| 1 | Excavation in trenches not exceeding 1.5m in wide and not exceeding 1.5 m in depth for laying of pipe, cable, poles etc, and getting out in soft soil, complete all as specified and as directed by Engineerr-in-Charge. |
| 2 | Excavation in trenches not exceeding 1.5m in wide and exceeding 1.5 m in depth but not exceeding 3.0 m in depth for laying of pipe, cable, poles etc, and getting out in soft soil, complete all as specified and as directed by Engineerr-in-Charge. |
| 3 | M&L for Sand cushioning to underground cables 8 cm below the cable before laying & 15 cm above the cable after laying, complete all as specifiedand as directed by the Enge-in-Charge. Note : Punned thickness of 18 CM will be measured and paid for. |
| 4 | Supply and laying of factory made, machine pressed, unreinforced, pre-cast concrete cable cover class LV type-1 flate size 250mm x 150mm x 40mm, complete all as specified and directed |
| 5 | M & L for returning, filling in including spreading leveling watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed. |
| 6 | M & L for removing surplus soil to a distance not exc. 50 M and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed. |
| 7 | M&L PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation, filling mass concrete including necessary form work. |
| 8 | M&L for PCC 1:3:6 type C 1 using 20 mm graded aggregate block masonry with solid block ,exc 10 cm in width and setting in mortar complete for coping of pole including necessary from work and fair finish to the exposed surface area without using extra cement complete all as specified and directed. |
| 9 | Material and labour for cement concrete in foundation, filling and mass concrete type B2 1:2:4 with using 40mm aggregate |
| 10 | Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade complete all as specified and directed. |
| 11 | Supply and fixing in repair Steel tubular swaged street light poles complete with pole arms 1.2 m & cast iron base plate ,finial taper plug,bolts,nuts and screws as specified type 410 SP-31 9.0 mtr long and painting with two coat of aluminium paint over one coat of primer on exposed surface of pole all as specified and directed by Engr-in-Charge.( NOTE- Excavation & PCC will be measured and paid separately) |
| 12 | Supply and laying in replacement and testing of XLPE insulated, armoured, haeavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 120 Sqmm 3.5 core laid in trences or passing through pipes.ducts or fixed to walls/poles completer all as specified.Note :- Excavation and earth work shall be measured and paid separately under respective items. |
| 13 | Supply and laying in replacement and testing of XLPE insulated, armoured, haeavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 95 Sqmm 3.5 core laid in trences or passing through pipes.ducts or fixed to walls/poles completer all as specified.Note :- Excavation and earth work shall be measured and paid separately under respective items. |
| 14 | Supply and laying in replacement and testing of XLPE insulated, armoured, haeavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 50 Sqmm 3.5 core laid in trences or passing through pipes.ducts or fixed to walls/poles completer all as specified.Note :- Excavation and earth work shall be measured and paid separately under respective items. |
| 15 | Supply and laying in replacement and testing of XLPE insulated, armoured, haeavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 25 Sqmm 2.0 core laid in trences or passing through pipes.ducts or fixed to walls/poles completer all as specified.Note :- Excavation and earth work shall be measured and paid separately under respective items. |
| 16 | Supply and laying in replacement and testing of XLPE insulated, armoured, haeavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 10 Sqmm 2.0 core laid in trences or passing through pipes.ducts or fixed to walls/poles completer all as specified.Note :- Excavation and earth work shall be measured and paid separately under respective items. |
| 17 | Supply and fix off load change over switch 415 Volts in sheet metal enclosure 4 pole of capacity 400 Amps complete all as specified and directed. |
| 18 | Supply and fixing of cross arms braciing support clamps, back plates fabricated from steel section made out of Fe-0-310/Fe-0-410 including nuts, bolts and washers welding, drilling hole complete with two coats of aluminium paint over one coat of primer complete all as specifed and directed. |
