| 1 | M&L for Cleaning and maintenance of solid/liquid mud/any type of solid content including mud, brick bats, empty containers of any type, rags, polythene or any similar tems deposited in underground sewage lines at any depth upto 2.5 metres including manholes/inspection chambers of any size and any depth, using SUPER SUCTION MACHINE TRUCK MOUNTED HAVING SUCTION CAPACITY 1000 TO 4000 CUM/HRS, JETTING PUMP WITH WORKING PRESSURE AT LEAST 120 BAR having facilities of high pressure water thermoplastic fiber braided water jetting hose and through conicalround shape nozzler pipe. Bottom surface of manholes/inspection chambers & sewage lines should be visible after cleaning process. Sludge/sludge water/any type of waste recovered from sewage ines/manholes/nspection chambers shall be disposed by digging a well complete all as specified and as directedNote: 1.Lines once cleared will be maintained through out the period of the contract for free flow. If there is any blockage during the period of the contract,same will be cleaned without any extra cost by the contractor.2. Rate inclusive of Honey sucker Machine, T&P complete3. Rate of Digging well includes excavation of soil incl returning filling, levelling of surplus soil & suitably sprinkled on top using bleaching powder qty as requied & as directed by EIC. |
| 2 | M& L for Cleaning of cook house /storm drain or Drain of any description by Mechanised equipments/Manually , to clear the sludge/blockage inside the Drain and Hume pipe and will be flushing with water to drain out bloackage etc. including removing Drain cover and re- fixing the same after cleaning complete all as specified and as directed. |
| 3 | M&L for Cleaning of bore underground sewerline from any type of trap (WCs/Gully trap/floor traps/C pipes/Nahani traps/Bathrooms etc) to 1st manhole (including trap & manholes by taking off manhole covers and re-fixing the same after cleaning) of any description, underground and at any depth by removing any type of blockage including de-sitizig and de-chocking (Sludge water shall be duposed off at authorized dumping site declared by local administration outside MD land complete all as specified and as directed.Note:- (a) The complaints shall be attended on the same day and complaints slips duty signed by the user will be deposted back to the JE(Civil) on the same day(b) A penalty of Rs 200/- per day per person will be levied in case of absence of any of safawisia or helper(c) A pucca bound register shall be maintained for this purpose which shall always be kept is custody of JE Civil indicating date and time of complaint informed and rectified respectively(d) Five complaints will be count as Each Jeb for payment purpose. |
| 4 | M& L for Cleaning of septic tank/STP/open-sump including drainage system by blocking temporarily the inlet with approved wooden plugs and bailing/ pumping out water from septic tank/soak pit and scraping out sludge, organic matter /inorganic matter, soft /semi solid matter and removing to distance exc 50 m but n.exc 100 m from the starting point and filling into shallow pits n.exc 1.5 m deep and removal of wooden plugs and channeling the water back complete all as specified and as directed. Note :- (a) Net volume of sludge shall be measured after dewatering by depositing in a shallow pit. The depth of sludge is taken by rodding after the sludge is dewatered and dried or reducing 20% from bulk volume, complete all as specified and as directed. |
| 5 | Demolition and breaking up drain pipes 150 mm dia unserviceable (salt glazed stone ware, AC or reinforvced concrete, drain pipes) set in cement mortar at any depth under ground level complete all as specified and directed. |
| 6 | Demolition of brick work built in cement mortar including all quions, arches pillars etc. complete all as specified and directed |
| 7 | Demolition of plain cement concrete in ground floors and paving n exc. 15 cm thickness (below or above GL) complete all as specified and directed. |
| 8 | Demolition of re-inforced cement concrete of any description and in any position for manhole cover slab complete all as specified and directed. |
| 9 | Taking up or down PVC (SWR) pipes size 110/75mm dia from any position complete all as specified and directed |
| 10 | M& L for Cleaning of manhole including removal of sludge of any size and depth upto 0.75 Mtr complete all as specified and as directed. |
| 11 | M& L for Cleaning of manhole including removal of sludge of any size and depth from 0.75 Mtr to 1.50 Mtr complete all as specified and as directed. |
| 12 | M& L for Cleaning of manhole including removal of sludge of any size and depth from 1.50 Mtr to 3.00 Mtr depth complete all as specified and as directed. |
| 13 | M& L for Cleaning of manhole including removal of sludge of any size and depth from 3.00 Mtr to 4.50 Mtr depth complete all as specified and as directed. |
| 14 | M& L for excavating in trenches n exc 1.5m wide and n.exc 1.5m depth for sewage line and manholes, drain etc and getting out insoft/loose soil complete all as specified and directed. |
| 15 | M& L for excavating in trenches exc 1.5m wide and n.exc 3.00m depth for sewage line and manholes, drain etc and getting out insoft/loose soil complete all as specified and directed. |
| 16 | M& L for excavating in trenches exc 3.00m wide and n.exc 4.5m depth for sewage line and manholes, drain etc and getting out insoft/loose soil complete all as specified and directed. |
| 17 | M& L for Returning, filling in,including spreading, levelling watering and well ramming in layer not exc 25 cm in soft/loose soil complete all as specified and directed. |
| 18 | M& L for Removing excavated surplus soil at a distance n.exc 50m and depositing complete all as specified and directed. |
| 19 | M & L Plain Cement Concrete 1:3:6 Type B2 using 40 mm graded stone aggregate in foundation filling and mass concrete complete all as specified and directed. |
| 20 | M & L Pre-cast RCC 1:2:4 type B1 using 20 mm graded stone aggregate as in cover slab set in CM 1:4 complete all as specified and directed. |
| 21 | M & L TMT bars 10 mm dia and over, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clip to Fe-410 incl fabrication complete all as specified and directed. |
| 22 | M&L brick work using sub class B brick (old size) curved or straight in plan exc 6 mtr mean radius in cm (1:4) complete all as specified and directed |
| 23 | M & L Plain cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in benching/cooping including necessary form work mould and finished exposed surfaces even and smooth without using extra cement complete all as specified and directed. |
| 24 | M & L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including form moulds, mitred/stopped ends etc complete all as specified and directed |
| 25 | M & L 75 mm thick PCC (1:3:6) type C-2 using 40mm graded aggregate as in plinth protection/footpath even and smooth without using extra cement complete all as specified and directed. |
| 26 | Taking down cement plaster on brick or concrete surfaces including racking out joints hacking for key, scrubbing down with, water etc complete all as specified and directed. |
| 27 | M&L for rendering 15mm thick in CM (1:4) and finished the surface even and smooth without using extra cement complete all as specified and directed |
| 28 | Supply only integral water proofing compound, complete all as specified and as directed. |
| 29 | S&F PVC(SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in fioors,110mm bore complete all as specified and directed. |
| 30 | S&F PVC(SWR) pipes single socketed in any length with rubber ring joints fixed to fioors ,75 mm bore .complete all as specified and directed. |
| 31 | S& F PVC (SWR) bend any radius, 110 mm bore ,with access door . including all necessary work complete all as specified and directed. |
| 32 | S& F PVC (SWR) bend any radius,75 mm bore ,with access door including all necessary work complete all as specified and directed. |
| 33 | S & F 75 mm bore PVC (SWR) junction single (Single'T') , equal or unequal .fixed to wall including all necessary work complete all as specified and directed. |
| 34 | S&F 110 mm bore PVC (SWR) junction single (Single'T') , equal or unequal .fixed to wall including all necessary work complete all as specified and directed. |
| 35 | M & L DWCPE pipes 150 mm bore internal dia (ISI marked) laid in trenches, including all fittings & fixture jointed and tested complete all as specified and directed. |
| 36 | M&L for Boring of holes under road crossing , pavement,hard standing by trenchless technology using ultra sound technique and nessary machine for laying of HDPE pipes of 150mm dia suitable for 0.4mpa working pressure at a depth 1.5m & upto 3.00 m from road level, complete all as specified and as directed. |
| 37 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing coat ), removing serviceable tiles to store and rubbish off the premesises, complete all as specified and as directed. |
| 38 | S&F for colour Glazed ceramic tiles (450x300) of 7 to 8mm thick, in dado/skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thick screed bed or bedding layer in CM (1:4) complete all as specfied and directed. |
| 39 | M&L non-skid coloured ceremic tiles 8 to 10 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles laid over and including 15 mm thick screed bed or bedding layer in CM (1:6) complete all as specfied and directed. |
| 40 | S&F Vitreous China White Squatting Pan ‘ORISSA’ Pattern, size 580x440mm with ‘P’ or ‘S’ Trap, Integral Foot Rest, providing Joints between Flush Pipe and Socket of WC Pan including Flushing Cistern and Flush Pipe, fixing with and including provision of cement Concrete Bedding including Taking out/ down unserviceable WC Pan and connected Items, complete all as specified and as directed. |
| 41 | S&F in repair vitreous china premium quality wash down water closet wall hung EWC with/ivory/off white (closed pattern incl all necessary accessories like rag blts/gel gasket etc) including brackets complete all as specified and directed. |
| 42 | S&F Vitreous China White Urinal, flat back of size 465x355x265, complete including providing and fixing plugs, bedding urinal against Wall in Cement Mortar 1:2, securing urinal to plugs, grating with and including 60mm long brass screws, pointing around urinal back in cement etc complete all as specified and as directed. |
| 43 | S&F in repair vitreous china premium/1st quality wash down water closet wall hung EWC (One piece) with/ivory/off white (closed pattern incl all necessary accessories like rag blts/gel gasket etc) including 10liters capacity vitreous china valveless syphonic action type flushing cistern low level white, with inlet ball valve float and handle including brackets complete all as specified and directed. |
| 44 | S&F in repair Vitreous china Partition wall of size 310X700mm, curved shaped urinal partition with and including fixing accessories, fixing bolt, etc complete all as specified and directed. |
| 45 | S&F White PVC Flushing Cistern 10 Litre capacity, Low Level Valve Less, Syphonic Action type with Inlet, Ball Valve, Float and Handle including Cutting and pinning in Ends, making good disturbed Surfaces in Cement Mortar 1:3 and fixed including taking down/out unserviceable Flushing Cistern and connected Items, complete all as specified and as directed. |
| 46 | S&F in repair PVC water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed. |
| 47 | S & F in repairs Waste coupling of brass chromium plated for Basin/ Kitchen Sink (half or full threaded) .complete all as specified and directed. |
| 48 | S & F in repairs 32/40mm bore PVC Waste pipe for wash hand basin, complete all as specified and as directed. |
| 49 | S&F in repair stainless steel Grating doom 100mm dia complete all as specified and directed |
| 50 | S&F chromium plated Health faucet with 8mm Dia, 1.2 Meter long flexible tube and wall hook with N.R.V (Back Flow Preventer) as in repair complete all and specified and directed |
| 51 | S&F PVC connections with PTMT Nut collar bush and spanner, 600 mm long fixed to 15 mm GI pipe including necessary fixing arrangement as in repair complete all as specified and directed. |
| 52 | S&F Angular Stop Cock 15 mm dia (bore), cast copper alloy, fancy type, chromium plated, screwed down, high pressure,with wall flange screwed for Iron Pipes or Brass Ferrule and fixed, complete all as specified and directed. |
| 53 | S&F Bib Tap 15mm dia (bore), Cast Copper Alloy, Chromium Plated, screwed down high pressure with Crutch or Butterfly Handle, screwed both Ends for Iron Pipe or for Unions and fixed-in-repairs, complete all as specified and directed. |
| 54 | S&F Bib Tap long body 15mm dia (bore), Cast Copper Alloy, Chromium Plated, screwed down high pressure with Crutch or Butterfly Handle, screwed both Ends for Iron Pipe or for Unions and fixed-in-repairs, complete all as specified and directed. |
| 55 | S&F Swivel shower with shower arm 15mm size,195mm long with bend of 45 degree with flange of PTMT any colour as in repair complete all as specified and directed. |
| 56 | Taking down existing damaged IWC/EWC alongwith complete PCC and line concrete from sunken floor and providing new IWC and water proofing treatment to sunken floor as per following stage :-(i) 15mm thick plastering in CM (1:3) with WPC mixed @2% by weight at all around and base of sunken floor with proper slope.(ii) Applying a coat of 85/25 gde hot bitumen @ 0.7Kg/Sqm over a coat of bituminous primer @0.5Kg/Sqm and then pasteing of polythene film, 150 micron, matural colour with cold cut back adhessive.(iii) Fixing of 25mm dia GI pipe (med gde) spout of length 45 cm.(iv) Supply & fixing of vitreous china squatting pan, \\"ORISSA\\" pattern or padestal type, size 580x440mm white with integral footrest, P/S trap etc complete including providing PCC lean concrete (1:5:10) type E1 using 40 mm graded aggregate complete all as specified and directed.(v) 40 mm thick PCC flooring in cement concrete (1:2:4) type B-1 using 20 mm Graded aggregate complete all as specified and directed |
| 57 | NOTES:1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum. Please Enable Macros to View BoQ information |