items such as saddles, clamps, cleats, cable tags/ cable markers etc. are included in the scope |
| 315 | 3.5.C x 300 Sq.mm. A2XFY(XLPE- AL-Armoured) |
| 316 | 3.5.C x 240 Sq.mm. A2XFY(XLPE- AL-Armoured) |
| 317 | 3.5.C x 185 Sq.mm. A2XFY(XLPE- AL-Armoured) |
| 318 | 3.5.C x 150 Sq.mm. A2XFY(XLPE- AL-Armoured) |
| 319 | 3.5.C x 120 Sq.mm. A2XFY(XLPE- AL-Armoured) |
| 320 | 3.5.C x 95 Sq.mm. A2XFY(XLPE- AL-Armoured) |
| 321 | 3.5.C x 50 Sq.mm. A2XFY(XLPE- AL-Armoured) |
| 322 | 3.5C x 35 Sq.mm. A2XFY(XLPE- AL-Armoured) |
| 323 | 3.5C x 25 Sq.mm. A2XFY(XLPE- AL-Armoured) |
| 324 | 4C X 16Sq.mm. A2XFY(XLPE- AL-Armoured) |
| 325 | 3C X 4Sq.mm. 2XWY(XLPE -CU-Armoured) |
| 326 | 3C X 2.5 Sq.mm. 2XWY(XLPE- CU-Armoured) |
| 327 | 4C X 10Sq.mm. 2XWY(XLPE- CU-Armoured) |
| 328 | 4C X 6 Sq.mm. 2XWY(XLPE- CU-Armoured) |
| 329 | 4C X 4Sq.mm. 2XWY(XLPE- CU-Armoured) |
| 330 | LT cable Termination :Supply & installation of Termination of XLPE insulated, PVC sheathed, 650/1100 V grade, armoured cable including stripping of cable insulation, supplying and fixing of Aluminum lugs for Aluminum cable & Copper lugs for copper cable , crimping the same to the conductor, supply and fixing of double compression cable glands with earth tag washer including all 'labour supply and consumable material required for jointing / termination.Note: Aluminium Lugs shall be used for AlLUMINUM Conductor Cables & Tin Copper Lugs for COPPER Cables |
| 331 | 3.5.C x 300 Sq.mm. A2XFY(XLPE- AL-Armoured) |
| 332 | 3.5.C x 240 Sq.mm. A2XFY(XLPE- AL-Armoured) |
| 333 | 3.5.C x 185 Sq.mm. A2XFY(XLPE- AL-Armoured) |
| 334 | 3.5.C x 150 Sq.mm. A2XFY(XLPE- AL-Armoured) |
| 335 | 3.5.C x 120 Sq.mm. A2XFY(XLPE- AL-Armoured) |
| 336 | 3.5.C x 95 Sq.mm. A2XFY(XLPE- AL-Armoured) |
| 337 | 3.5.C x 50 Sq.mm. A2XFY(XLPE- AL-Armoured) |
| 338 | 3.5C x 35 Sq.mm. A2XFY(XLPE- AL-Armoured) |
| 339 | 3.5C x 25 Sq.mm. A2XFY(XLPE- AL-Armoured) |
| 340 | 4C X 16Sq.mm. A2XFY(XLPE- AL-Armoured) |
| 341 | 3C X 4Sq.mm. 2XWY(XLPE -CU-Armoured) |
| 342 | 3C X 2.5 Sq.mm. 2XWY(XLPE- CU-Armoured) |
| 343 | 4C X 10Sq.mm. 2XWY(XLPE- CU-Armoured) |
| 344 | 4C X 6 Sq.mm. 2XWY(XLPE- CU-Armoured) |
| 345 | 4C X 4Sq.mm. 2XWY(XLPE- CU-Armoured) |
| 346 | INDUSTRIAL SOCKET BOARDSupply ,Installation & Testing of Industrial Socket BoardI/C - 32 A,FP MCBO/G - 1 Phase - 1 No Socket3 Phase - 1 No. socketwith metal Distribution Board |
| 347 | TELEPHONE SYSTEMWiring for Telephone PointProviding telephone wiring in standard PVC Conduit of 25mm from telephone tag block on individual floor tosocket out let using CAT 6 cable |
| 348 | Supplying & erecting outdoor type PVC insulated armoured Telephone cables of following pair with 0.5 mm dia, Tinned copper conductor MTNL approved laid on Cable trays in shaft/above false ceiling etc including necessary clamping ,dressing ,identification tag etc.50Pair |
| 349 | Supply installation of Telephone Jack Unit RJ-11 With shutter including concealed modularswitchboard assembly including concealed hot-dipped GIbox and front plates in white color of poly carbonatematerial, necessary wiring etc. |
| 350 | NETWORKING SYSTEM |
| 351 | Supply Installation of NETWORKING Jack Unit RJ-45-CAT 6A-STP With shutter including concealed modularswitchboard assembly including concealed hot-dipped GIbox and front plates in white color of poly carbonatematerial, necessary wiring etc. |
