| Sl. No. | Item Description |
| 1 | Shifting of Meters/street lights from item S.no. 1 to S.No.07 |
| 2 | Shifting of Single-Phase Consumer Smart/ Convential Meter alongwith mounting structure from existing pole to New Pole & connecting Input Supply to meter from SMDB/LTDB Boxes & output to consumer Distribution Board/ Service Line. |
| 3 | Shifting of Three-Phase Smart/ Convential Meter alongwith mounting structure from existing pole to New Pole & Connecting Input Supply to meter from SMDB/LTDB Boxes & output to consumer Distribution Board/ Service Line |
| 4 | Connecting Input Power Supply of Single-Phase Smart/ Convential Meter installed on existing pole from SMDB/LTDB Boxes & output to consumer Distribution Board/ Service Line. |
| 5 | Connecting Input Power Supply of 3-Phase Smart/ Convential meter installed on existing pole from SMDB/LTDB Boxes & output to consumer Distribution Board/ Service Line. |
| 6 | Shifting of Street Lights alongwith mounting structure from existing pole to New Pole & connecting Input Supply to light from SMDB/LTDB Boxes |
| 7 | Connecting Input Power Supply of Street Light installed on existing pole from SMDB/LTDB Boxes & output to light |
| 8 | Supply, installation,testing and commissining of insulating Piercing connectors Connecting Street lights from bare conductor to the cable. (Including IPC) |
| 9 | (MATERIALS Only) : SUPPLY/PROVIDING OF MATERIALS from item SL No 8 to 384 |
| 10 | Key Materials |
| 11 | Steel Tubular Poles Of Sizes |
| 12 | ST Pole 13 mtr. Long (ST-410 SP69) |
| 13 | ST Pole 11 mtr. Long (ST-410 SP56) |
| 14 | ST Pole 9 mtr. Long (ST-410 SP33) |
| 15 | ST Pole 8 mtr. Long (ST-410 SP15) |
| 16 | PCC Poles Of Sizes |
| 17 | PCC Pole 9 mtr. Long (WL =300 Kg) |
| 18 | PCC Pole 8 mtr. Long (WL =250 Kg) |
| 19 | ACSR Conductor of Sizes |
| 20 | 0.1 ACSR Conductor (Dog) |
| 21 | 0.05 ACSR Conductor (Rabbit) |
| 22 | 0.03 ACSR Conductor (Weasel) |
| 23 | 11 KV Gang Operating, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type comprising of 9 No. insulators, pipes and lock pad etc complete job (Polymer Type) |
| 24 | 11 KV Gapless Surge Arrestor, 9 kV, 10 kA, Lighting Arresor with polymer housing, Stn. Type |
| 25 | 11 KV Gapless Surge Arrestor, 9 kV, 10 kA, Lighting Arresor with porcelain type housing, Stn. Type |
| 26 | 11 KV Horn Gap Fuse Set 3-Phase 200 Amp (Polymer Type) |
| 27 | 11 KV Horn Gap Fuse Set 3-Phase 200 Amp (porcelain type) |
| 28 | G.I.Wire No. 8 SWG & 6 SWG |
| 29 | Guy Insulators (11 KV) |
| 30 | Pole Collars / Back Clamp of 50x8mm galvanized Flat Iron |
| 31 | GI Pipe 40 mm |
| 32 | GI Pipe 150 mm |
| 33 | GI Barbed Wire for Anticlimbing |
| 34 | Anticlimbing Devices with Clamp |
| 35 | 11 KV Danger Plate with Clamp |
| 36 | Galvanized Nuts and Bolts of sorts |
| 37 | Galvanized Channel Iron Cross Arm/angle brace of Sizes |
| 38 | Galvanized V Cross-Arms duly fabricated of size 75x40x6mm Channel Iron Cross Arm with 04 No. (50x50x6mm) welded flat iron plates as per Drg. No. CE/P&P/DRG/2022/11KVL001) |
| 39 | Pole bracket (F-Top for v cross configuration)s as per Drg. No. CE/P&P/DRG/2022/11KVL001) |
| 40 | Protection Items (SP MCB C-Curve Series of breaking capacity 10 kA) |
| 41 | 6 Amp |
| 42 | 10 Amp |
| 43 | 16 Amp |
| 44 | 25 Amp |
| 45 | 32 Amp |
| 46 | 40 Amp |
| 47 | 63 amp |
| 48 | 100amp |
| 49 | Protection Items (DP MCB C-Curve Series of breaking capacity 10 kA) |
| 50 | 6 Amp |
| 51 | 10 Amp |
| 52 | 16 Amp |
| 53 | 25 Amp |
| 54 | 32 Amp |
| 55 | 40 Amp |
| 56 | 63 Amp |
| 57 | 100 Amp |
| 58 | Protection Items (TP MCB C-Curve Series, of breaking capacity 10 kA) |
| 59 | 16 Amp |
| 60 | 25 Amp |
| 61 | 32 Amp |
| 62 | 40 Amp |
| 63 | 63 Amp |
| 64 | 100 Amp |
| 65 | Protection Items (TP MCCB- Adjustable) |
| 66 | 32 Amp (breaking capacity 15 kA) |
| 67 | 40 Amp (breaking capacity 15 kA) |
| 68 | 63 Amp (breaking capacity 15 kA) |
| 69 | 100 Amp (breaking capacity 15 kA) |
| 70 | 160 Amp (breaking capacity 25 kA) |
| 71 | 200 Amp (breaking capacity 25 kA) |
| 72 | 320 Amp (having breaking capacity of 35 kA) |
| 73 | 400 Amp (having breaking capacity of 35 kA) |
| 74 | 630 Amp (having breaking capacity of 35 kA) |
| 75 | Protection Items (TPN MCCB- Thermal and Magnetic -Adjustable) Ics =100% Icu as per IEC 60947-2 |
| 76 | 32 Amp (breaking capacity 15 kA) |
| 77 | 40 Amp (breaking capacity 15 kA) |
| 78 | 63 Amp (breaking capacity 15 kA) |
| 79 | 100 Amp (breaking capacity 15 kA) |
| 80 | 160 Amp (breaking capacity 25 kA) |
| 81 | 200 Amp (breaking capacity 25 kA) |
| 82 | 320 Amp (having breaking capacity of 35 kA) |
| 83 | 400 Amp (having breaking capacity of 35 kA) |
| 84 | 630 Amp (having breaking capacity of 35 kA) |
| 85 | Enclosure of suitable sizes complete for fixing of TP MCCB / TPN MCCB adjustible along with clamps for the following : |
| 86 | 32 Amp (breaking capacity 15 kA) |
| 87 | 40 Amp (breaking capacity 15 kA) |
| 88 | 63 Amp (breaking capacity 15 kA) |
| 89 | 100 Amp (breaking capacity 15 kA) |
| 90 | 160 Amp (breaking capacity 25 kA) |
| 91 | 200 Amp (breaking capacity 25 kA) |
| 92 | 320 Amp (having breaking capacity of 35 kA) |
| 93 | 400 Amp (having breaking capacity of 35 kA) |
| 94 | 630 Amp (having breaking capacity of 35 kA) |
| 95 | LT Distribution box made with 2mm CRCA Sheet with bus-bars of suitable ratings along with TP- MCCBs and Link Disconnectors 200 Amps for various capacity transformers. |
| 96 | LT Distribution Box for 25 kVA DTR with 40 Amp MCCB 3P 10 kA for incomer & 25 Amp MCCB 3P 16 kA/10 kA 1 No. each (=2No.) for Outgoing Circuits. 16 Amp Single Pole MCB 02 No. also included. (Aluminium Bus Bar 25x8 for Phase and Neutral also) |
| 97 | LT Distribution Box for 63 kVA DTR with 100 Amp MCCB 3P 10 kA for incomer & 100 Amp MCCB 3P 10 kA 1 No.s for Outgoing Circuits and 63 Amp 02 No. & 200 Amp 06 No.Outgoing Link Disconnectors. 16 Amp Single Pole MCB 02 No. also included. (Aluminium Bus Bar 25x8 for Phase and Neutral also) |
| 98 | LT Distribution Box for 100 kVA DTR with 160 Amp MCCB 3P 10 kA for incomer & 100 Amp MCCB 3P 10 kA 2 No.s for Outgoing Circuits and 200 Amp 06 No. Outgoing Link Disconnectors. 16 Amp Single Pole MCB 02 No. also included. (Aluminium Bus Bar 25x8 for Phase and Neutral also) |
| 99 | LT Distribution Box for 200 kVA DTR with 315 Amp MCCB 3P 35 kA for incomer & 200 Amp MCCB 3P 16 kA 2 No. and 160 Amp MCCB 3P 16 kA 1 No.s for Outgoing Circuits and 200 Amp 09 No. Outgoing Link Disconnectors. 16 Amp Single Pole MCB 02 No. also included. (Aluminium Bus Bar 40x10 for Phase and Neutral also) |
