| 1 | Demolition of brick work built in cement mortar of any description including all quions arches, pillars etc complete all as specified and directed. |
| 2 | Dismantling of wrought or mild steel work of any description and in any position complete all as specified and directed. |
| 3 | Excavating in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth for shafts, cesspits, manholes, pier holes etc and getting out in soft/loose soil complete all as specified and directed. |
| 4 | M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete including sub base of floors complete all as specified and directed. |
| 5 | Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed. |
| 6 | Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 7 | M&L for brickwork with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed. |
| 8 | Description all as per item No 7 here-in-above but except brick (used brick obtained from demolition) complete all as specified and directed. |
| 9 | Use & waste of Formwork to concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter and sides of pillars, posts, struts, piers, columns and stanchions etc complete all as specified and directed |
| 10 | S&F Mild Steel round bars 10mm dia and over, cut to length, bent to shape required, including ranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips Fe-410-W (Gde. E-250)Part- I quality-A orFe 290 (Gde -E-165) complete all as specified and directed. |
| 11 | S&F for Mild Steel bars but 6mm to 8mm dia., cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed |
| 12 | M&L reinforcement cement concrete M-25 (nominal mix) using 20 mm graded stone aggregate in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, Columns, pillars, piers, posts and struts concrete complete all as specified and directed |
| 13 | M&L for rendering 15mm thick cement plaster on fair face of brick work or concrete surface, masonry surfaces other in cement mortar 1:4 finished complete all as specified and directed. |
| 14 | M&L for rendering 15mm thick cement plaster on surface other than fair face of brick-work or concrete surface, masonry surfaces other in cement mortar 1:4 finished complete all as specified and directed. |
| 15 | M&L for Preparing new plastered or unplastered surfaces of walls and applying two coats of cement base paint white or tinted over &including chalk whiting complete all as specified and directed. |
| 16 | S&F for Framed work of rolled mild steel conforming to Gde Fe 410-0 as in doors or gates of angle or other section with gusset plates, rails, braces, etc, drilled for fixing of steel sheeting or other covering; doors etc to be prepared for hanging or sliding with and including either hooks & hinges or steel hanging door fittings (exclusive of steel sheeting, running rails & guides) and hanging, fastening & fixing complete all as specified and directed. |
| 17 | M&L for 18 - 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white ement (1:2) using marble dust with admixture of pigment to match with shade of granite including moulding complete all as specified and directed. |
| 18 | Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground complete all as specified and directed. |
| 19 | Dismantling of chain link fencing complete all as specified and directed. |
| 20 | Excavating in post holes (or similar holes) in any type of soil each not exceeding 0.5cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm ,watering and removing surplus soil to a distance not exceeding 50m and making good surface complete all as specified and directed. |
| 21 | M&L for plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate as in post holes, filling and mass concrete complete all as specified and directed. |
| 22 | M&L for Preparing new or previously untreated steel & iron surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over & including a coat of red oxide primer complete all as specified and directed. |
| 23 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire complete all as specified and directed. |
| 24 | Supply only chain link mild steel galvanized fencing, any type or size complete all as specified and directed. |
| 25 | Schedule of Credit (MINUS) Rs. 2,00,500.00 B/F from Serial Page No. [Note : Details of items for schedule of credit is given on Srl Page No. _____] This amount shall be automatically deducted to arrive at tendered sum Please Enable Macros to View BoQ information |