| 352 | Supply & Laying of COMMSCOPE make Unarmoured UTP CAT -6A - REGULAR cable in standard 25 mm PVC conduit from server on individual floor to socket RJ45 outlet including Ferruling. Contractor to give as built drawing as per ferruling. |
| 353 | CCTV SYSTEM |
| 354 | Supply & Installation of Bullet OR Dome camera with CAT 6A cable through 25 mm PVC conduit with all accessories, NVR, rack, display monitor etc as my be required |
| 355 | LT PANEL |
| 356 | LT OUTDOOR TYPE INCOMING-OUTGOING CHANGE-OVER PANEL |
| 357 | Supply Installation, testing and commissioning of following Panels. Panels shall be fabricated out of 16/14 swg CRCA sheet steel, with necessory structural supports in form of structural steel sections. Panels shall be floor mounted.The panel shall be compartmental type with suitable size of bus bar and separate cable and busbarchambers. The cable chambers shall be free from any live open connections. Multifuction meters for all incoming feeders, Indication lamps for all incoming and outgoing feeders for phase identifications and for indication of Switch status.Panel shall be OUTDOOR type. (IP65)FORM (AS PER IEC STANDARDS PROTOTYPE DESIGN BY OEM - NA)14 SWG CRCAALUMINIUM BUS CURRENT DENSITY :- 0.8 AMP/1 SQ. MM.ALL CABLES- INCOMING - BOTTOM / OUTGOING - TOP CABLE ENTRIESAS PER CALCULATION FAULT CURRENT :- 50KAAll panels Switchgear will be provided with lockout tagout (LOTO)arrangement. INDICATIONS POSITIONFOR ALL INCOMERS PHASE INDICATION WITH SWITCH POSITION.FOR ALL OUTGOINGS FOR SWITCH ON INDICATIONPROTECTIONS: SURGE PROTECTION ON INCOMERSINGLE PHASING PREVENTER ON INCOMING BUS FOR PHASE IN BALANCE AND SINGLE PHASE PREVENTIONSSURGE PROTECTION DEVICESMETERINGMULTIFUNCTION METER FOR INCOMING SUPPLY BREAKERS (WITH RS485 PORT)Incoming :- Mains Incomer : 630A 4P MCCB,50 KA,LSIG - 1 no.- MSEDCL400A 4P MCCB,50 KA,LSIG - 1 no.- DG800 A AL.BUSBARCT of 200/5 Amp Class 0.5,10VA for Metering instrument and control 1 SetManual Changeover Switch |
| 358 | LT DISTRIBUTION PANEL - 1Supply Installation, testing and commissioning of following Panels. Panels shall be fabricated out of 16/14 swg CRCA sheet steel, with necessory structural supports in form of structural steel sections. Panels shall be floor mounted.The panel shall be compartmental type with suitable size of bus bar and separate cable and busbarchambers. The cable chambers shall be free from any live open connections. Multifuction meters for all incoming feeders, Indication lamps for all incoming and outgoing feeders for phase identifications and for indication of Switch status.Panel shall be Indoor type.FORM (AS PER IEC STANDARDS PROTOTYPE DESIGN BY OEM - NA)14 SWG CRCAALUMINIUM BUS CURRENT DENSITY :- 0.8 AMP/1 SQ. MM.ALL CABLES- INCOMING - BOTTOM / OUTGOING - TOP CABLE ENTRIESAS PER CALCULATION FAULT CURRENT :- 50KAAll panels Switchgear will be provided with lockout tagout (LOTO)arrangement. INDICATIONS POSITIONFOR ALL INCOMERS PHASE INDICATION WITH SWITCH POSITION.FOR ALL OUTGOINGS FOR SWITCH ON INDICATIONPROTECTIONS: SURGE PROTECTION ON INCOMERSINGLE PHASING PREVENTER ON INCOMING BUS FOR PHASE IN BALANCE AND SINGLE PHASE PREVENTIONSSURGE PROTECTION DEVICES |
| 359 | MULTIFUNCTION METER FOR INCOMING SUPPLY BREAKERS (WITH RS485 PORT)Incoming :-Mains Incomer : 630A 4P ACB,50 KA,LSIG - 1 no.- MSEDCL800 A AL.BUSBARCT of 200/5 Amp Class 0.5,10VA for Metering instrument and control 1 SetProvision for TOD MeterOutgoing :- 320 A, FP, MCCB - 2 NoS. 250 A, FP, MCCB - 3 Nos. 200 A, FP, MCCB - 1 No. 160 A, FP, MCCB - 2 Nos. 125 A, FP, MCCB - 1 No. 40 A, FP, MCCB - 1 No. 63 A, FP, MCB, 10 KA, C-CL - 3 Nos. 63 A, FP, MCB, 10 KA, C-CL - 1 Nos. |
