| 1 | Taking down cement plaster on stone/brick/concrete surfaces including racking out joint, hacking for key, scrubbing down with water complete all as specified and as directed. |
| 2 | Demolition of cement concrete(unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 3 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed. |
| 4 | Dismantling of wrought or mild steel work of any description not otherwise described into primary parts complete all as specified and directed. |
| 5 | M & L for brick work with fly ash bricks of class designation 7.5 and non-modular size as per IS 12894: 2002, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed. |
| 6 | M & L for brick work with sub class 'B' bricks, non-modular sizes as per IS 1077: 1992, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed. |
| 7 | M & L for cement concrete M10 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and as directed. |
| 8 | M & L for cement concrete in surface channels and drains in M10(Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. |
| 9 | M & L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc. complete all as specified and as directed. |
| 10 | M & L for walling (curved on plan to a mean radius exceeding 6 metre) of random rubble, uncoursed, well bonded, bedded and solidly hearted built in cement mortar (1:6) complete all as specified and as directed. |
| 11 | M & L except stone for walling (curved on plan to a mean radius exceeding 6 metre) of random rubble, uncoursed, well bonded, bedded and solidly hearted built in cement mortar (1:6) complete all as specified and as directed. |
| 12 | Extra over stone walling of lime or sand stone for hammer dressing to face stones and dressing of face beds and joints with maximum depression of face from straight edge held against the dressed surface not exceeding 20 mm, of random rubble walling, uncoursed or brought upto course complete all as specified and as directed. |
| 13 | Material and labour for plastering 15 mm thick on stone masonry surfaces or other than fair faces of brick work or on one side of lathing (on vertical surfaces) in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed. |
| 14 | Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 with integral water proofing compound finished even and fair complete all as specified and as directed. Note: - Water proofing compound shall be measured and paid for separately. |
| 15 | Supply only liquid water proofing compound complete all as specified and directed. |
| 16 | M&L for preparing newly plastered walls surfaces and applying two coats of cement base paint over and including a coat of suitable primer complete all as specified as mentioned in note of the item and directed by Engineer-in-Charge.Note :- Steps to be followed for cement base paint :-Colour scheme of cement base paint passed by GE.(a) Curing the newly plastered surface of wall by spray gun. (b) Applying one coat of primer.(c) applying one coat of cement base paint(d) curing of surface by spray gun(e) Applying second coat of cement base paint after that curing of surface by spray gun. |
| 17 | M & L for cement concrete M7.5 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 100 mm thick in sub base for laying tiles, pavings, floorings etc. complete all as specified and as directed. |
| 18 | Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M35 grade conforming to IS 15658: 2021 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in rubber mould, glossy finish of approved colour, laid in required colour and pattern over and including 25 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. complete all as specified and as directed. |
| 19 | Fixing only 60 mm thick factory made cement concrete interlocking paver block of M 35 grade conforming to IS 15658: 2021 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in rubber mould, glossy finish of approved colour, laid in required colour and pattern over and including 25 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. complete all as specified and as directed. |
| 20 | M & L for chequered cement concrete tiles, cast in rubber mould, glossy finish of approved colour, general purpose, double layer, size 20 cm X 20 cm X 25 mm thick, with mixture of white and grey cement in equal proportions and pigments, set, jointed and pointed in neat cement slurry in floor including laying over 20 mm thick bedding of cement mortar(1:4) complete all as specified and as directed. |
| 21 | M & L for laying full body vitrified matt finish paving tiles of size 300x300x10mm thick suitable for exterior areas, set and jointed in neat cement slurry and pointed in white cement mixed withpigment to match the colour of tiles, confirming as per IS 15622:2017, laid over and including 15 mm thick screed in CM 1:6, complete all as specified and directed. |
| 22 | Providing and laying at or near ground level factory made kerb stone of any size, top bullnosed shape, made of M-25 (Design Mix) grade cement concrete, in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed. |
| 23 | M & L for 75 mm thick plain cement concrete M10(Nominal Mix) using 40 mm nominal size graded stone aggregates, laid in alternate panel, finished surface even and fair including filling in position with 85/25 industrial grade bitumen mix filler of proportion 80 kg of hot bitumen, 1 kg of cement and 0.25 cubic metre of coarse sand as in plinth protection complete all as specified and as directed. |