| 100 | LT Distribution Box for 250 kVA DTR with 400 Amp MCCB 3P 35 kA for incomer & 200 Amp MCCB 3P 16 kA 2 No. and 160 Amp MCCB 3P 16 kA 1 No.s for Outgoing Circuits and 200 Amp 09 No. Outgoing Link Disconnectors. 16 Amp Single Pole MCB 02 No. also included. (Aluminium Bus Bar 40x10 for Phase and Neutral also) |
| 101 | LT Distribution Box for 400 kVA DTR with 630 Amp MCCB 3P 35 kA for incomer & 400 Amp MCCB 3P 16 kA 2 No.s for Outgoing Circuits and 200 Amp 06 No. Outgoing Link Disconnectors. 16 Amp Single Pole MCB 02 No. also included. (Aluminium Bus Bar 40x15 for Phase and Neutral also) |
| 102 | LT Busbar 100 A, 440 V, TPN Tinned copper busbar all insulated, Staggered form with provision for tapping all the three phases & neutral/ Frame of suitable size |
| 103 | LT Busbar 200 A, 440 V, TPN Tinned copper busbar all insulated, Staggered form with provision for tapping all the three phases & neutral/ Frame of suitable size |
| 104 | Manual Change Over Switch 63 Amp TPN |
| 105 | Manual Change Over Switch 100 Amp TPN |
| 106 | Manual Change Over Switch 200 Amp TPN |
| 107 | 3-phase Onload Changeover switch 100 amp. |
| 108 | Aluminium Thimbles Suitable for Cables of Sizes (Long Barrel Type) |
| 109 | 16 mm sq |
| 110 | 25 mm sq |
| 111 | 35 mm sq |
| 112 | 50 mm sq |
| 113 | 70 mm sq |
| 114 | 95 mm sq |
| 115 | 120 mm sq |
| 116 | 150 mm sq |
| 117 | 185 mm sq |
| 118 | 240 mm sq |
| 119 | 300 mm sq |
| 120 | 400 mm sq |
| 121 | 630 mm sq |
| 122 | Copper Thimbles Of Sizes |
| 123 | 16 mm sq |
| 124 | 25 mm sq |
| 125 | 35 mm sq |
| 126 | 50 mm sq |
| 127 | Aluminium Solderless Clamps Suitable for DT's of Ratings |
| 128 | 250/400 kVA (for 19mm Bushrod) |
| 129 | 630 kVA (for 32 mm Bushrod) |
| 130 | Self Adhesive PVC Electrical Insulation Tape 1.80 cmx7mx0.125mm (ISI Mark) |
| 131 | 11 KV Polymeric composite Pin Insulator 12 kV, 5 kN, Lighting Impulse 75 kV Positive and 80 kV Negative, creepage distance 320 mm |
| 132 | 11 kV Polymeric composite Disc Insulator 12 kV, min failing load 45 KN, Lighting Impulse 75 kV Positive and 80 kV Negative, creepage distance 320 mm, conforming to ISO 9001, 2008 standards, working temperature -10 to 40 deg Cel having 16 mm dia fiber rod with fittings suitable for ACSR conductor ( 100 sqmm/50 sqmm) |
| 133 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2No.), anchor plate (450x 450 x 8 mm), nut-bolts, 2 No. turn-buckles, 1.8m long,20 mm diameter solid GS stay rod & 7/4 mm dia GI stranded wire complete |
| 134 | GI Pole Support Clamp for AB Cable including GI Nut and Bolts with washers suitable for ST Poles |
| 135 | GI Pole Support Clamp for AB Cable including GI Nut and Bolts with washers suitable for PCC Poles |
| 136 | Eye Hook for holding HT/LT AB cable ( as per Dwg) |
| 137 | Suspension Clamp for HT/LT AB cable |
| 138 | Dead End/Tension Clamp for HT/LT AB cable |
| 139 | 11 KV Isolator, double break, 3-pole, 630 Amp, horizontal mounting Type, with Earth Switch. |
| 140 | Guard Netting Complete including GI Channel X-arm including clamps and braces, galvanized nuts and bolts, GI Wire 8 or 6 SWG, Eye Bolts etc (complete) |
| 141 | PG (Parallel Groove) Clamps for ACSR Conductor |
| 142 | 0.05 ACSR |
| 143 | 0.1 ACSR |
| 144 | LT Part including LT Cabling |
| 145 | LT Shackle Insulators 16 KN 100 mm |
| 146 | GI U/D-Clamps for LT Shackle Insulators with 01 No. MS Bolt |
| 147 | GI Muki Clamp for LT Shakckle using (50x6 ) mm galvanized flat iron suitable for ST Pole with back clamp and galvanized nuts and bolts |
| 148 | LT fuse set comprising of requisite aluminium bus bar mounted on LT polymer insulator assembled on galvanized channel iron frame including necessary clamps ( Strictly as per drawing attached) |
| 149 | Piercing Connector for DB connection from main ABC to DB (main line 35-120 sqmm/branch line section 35-50 sqmm) |
| 150 | Piercing Connector for street light connections (main line 35-120 sqmm/branch line section 4-25 sqmm) |
| 151 | Piercing connector for ABC to ABC Tee connection (main line 35-120 sqmm/branch line section 70-120 sqmm) insulated |
| 152 | 3-phase Pole mounted Distribution Box (outdoor type) of size (418x300x120)mm with Al Bus Bar Outdoor type Distribution Boardi) Enclosure sheet thickness 20 swg CR MS Sheeetii) Dimensions (Not less than) with Height 418 mm, Depth 120 mm, Width 300 mm with inclined topiii) Bus Bar Material Almuniium with Heak shrinkable sleeves)iv) Busbars 20x15mm for phase as well as neutral v) Clearence between phases/neutral 40 mm (min)vi) U Latch arrangement on door with 1 hole for padlockvii) Incoming and outgoing cable holes at Bottom with rubber gromet) |
| 153 | 1-phase Pole mounted Distribution Box of size (285x225x120)mm with Al Bus Bar Outdoor type Distribution Boardi) Enclosure sheet thickness 20 swg CR MS Sheeetii) Dimensions (Not less than) with Height 285 mm, Depth 120 mm, Width 225 mm with inclined topiii) Bus Bar Material Almuniium with Heak shrinkable sleeves)iv) Busbars 20x15mm for phase as well as neutral v) Clearence between phases/neutral 40 mm (min)vi) U Latch arrangement on door with 1 hole for padlockvii) Incoming and outgoing cable holes at Bottom with rubber gromet) |
| 154 | Aluminium Jointing Sleeves |
| 155 | LT Line Spacer - 2 Phase 3 Wire |
| 156 | LT Line Spacer - 3 Phase 4 Wire |
| 157 | 1-Core, 1.1 KV Grade, XLPE Insulated Stranded (Un-Armoured Cable) Aluminium Conductor FRLS (Flame Retardant Low Smoke) Type |
| 158 | 50 mm sq |
| 159 | 70 mm sq |
| 160 | 95 mm sq |
| 161 | 120 mm sq |
| 162 | 185 mm sq |
| 163 | 240 mm sq |
| 164 | 300 mm sq |
| 165 | 400 mm sq |
| 166 | 630 mm sq |
| 167 | 1-Core, 1.1 KV Grade, XLPE Insulated Stranded (Armoured Cable) Aluminium Conductor FRLS (Flame Retardant Low Smoke) Type |
| 168 | 50 mm sq |
| 169 | 70 mm sq |
| 170 | 95 mm sq |
| 171 | 120 mm sq |
| 172 | 185 mm sq |
| 173 | 240 mm sq |
| 174 | 300 mm sq |
| 175 | 400 mm sq |
| 176 | 630 mm sq |
| 177 | 2 Core , 1.1 KV Grade XLPE Un-Armoured Aluminium Cable FRLS |
| 178 | 10 mm sq 2-Core Cable |
| 179 | 16 mm sq 2-Core Cable |
| 180 | 25 mm sq 2-Core Cable |
| 181 | 35 mm sq 2-Core Cable |
| 182 | 50 mm sq 2-Core Cable |
| 183 | 2-Core, 1.1 KV Grade XLPE Insulated Aluminium Conductor Armoured FRLS Type |
| 184 | 10 mm sq |
| 185 | 16 mm sq |
| 186 | 25 mm sq |
| 187 | 35 mm sq |
| 188 | 50 mm sq |
| 189 | 70 mm sq |
| 190 | 95 mm sq |
| 191 | 120 mm sq |
| 192 | 3½-Core, 1.1 KV Grade XLPE Insulated Stranded (Un-Armoured Cable) Aluminium Conductor, FRLS (Flame Retardant Low Smoke) Type |
| 193 | 35 mm sq |
| 194 | 50 mm sq |
| 195 | 70 mm sq |
| 196 | 95 mm sq |
| 197 | 120 mm sq |
| 198 | 185 mm sq |
| 199 | 240 mm sq |
| 200 | 300 mm sq |
| 201 | 400 mm sq |
| 202 | 630 mm sq |