| 360 | 175 KVAR (EFFECTIVE @ 415V) REAL TIME POWER FACTOR CORRECTION PANELINCOMER: 320 A TP MCCB FOR REAL TIME POWER FACTOR CORRECTION PANEL.3 POLE MCCB LSI PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION.OUTGOING: The Switching of Capacitors should be done with the Thyristors.\\"APP\\" Type Capacitors should be used. With suitable voltage (525 volts)7 % Detuned Reactors should added in a circuit to neutralise the Harmonics generated in a circuitSelect Stages in such a way that the Minimum Stage should be 2.5 kVAR and Maximum should be of 100 kVAR (Preferable stages will be 8 Stages but can extend to 12 or 16 Stages per panel manufacturer working)Adequoate Ventilation should be arranged while designing the General Arrangement of Panel. Proper Lowers and Exhaust fans of required CFM should be used.The panel shall be free standing type/ wallmounted type as per relavant drawing and site requirement comprising with the following,Panel should be adhere all the CEIG Guidelines.1. 50 KVAR X 1 NO with 125 A TP MCCB 2. 25 KVAR X 1 NO with 63 A TP MCB 3. 20 KVAR X 3 NOS with 63 A TP MCB 4. 10 KVAR X 2 NOS with 40 A TP MCB 5. 5 KVAR X 4 NOS with 40 A TP MCB 6. 2.5 KVAR X 2 NOS with 32 A TP MCB 6. 40 A TP MCB - 1 SPARE7. 63 A TP MCB - 1 SPARE8. 125 A TP MCCB - 1 SPARE |
| 361 | LT DISTRIBUTION PANEL - 2_PACKING AREAMains Incomer : 200A 4P MCCB,36 KA - 1 no.300 A AL.BUSBARCT of 200/5 Amp Class 0.5,10VA for Metering instrument and control 1 SetOutgoing :- 100 A, FP, MCCB - 1 Nos. 63 A, FP, MCB - 1 No. 40 A, FP, MCB - 6 Nos. 32 A, FP, MCB - 2 Nos 25 A, FP, MCB - 1 No. 25 A, DP, MCB - 1 No. |
| 362 | LT DISTRIBUTION PANEL - 3_NEAR POST COOLING CHAMBER AREAMains Incomer : 250A 4P MCCB,36 KA - 1 no.400 A AL.BUSBARCT of 200/5 Amp Class 0.5,10VA for Metering instrument and control 1 SetOutgoing :- 160 A, FP, MCCB - 1 No. 125 A, FP, MCCB - 1 No. 100 A, FP, MCCB - 3 Nos. 63 A, FP, MCB - 3 Nos. 40 A, FP, MCB - 2 Nos. 25 A, FP, MCB - 3 No.25 A, DP, MCB - 1 No. |
| 363 | LT DISTRIBUTION PANEL - 4_PRE COOLING MACHINE ROOMMains Incomer : 320A 4P MCCB,36 KA - 1 no.500 A AL.BUSBARCT of 200/5 Amp Class 0.5,10VA for Metering instrument and control 1 SetOutgoing :- 100 A, FP, MCCB - 1 No. 63 A, FP, MCCB - 3 Nos. 63 A, FP, MCB - 2 Nos. 40 A, FP, MCB - 7 Nos. 32 A, FP, MCB - 2 No. |
| 364 | LT DISTRIBUTION PANEL - 5_VTPN DB FOR INDUSTRIAL SOCKETMains Incomer : 160A 4P MCCB,25 KA - 1 no.200 A AL.BUSBARCT of 200/5 Amp Class 0.5,10VA for Metering instrument and control 1 SetOutgoing :- 40 A, TP, MCB - 8 Nos. |
| 365 | LT PANEL NO.- 6_FIRE & UTILITY PANELSupply Installation, testing and commissioning Panel. Panels shall be fabricated out of 16/14 swg CRCA sheet steel, with necessory structural supports in form of structural steel sections. Panels shall be floor mounted.The panel shall be compartmental type with suitable size of bus bar and separate cable and busbarchambers. The cable chambers shall be free from any live open connections. Multifuction meters for all incoming feeders, Indication lamps for all incoming and outgoing feeders for phase identifications and for indication of Switch status.Incoming :- Mains Incomer : 250A 4P MCCB,25 KA - 1 no.400 A AL.BUSBARCT of 200/5 Amp Class 0.5,10VA for Metering instrument and control 1 SetOutgoing :- 250 A, FP, MCCB, 25 KA - 1 No. 63 A, FP, MCB, 10 KA, C-CL - 4 Nos. 40 A, FP, MCB, 10 KA, C-CL - 3 Nos. 40 A, DP, MCB, 10 KA, C-CL - 1 No. |
