| 1 | M&L for detection of fault by a DG Technician (Highly Skilled) as and when required basis or as directed by Engg-in-charge) for Diesel Engine Generator set of:- (a) 750 KVA DG Set No-I (Deffi Tech Accn -01 No), (b) 750 KVA DG Set No-II (Deffi Tech Accn -01 No), (c) 200 KVA DG Set (Cath Lab, CMDC, Map Ph-I, PET CT SCAN, CT SCAN -05 Nos), (d) 500 KVA (01 Nos Mother and child), (d) 320 KVA DG Set (Map Ph-II - 01 No, (e) 100 KVA DG Set (SS-2, SS-4 & Oxygen Plant -03 Nos) of make: Kirloskar / Cummins/ Greaves or any other make and alterrnator make: Kirloskar/ Cummins/ Crompton Greaves or any other make with control/ AMF panel, acoustic enclosure and connected accessories including replacement of oil /lubricant filter to keep the plant in running condition and routine maintenance as per manufacuturer's instruction and cleaning the DG set with its surroundings, maintaning battery charger complete all as specified and as directed.Note: (i) Spare parts for maintenence shall be measured and paid seperately as 'Supply Only'. (ii) The contractor shall submit visit reports at the time of payment. (iii) The above work includes detection of major/minor faults, transportation of parts of any volume if required to workshop and after repairs to the site and visiting charges of the OEM deputed techincian/high skilled technician etc. Nothing shall be paid extra by the department. |
| 2 | Supply only in replacement the following items for maintenance of DG Set 200 kVA and 100 kVA complete all as specified and as directed: - |
| 3 | Lubricant oil filter for DG set 200 KVA (Make: Kirloskar / Cummins/ Crompton Greaves or equivalent as approved by GE.) |
| 4 | Lubricant oil filter for DG set 100 KVA (Make: Kirloskar / Cummins/ Crompton Greaves or equivalent as approved by GE.) |
| 5 | Fuel filter (Pre) for DG set 100 KVA (Make: Kirloskar / Cummins/ Crompton Greaves or equivalent as approved by GE.) |
| 6 | Fuel filter (Micro) for DG set 200 KVA (Make: Kirloskar / Cummins/ Crompton Greaves or equivalent as approved by GE.) |
| 7 | Fuel filter (Primary Element) for DG set 200 KVA (Make:Kirloskar / Cummins/ Crompton Greaves or equivalent as approved by GE.) |
| 8 | Fuel filter (Secondary Element) for DG set 200 KVA (Make: Kirloskar / Cummins/ Crompton Greaves or equivalent as approved by GE.) |
| 9 | Fuel filter (Primary Element) for DG set 100 KVA (Make: Kirloskar / Cummins/ Crompton Greaves or equivalent as approved by GE.) |
| 10 | Fuel filter (Secondary Element) for DG set 100 KVA (Make: Kirloskar / Cummins/ Crompton Greaves or equivalent as approved by GE.) |
| 11 | Engine Air filter for DG set 100 KVA (Make: Kirloskar / Cummins/ Crompton Greaves or equivalent as approved by GE.) |
| 12 | Engine Air filter for DG set 200 KVA (Make: Kirloskar / Cummins/ Crompton Greaves or equivalent as approved by GE.) |
| 13 | V belt Suitable for 100/200 KVA DG set (Make: Kirloskar / Cummins/ Crompton Greaves or equivalent as approved by GE.) |
| 14 | V belt Suitable for 320 KVA DG set (Make: Kirloskar / Cummins/ Crompton Greaves or equivalent as approved by GE.) |
| 15 | V belt Suitable for 750 KVA DG set (Make: Kirloskar / Cummins/ Crompton Greaves or equivalent as approved by GE.) |
| 16 | V belt Suitable for 1000 KVA DG set (Make: Kirloskar / Cummins/ Crompton Greaves or equivalent as approved by GE.) |
| 17 | Coolant for DG Set (Make: Kirloskar, type: KOEL Care Super Genuine Coolant premix/ Servo or equivalent as approved by GE.) in 5 Ltrs non-returnable can. |
| 18 | Lubricant 15 W 40 for DG Set of make: Kirloskar, type: KOEL Care Super Genuine Oil or equivalent in Servo or other approved make |
| 19 | Battery Lead acid 12 volt, 150 AH (Make: TATA GREEN/ EXIDE/ AMCO or equivalent as approved by GE.) |
| 20 | Lub oil pressure sensor for 200 kVA DG Set, (Make: Kirloskar Code: 2H.092.11.0.00 or equivalent as approved by GE.) |
| 21 | Sensor unit for electrical temperature gauge, (Make: Kirloskar Code: 4G.085.02.0.00 or equivalent as approved by GE.) |
| 22 | Emergency 'STOP' push button, (Make: Kirloskar Code: 4H.851.02.0.00 or equivalent as approved by GE.) |
| 23 | Fuse holder including fuse with inbuilt 'fuse blown' indication, (Make: Kirloskar Code: 4H.865.08.0.00 or equivalent as approved by GE.) |
| 24 | Selector switch with 'Auto/ Manual' or 'ON/OFF' position, (Make: Kirloskar Code: 4H.865.17.0.00 or equivalent as approved by GE.) |
| 25 | Electric Relay (BAGLI - IN) for sensing and signaling to control circuits, (Make: Kirloskar Code: 6H.846.35.0.00 or equivalent as approved by GE.) |
| 26 | Channel for mounting of fuse and relays (Make: Kirloskar or equivalent as approved by GE.) |
| 27 | 18 point connector for sensing/ control circuit |