| 203 | 3½-Core, 1.1 KV Grade XLPE Insulated Armoured Cable Aluminium Conductor, FRLS (Flame Retardant Low Smoke) Type |
| 204 | 35 mm sq |
| 205 | 50 mm sq |
| 206 | 70 mm sq |
| 207 | 95 mm sq |
| 208 | 120 mm sq |
| 209 | 185 mm sq |
| 210 | 240 mm sq |
| 211 | 300 mm sq |
| 212 | 400 mm sq |
| 213 | 630 mm sq |
| 214 | 4-Core (Aluminium) XLPE Armoured Cable |
| 215 | 10 mm sq 4-Core Cable |
| 216 | 16 mm sq 4-Core Cable |
| 217 | 25 mm sq 4-Core Cable |
| 218 | 35 mm sq 4-Core Cable |
| 219 | 50 mm sq 4-Core Cable |
| 220 | 4-Core (Aluminium) XLPE unarmoured Cable |
| 221 | 10 mm sq 4-Core Cable |
| 222 | 16 mm sq 4-Core Cable |
| 223 | 25 mm sq 4-Core Cable |
| 224 | 35 mm sq 4-Core Cable |
| 225 | 50 mm sq 4-Core Cable |
| 226 | AB (LT) Cable |
| 227 | 35 mm sq (3 x 35 + 1 x 25 mm² + 1 x 16 mm²) |
| 228 | 50 mm sq (3 x 50 + 1 x 35 mm² + 1 x 16 mm²) |
| 229 | 70 mm sq (3 x 70 + 1 x 35 mm² + 1 x 16 mm²) |
| 230 | 120 mm sq (3 x 120 + 1 x 70 mm² + 1 x 16 mm²) |
| 231 | Multi Strand Copper Wire Flame Retardant Low Smoke & Halogen FR-LSH PVC Insulated |
| 232 | 1 mm sq |
| 233 | 1.5 mm sq |
| 234 | 2.5 mm sq |
| 235 | 4 mm sq |
| 236 | 6 mm sq |
| 237 | 3-Ø, 4-Wire Tri-Vector Meter / (Prodigy meter) |
| 238 | HT Cables of HT Part |
| 239 | 1-Core, 11 KV Grade (XLPE Insulated Armoured Aluminium Cable) |
| 240 | 35 mm sq |
| 241 | 50 mm sq |
| 242 | 70 mm sq |
| 243 | 95 mm sq |
| 244 | 120 mm sq |
| 245 | 185 mm sq |
| 246 | 240 mm sq |
| 247 | 300 mm sq |
| 248 | 400 mm sq |
| 249 | 630 mm sq |
| 250 | 3-Core, 11 KV Grade (XLPE Insulated Armoured Aluminium Cable) |
| 251 | 35 mm sq |
| 252 | 50 mm sq |
| 253 | 70 mm sq |
| 254 | 95 mm sq |
| 255 | 120 mm sq |
| 256 | 150 mm sq |
| 257 | 185 mm sq |
| 258 | 240 mm sq |
| 259 | 300 mm sq |
| 260 | 400 mm sq |
| 261 | 11 KV Grade Aeriel Bunched Cable |
| 262 | 35 mm² AB (HT) Cable (3x35+1x70 mm²) XLPE (11 kV, 3C + Earth) |
| 263 | 50 mm² AB (HT) Cable (3x50+1x70 mm²) XLPE (11 kV, 3C + Earth) |
| 264 | 70 mm² AB (HT) Cable (3x70+1x95 mm²) XLPE (11 kV, 3C + Earth) |
| 265 | 120 mm² AB (HT) Cable (3x120+1x95 mm²) XLPE (11 kV, 3C + Earth) |
| 266 | 11 KV Heat Shrinkable (3-Core) Cable Termination Kit - (XLPE TYPE) - (OUTDOOR TYPE) |
| 267 | 50 mm sq 3-Core |
| 268 | 70 mm sq 3-Core |
| 269 | 95 mm sq 3-Core |
| 270 | 120 mm sq 3-Core |
| 271 | 185 mm sq 3-Core |
| 272 | 240 mm sq 3-Core |
| 273 | 300 mm sq 3-Core |
| 274 | 400 mm sq 3-Core |
| 275 | 11 KV Heat Shrinkable (1-Core) Cable Termination Kit - (XLPE TYPE) - (OUTDOOR TYPE) |
| 276 | 50 mm sq 1-Core |
| 277 | 70 mm sq 1-Core |
| 278 | 95 mm sq 1-Core |
| 279 | 120 mm sq 1-Core |
| 280 | 185 mm sq 1-Core |
| 281 | 240 mm sq 1-Core |
| 282 | 300 mm sq 1-Core |
| 283 | 400 mm sq 1-Core |
| 284 | 11 KV Heat Shrinkable (3-Core) Cable Termination Kit - for Aeriel Bunched Cable- (OUTDOOR TYPE) for |
| 285 | 35 mm² AB (HT) Cable (3x35+1x70 mm²) XLPE (11 kV, 3C + Earth) |
| 286 | 50 mm² AB (HT) Cable (3x50+1x70 mm²) XLPE (11 kV, 3C + Earth) |
| 287 | 70 mm² AB (HT) Cable (3x70+1x95 mm²) XLPE (11 kV, 3C + Earth) |
| 288 | 120 mm² AB (HT) Cable (3x120+1x95 mm²) XLPE (11 kV, 3C + Earth) |
| 289 | 11 KV 3-Core AB Cable Jointing Kit |
| 290 | 35 mm sq |
| 291 | 50 mm sq |
| 292 | 120 mm sq |
| 293 | 11 KV 3-Core XLPE Cable Straight through Jointing Kit |
| 294 | 35 mm sq |
| 295 | 50 mm sq |
| 296 | 120 -185 mm sq |
| 297 | 240-300 mm sq |
| 298 | 400-500 mm sq |
| 299 | 11 KV 1-Core XLPE Cable Straight through Jointing Kit |
| 300 | 35 mm sq |
| 301 | 50 mm sq |
| 302 | 70-120 mm sq |
| 303 | 150-185 mm sq |
| 304 | 240-300 mm sq |
| 305 | 400-500 mm sq |
| 306 | Materials without Labour (T&P) |
| 307 | Rubber Gloves suitable for 11 KV |
| 308 | Safety Belt |
| 309 | Safety Helmet |
| 310 | Safety Shoes (Ankle Boot) |
| 311 | Fire Extinguisher ABC Powder Type 4.5 Kg |
| 312 | Refilling of Fire Extinguisher - ABC Powder Type |
| 313 | Woodden Budloo Ladder, Watt Free, 18' long |
| 314 | 16.5 ft Long Portable and compact telescopic foldable aluminium ladder with 1.5 mm thickness & anodized silver finish (Max Weight 15 kg antislip rubber feet , safety lock, transportation lock with 2 year warranty |
| 315 | 18 ft long Portable and compact telescopic foldable aluminium ladder with 1.5 mm thickness & anodized silver finish (Max Weight 15 kg antislip rubber feet , safety lock, transportation lock with 2 year warranty |
| 316 | 65Ah 12V SMF Sealed Maintenance-Free Battery . |
| 317 | 12V 23 AE alkaline battery |
| 318 | 12V 100Ah Tall Tubular Inverter Battery with minimum Warranty of 60 Months with 36 Months (Flat) + 24 Months (Pro-rata) |
| 319 | 12V 200Ah Tall Tubular Inverter Battery with minimum Warranty of 60 Months with 36 Months (Flat) + 24 Months (Pro-rata) |
| 320 | Link Rod 12' long fabricated from bamboo stick duly fitted with galvanized iron Tee at the top suitable for 11 KV lines |
| 321 | PP (Polypropylene) Rope Of Sizes 2'' |
| 322 | Hydraullic Oil Grade-68 Anti-Wear for Departmental Crane |
| 323 | Manila Rope (3/4 inch) |
| 324 | Manila Rope (1.25 inch)/1.5 inch |
| 325 | Supply of Astronomical Digital Time Switch Supply Voltage : 110-240 VACSupply variation -20% to +10 %OFF Hours Programmable, based on Latitude/Longitude precise to the minute with time zoneDisplay :- LCD; IP 20 for terminals and IP40 for enclosuresEnclosure :- Polycorbonate Flame retardant (Mounting on Base/Rail)6 years Battery reserveEasy Manual Override & Keypad Lock feature |
| 326 | Supply of 160 A, 4 Pole,Power Contactor 220 V AC, 2 NO + 2 NC, AC1 Duty Network type : AC: Network frequency 50 Hz |
| 327 | Supply of 110/100 A, 4 Pole,Power Contactor 220 V AC, 415 V AC, AC1 Duty Network type : AC: Network frequency 50 Hz |
| 328 | Supply of 65/60 A, 4 Pole,Power Contactor 220 V AC1, 415 V AC, AC1 Duty Network type AC : Network frequency 50 Hz |
| 329 | Supply of 32 A Power Contactor 4 Pole, 415 V AC, AC1 Duty Network type AC ; Network frequency 50 Hz |
| 330 | Supply of all weather paint (for exterior walls) |
| 331 | Supply of wall cement Primer (for exterior walls) |
| 332 | Supply of wall cement Primer (for interior walls) |
| 333 | Supply of Colour emulsion for interior walls |
| 334 | Supply of Colour Shade (bottle) 100ml |
| 335 | Supply of Window paint (white) |
| 336 | Paint Brush 3 inch |
| 337 | Paint Brush 4 inch |
| 338 | Supply of wall Putty |
| 339 | Supply of Sand |
| 340 | Supply of Bajri |
| 341 | Supply of Bricks |
| 342 | Supply of Tile Chemical (Tile cement for tile work) |
| 343 | Supply of Tile grouting cement (Tile gap sealer |
| 344 | Suppy of Patti |
| 345 | Supply of Sand Paper (220 No) |
| 346 | Supply of Cement |