| 366 | Liaisoning Work for Load Sanction from Electricity power supply authority / board & Electrical inspector or any other government authority for sanction of electrical load. Job involves preparation of necessary documents with drawings, as required for load application, submission of document files with necessary officials / departments, follow-up with all concerned departments for getting required load sanctioned, Obtaining work completion report from Electrical inspector & board officials. Successfully charging of entire installation.DG approval Client (Owner) will make all official payments as per the requirement of Electricity board. |
| 367 | Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 having 2 mm thickness up to 3.3 Kv, CSR 2022-23 |
| 368 | Supplying and fixing PVC synthetic elastomer electrically insulating mat with class C insulation conforming to IS: 15652 – 2006 tested having 3mm thickness up to 33 Kv, CSR 2022-23 |
| 369 | Supplying shock proof leather safety shoes of electrical grade of standard size as IS :11226, 14544 duly tested, with necessary test certificate from manufacturer. CSR 2022-23 |
| 370 | Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete CSR 2022-23 |
| 371 | Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working up to 22 kV supply complete. CSR 2022-23 |
| 372 | Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes) CSR 2022-23 |
| 373 | Supplying, erecting, testing and commissioning Diesel Generating Set 250 kVA 3 Phase comprising of Engine 310 BHP @ 1500 RPM coupled with Alternator suitable for continuous duty operations rated at 1500 rpm 415 V, 0.8 PF, 50Hz, 3Ph. , mounted on a Base Frame along with:- Control Panel, Fuel tank, Battery with leads, First fill of oil, Engine safeties & protections, Anti vibration mounting pads, Acoustic Enclosure suitable for 250 kVA DG Set. CPCB IV+ Norms.Cost for Silencer Extension with structural support for the DG Set and Piping as per local norms shall be included. |
| 374 | Supply, Installation, Testing & Commissioning of audio, visual alarm system for cold storage rooms. Job involves solid state Annunciator with hooter & enclosure, installed in occupied area, stay-put type push button station in each cold rooms / pre cooling rooms, cabling from cold rooms / pre cooling rooms to Annunciator. Job involves following items. 8 points Annunciator - 1 NoStay-put type push buttons. - 4 / 8 Nos.2Cx0.75 sq. mm.Copper Flexible multi stranded cable. - 150 Mtrs10Cx0.75 sq. mm.Copper Flexible multi stranded cable. - 150 MtrsJunction box - 10 pair connectionMedium duty PVC conduit of 25 mm size with standard accessories. - 100 Mtrs |
| 375 | Making trench in hard murum/Tar road having 0.9 m depth and minimum 0.3mtr width for laying provided cables of voltage range 3.3 kV to 11 kV complete as per specification No. CW-EXN-CTR CSR 2022-23 |
| 376 | Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete. CSR 2022-23 |
| 377 | Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. CSR 2022-23 |
| 378 | Supplying & laying (including excavation) half round reinforced cement concrete pipe of IS 458:2003 NP-2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. CSR 2022-23 |
