| 1 | Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m in depth for foundations or for laying of cables, fixing of poles, etc and getting out in any type of soil & including removing old serviceable bricks for reuse, etc (if obtained) complete all as specified and as directed. |
| 2 | Returning, filling in trenches including spreading leveling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and directed. |
| 3 | Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed. |
| 4 | M&L for sand filling with approved quality coarse sand for sand cushioning of Under ground cable including spreading and punning down complete all as specified and as directed. NOTE: Punned thickness shall be measured for payment purpose. |
| 5 | Supply and laying burnt brick sub class 'B' best quality laid in trenches for protection of under ground cable complete all as specified and as directed. |
| 6 | M&L for providing plain cement concreate (1:3:6) type C2 (using 40 mm graded stone aggregrates) as in foundations filling, coping for pole and mass concrete filling of trench across the road etc. complete all as specified and as directed. |
| 7 | M&L for cutting existing metal/bituminus road/PCC walk way/any type of tile works n.exc 0.45m width and n.exc 0.90 m in depth including all connected earth work in any type of soil and making good disturbed surfaces matching with the existing specification and finish including disposal of surplus material to a distance n.exc 50m complete all as specified and as directed . |
| 8 | S&F in repairs GI pipe light grade 50mm tubes with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed |
| 9 | S&F in repairs GI pipe light grade 40mm tubes with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed |
| 10 | S&F in repairs High density polyethylene pipes (HDPE) 50mm dia, with pressure 6kgf/cm2 including socket, bends reducersetc fixed complete to walls, ceilings, layed in trenches or in floors etc. complete all as specified and as directed. |
| 11 | Demoltion of PCC of any description and in any position including removal of debris outside MoD land complete all as specified and as directed. |
| 12 | Breaking of PCC coping of any description of poles, taking out unserviceable cable junction box, unserviceable cables including removal of debris outside MoD land complete all as specified and as directed. |
| 13 | M&L for providing plain cement concrete type B1 (1:2:4) using 20mm graded stone aggregrates as in copings, kneelers, columns posts and like etc including watering, slghtly rounded or chamfered angles and throating including necessary form work complete all as specified and as directed. |
| 14 | M&L Brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and as directed. |
| 15 | M&L for 10 mm thick rendering on fair faces of brick works or concrete surface in cement morter (1:4) and finish surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 16 | S&F in repairs On load change over switch, 800 Amps, 415 Volt, 4 pole complete all as specified and as directed. |
| 17 | S&F in repairs On load change over switch 630 Amps 415 Volt 4 pole complete all as specified and as directed. |
| 18 | S&F in repairs On load change over switch 400 Amps 415 Volt 4 pole complete all as specified and as directed. |
| 19 | S&F in repairs On load change over switch 320 Amps 415 Volt 4 pole complete all as specified and as directed. |
| 20 | S&F in repairs On load change over switch 160 Amps 415 Volt 4 pole complete all as specified and as directed. |
| 21 | S&F in repairs MCCB, 63 Amps, 16 KA, 4 Pole type, with fixed magnetic & adjustable (80% - 100%) thermal release including all arranagement for mounting and testing, operating on 415V, 50Hz, AC supply complete all as specified and as directed. |
| 22 | S&F in repairs MCCB, 100 Amps, 25 KA, 4 Pole type, with fixed magnetic & adjustable (80% - 100%) thermal release including all arrnagement for mounting and testing, operating on 415V, 50Hz, AC supply complete all as specified and as directed. |
| 23 | S&F in repairs MCCB, 125 Amps, 25 KA, 4 Pole type, with fixed magnetic & adjustable (80% - 100%) thermal release including all arrnagement for mounting and testing, operating on 415V, 50Hz, AC supply complete all as specified and as directed. |
| 24 | S&F in repairs MCCB, 160 Amps, 25 KA, 4 Pole type, with fixed magnetic & adjustable (80% - 100%) thermal release including all arrnagement for mounting and testing, operating on 415V, 50Hz, AC supply complete all as specified and as directed. |
| 25 | S&F in repairs MCCB 200 Amps, 35 KA breaking capacity, 4 pole with fixed magnetic & adjustable (80% - 100%) thermal release complete all as specified and as directed. |