| 24 | S & F hot rolled medium and high tensile structural steel of grade E 250 quality C conforming to IS 2062: 2011 as in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed. |
| 25 | Dismantling fencing wire mesh, any type complete all as specified and as directed |
| 26 | M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed. |
| 27 | M & L for cement concrete in foundation, filling and mass concrete in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed. |
| 28 | S & F hot rolled low tensile structural steel of grade E165 as per IS 15911: 2010 as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar works complete all as specified and as directed. |
| 29 | M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed. |
| 30 | Fixing only galvanized steel chain link fencing including line wires any mesh, size and type to any type of standards, rails, straining bolts, etc. including provn of binding wire complete all as specified and as directed. |
| 31 | Supply only galvanized steel chain link fence fabric of any mesh size, made out of any nominal dia mesh wire, heavy zinc coating type conforming to IS 2721: 2003 complete all as specified and as directed. |
| 32 | S & F in repairs galvanized steel barbed wire with two strands of line wire of dia 2.24 mm and barbed with point wire of dia 2 mm at 75 mm spacing straining and fixing to any type of standards, rails, straining bolts including securing or tying at crossings with and provision of galvanised iron binding wire, GI staples or steel pins, etc. complete all as specified and as directed. (two strand of line wire will be measured as one unit). |
| 33 | S & F mild steel screw bolts (machine made), diameter of neck 5 to 10 mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exceeding 5 cm long complete all as specified and as directed. |
| 34 | Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 35 | Preparation of newly or previously untreated brick, stone, concrete, asbestos cement or plaster surface of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of primer of the same manufacturer complete all as specified and as directed. |
| 36 | Preparation of newly or previously untreated steel surface of any description not exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 37 | Taking up or down 15 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified and as directed. |
| 38 | Taking up or down 20 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified and as directed. |
| 39 | Supplying & fixing to walls and ceilings or laid in floors 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 40 | Refixing 15 mm bore of steel tubing and connections in new or old positions (walls, ceilings, floors, etc.) complete all as specified and as directed. |
| 41 | Supplying & fixing to walls and ceilings or laid in floors 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 42 | Refixing 20 mm bore of steel tubing and connections in new or old positions (walls, ceilings, floors, etc.) complete all as specified and as directed. |
| 43 | Dismantling water tanks capacity exceeding 250 litres but not exceeding 500 Litres and removing to store complete all as specified and as directed. |
| 44 | S & F rotational moulded polyethylene tripple layer water tanks, white colour (vertical cylindrical with close top) as per IS 12701: 1996 of 500 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes complete all as specified and as directed. |
| 45 | Dismantling water tanks capacity exceeding 500 litres but not exceeding 1000 Litres and removing to store complete all as specified and as directed. |
| 46 | S & F rotational moulded polyethylene tripple layer water tanks, white colour (vertical cylindrical with close top) as per IS 12701: 1996 of 1000 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes complete all as specified and as directed. |
| 47 | S & F in repairs 20 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete all as specified and as directed. |
| 48 | S & F in repairs ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20 mm size, minimum weight 210 grams complete all as specified and as directed. |
| 49 | Disconnecting existing water tanks capacity exceeding 250 litres but not exceeding 500 Litres, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required, reconnecting and re-fixing in position (cleaning repairing, etc. measured separately) etc complete all as specified and directed. |
| 50 | S & F in renewal water tank cover / lid in round shape of any size of approved make and colour as approved by GE complete all as specified and directed. |
| 51 | S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and as directed. |
| 52 | S & F in repairs hexagonal wire netting, size of aperture 25 mm, dia of galvanised steel wire 1.40 mm as per IS 3150: 1982 fixed with tinned tacks of wire staples complete all as specified and as directed. |
| 53 | Preparation of newly plastered surfaces on walls and applying three coats of white wash complete all as specified and as directed. |
| 54 | S & F ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20 mm size, minimum weight 210 grams complete all as specified and as directed. Please Enable Macros to View BoQ information |