| 379 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 200 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. CSR 2022-23 |
| 380 | Making Horizontal Directional Drill / Bore of 150 mm dia and depth up to 1.5 mtr in soft soil and laying 150 mm HDPE/GI pipe etc. complete as per specification no. CW-EXN-CTR, CSR 2022-23 |
| 381 | Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG CSR 2022-23 |
| 382 | Supplying and erecting double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire mesh (jali) complete supported on channel iron, erected in foundation, and painted complete as per specification no SS-AS/DLD, CSR 2022-23 |
| 383 | Supplying and spreading stone metal 25 mm size for 100 mm depth above the ground level complete CSR 2022-23 |
| 384 | PART-D FIREFIGHTING WORKS (4.001 to 4.120) |
| 385 | PUMP HOUSE EQUIPMENT |
| 386 | Supply, Installation, Testing and Commissioning of Electrical Motor Driven Fire Pump Set (Factory Fitted) suitable for automatic operation consisting of the following as per the specifications of fire fighting requirements given in NBC, IS Standards OR LOCAL AUTHORITY APPROVAL:- |
| 387 | Supply, erection, testing & commissioning of Centrifugal Type Horizontal end suction in back-pull-out design, singlestage Single outlet fire pumps with Positive Suction Head having cast iron casing, cast iron diffusers, bronze impellers and dynamically balanced, AISI 304/410 stainless steel shaft running in double ball bearings. Each pump shall be fitted with gland packing and shall be directly coupled on an MS fabricated common base plate to a AC 3 phase, 2900 RPM TEFC EFF-1 motor with adequate number of Anti Vibration Mounting Pads. Each pump shall be capable of delivering a capacity of 2850 LPM at a total head of 88 mtrs. (for Hydrant System) Pump shall be capable of furnishing not less than 150% of rated capacity at a head of not less than 65% of the rated head. The shut off head shall not exceed 120% of rated head. |
| 388 | Supply, erection, testing & commissioning of Centrifugal Type Horizontal end suction singlestage Single outlet fire pumps with Positive Suction Head having cast iron casing, cast iron diffusers, bronze impellers and dynamically balanced, AISI 304/410 stainless steel shaft running in double ball bearings. Each pump shall be fitted with gland packing and shall be directly coupled on an MS fabricated common base plate to a AC 3 phase, 2900 RPM TEFC EFF - 2 motor with adequate number of Anti Vibration Mounting Pads. Each pump shall be capable of delivering a capacity of 2850 LPM at a total head of 88 mtrs. (for Sprinkler System) Pump shall be capable of furnishing not less than 150% of rated capacity at a head of not less than 65% of the rated head. The shut off head shall not exceed 120% of rated head. |
| 389 | Supply, erection, testing & commissioning of Diesel Engine driven (stand by) Centrifugal Type Horizontal end suction singlestage Single outlet fire pumps with Positive Suction Head having cast iron casing, cast iron diffusers, bronze impellers and dynamically balanced, AISI 304/410 stainless steel shaft running in double ball bearings. Each pump shall be fitted with gland packing and shall be directly coupled on an MS fabricated common base plate with adequate number of Anti Vibration Mounting Pads. Radiator cooled, high speed Diesel Engine of suitable B.H.P. running at 2900 RPM. speed including fuel, day oil tank, 12 volts battery with leads, exhaust pipe. The installation shall be complete with necessary pressure gauge with gun metal shut off cock on delivery side etc. Each pump shall be capable of delivering a capacity of 2850 LPM at a total head of 88 mtrs. (for Standby System) Pump shall be capable of furnishing not less than 150% of rated capacity at a head of not less than 65% of the rated head. The shut off head shall not exceed 120% of rated head. |