| 26 | S&F in repairs MCCB 250 Amps capacity 4 pole 35KA breaking capacity with fixed magnetic & adjustable thermal (80% - 100%) thermal release complete all as specified and as directed. |
| 27 | S&F in repairs MCCB 400 Amps capacity 4 pole 36KA breaking capacity with fixed magnetic & adjustable thermal (80% - 100%) thermal release complete all as specified and as directed. |
| 28 | S&F in repairs MCCB 630 Amps capacity 4 pole 50KA breaking capacity with fixed magnetic & adjustable thermal (80% - 100%) thermal release complete all as specified and as directed. |
| 29 | S&F MCCB 800 Amps capacity 4 pole 65KA breaking capacity with fixed magnetic & adjustable thermal (80% - 100%) thermal release complete all as specified and as directed. |
| 30 | S&F in repairs 1100 V grade FRLSH PVC insulated copper cables of size 1.5 sqmm 3 core drawn through street light poles brackes/PVC conduits connecting from the junction box to street light fittings complete all as specified and as directed. |
| 31 | S&F in repairs 1100 V grade FRLSH PVC insulated copper cables of size 2.5 sqmm 3 core drawn through PVC conduits/LDPE pipe/wall/duct etc complete all as specified and as directed. |
| 32 | Disconnecting and taking out old unserviceable LT Under Ground Aluminium cable from Trench / Walls / Ducts and stacking aside complete all as specified and as directed. |
| 33 | Supply and laying under ground, heavy duty, XLPE insulated, armoured, aluminium conductor cable 1100 volts grade, cross-sectional area 10 sq. mm 2 core in trenches / through pipe or bare in road crossing / plingth/ drain/ duct/ floor along pole / wall /ceillings etc complete all as specified and directed.Note:- Earth work, bricks protection & sand cuishioning shall be measured and paid seperately. |
| 34 | All as per BOQ Serial item No 33 above but of size 10 sq. mm 4 core complete all as specified and directed. |
| 35 | All as per BOQ Serial item No 33 above but of size 16 sq. mm 4 core complete all as specified and directed. |
| 36 | All as per BOQ Serial item No 33 above but of size 25 sq. mm 4 core complete all as specified and directed. |
| 37 | All as per BOQ Serial item No 33 above but of size 35 sq. mm 3½ core complete all as specified and directed. |
| 38 | All as per BOQ Serial item No 33 above but of size 50 sq. mm 3½ core complete all as specified and directed. |
| 39 | All as per BOQ Serial item No 33 above but of size 70 sq. mm 3.5 core complete all as specified and directed. |
| 40 | All as per BOQ Serial item No 33 above but of size 120 sq. mm 3.5 core complete all as specified and directed. |
| 41 | All as per BOQ Serial item No 33 above but of size 185 sq. mm 3.5 core complete all as specified and directed. |
| 42 | All as per BOQ Serial item No 33 above but of size 240 sq. mm 3.5 core complete all as specified and directed. |
| 43 | All as per BOQ Serial item No 33 above but of size 300 sq. mm 3.5 core complete all as specified and directed. |
| 44 | S&F Heat Shrink type straight through cable jointing kit for 1.1 KV grade Under Ground XLPE insulated Aluminium Cable complete with Jointing material and other connected accessories suitable for 3.5 / 4 core 10 to 16 sqmm complete all as specified and directed. |
| 45 | All as per BOQ Serial item No 44 above but of size 25 sqmm to 50 sqmm complete all as specified and directed. |
| 46 | All as per BOQ Serial item No 44 above but of size 70 sqmm to 120 sqmm 3.5 core complete all as specified and directed. |
| 47 | All as per BOQ Serial item no 44 above but of size 150 sqmm to 240 sqmm 3.5 core complete all as specified and directed. |
| 48 | S&F in repairs LED street light with IP 66 protection and front toughen glass luminaries of capacity 45/50 watt with high power LED and ensure uniform light distribution complete all as specified and directed. |
| 49 | S&F in repairs LED security light with IP 66 protection and front toughen glass luminaries of capacity 70-75 watt with high power LED and ensure uniform light distribution complete all as specified and directed. |
| 50 | S&F in repairs LED street light with IP 66 protection and front toughen glass luminaries of capacity 120-150 watt with high power LED and ensure uniform light distribution complete all as specified and directed. |
| 51 | S&F in repairs LED flood light of IP protection 66 with front toughen glass luminaries of capacity 120-150 watt with high power LED and ensure uniform light distribution complete all as specified and directed. |