| 347 | Poly carbonate meter / Box Seal with Double Locking with 7\\" Cable Length with Technical Numbering and \\"ED-IV\\" engraved/embossed With Laser Marking (The seal should be supplied after providing\\" ED-IV\\" along with 7 (seven) sequentially numbered Alpha Numeric Digits) |
| 348 | Vitrified Anti skid floor tiles (matte finish) |
| 349 | Supply of distilled water |
| 350 | Supply of 25 mm Sandals pvc type |
| 351 | Supply of 25 mm Sandals iron type |
| 352 | Water Tank (1000 ltrs) ISI 1270 marked |
| 353 | Float valve for water tank |
| 354 | bibcock water tap |
| 355 | Angle valve |
| 356 | Mixer (Wash basin) |
| 357 | Bathtowel Big 450 GSM 70x140cm / 75x150 |
| 358 | Hand towel Hanging type |
| 359 | Bathroom cleaner |
| 360 | Bathroom scraber brush (handle type) |
| 361 | Harpic |
| 362 | Floor Cleaner |
| 363 | Collin/Glass cleaner 1/2 Ltr |
| 364 | Hand wash/ soap refill (750ml) liquid |
| 365 | Air freshner spray 100ml Spray Type |
| 366 | Air freshner 30gm (packet type) |
| 367 | Floor cleaning mop (mircofibre dry and wet cotton type) |
| 368 | Keyboard (wired) (protronics/zebranoics/HP/Dell) Plug and play USB type |
| 369 | Mouse(Wired) Plug and play USB Type (protronics/zebranoics/HP/Dell) |
| 370 | Premium Cloth Curtains for windows (polyester type) Ring Type |
| 371 | Premium Cloth Curtains for Doors (polyester type) Ring Type |
| 372 | Steel Rods for curtains 25mm dia silver crome 12ft length |
| 373 | Curtain rods end finials steel |
| 374 | Brakets for curtains rods |
| 375 | Extension cord (16A -3 Pin sockets (heavy duty) with switch -3Nos with indicator and 3 pin Top and cord length 5mtr 4mm wire size |
| 376 | Flex Banner Printing Colour (including cost of Flex material) |
| 377 | Supply of remote bell multiple tone type |
| 378 | Supply of petrolleum jelly |
| 379 | Supply of 0.5 Watt (Zero) coloured Bulbs |
| 380 | Supply of Cable ties of sizes |
| 381 | Supply of 100 Watt LED Outdoor LED Flood Light | Wide Angle Beam flush mount outdoor type IP65 Water proof philips/Crompton & greeves/ Bajaj/Havells |
| 382 | Corrugated HDPE pipe (75 mm outer dia) |
| 383 | HPDE Pipe (50 mm Inner Dia 63 mm Outer Dia ( Non Corrugated) |
| 384 | Supply of 9 Watt LED Lamp |
| 385 | Supply of 4ft long LED tube light 36/40W |
| 386 | Supply and Installation/fixing items from item SLNo. 385 to 458 |
| 387 | Replacement/supply and fixing of following accessories |
| 388 | a) LED Lamp 9 watt with minimum lumens 900 |
| 389 | b) LED Lamp 12 watt with minimum lumens 1200 |
| 390 | Replacement/supply and fixing of following luminaries as specified below. |
| 391 | Surface type LED luminaries 12-16 Watt circular/square type slim decorative aluminium casted and separate electronic driver with system temperature 5500/6000/6500 K and robust construction in combination with flat diffuser with minium system Lumens 1000 with burning hours greater than 40000 Hourshaving system lumens =90 lm/watt |
| 392 | Surface type LED luminaries 15-20 Watt circular/square type slim decorative aluminium casted and separate electronic driver with system temperature 5500/6000/6500 K and robust construction in combination with flat diffuser with minium system Lumens 1200 with burning hours greater than 40000 Hours having system lumens =90 lm/watt |
| 393 | Hanging light (fancy type light) with 9-12 Watts LED Lamp |
| 394 | 10-12 Watt LED Bulkhead luminaire with burning hours >= 50000 Hours. |
| 395 | Recessed type LED luminaries 12-16 Watt circular/square type slim decorative aluminium casted and separate electronic driver with system temperature 5500/6000/6500 K and robust construction in combination with flat diffuser with minium system Lumens 1000 with burning hours >= 50000 Hours having system lumens =90 lm/watt |
| 396 | Recessed type LED luminaries 15-20 Watt circular/square type slim decorative aluminium casted and separate electronic driver with system temperature 6000/6500 K and robust construction in combination with flat diffuser with minium system Lumens 1200 with burning hours >= 50000 Hours having system lumens =90 lm/watt |
| 397 | Providing and Fixing of 4x1 LED light panel with max 36-40 wattage, lumens/watt 100 |
| 398 | Providing fixing well glass lights 30 Watt 6000/6500k having high pressure diecast aluminum housing with poly carbonate antiglare diffuser including connection complete as required at site. (Surface Type) |
| 399 | Providing & Fixing 20W Spot Light Al. Housing Lu/W >= 100 Surface type |
| 400 | Supply of led fixture 18-30W, LED Surface / Recess Mounted Downlighter with Round Shape having Die Cast Heat housing with HET Plastic Diffuser and minimum system lumen efficacy of 100 lm/W with P.F.>0.95 and THD<10% ,CRI 80.The LED with Useful life of 50000 Hrs at L70 ,CCT of 5700 K with CRI of minimum 80.The Input voltage range shall be 150V to 270V .Fixture have Surge Protection 2kV |
| 401 | Providing and fixing of Pole Post fabricated from MS Pipe Post 10' long having 6'' dia with proper sized end plates (for supporting bed structure) including proper paint (red oxide/aluminium paint/tractor orange) and Cement Bottoming (0.25 cum) |
| 402 | Providing and Laying of Chemical Earthing using copper bonded rod electrode with complete accessories along with with proper inspection chamber having handled lid for Newly Replaced LT Distribution Panels Copper Bonded Rod Electrodes - High tensile-low carbon steel rod having diameter not less than 17mm complying with requirements of BS 4360 Grade 43A or EN10025:2-004 S275JR, molecularly bonded by 99.99% pure high conductivity copper on outer surface with copper coating thickness 250micron or more can be used selectively based on design requirement. The Copper Bonded Road Electrode must comply with UL 467(latest)BUS BAR: Mild Steel Electro galvanized bus bar of size 350mmx50mmx6mm, with minimum coating thickness of 150micron, shall be welded to earth electrode pipes or connected with the help of 2 nos. of stainless steel nut bolts of appropriate size. This bus bar connection plate shall have 3 holes of 12mm dia. placed at 50mm apart on either side (Total 6 holes) for connecting earth conductor. Three stainless steel washers &t one spring washer shall be supplied along with each stainless steel nut & bolt for necessary connection. Earth enhancement material (Back fill compound) shall be placed around earth electrode in the earth pit to improve the conductivity of earth electrode & ground contact area. (Carbon Powder or Bentonite Powder or any earth enhancement material) |
| 403 | Earthing of Sub-Station -- (Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 75 mm x10 mm & 50 mm x 6 mm) for connection of Transformer Body, G.O Set & Lightening Arrestor as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement materials and earth Chamber made of brickmasonary with RCC slab cover. |
| 404 | Earthing of ST Poles 8 mtr long using GI spike 3mm, 2mtr long |
| 405 | Earthing of ST Poles 8 mtr / 9 mtr / 11 mtr / 13 mtr long using GI Pipe 40 mm 2.5 mtr long through GI Strip. |
| 406 | Cement Bottoming of ST Poles 8 mtr long in 1:2:4 Mix upto 1/6th plantation depth of pole below ground, 9'' above ground, circular with radius 6'' around the pole girth/surface, top surface tappered outwards as per REC Standards (0.4cum/pole) |
| 407 | Cement Bottoming of ST Poles 9 mtr long in 1:2:4 Mix upto 1/6th plantation depth of pole below ground, 9'' above ground, circular with radius 6'' around the pole girth/surface, top surface tappered outwards as per REC Standards (0.48cum/pole) |
| 408 | Cement Bottoming of ST Poles 11 mtr long in 1:2:4 Mix upto 1/6th plantation depth of pole below ground, 9'' above ground, circular with radius 6'' around the pole girth/surface, top surface tappered outwards as per REC Standards 0.66cum/pole) |
| 409 | Cement Bottoming of ST Poles 13 mtr long in 1:2:4 Mix upto 1/6th plantation depth of pole below ground, 9'' above ground, circular with radius 6'' around the pole girth/surface, top surface tappered outwards as per REC Standards 0.78cum/pole) |
| 410 | Painting of New ST Poles with 1 coat of Red Oxide and 2 coats of Aluminium Paint |
| 411 | ST Pole 13 mtr. Long (ST-410 SP69) |
| 412 | ST Pole 11 mtr. Long (ST-410 SP56) |
| 413 | ST Pole 9 mtr. Long ( ST-410 SP33) |
| 414 | ST Pole 8 mtr. Long (ST-410 SP15) |
| 415 | Painting of existing ST Poles with Aluminium Paint (including Surface cleaning/removal of stickers /posters etc) |
| 416 | Supply and Fixing of 16 Amp Box Type SS Combine |
| 417 | Supply and Fixing of 16 Amp Switch |
| 418 | Supply and Fixing of 6 Amp Switch |
| 419 | Supply and Fixing of 6 Amp 5 Pin Sockets |
| 420 | Supply and Fixing of 16 Amp 5 Pin Sockets |
| 421 | Supply and Fixing of 12 Watt Surface LED lights (Poly carbonate) |
| 422 | Supply and Fixing of Gang Box 4-way(PVC) |
| 423 | Supply and Fixing of 25x12 mm PVC Channel |
| 424 | Supply and Fixing of 32x12 mm PVC Channel |
| 425 | Supply and Fixing of pvc conduit pipe 25mm |
| 426 | Supply and Fixing of pvc conduit pipe 32mm |
| 427 | Supply and Fixing of pendant Holder ( pin type ) |
| 428 | Supply and Fixing of 12 way MCB box double door |
| 429 | Supply and Fixing of Exhaust Fan 200 mm Shutter type PVC |
| 430 | Supply and Fixing of 16 Amp 3 Pin top |
| 431 | Supply and Fixing of 6 Amp 3 Pin top |
| 432 | Supply and Fixing of 6 Amp 2 Pin top |
| 433 | Supply and fixing of LED indication lamps/panel indicators (RYBG) |
| 434 | Supply and fixing of Bakelite Sheet |
| 435 | Supply and fxing of cable glands self tightening for 100/200 TPN bus bars including dismanteling and termination of cable (cable size 120/185/240 sqmm) |
| 436 | SITC of 33 kV Isolator with Earthing Blade (36kV,800A, Outdoor,3 poles, 25 kA) |
| 437 | SITC of 33 kV Lightening Arrestors (33 kV, 10kA, Station class, ZnO, Polymer) gap less (1 No. per Φ) |
| 438 | SITC of 33 kV Horn Gap Fuse set |
| 439 | SITC of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm |
| 440 | SITC of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fitting |
| 441 | SITC of 33 kV Single Tension Fittings (6 bolt) |
| 442 | SITC of 800A, 50k A 3P,MCCB, Microprocessor release, adjustable O/L, adjustable E/F along with 6 Nos. Rear Terminals (Flat or round as required), Phase barriers (4 Nos.), and the allied Padlock support:- (Lauritz Curdsen) dsine DN4-1250N Ics =100% Icu as per IEC 60947-2 |
| 443 | Supply, Installation, Testing and Commissioning of 800A,70kA, 4P, MCCBS, Microprocessor release, adjustable O/L, adjustable E/F with adjustable amperage of various Ratings, alongwith the Vary-depth Handle (consisting of the connecting rod, the bracket, the self-adhesive drilling template, the mounting accessories and door-locking mechanism), alongwith 8 Nos. Rear Terminals (Flat or round as required), Phase barriers (6 Nos.), and the allied Padlock support. (Lauritz Curdsen) DN4-1250N Ics =100% Icu as per IEC 60947-2 |
| 444 | Supply, Installation, Testing and Commissioning of 400A,70kA, 4P, MCCBs, Microprocessor release, adjustable O/L, adjustable E/F with adjustable amperage of various Ratings, alongwith the Vary-depth Handle (consisting of the connecting rod, the bracket, the self-adhesive drilling template, the mounting accessories and door-locking mechanism), alongwith 8 Nos. Rear Terminals (Flat or round as required), Phase barriers (6 Nos.), and the allied Padlock support. (Lauritz Curdsen) DN3-400S Ics =100% Icu as per IEC 60947-2 |
| 445 | Supply, Installation, Testing and Commissioning of 250A, 70kA, 4P, MCCBs, Microprocessor release, adjustable O/L, adjustable E/F with adjustable amperage of various Ratings, alongwith the Vary-depth Handle (consisting of the connecting rod, the bracket, the self-adhesive drilling template, the mounting accessories and door-locking mechanism), alongwith 8 Nos. Rear Terminals (Flat or round as required), Phase barriers (6 Nos.), and the allied Padlock support. :-(Lauritz Curdsen) DN2-250S Ics =100% Icu as per IEC 60947-2 |
| 446 | SITC of Electric Heater / Geyser of capacities as mentioned below with following parameters .1.Energy saving. 5 Star Certification by BEE 2. Provision of Temperature regulation by means of external Knob3. Power Rating:- 220/ 230V, 50 Hz, Single Phase. 4. Maximum Rated Pressure.= 8 bar 5. Installation Type Vertical / Horizontal mounted as per site requirement 6. Body Type:- Rust, water proof and Shock Proof outer body with attractive looks and corrosion resistant inner tank made of cold rolled steel ,resistant to hard water. 7. Element Type:- glass coated heating element to prevent from corrosion and hard water.8.Safety Valve maximum pressure =8 bar maximum9. Energy efficiency feature:- Should have high density PUF insulation for energy Saving10. Anti syphon system to prevent back flow of water. 11. Should have Indicating Lamps for ON & CUTT OFF.12. Conforming to :IS 2082:2018 , IS 302-1, IS 302-2-21 |
| 447 | a) 25 litre (2KW) |
| 448 | b) 35 litre (2KW) |
| 449 | c) 50 litre (2KW) |
| 450 | d) 100 litre (3KW) |
| 451 | Supply installation testing and commissioning of following sizes of metallic type exhaust fans with Bird guard to protect fan in running condition, Double ball bearing with Heavy duty motor. |
| 452 | i) 9\\" |
| 453 | ii) 12\\" |
| 454 | iii) 15\\" |
| 455 | ii) 18\\" |