| 390 | Supply, erection, testing & commissioning of Centrifugal Type Horizontal end suction singlestage Single outlet fire pumps with Positive Suction Head having cast iron casing, cast iron diffusers, bronze impellers and dynamically balanced, AISI 304/410 stainless steel shaft running in double ball bearings. Each pump shall be fitted with gland packing and shall be directly coupled on an MS fabricated common base plate to a AC 3 phase, 2900 RPM TEFC EFF - 2 motor with adequate number of Anti Vibration Mounting Pads. Each pump shall be capable of delivering a capacity of 180 LPM at a total head of 88 mtrs. (for Hydrant & Sprinkler Jockey System) Pump shall be capable of furnishing not less than 150% of rated capacity at a head of not less than 65% of the rated head. The shut off head shall not exceed 120% of rated head. |
| 391 | CONTROL PANEL FOR FIRE PUMPS |
| 392 | Design, manufacture, supply, installation, testing and commissioning of Wall mounted / Floor mounted(including base stand), 415V,3PH, 50Hz extensible and fully compartmentalized panels complying to IS 8623/93. The indoor panels shall be IP 42 and outdoor panels shall be IP 54 type.The Panel shall have proper space with required clearance for cables, incoming / outgoing switchgear, CTs, PTs, ammeter, Voltmeter, selector switches, Insulated and properly supported compartmentalized bus bars with heat shrinkable sleeves along with the other control circuit accessories within the panel and any other electrical component mentioned in the Panel SLD.The panel shall be fabricated out of CRCA not less than 2.0 mm thick for load bearing members and 1.6mm for the doors of LT panel. The Panel shall have seven tank pre treatment process comprising of degreasing, rinsing, de-rusting, rinsing, phosphatising, rinsing and passivation followed by powder coat painting having a paint thickness of 60 microns or as specified.The Panel shall be Dust/Vermin poof. i) Provision shall be made for providing potential free contacts to all pumps starters for connection to building automation system.ii) Provision shall be made for providing Electrical supply for siren Motor with control MCB & toggle switch on front paneliii) All motor MCCB/protecting devices shall be as per TYPE -2 co-ordination iv) Approval of GA drawings/Make of material by client is mandatory prior to fabrication of Panel |
| 393 | Supply, erection, testing & commissioning of Pressure switches of suitable range (20 kg/cm² to 5 kg/cm²) for pump sets. |
| 394 | Supply, erection, testing & commissioning of Pressure gauges of suitable range (0 kg/cm² to 30 kg/cm²) for pump sets with Ball valves, siphon, Fittings like unions / collars / reducers etc. Please Enable Macros to View BoQ information |
| 395 | Supply, erection, testing & commissioning of Pressure gauges of suitable range (0 kg/cm² to 30 kg/cm²) for pump sets with Ball valves, siphon, Fittings like unions / collars / reducers etc. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail