| 1 | Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling, ramming the foudation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/l. |
| 2 | Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50Mand lift of 1.5M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) |
| 3 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including' cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement complacted volume). |
| 4 | Providing designation 75 A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l. |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plinth level - 1:3:6 (1 cement : 3 coarse sand (zone - III): 6 graded stone aggregate 20mm nominal zie) |
| 6 | Providing designation 75A brick work in C.M (1: 6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. |
| 7 | Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x3\\") in C.M. (1:6) in foundation and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 8 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering and shuttering, finishing and reinforcement - all work upto plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III): 3 graded stone aggregate 20mm nominal zie) |
| 9 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and structs etc. above plinth level upto floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III) : 3 graded stone aggregate 20mm nominal size) |
| 10 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases, above plinth level upto floor five level, excluding the cost of cenetering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III): 3 graded stone aggregate 20mm nominal size) |
| 11 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size). |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 13 | Foundations, footings, bases of columns, etc. for mass concrete |
| 14 | Suspended floors, roofs, landings, balconies and access platform |
| 15 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 16 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 17 | Providing tor steel reinforcement of 8mm. dia. rods as per approved design and drawing with cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position (excluding carriage of bars to work site) all complete as per building specification and direction of E/l. TMT FE 500 ( only valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Steels Ltd. Bokaro, & Vizag (RINL) |
| 18 | Providing tor steel reinforcement of 10,12,16mm . dia. rods as per approved design and drawing with cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position (excluding carriage of bars to work site) all complete as per building specification and direction of E/l. TMT FE 500 ( only valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Steels Ltd. Bokaro, & Vizag (RINL) |
| 19 | 10mm dia - |
| 20 | 12 to 25mm dia |
| 21 | Supplying, fitting and fixing fully glazed steel door, window or ventilations of standard rolled 'Z' and mullion steel sections and size as per IS-1038 joints met and welded with 100X16X3mm M.S. lugs fixed in cement concrete (1:2:4) block 15X10X10cm, size including cost of oxidised iron fittings, with hinges, handle per steps, catch springs, 3mm thick plain glass panes with Aluminimum beads and inner frame fixed with lugs with 20mm long 6.3mm G.I. counter sunk machine screw and nuts and applying a coat of red lead paint carriage to work site hoisting and placing in position in all storys and taxes all complete as per building specification and direction of E/I. |
| 22 | Supplying and fixing rolling shutters of approved makemade of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets side guidesand arnagements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.50cm long wire sprinings manufactured from high tensile steel wire of adequate strength conforming to IS: 4454-Part 1 and M.S. top cover ofrequired thickness for rolling shutters - 80X1.25mm M.S. laths with 1.25mm thick top cover |
| 23 | Extra for providing mechanical device chain and crank operation for operating rolling shutters. Exceeding 10M2 and upto 16.80M2 in the area |
| 24 | Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth , carriage of grill to work site, hoisting as per building specification and direction of E/l. (where materials is not supplied by the deptt.) |
| 25 | Providing and fixing fan hook of 16mm dia M.S. bar 1 metre long bent to required size and shape, placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/l. (where material is not supplied by deptt.) |
| 26 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc,. Including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 27 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50X50mm including strengthing with 2mm dia wire or nuts, bolts and washers as required complete as per the direction of the Engineer-in-charge - made of G.I. wire of dia 4mm, PVC coated to achieve outer dia not less than 5mm in required colour and shade. |
| 28 | 52mm thick cement concrete flooring with concrete hardener topping under layer 40mm thick cement concrete 1:2:4) 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 ltrs per 50 kg. of cement or as per manufactuers specification This includes cost of cement slurry but excluding the cost of nosing of steps etc. complete |
| 29 | Providing 50mm thick cement concrete flooring (1:2:4) with 20mm to 6mm size graded stone chips finished with flooring coat of neat cement in panels including cost of curining finishing the surface smooth by rubbing with carborandum stone taxes and royalty with all complete as per building specification and direction of E/I. |
| 30 | Extra for providing and fixing 30X4mm glass strips in joints of flooring , complete job as per specification and direction of E/I. |
| 31 | Providing and laying 25mm thick kotah stone tiles in risers of steps skirting and pillars of approved size texure and colour laid over 12mm thick cement mortar (1;30 and joined with grey cement slurry mixed with pigment to match the shade of the slab including rub bing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 32 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. |
| 33 | Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. |
| 34 | Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5with 5% cico or any other approved water proofing compoundincluding taxes and royalty all complete as per building specification and direction of E/l. |
| 35 | Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 36 | Finishing walls with acrylic sommth exterior paint of required shade: New work (two or more coats applied @ 1.67ltr/10sqm) over and including priming coat of exterior primer applied @ 2.20kg/10sqm. |
| 37 | Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direciton of E/l. |
| 38 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc,. Including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 39 | Providing and fixing at all height, levels and locations colour finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling.tapping stainless steel screws M6, 50mm long with 3mm EPDM seal washer eetc. all inclusive of labour, scaffolding, T & P and sundries etc. complete as per directions of the Engineer-in-charge. (cost of truss/frame work shall be paid separately) - 0.56mm, Aluminium Color coated troughed profile with centre to center pitch of 200mm, depth of 32mm, overall profile width 1092mm, cover width 1000mm |
| 40 | Providing and fixing of pre-coated colour or mill finish aluminium roofing accessories in 0.71mm thickness , alloy 31500 (IS designation) aluminium alloy 3004 (ISO designation) for colour coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of sixe 6X50mm wutg 3mm thick EPDM seal and SS plain washer complete: |
| 41 | Precoated/mill finish aluminium ridges plain (500-600mm) |
| 42 | Precoated/mill finish aluminium gutter (600mm over all girth) |
| 43 | Providing & fixing on wall face unplasticised - Rigid P.V.C. rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . Single socketed pipes. 110 mm dia |
| 44 | Providing and fixing on wall face unplaqsticised- PVC moulded fitting/ accessories for unplaqsticised- PVC rain water pipes confirming to IS: 13592 TYPE A,including jointing with seal ring confirming to IS: 5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 45 | Bend 87.5 degree - 110X110X110mm |
| 46 | Shoe plain -110mm |
| 47 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less thaN 440 grams. |
| 48 | Providing and fixing unplasticised PVC pipe clips of approved design to unplasticised PVC rain water pipes by means 50X50X50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand) and making good the wall etc. complete - 110mm |
| 49 | Providing 250 mm wide BRICK DRAIN in cement mortar (1:6) with avarage 150mm. Clear depth and 250 mm apron including cost of earthwork involved with 75m cement concrete (1:4:3) over one brick designation 75A, flat soling in proper grade and slope at the base , the drain dully plastered in C.M.(1:3) with puning over exposed surface all complete as per building specification and direction of E/I. |
| 50 | Providing and fixing stainless steel (grade 304) railing made of Hollow tubes, channels, plates etc,. Including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessry stainless steel nuts and bolts complete i/c fixing the railing with necessary accessories & stainless steel dash fasterners, stainless steel bolts etc. of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasterners etc,.) |
| 51 | Carriage of materails |
| 52 | Bricks - Lead - 10km. |
| 53 | Sand - Lead 15km |
| 54 | Chips - Lead 15km |
| 55 | Metal - Lead 15km. |
| 56 | Making soak pit 2.5M diameter 3 mtr. deep with 45X45cm dry brick honey comb shaft with brciks of class designation 75 and S.W. drain pipe 100mm diamter 1.8 mtr. long complete as per standard design with FPS bricks |
| 57 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS 8931, 15mm dia nominal bore of approved brand C.P. fittings |
| 58 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i.e fixing the pipe with clamps at 1Mtr. Spacing. This includes jointing of the pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I. Concealed work including cutting chases and making good the walls etc. |
| 59 | 20mm nominal bore |
| 60 | 25mm nominal bore |
| 61 | 32mm nominal bore |
| 62 | Providing & fixing on wall face unplasticised - Rigid P.V.C. pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . Single socketed pipes. 110 mm dia |
| 63 | Providing and placing on terrace (at all floor levels) (PVC) Polyethylene water storage tank ISI 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 64 | ELECTRCIAL WORK |
| 65 | Point Wiring in PVC Conduit, with Modular type Switch: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size of GI box etc as required. |
| 66 | Supply and Fixing Light Plug Point with Modular Type Accessories: Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch, connection, painting etc as required. |
| 67 | Supply and Fixing Light Plug Point with Modular Type Accessories: Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular type switch, connection, painting etc as required. |
| 68 | Circuit / Sub-main wiring in PVC Conduit: Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required. |
| 69 | 2x1.5 Sqmm + 1x1.5 sqmm earth wire |
| 70 | 2x2.5 Sqmm + 1x2.5 sq mm earth wire |
| 71 | 2x4 Sqmm + 1x4 sq mm earth wire |
| 72 | S/F TP MCB DB:- Supplying and fixing of following way, three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (Without MCB/RCCB/ISOLATOR). (All TP MCB DB shall be as per IS:8623) |
| 73 | 4 Ways (4+12 ways) double door |
| 74 | S/F 'C' series MCB:- Supplying and fixing 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required. |
| 75 | 6/32A Single Pole |
| 76 | 6/32A TPN MCB |
| 77 | S/F Ceiling Rose: Supplying and fixing 2 pin ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 78 | ITC Exhaust Fan upto 450 mm sweep: installation of exhaust fan upto 450 mm sweep in the existing opening, including making the hole to cut the size of the above fan, making good the damage, including connection, testing, commissioning etc as required. |
| 79 | S/F Batten / Angle Holder: Supplying and fixing batten / angle holder including connection etc as required. |
| 80 | S.I.T.C of following rating surface mounted LED tube light fittings suitable for 230V, 50Hz, single phase supply etc. complete as required - 20/22W. LED tube light |
| 81 | Bulk head fitting with 9/10Watt CFL/LED |
| 82 | Supplying, 15/16 Watt LED bulb of approved make |
| 83 | Supplying Exhaust fan of 12\\" (300mm) of aproved make |
| 84 | 450MM (18\\") metal body wall fan with speed regulator suitable for single phase 220V,50hz, AC supply |
| 85 | S.I.T.C. of following rating LED street lighting luminarie die cast housing and toughened glass cover (IP-66 portion) in existing pole/pipe for supply voltage 100-270V. AC, 50Hz. Luminaire shall be confirm to IS:10322 part - 5/section 3 and shall be complete with all necessary accessories as required - 60W LED street light |
| 86 | Provioding and laying 1.1 KV grade aluminium armoured cable as per IS 1554 (Part I) heavy duty all cost complete including cost of brass compression gland, cable jointing and end termination as per specification and direction f E/I. |
| 87 | 3.5 core, 50 sq.mm |
| 88 | 3.5 core, 25 sq.mm |
| 89 | BOREWELL |
| 90 | Costs of drilling 200mmX165mmX125mtr. Deep borewell in all kinds of soil and rock in rural area for installation of pump set with Hydraulic DTH rig machine, all complete including supplying all materials, tools, drilling rig, Air compressor and equipments, as well as fuel lubricants and cost of transportation of rig machine and other vehicles upto the site |
| 91 | From 0-50 mtr. |
| 92 | Above 51 mtr.to 125 mtr |
| 93 | Above 125 mtr. |
| 94 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia conforming to IS : 12818, including required hire and labour charges fittings & accessories etc. all complete for all depths, as per direction of Engineer-in-charge - 200mm nominal size dia |
| 95 | Gravel packing in tube well construction in accordance with IS : 4097, including providing gravel fine/medium/coarse, in required grading & size as per actual requirement, all complete as per direction of Engineer-in-charge |
| 96 | Development of tube well in accordance with IS 2800 (part 1) and IS: 11189 to establish maximum rate of usable water yield without sand content (beyond permissible limit) with required capacity air compressor, running the compressor for required tile till well is fully developed, measuring yield of well by \\"V\\" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, colleting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete including hire & labour charges of air compressor, tools & accessoires etc. all as per requirement and direction of Engineer-in-charge. |
| 97 | Providing & fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/casing pipe, removable as per requirement, all complete for borewell of 200mm dia |
| 98 | Providing and fixing M.S. clamp of required dia to the top of casing/housing pipe of tubewell as per IS:2800 (Part-1) including necessary bolts & nuts of required size complete |
| 99 | Providing and fixing ball plug/bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS :2800 (Part-1) 200mm dia |
| 100 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pioes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement trenching, refilling & testing of joints complete as per direction of Engineer in charge |
| 101 | 50mm nominal outer dia pipes |
| 102 | Supplying submersible pumps sets confirming to IS:8034 and motor confirming to IS:9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller, motor suitable for working on 415V+10%, 3PH. 50HZ, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thrust, water proof winding shall be provided. the pump set shal be suitable for direct couplings, pump shall have suitable outlet as per manufacture design. Anti thrust stream lined non return valve shall be provided with pump. 3 mtr. submrsible copper conductor cable in single/double run shall be provided with each pump. |
| 103 | Submersible pump set 100mm dia (with polypropylene/noryl impeller) upto 20 stage - 3.0 HP |
| 104 | Add 18% Gst |
| 105 | Add 1% Labour Cess Please Enable Macros to View BoQ information |