| 456 | iii) 24\\" |
| 457 | Supply installation testing and commissioning of following sizes of plastic body exhaust fans shutter type with Heavy duty motor Rated speed = 1400 RPM . RAte voltage -220 to 240 Volts . |
| 458 | i) 150 mm |
| 459 | ii) 200 mm |
| 460 | ii) 225 mm |
| 461 | iii) 250 mm |
| 462 | iv) 300 mm |
| 463 | P/F of wooden frames of various sizes and making of holes for installing of exhaust fans complete with civil work in all respects for following size Exhaust Fans: |
| 464 | i) 12” |
| 465 | ii) 15” |
| 466 | iii) 18” |
| 467 | iv) 24” |
| 468 | P/f of fan hooks of various types S type, U type, J type. |
| 469 | Providing, installation, testing and commissioning of LED Street light luminaire as per following specifications:1. Input voltage : 150 V to 270 V 2. LDE lamp efficiency : Min 95 to 110 lumens/watt 3. Power factor : >0.90 4. Life expecting : 50,000 hours5. No of hours usage / day : 10 to 12 hours/day 6. Rated watt : 70-80 W 7. Luminous flux : 7000 to 8000 lumens 8. Colour Temperature : 5,500 to 6500 K with test certificate 9. Ingress protection : IP 65/IP 66 10. Total harmonic distortion (THD): <15% with test certificate 11. Colour rendering index : Ra > 75 12. Working Temperature : 0 deg to 50 deg C 13. Average lighting/ beam angle : 120 to 160 deg 14. System power efficiency : > 85 % 15. Luminary Casing : Pressure die cast Aluminum with toughened glass cover and water proof fixture |
| 470 | Providing & making RCC foundation of 1300mm(H) × 600mm × 600mm size with 1:2:4 (1Cement, 2 Coarse, 4 Stone aggregate) complete with 12mm dia. M.S. bar for reinforcement along with centering & shuttering i/c supplying & fixing 600mm long , 16mm dia J type G.I, coated foundation bolt/ Anchor bolt with template suitable for ornamental / 6.0mtr octogonal Pole.The job includes cost of 100mm dia 600mm length corgated pipe complete with excavation the soil & refilling, ramming, curing etc. as reqd. For 06 meter Octogonal Galvanized Pole |
| 471 | Providing, installation, testing and commissioning of LED Street light luminaire as per following specifications:1. Input voltage : 150 V to 270 V 2. System efficiency : Min 100 to 110 lumens/watt 3. Power factor : >0.90 4. Life expecting : 50,000 hours5. No of hours usage / day : 10 to 12 hours/day 6. Rated watt : 40-50 W 7. Luminous flux : 4000 to 5000 lumens 8. Colour Temperature : 5,500 to 6500 K with test certificate 9. Ingress protection : IP 65/IP 66 10. Total harmonic distortion (THD): <15% with test certificate 11. Colour rendering index : Ra > 75 12. Working Temperature : 0 deg to 50 deg C 13. Average lighting/ beam angle : 120 to 160 deg 14. System power efficiency : > 85 % 15. Luminary Casing : Pressure die cast Aluminum with toughened glass cover and water proof fixture |
| 472 | Supply, installation, testing and commisioning of LED flood light luminaries in place of existing non functional High mast Lights as per following specification 1. Input voltage : 150 V to 270 V2.Lumens : Min 105003. Power factor : >0.904. Life expecting : more than 40,000 hours5. No of hours usage / day : 10 to 12 hours/day6. Rated watt : 110-120W7. Luminous flux : 10500 to 12000 lumens8. Colour Temperature : 5,500 to 6,500 K with test certificate9. Ingress protection : IP 65/IP 66 as per IS/IEC60529-2001 with test certificate10. Total harmonic distortion (THD): <15% with test certificate11. Colour rendering index : Ra > 8012. Working Temperature : 0 deg to 50 deg13. Luminary Casing : Pressure die cast Aluminum with toughened glass cover and water proof fixture |
| 473 | SITC of wall mount heat convectors/ blower 230volt 50HZ Single phase 2000 watt with adjustable 3 heat setting, ,Auto thermal Cut ,Twin fan blade: 50degree, well balanced Copper conductors ,with a swing stand PVC Sheathed cord, 15A, 3 pin moulded plug |
| 474 | Suplying of wall mount heat convectors/ blower 230volt 50HZ Single phase 2000 watt with adjustable 3 heat setting, ,Auto thermal Cut ,Twin fan blade: 50degree, well balanced Copper conductors ,with a swing stand PVC Sheathed cord, 15A, 3 pin moulded plug |
| 475 | SITC of Wall mount fans 400 mm with Plastic Body as specified below: 1.Motor AC 2.Governing standard I.S.2997 (Latest) 3.Power Consumption: Approx. 100 Watts4.Power supply Single phase AC 230V, 50Hz 5.Speed: 1200 -1400 rpm with regulator 6.Sweep: 400 mm 7.Air Flow: 72-80 m3/min. 8..motor protection through thermal9.overload protection device 10.It should have minimum 3 levels of speed control. Features:Suitable for mounting on walls with easy mounting system, Noise level shall be within limits adjustable upward and downward tilt mechanism |
| 476 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, Ceiling fan, BLDC type class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019),THD less than 10% and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulationresistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 477 | Labour items /Hire charges (from item SLNo. 462 to 625 ) |
| 478 | Key Materials |
| 479 | Steel Tubular Poles Of Sizes |
| 480 | ST Pole 13 mtr. Long (ST-410 SP69) |
| 481 | ST Pole 11 mtr. Long (ST-410 SP56) |
| 482 | ST Pole 9 mtr. Long (ST-410 SP33) |
| 483 | ST Pole 8 mtr. Long (ST-410 SP15) |
| 484 | PCC Poles Of Sizes |
| 485 | PCC Pole 9 mtr. Long (WL =300 Kg) |
| 486 | PCC Pole 8 mtr. Long (WL =250 Kg) |
| 487 | ACSR Conductor of Sizes |
| 488 | 0.1 ACSR Conductor (Dog) |
| 489 | 0.05 ACSR Conductor (Rabbit) |
| 490 | 0.03 ACSR Conductor (Weasel) |
| 491 | 11 KV Gang Operating, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type comprising of 9 No. insulators, pipes and lock pad etc complete job (Polymer Type) |
| 492 | 11 KV Gapless Surge Arrestor, 9 kV, 10 kA, Lighting Arresor with polymer housing, Stn. Type |
| 493 | 11 KV Gapless Surge Arrestor, 9 kV, 10 kA, Lighting Arresor with porcelain type housing, Stn. Type |
| 494 | 11 KV Horn Gap Fuse Set 3-Phase 200 Amp (Polymer Type) |
| 495 | 11 KV Horn Gap Fuse Set 3-Phase 200 Amp (porcelain type) |
| 496 | G.I.Wire No. 8 SWG & 6 SWG |
| 497 | Guy Insulators (11 KV) |
| 498 | Pole Collars / Back Clamp of 50x8mm galvanized Flat Iron |
| 499 | GI Barbed Wire for Anticlimbing |
| 500 | Anticlimbing Devices with Clamp |
| 501 | 11 KV Danger Plate with Clamp |
| 502 | Galvanized Nuts and Bolts of sorts |
| 503 | Galvanized Channel Iron Cross Arm/angle brace of Sizes |
| 504 | Galvanized V Cross-Arms duly fabricated of size 75x40x6mm Channel Iron Cross Arm with 04 No. (50x50x6mm) welded flat iron plates as per Drg. No. CE/P&P/DRG/2022/11KVL001) |
| 505 | Pole bracket (F-Top for v cross configuration)s as per Drg. No. CE/P&P/DRG/2022/11KVL001) |