| 28 | Current transformer 300/5 Amp |
| 29 | Relay Board UL 24 volt DC, (Make: Kirloskar Code: DVO.854.09.0.00 or equivalent as approved by GE.) |
| 30 | Microprocessor based fully configured DG Set controller (Model: KG545 of make: Kirloskar Oil Engines Ltd or equivalent as approved by GE) up to 500 kVA DG Set suitable for 24 volt system with LCD display and control/ monitoring of engine speed, battery voltage, coolant temperature, lub oil pressure, oil temperature, canopy temperature, engine run hours, phase to neutral generator voltage, phase to phase generator voltage, per phase generator current, generator frequency, per phase kW, total kW, per phase kVA, per phase kVAR, earth fault current, per phase power factor, total power factor, battery charging condition, fuel level with add-on features for converting to AMF and remote monitoring in future. |
| 31 | Panel box for housing DG Set controller unit (Make: Kirloskar or equivalent as approved by GE.) |
| 32 | Engine contactor ML-2 Suitable up to 500 KVA DG Set |
| 33 | Internal wiring material for DG Set 200 kVA including single core 1.5 sqmm stranded copper flexible PVC insulated unsheathed wire, lugs, flexible tie clips, adhesive tapes, etc (Make: Kirloskar or equivalent as approved by GE.) |
| 34 | AMF relay suitable for operating DG set upto 200 kVA in auto or manual including facility of running the DG set in Test mode, AMF Controller - EC2 ( Ver 1.10) (Make:C&S/ L&T/ Schneider or equivalent as approved by GE.) |
| 35 | Automatic Voltage Regulator for 200 kVA DG Set of (Make: Kirloskar or equivalent as approved by GE.) |
| 36 | Contactor Closing Coil for 200 kVA DG Set (Make: Kirloskar or equivalent as approved by GE.) |
| 37 | Contactor ON OFF switch Elimant for 200 kVA DG Set (Make: Kirloskar or equivalent as approved by GE.) |
| 38 | Nutral contactor switch for 200 kVA DG Set (Make: Kirloskar or equivalent as approved by GE.) |
| 39 | Auto/Manual Selector switch for 200 kVA DG Set of (Make: Kirloskar or equivalent as approved by GE.) |
| 40 | MCB, SP, 6 to 32 Amp, C series |
| 41 | Supply only the following items for maintenance of DG Set 750 kVA complete all as specified and as directed: - |
| 42 | Element pre-air cleaner, (Make: Cummins code: 4020552 or equivalent as approved by GE.) |
| 43 | Element air cleaner fine, (Make: Cummins code: 4020551 or equivalent as approved by GE.) |
| 44 | Kit super BYP filter element, (Make: Cummins code: KIT3879488 or equivalent as approved by GE.) |
| 45 | Kit Fuel filter and 'O' ring, (Make: Cummins code: KIT3238493 or equivalent as approved by GE.) |
| 46 | Element lubricating oil filter, (Make: Cummins code: KIT3238204 or equivalent as approved by GE.) |
| 47 | Inhibitor corrosion, (Make: Cummins code: 3167224 or equivalent as approved by GE.) |
| 48 | Engine oil Valvoline Premium Blue 7600, 210 ltr in non returnable container (Make: Cummins code: 500255 or equivalent as approved by GE.) |
| 49 | Battery 12 volt 180 Ah model: Pulse lite, code: AX1012845 |
| 50 | Coolant for DG Set in 5 Ltrs non-returnable Can |
| 51 | Distile water for Battery |
| 52 | Copper of suitable size for rewiding of alternator |
| 53 | Supply only in replacement the following items for maintenance of DG Set 500 kVA complete all as specified and as directed: - |
| 54 | Element pre-air cleaner, (Make: Kirloskar or equivalent as approved by GE.) |
| 55 | Element air cleaner fine, (Make: Kirloskar or equivalent as approved by GE.) |
| 56 | Kit super BYP filter element, (Make: Kirloskar or equivalent as approved by GE.) |
| 57 | Kit Fuel filter and 'O' ring, (Make: Kirloskar or equivalent as approved by GE.) |
| 58 | Element lubricating oil filter, (Make: Kirloskar or equivalent as approved by GE.) |
| 59 | Inhibitor corrosion, (Make: Kirloskar or equivalent as approved by GE.) |
| 60 | Engine oil Valvoline Premium Blue 7600, 210 ltr in non returnable container (Make: Kirloskar or equivalent as approved by GE.) |
| 61 | Coolant for DG Set in 5 Ltrs non-returnable Can |
| 62 | Sidtile water for battery |
| 63 | M&L for earthing with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 32 x 6 mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work & excavation in any type of soil, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed. NOTE: Earthing lead & protection pipe from earth electrode to test point upto 7.5 Rm is deemed to be included in the quoted uint rate. |
| 64 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and as directed. |
| 65 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. in any type of soil complete all as specified and as directed. |