| 52 | S&F in repairs LED flood light of IP protection 66 with front toughen glass luminaries of capacity 100 watt with high power LED and ensure uniform light distribution complete all as specified and directed. |
| 53 | S&F in repairs 20 watt LED post top lantrern fitting made in cast aluminium spigot, housing with decorative clear acrylic diffuser and IP 65 protection with and including LED lamp and all necessory electric connection with from junction box to post top lantern complete all as specified and as directed. |
| 54 | S&F in repairs 40 watt LED post top lantrern fitting made in cast aluminium spigot, housing with decorative clear acrylic diffuser and IP 65 protection with and including LED lamp and all necessory electric connection with from junction box to post top lantern complete all as specified and as directed. |
| 55 | S&F in repairs 10 watt LED bollard light 6000K, 2 feet long, 230V complete complete all as specified and as directed. |
| 56 | S&F MS Fabrication work consisting of wire mesh, MS Angle square pipe, flat iron etc duly cut into shape and size to fabricate cage for Post top lanterns mounted on boundary wall with & including grouting on wall, one coat of red oxide primer and two coats of synthetic enamel paint complete all as specified and directed. |
| 57 | S&F Mild steel angle in framing of valve pit cover including hinge and locking arrangement complete all as specified and directed. |
| 58 | S&F 3mm thick mild steel plate in covering of valve pit chamber complete all as specified and directed. |
| 59 | S&F in repairs thermoplastic street light junction box, weather proof having ingress protection level IP-66 and size L(254-255mm) x B(180-205mm) x H(111-112mm) duly fixed with Aluminium flat clamp and support made of 25mmx3mm/Flush in existing wall, duly painted with aluminium paint over a coat of red oxide metal prmer complete (including 1 no. 5 way cable connector suitable to connect 16 Sqmm Aluminium cable 3 nos polymide cable gland having sealing range 17-25 mm with 1 No 19 mm PVC blend) complete all as specified and directed. |
| 60 | M&L for painting external surfaces of steel tubular poles and bracket of height upto 9m above ground level after preparation of old painted and rusted surfaces with two coats of aluminium paint over a coat of red oxide primer and writing pole No. with black colour on round yellow background or pasting of sticker 100 mm dia (yellow colour) with black lettering 50mm complete all as specified and as directed. |
| 61 | S&F end termination (cable gland & lugs ) for cable of size 10 to 25 Sqmm 4 Core complete all as specified and directed. |
| 62 | S&F end termination (cable gland & lugs ) for cable of size 35 to 70.Sqmm 3.5 Core complete all as specified and directed. |
| 63 | S&F end termination (cable gland & lugs ) for cable of size 95 to 150 Sqmm 3.5 Core complete all as specified and directed. |
| 64 | S&F end termination (cable gland & lugs ) for cable of size 185 to 400 Sqmm 3.5 Core complete all as specified and directed. |
| 65 | M&L for making of 20mm hole in steel tublar pole, by using drill/electric arc welding etc at a level 0.9 mtr above ground level and 100mm below the bottom connecting cable complete all as specified and directed. |
| 66 | S&F in repairs GI bracket on street light pole/ boundary wall for post top lantern made of 40 mm dia light grade GI pipe including fixing clamps, nuts and bolts,/cement work and painting with two coats of aluminium paint over a coat of red oxide metal primer complete for maximum length of 1.20mtr complete all as specified and directed. |
| 67 | S&F in repairs low density poly ethylene (LDPE) pipe, bore of pipe 40mm, flexible type of pressure rating 6.0 kg/sqm laid through the coping of the poles for passing of pipes complete all as specified and directed. |
| 68 | S&F in repairs low density poly ethylene (LDPE) pipe, bore of pipe 32mm, flexible type of pressure rating 6.0 kg/sqm laid through the coping of the poles for passing of pipes complete all as specified and directed. |
| 69 | S&F PVC pipe of size 150mm dia cut in to size, grilled and duly embeded in concrete in the post hole inside the ground for making a post for fixing of post of lantern complete all as specified and directed. |
| 70 | S&F PVC pipe of size 50mm dia cut in to size, grilled and duly embeded in concrete in the post hole inside the ground for making a post for fixing of post of lantern complete all as specified and directed. |
| 71 | S&F in repairs perforated GI Cable Tray, made of Plain GI sheet of thickness 1.20 mm, of size 600 mm wide x 75 mm depth with cover duly fixed on wall / Roof by M.S. Bracket or hanging from ceiling with down rod etc, complete all as specified and directed. |