| 19 | M&L for fixing in replacement of ACSR conductor any size drawn straight horizontal on over head lines on existing poles including binding with insulators. Weight of conductor shall be measured straight horizontal distance between centre of two adjacent poles and calculating weight of conductor of size and length by adding 3% extra for sag ,jointing jumpers,etccomplete all as specified and directed by Engr-in-Charge. |
| 20 | M&L for fixing in replacement of galvanized steel wire 4mm dia for continuous earth wirecomplete all as specified and directed by Engr-in-Charge. |
| 21 | S&F PVC Spacer 2/4 way for LT over head line 1100 V complete all as specified and directed by Engr-in-Chage. |
| 22 | M&L for fixing in replacement of stay assembly complete with stay plate bow, stay rod of dia 16mm and gavanised iron stay wire stranded of size 7/4mm and accessories as shown in electric plate No 1 of SSR part-I (loop type insulator, stay clamps, excavation and concrete shall be measured separately) complete all as spd and directed by Engr-in-Charge. |
| 23 | M & L spray for painting and numbering of electric poles including street light brackets, cross arms, GOD system, four pole structure,two pole structure, LT panels from out side with two coats of aluminium duco paint after cleaning and preparing the surface of poles of any size complete all as specified and as directed by Eng-in-chaarge. |
| 24 | Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. |
| 25 | Taking down old unserviceable feeder pillar box and supply and fix in replacement feeder pillar box of suitable size with incommer MCCB of cpacity 160 Amps, 415V , with 4 Nos aluminium bus bar complete size all as specified and directed. |
| 26 | Supply & fix in repair including install testing and commissioning of LT panel board (outdoor type) cubical shape, 3 phase, 4 wire, copper bus bar rating 400 Amps for phases and 200 Amps for neutral made out of CRCA sheet , 3.15 mm thick ,factory fabricated , CPRI approved , powder coated ,dust and vermin proof , provn for ventilation , angle iron frame and four legs of 50x50x6mm thick angle iron ,4 ft long grouted on PCC foundation of height not less than 30 cm from the ground level , grouting properly ,and of suitable size to accomodate the items mentioned below and having seperate compartment /chambers for cable gallery busbar,switch gear etc including space to accommodate the followig all as specified and comprising of following including necessary cable connections to the MCCBs ,Voltmeter,Ammeter and cable lugs etc . (i) 4 Pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity 35 KA -01 No (Incomer)(ii) 3 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 35 KA -01 Nos (outgoing)(iii) MCB TPN 63 amps- 02 Nos(iv) Isolator 100 Aps TPN-01 Nos(v) MCB SPN 63 Amps -06 No. (vi) Voltmeter,digital type 0- 400 Volt,with selector switch -01 set (vii) Ammeter Digital type 0-100Amps, with selector switch and CT'-1set (viii) Phase indicating lamps LED type ( red , yellow, blue) -03 sets |
| 27 | Supply & fix, install testing and commissioning of LT panel board (indoor type) cubical shape, 3 phase, 4 wire, copper bus bar rating 400 Amps for phases and 200 Amps for neutral made out of CRCA sheet , 3.15 mm thick ,factory fabricated , CPRI approved , powder coated ,dust and vermin proof , provn for ventilation , angle iron frame and four legs of 50x50x6mm thick angle iron ,4 ft long grouted on PCC foundation of height not less than 30 cm from the ground level , grouting properly ,and of suitable size to accomodate the items mentioned below all as specified and comprising of following including necessary cable connections to the MCCBs ,Voltmeter,Ammeter and cable lugs etc . (i) 4 Pole MCCB 320 Amp, 50 Hz, 415 V with rupturing capacity 35 KA -01 No (Incomer)(ii) 3 Pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity 35 KA -04 Nos (outgoing). (iii) MCB SPN 63 Amps -01 No. (iv) Voltmeter,digital type 0- 400 Volt,with selector switch -01 set (v) Ammeter Digital type 0-100Amps, with selector switch and CT'-1set (vi) Phase indicating lamps LED type ( red , yellow, blue) -01 sets |
| 28 | Deduct Schedule of Credit of Rs (-) 121179.50 (Minus) as listed in Schedule 'A' (Contd). Contract Sum shall be arrived after deducting the credit amount.Note :- Tenderers will not quote against this item being a firm amount. Please Enable Macros to View BoQ information |