| 66 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point in any type of soil complete all as specified and as directed. |
| 67 | M&L for dry river Sand filling in trenches including punning down consolidation in any type soil complete all as specified and as directed. NOTE: Punned thickness shall be measured for payment purpose. |
| 68 | S&F in repairs tubes, 'light grade', galvanised, with all fitting; laid in trenches for cable protection of the following sizes complete all as specified and directed: - |
| 69 | 80 mm dia nominal bore |
| 70 | 50 mm dia nominal bore |
| 71 | M&L for brick protection of cables in trenches with old size sub-class 'B' bricks complete all as specified and as directed. |
| 72 | M&L for cutting of existing bituminous metal road for laying of cables including demolition of road surface, excavation from bottom level of road upto a depth of 0.55 m from road surface and returning filling of excavated earth and making good the road surface with PCC type C2 (1:3:6) with 40 mm graded stone aggregates upto a depth of 10 cm from road surface and removing of excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point in any type of soil complete all as specified and as directed.[Note: Laying of cable/ protection pipe will be measured and paid under separate item of this schedule] |
| 73 | Supplying, laying and testing of XLPE insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade including taking out of old cables of the following sizes complete all as specified and as directed: - |
| 74 | Cross-sectional area 240 sq mm 3.5 core |
| 75 | Cross-sectional area 185 sq mm 3.5 core |
| 76 | Cross-sectional area 120 sq mm 3.5 core |
| 77 | Cross-sectional area 95 sq mm 3.5 core |
| 78 | M&L for taking out of existing LT UG cable and re-laying/ shifting the same for the following size of cables complete all as specified and as directed.: -[Note: - Earth work will be measured and paid under separate item of this schedule] |
| 79 | 95 to 120 sqmm 3.5 core |
| 80 | 185 sqmm 3.5 core |
| 81 | 240 sqmm 3.5 core |
| 82 | Taking out of damage canopy of any size of DG set and fixing the new accoustic encloser and sound proof not less then 1.6 mm thickness of CRCA sheet for outer encloser canopy and internally lined to meet requirement. The lining material shall be rockwool covered with GI perforated sheet, sound insulation shall be 50 mm thickness., silencer, door lock of existing size and model of DG set complete all as specified and as directed. |
| 83 | M&L for cutting and dismaintling of damage inner area of any capacity of DG set and fabrication and fixing/ welding the new inner perforated sheet of canopy in replace of damage area along with suitable size of steel rock wool complete all as specified and as directed. |
| 84 | Taking out FIP for upto 500 KVA capacity by DG set from engine assembly shifting of FIP to work shop overhauling of FIP complete after repalcment of unserviceable parts callibration of FIP returning from workshop refixing to engine assembly including replacement of nozzles and cleaning of nozzle pipes complete all as specified and directed Note : (i) The cost of cleaning materials like kerosine oil cotton waste etc and lubricating item like mobile oil grease etc and patty spare parts required for this job are deemed inclusive in the quoted unit rate. (ii) Nozzles and 'O' rings shall be measued and paid separatly as \\" Supply only\\". |
| 85 | S&F in repairs battery lead copper flexible cable PVC insulated 650W 25 sqmm single core of length 1.5 metre long with one side connected (welded/soldered) with male type batery terminal and other end connected with female type terminal complete all as specified and as directed. |
| 86 | All as per BOQ Serial item No 18 above but length 1.00 mtr complete all as specified and as directed. |
| 87 | Taking out alternator dynamo from the 500 KVA DG set, dismantling all the parts, cleaning and serviceing including replacement of petty spare parts, reclosing and refixing to its original position complete all as specified and as directed. |
| 88 | Taking out alternator dynamo form the 200 KVA DG set, dismantling all the parts cleaning and serviceing including replacement of petty spare parts, reclosing and refixing to its original position complete all as specified and as directed. |
| 89 | Cleaning of diesel tank by opening out of diesel pipe line, taking out of diesel, removal of all the sludge cleaning with caustic soda solution, then with fresh water drying up and refitting resetting of the tank to its original position up to 500 KVA DG set complete all as specified and as directed. |