| 506 | Installation of Single pole MCB's Curve Series of breaking capacity 10 kA (6amp to 100 amp) |
| 507 | Installation of double pole MCB's Curve Series of breaking capacity 10 kA (6amp to 100 amp) |
| 508 | Installation of TP MCB C-Curve Series, of breaking capacity 10 kA) (16amp to 100 amp) |
| 509 | Installation of TP MCCB Adjustable type ( upto 100amps) |
| 510 | Installation of TP MCCB Adjustable type ( above 100amps ) |
| 511 | Installation of TPN MCCB Adjustable type ( upto 100amps) |
| 512 | Installation of TPN MCCB Adjustable type ( above 100amps ) |
| 513 | Installation of Enclosure for fixing of TP MCCB / TPN MCCB adjustible of size upto to 100amp. along with clamps and all other accessories |
| 514 | Installation of Enclosure for fixing of TP MCCB / TPN MCCB adjustible of size above 100amp. along with clamps and all other accessories |
| 515 | Installation of LT Distribution Box for 63KVA / 25 kVA DTR (details given in the supply component) |
| 516 | Installation of LT Distribution Box for 100 kVA DTR (details given in the supply component) |
| 517 | Installation of LT Distribution Box for 200KVA / 250 kVA DTR (details given in the supply component) |
| 518 | Installation of LT Distribution Box for 400KVA / 630 kVA DTR (details given in the supply component) |
| 519 | installation of Manual Change Over Switch 63 Amp TPN |
| 520 | installation of Manual Change Over Switch 100 /200 Amp TPN |
| 521 | installation of 3-phase Onload Changeover switch 100 amp. |
| 522 | installation of Aluminium Thimbles Suitable for Cable Size upto 50sqmm (Long Barrel Type) |
| 523 | installation of Aluminium Thimbles Suitable for Cable Size (70 -95 sqmm) (Long Barrel Type) |
| 524 | installation of Aluminium Thimbles Suitable for Cable Size (120 -185 sqmm) (Long Barrel Type) |
| 525 | installation of Aluminium Thimbles Suitable for Cable Size 240 sqmm (Long Barrel Type) |
| 526 | installation of Aluminium Thimbles Suitable for Cable Size 300 sqmm (Long Barrel Type) |
| 527 | installation of Aluminium Thimbles Suitable for Cable Size 400 sqmm (Long Barrel Type) |
| 528 | installation of Aluminium Thimbles Suitable for Cable Size 630 sqmm (Long Barrel Type) |
| 529 | installation of Copper Thimbles for 16sqmm-50sqmm |
| 530 | installation of 11 KV Polymeric composite Pin Insulator |
| 531 | Installation of 11 kV Polymeric composite Disc Insulator with fitting |
| 532 | Installation of Galvanised Stay Set complete |
| 533 | Installation of GI Pole Support Clamp for AB Cable suitable for ST /PCC Poles |
| 534 | Installation of Eye Hook for holding HT/LT AB cable ( as per Dwg) |
| 535 | Installation of Suspension Clamp for HT/LT AB cable |
| 536 | Installation of Dead End/Tension Clamp for HT/LT AB cable |
| 537 | Installation of 11 KV Isolator, double break, 3-pole, 630 Amp, horizontal mounting Type, with Earth Switch. |
| 538 | Fixing/laying of Guard Netting Complete including fixing of all accessories like GI Channel X-arm , clamps , braces, galvanized nuts and bolts, GI Wire 8 or 6 SWG, Eye Bolts etc (complete) |
| 539 | Installation of PG (Parallel Groove) Clamps for ACSR Conductor 0.05/0.1 ACSR |
| 540 | Installation of LT Shackle Insulators 16 KN 100 mm |
| 541 | installation of GI U/D-Clamps for LT Shackle Insulators with 01 No. MS Bolt |
| 542 | Installation of GI Muki Clamp for LT Shakckle using (50x6 ) mm galvanized flat iron suitable for ST Pole with back clamp and galvanized nuts and bolts |
| 543 | Installation of LT fuse set comprising of requisite aluminium bus bar mounted on LT polymer insulator assembled on galvanized channel iron frame including necessary clamps ( Strictly as per drawing attached) |
| 544 | Fixing of Piercing Connectors (for main/street light connection/ T-connection) |
| 545 | Fixing of 3-phase Pole mounted Distribution Box (outdoor type) |
| 546 | Fixing of 1-phase Pole mounted Distribution Box (outdoor type) |
| 547 | Aluminium Jointing Sleeves |
| 548 | LT Line Spacer - 2 Phase 3 Wire |
| 549 | LT Line Spacer - 3 Phase 4 Wire |
| 550 | Underground laying of LT cable of sizes in trench size: depth 750mm & width 300mm with excavation of earth including hard soil , Back filling with sand cushioning (75mm below cable and 75 mm above ) and warning tape as per IS 1255-1983)---complete labour job |
| 551 | Underground laying of HT cable of sizes in trench size depth 950 mm & width 300mm with excavation of earth , Back filling with sand cushioning (75mm below cable and 75 mm above ) and warning tape : as per IS 1255-1983) |
| 552 | Laying of HT/LT cable in existing conduite pipe/HDPE pipe etc for sizes |
| 553 | 50-185 sqmm |
| 554 | 240-400 sqmm |
| 555 | 630 sqmm |
| 556 | Laying of LT cable on wall surface as required at site |
| 557 | uto 35 sqmm |
| 558 | 50-185 sqmm |
| 559 | 240-400 sqmm |
| 560 | 630 sqmm |
| 561 | Laying of Unarmoured LT Cable of various sizes (95 sqmm to 630 sqmm) in Open Air (From DT to LT DB or Fuse Set and Fuse set to Zero pole) - |
| 562 | Overhead Laying of LT meter Cable 2 core/4 core of 16 sqmm/25 sqmm |
| 563 | laying of AB (LT) Cable of sizes |
| 564 | 35 mm sq (3 x 35 + 1 x 25 mm² + 1 x 16 mm²) |
| 565 | 50 mm sq (3 x 50 + 1 x 35 mm² + 1 x 16 mm²) |
| 566 | 70 mm sq (3 x 70 + 1 x 35 mm² + 1 x 16 mm²) |
| 567 | 120 mm sq (3 x 120 + 1 x 70 mm² + 1 x 16 mm²) |
| 568 | Laying/ Drawing of Multi Strand Copper Wire Flame Retardant Low Smoke & Halogen FR-LSH PVC Insulated of sizes (1 sqmm to 6 sqmm |
| 569 | Fixing of 3-Ø, 4-Wire Tri-Vector Meter / (Prodigy meter) |
| 570 | Laying of 11 KV Grade Aeriel Bunched Cable |
| 571 | 35 mm² AB (HT) Cable (3x35+1x70 mm²) XLPE (11 kV, 3C + Earth) |
| 572 | 50 mm² AB (HT) Cable (3x50+1x70 mm²) XLPE (11 kV, 3C + Earth) |
| 573 | 70 mm² AB (HT) Cable (3x70+1x95 mm²) XLPE (11 kV, 3C + Earth) |
| 574 | 120 mm² AB (HT) Cable (3x120+1x95 mm²) XLPE (11 kV, 3C + Earth) |
| 575 | Fixing/installation of 11 KV Heat Shrinkable (3-Core) Cable Termination Kit for XLPE underground cables / AB cables of all sizes |
| 576 | Fixing/installation of 11 KV Heat Shrinkable (1-Core) Cable Termination Kit - (XLPE TYPE) - (OUTDOOR TYPE) of all sizes |
| 577 | Fixing/installation of 11 KV /LT Heat Shrinkable (3-Core) cable straight through jointing Kit for XLPE underground cables / AB cables of all sizes |
| 578 | Fixing/installation of 11 KV/LT 1-Core XLPE Cable Straight through Jointing Kit |
| 579 | Dismantaling of Items etc .. Jobs as a Labour Part |
| 580 | Dismantaling of 11 KV Link Set (Post Type) |
| 581 | Dismantaling of 11 KV Gang Operating, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type comprising of 9 No. insulators, pipes and lock pad etc complete job |