| 72 | All as per BOQ Serial item No 71 above but of size 450mm complete all as specified and directed. |
| 73 | All as per BOQ Serial item No 71 above but of size 300 mm complete all as specified and directed. |
| 74 | All as per BOQ Serial item No 71 above but of size 200 mm complete all as specified and directed. |
| 75 | All as per BOQ Serial item No 71 above but of size 100 mm complete all as specified and directed. |
| 76 | S&F in repairs outdoor type floor mounted, 4 way Bus Bar Chamber made 3.0 mm thick M.S. sheet duly painted with powder coated paint (RAL7032 Siemens Grey) having 4 Nos of insulated Aluminium Bus Bar of 200 A rating and size 800mm(w) x 800mm(H) x 400mm(D) complete with hinged Single Door in both front and rear side (with locking arrangement), 4 side sloped roof and 600mm long M.S Angle (50x50x6mm) leg, Earthing Termination Bolt etc. complete all as specified and as directed. |
| 77 | S&F in repairs outdoor type floor mounted 4 way Bus Bar Chamber made 3.0 mm thick M.S. sheet duly painted with powder coated paint (RAL7032 Siemens Grey) having 4 Nos of insulated Aluminium Bus Bar of 63 A rating and size 800mm(w) x 800mm(H) x 400mm(D) complete with hinged Single Door in both front and rear side (with locking arrangement), 4 side sloped roof and 600mm long M.S Angle (50x50x6mm) leg, Earthing Termination Bolt etc. complete all as specified and as directed. |
| 78 | Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed. |
| 79 | S&F DMC/SMC/Ebonite cable connector 4 Way complete all as specified and directed. |
| 80 | S&F in repairs LED strip 120 Led 10.5w/m-5mm-12v-IP65 Waterproof warm white complete all as specified and directed. |
| 81 | S&F in repairs PVC insulated 25 Sqmm S/C copper cable complete all as specified and directed. |
| 82 | S&F in repairs PVC insulated 16 Sqmm S/C copper cable complete all as specified and directed. |
| 83 | S&F in repairs PVC insulated 50 Sqmm S/C copper cable complete all as specified and directed. |
| 84 | S&F in repairs copper lugs 25mm ring type complete all as specified and directed. |
| 85 | S&F in repairs copper lugs 16mm ring type complete all as specified and directed. |
| 86 | S&F in repairs copper lugs 50mm ring type complete all as specified and directed. |
| 87 | Reparing and painting of feeder pillar / LT panel board complete all as specified and directed as under :- |
| 88 | S&F in repairs MS sheet for feeder pillar for Roof or for Panel Board Door by cutting into required size and shape, moulding, Welding, drilling etc. as replacement of old worn out sheets including painting with 2 coats of existing shades of Synthetic Enamel Paint over a coat of Red Oxide Metal Primer complete all as specified and directed. Note : Thickness of the new sheet shall have to be same as per existing one. |
| 89 | S&F in repairs Capsule type MS door hinges for Feeder Pillar / Panel Board duly fixed by welding complete all as specified and directed. |
| 90 | S&F in repairs Castle type door locks for Feeder Pillars / Panel Boards as per existing one 4 complete all as specified and directed. |
| 91 | S&F in repairs aluminium Lugs/ thimbles of sizes as required on ground by crimping and wrapped with insulation tape complete all as specified and as directed. |
| 92 | S&F in repairs DMC / SMC / Ebonite Cable Connector 3 or 4 way suitable for 1100 volt grade all as per existing type / Current Rating etc. complete all as specified and as directed. |
| 93 | S&F in repairs Aluminium bus bar of any size with necessary drilling and providing suitable size & colour heat shrinkable type PVC tape complete all as specified and directed. |
| 94 | Preparation of old painted surface in situ of feeder pillars (for external surfaces only) and removing of all loose darts and greasy spots and filling of cavities by providing puttyand M&L for applying one coat of red oxide primer over & including two coats of synthetic enamel paint and complete all as specified and directed. Note : Painting to be done either by using Spray Painting Machine or by using Roller. Brush shall not be used. Please Enable Macros to View BoQ information |
| 95 | Preparation of old painted surface in situ of feeder pillars (for external surfaces only) and removing of all loose darts and greasy spots and filling of cavities by providing puttyand M&L for applying one coat of red oxide primer over & including two coats of synthetic enamel paint and complete all as specified and directed. Note : Painting to be done either by using Spray Painting Machine or by using Roller. Brush shall not be used. Please Enable Macros to View BoQ information |