| 1 | Taking down old unsv LT pole (concrete poles/steel pole) and Supplying, transporting to site, erecting, and fixing in position, steel tubular swaged and welded poles of Overall height 9 metres, type 410 SP-31, IS-2713 marked, with cast iron base plate (fillet welded to poles), pole cap / finial taper plug, bolts, nuts, washers etc, including painting on the outside with two coats of aluminium paint over a coat of red oxide primer on exposed surfaces and black bituminous paint on steel surface embeded in concrete and painting 05 nos band /strips with fluorescent , Black/ Red/ White/ Green and Black synthetic enamel paint ( 30 cm wide each) at a distance of 30 cm from plinth block and numbering of poles, complete all as specified and directed by Engr-in-Charge.(Note:- (i) Poles shall be swaged and welded at manufacturer’s factory and not at site. The inner surface shall be factory painted) (ii) Excavation , earth work & PCC to be considered separately taken in the sch items. |
| 2 | Taking out UNSV street light any type and size and supply and fixing LED street light fitting 70 watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, including thermal mamangement in multiple optics and equipped with IP65 protection complete all as specified and directed. |
| 3 | S&F pole mounting type junction box factory made of size 300x200x100 mm of FRP sheet duly powder coated with front openable hinged door, locking arrangements with 04 nos. Al bus bar 40 Amps rating mounted on porcelain insulator, cable glands and lugs consisting DIN type rails for fixing MCB SPN 6/10 Amps 10 KA suitable for domestic loading-01nos. including mild steel flat iron clamp made out of 40x4mm FI, nuts, bolts and washers duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 4 | S&F one run of 3 core 2.5 sqmm (nominal area) PVC insulated and PVC sheathed multi stranded copper conductor cable LT 1100V grade conforming to IS: 70987 for connecting to street light and pole JBs complete all as specified and directed. |
| 5 | Supply, laying cable XLPE Insulated, armoured heavy duty electric cable 1100V grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed. |
| 6 | Taking down of old UNSV bracket S&F of mounting bracket made of 40mm bore (or higher to suit the opening of fitting) light grade GI pipe of approx 1.5 mtr length bent to shape and fixed to pole (30cm bend approx 120 degree angle ) with FI 40mmx6mm clamps-02nos. And suitable size nuts,bolts, including and painting with two coats of aluminium paint over one coat of red oxide primer complete all as specified and directed. |
| 7 | S&F cable throwing pipe of 40mm bore (or higher to suit the opening of fitting) made of light grade GI pipe of approx 1.5 mtr length and fixed to pole with FI 40mmx6mm clamps-01nos. And suitable size nuts,bolts, including painting with two coats of aluminium paint over one coat of red oxide primer complete all as specified and directed. |
| 8 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in Soft/Loose soil including trimming sides and bottom of trenches complete all as specified and directed. |
| 9 | Excavation in trenches not exceeding 1.5 m wide and for each additional 1.5 m or part thereof in depth beyond the first 1.5 m and getting out in Soft/Loose soil including trimming sides and bottom of trenches complete all as specified and directed. |
| 10 | Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables complete all as specified and directed. |
| 11 | M & L for Bricks for protection cover to under ground cable (with standard size fly ash bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10mm complete all as specified and directed. |
| 12 | Returning, filling-in, including spreading, watering and well ramming in layers not exceeding 25 cm thick each, in soft /loose soil complete all as specified and directed. |
| 13 | Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 14 | Dismantling of unsv ACSR conductors complete all as specified and directed. |
| 15 | Dismantling of unsv insulator any type and size complete all as specified and directed. |
| 16 | Dismantling of stay assembly with accessories complete all as specified and directed. |
| 17 | M&L for cement concrete type C2 1:3:6 using 40mm graded stone aggregate in foundations, filling and mass concrete (around the poles in pit) complete all as specified and directed.. |
| 18 | M&L for cement concrete type B1 1:2:4 using 20mm graded stone aggregate for coping of poles including necessary framework and fair finishing of exposed surfaces complete all as specified and directed. |
| 19 | M&L for cement concrete type D2 1:4:8 using 40mm graded stone aggregate in foundations (below pole) complete all as specified and directed. |
| 20 | Dismantling old existing MS cross arms of any type/shape complete all as specified and directed. |
| 21 | Supply & fixing single pointed air termination aluminium rod, 12 mm dia, 300 mm long complete all as specified and directed. |
| 22 | Supply & fixing aluminium strip 25mm x 3.15mm complete with saddles and fixing screws for fitting the strip etc for roof and down conductors complete all as specified and directed. |
| 23 | S&F Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 03 Nos. 8mm dia 25mm long hex. Head screw complete all as specified and directed. |
| 24 | M&L for earthing complete with GI earth plate electrode 60cmx60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to and including earth lead of copper strip 32x6mm by means of bolts, nuts, check nuts and washers of copper/bronze all as shown in electrical plate No 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion and excavation and charcoal, common salt and chemical surrounded with 15cm all around the plate and earth work in any type of strata, PCC 1:3:6 type C1 in chamber, precast RCC cover 50mm thick in cement concrete 1:2:4 type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4 Kg/Sqm) with cast iron frame, funnel with wire mesh, 20mm bore GI pipe medium grade watering pipe, lugs, 40mm bore GI pipe medium grade protection pipe complete all as specified and directed. |
| 25 | M&L for tube medium grade galvanised, with fiting and fixed complete to walls, floors and ceiling of size 40mm dia for fixing of air termination complete all as specified and directed. |
| 26 | M&L for galvanised iron strip 32X6 mm burried in ground complete all as specified and directed. |
| 27 | M&L for PCC 1:3:6 type C1 (20 mm graded aggregate) complete all as specified and directed. Please Enable Macros to View BoQ information |