| 90 | Cleaning of diesel tank by opening out of diesel pipe line, taking out of diesel, removal of all the sludge, cleaning with caustic soda solution, then with fresh water drying up and refitting resetting of the tank to its original position of 320 KVA DG set complete all as specified and as directed. |
| 91 | Cleaning of diesel tank by opening out of diesel pipe line, taking out of diesel, removal of all the sludge, cleaning with caustic soda solution, then with fresh water drying up and refitting resetting of the tank to its original position of 750 KVA DG set complete all as specified and as directed. |
| 92 | Cleaning of diesel tank by opening out of diesel pipe line, taking out of diesel, removal of all the sludge, cleaning with caustic soda solution, then with fresh water drying up and refitting resetting of the tank to its original position of 1000 KVA DG set complete all as specified and as directed. |
| 93 | S&F in repairs radiator hose complete set as per existing shape and size of 200 KVA DG set complete all as specified and as directed. |
| 94 | Scrapping out existing paint, cleaning of surface and M&L for spray painting with two coats of synthetic enamel paint (colour/shade as approved) on 100 KVA DG set including diesel tank complete all as specified and directed . |
| 95 | All as per BOQ Serial item No 27 above but of capacity 200 KVA DG Set complete all as specified and as directed. |
| 96 | All as per BOQ Serial item No 27 above but of capacity 320 KVA DG Set complete all as specified and as directed. |
| 97 | Taking down unservisable autometic battery Charger including disconnecting of all connection and replacing with new autocut battery charger suitable for charging up to 24 Volt 180 AH (2X12 Volt ) battery complete all as specified and as directed. |
| 98 | Excavating in post holes (or similar holes) each n exc 0.50 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm in hard dense soil complete all as specified and as directed. |
| 99 | M&L for PCC ( 1:5:10 ) Type D -2 using 40 mm graded stone aggregates as in foundation complete all as specified and as directed. |
| 100 | M&L for 50 mm thick cement concrete type B1,1:2:4 (20mm graded stone aggregates) as in floors finish even and smooth etc complete all as specified and as directed. |
| 101 | M&L for brick work with sub class `B` bricks, old size, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) including demolition of exixting brick work any type complete all as specified and as directed. |
| 102 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed. |
| 103 | M&L for rendering 15 mm thick, set in cement mortatr (1:4), as on brick/concrete surface etc finish even and smooth without using extra cement complete all as specified and as directed. |
| 104 | Preparation on new plastered surfaces of wall and M&L for applying two coats of cement base paint over a coat of primer upto four storey high bldg complete all as specified and directed. |
| 105 | M&L for providing cement concrete type B-1,1:2:4 (using 20 mm graded stone aggregates) as in benching concrete, coping ,hold fast etc including demolition of existing pcc complete all as specified and directed. |
| 106 | M&L for 100 mm thick PCC (1:4:8) type D-2 (40 mm graded stone aggregates) as in flooring, finished even and smooth with using extra cement including demolition of existing pcc complete all as specified and directed. |
| 107 | M&L for 25 mm thick sand cushion under paver block or interlocking tiles floor including watering and consolidation complete all as specified and as directed |
| 108 | M&L for 80 mm thick coloured machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658- 2006 M-40 Grade with grey cement and no pigment including demolition of exixting paver blocks complete all as specified and as directed. |
| 109 | S&F in repairs Steel work in MS tubes (round/square) including special shaped washer, necessary FI angle iron if required to complete the works as in truss,purlins, rafter etc complete using ERW or induction butt welded tubes conforming to IS-1161-1979 graded St-240 complete all as specified and directed. |
| 110 | S&F 11-15mm dia of shank mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n exc 10cm long complete all as specified and as directed. |
| 111 | S&F in repairs Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/chadding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 112 | S&F Pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/chadding to wall, fixed with self tapping screws as in ridges complete all as specified and as directed. |
| 113 | Preparation of new steel surfaces of any description over 10cm width or girth and M&L for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. Please Enable Macros to View BoQ information |