| 582 | Dismantaling of Gapless Surge Arrestor, 9 kV, 10 kA, Lighting Arresor with polymer housing, Stn. Type (Rashtriya, Spark or Yamuna Make) |
| 583 | Dismantaling of 11 KV Horn Gap Fuse Set 3-Phase 200 Amp |
| 584 | Dismantaling of 11 KV Porcelain Pin Insulator with Pins |
| 585 | Dismantaling of 11 KV Tension Disc with Fittings for 0.05/0.1 ACSR Conductor |
| 586 | Dismantaling of Channel Iron Cross Arm of Sizes, Galvanized Angle Iron Brace of Sizes with clamps, nuts and bolts |
| 587 | Dismantaling of HT/LT Poles along with allied material (Bottom cutting) |
| 588 | ST Pole 13 mtr. Long (ST-410 SP56) |
| 589 | ST Pole 11 mtr. Long (ST-410 SP56) |
| 590 | ST Pole 9 mtr. Long ( ST-410 SP33) |
| 591 | ST Pole 8 mtr. Long (ST-410 SP15) |
| 592 | 8 /9 mtr. long PCC Poles with proper disposal |
| 593 | Wooden Poles |
| 594 | Straightening of Tilted HT/LT Poles with suitable concreting |
| 595 | ST Pole 11 mtr. Long (ST-410 SP56) |
| 596 | ST Pole 9 mtr. Long ( ST-410 SP33) |
| 597 | ST Pole 8 mtr. Long (ST-410 SP15) |
| 598 | Dismantaling of ACSR Conductor |
| 599 | 0.1 ACSR |
| 600 | 0.03 / 0.05 ACSR |
| 601 | Stringing of Loose/Sagged ACSR Conductor |
| 602 | 0.1 ACSR |
| 603 | 0.03 / 0.05 ACSR |
| 604 | Dismantling of HT/LT Aeriel Bunched Cable of sizes |
| 605 | Relaying of dismantled HT/LT Aeriel Bunched Cable of sizes |
| 606 | Laying of HT/ LT Cable through HDD Drilling method including cost of HDPE pipe |
| 607 | Branch Cutting of Extensive Trees along the Feeder Corridor engaging Skilled-Labour (s) for a day with proper protection equipments like Safety belt and Helmets |
| 608 | Commissioining of 11/0.433 KV, 3 Phase Distribution Transformer available on Sub-Station Bed Structure by way of proper HT AND LT connectioning |
| 609 | Dismantling of 11/0.433 KV, 3 Phase Distribution Transformer available on Sub-Station Bed Structure by way of opening of HT AND LT connectioning |
| 610 | Loading of LT/HT Poles and ACSR Conductor from Divisional Stores at khanyar to Working Site and Unloading of same including Site Carriage in bylanes/narrow lanes Within jurisdiction of KPDCL, ED-IV, Khanyar. |
| 611 | ST Pole 11 mtr. Long (ST-410 SP56) |
| 612 | ST Pole 9 mtr. Long (ST-410 SP33) |
| 613 | ST Pole 8 mtr. Long (ST-410 SP15) |
| 614 | 8 /9 mtr. long PCC Poles |
| 615 | UnLoading of LT/HT Poles and ACSR Conductor from Divisional Stores at khanyar to Working Site and Unloading of same including Site Carriage in bylanes/narrow lanes Within jurisdiction of KPDCL, ED-IV, Khanyar. |
| 616 | ST Pole 11 mtr. Long (ST-410 SP56) |
| 617 | ST Pole 9 mtr. Long (ST-410 SP33) |
| 618 | ST Pole 8 mtr. Long (ST-410 SP15) |
| 619 | 8 /9 mtr. long PCC Poles |
| 620 | Hire Charges including fuel and driver of Crane for lifting of transformers at site and subsequent loading of fresh/reclaimed/damaged Transformer |
| 621 | Trip upto 5 kms (to end fro) |
| 622 | Trip above 5 kms to 10 kms(to end fro) |
| 623 | Trip above 10 kms (to end fro) |
| 624 | Hire Charges including fuel and driver of Pickup/TATA Mobile/Load carrier for lifting of transformers at site and subsequent loading of fresh/reclaimed/damaged Transformer |
| 625 | Trip upto 5 kms (to end fro) |
| 626 | Trip above 5 kms to 10 kms(to end fro) |
| 627 | Trip above 10 kms (to end fro) |
| 628 | Engaing of hydra Crane including fuel and driver for lifting of damaged transformers for full working day (Fuel to be provided by the department) |
| 629 | Transportation charges including fuel and driver for Carriage of LT/HT Poles and ACSR Conductor from Khanyar Stores to Working Site Within ED-IVth or vice versa |
| 630 | Trip upto 5 kms |
| 631 | Trip above 5 kms to 10 kms |
| 632 | Trip above 10 kms |
| 633 | Hire charges for plastic /Wooden Tables(with table cloth) for functions/events per day |
| 634 | Hire charges for Strong Plastic Chairs for functions/events per day |
| 635 | Hire charges for VIP /Executive Chairs for functions/events per day |
| 636 | Hire charges for Water proof Tent 20x36ft |
| 637 | Rental Charges for providing of small DG sets of 2800/3000 VA (portable) without cost of fuel (at site) |
| 638 | Rental Charges for providing of DG sets of higher capacity (portable) without cost of fuel (including labour/loading/carriage and unloading of equipment at site) |
| 639 | 50 KVA |
| 640 | 63 KVA |
| 641 | 100 KVA |
| 642 | Segregation of 11 KV AB Cable into individual phases and subsequent re laying on GI Cross Arm ( pin insulators) |
| 643 | Supply of Skilled worker ( Carpenter/Plumber/Mason/Painter) |
| 644 | Supply of Unskilled labour |
| 645 | DG SETS from item SLNo. 626 onwards |
| 646 | Cleaning of exhaust pipes silencers with using of chemicals and cleaning of exhaust smoke from inner sides of pipes for avoiding of over heating of DG sets. The job includes dismantling of fluntch nuts and bolts including replacement of gaskets etc of 400kva |
| 647 | Repairing, cleaning of of below mentioned DG set radiators by way of using chemical and radiwash AX1013358 for DG Sets etc. The job includes repairing of damaged tubes by way of using soldering etc including replacement of upper and lower gaskets at site, also refixing the same on existing foundation of below mention DG sets. |
| 648 | Repairing of Cylinder heads of 400 KVA D.G Set (kirloskar Make) by way of dismantalling and refixing at site after repairing at workshop .The job includes valve griding incuding its transportation and loading and unloading. |
| 649 | Replacement of following items of Cylinder heads |
| 650 | 400 KVA DG set |
| 651 | a) Valve intake and Exhaust |
| 652 | b) Guide valve |
| 653 | c) Head Gasket Set (Complete set ) |
| 654 | 400 KVA |
| 655 | a) Valve intake and Exhaust |
| 656 | b) Guide valve |
| 657 | c) Head Gasket Set (Complete set ) |
| 658 | Opening & Repairing of DC 24 Volt Dynamo by way of replacement of below mentioned parts by new one in place of existing out of order parts at work shop. The job includes cost of refixing. |
| 659 | Repairing of armature |
| 660 | Carbon brushes set |
| 661 | Belt Dynamo |
| 662 | Brush holder |
| 663 | Bearings |
| 664 | Opening & Repairing of Self starters of 400 KVA DG sets (kirloskar make) by way of complete dismantling checking repairing refixing including transportation up to work shop for checking of damaged parts. The job includes replacement of below mention parts by new one as under. |
| 665 | Supply handling transportation loading and un loading of below mentioned items for various capacities for smooth running of DG . |
| 666 | c) M.oil premium |
| 667 | d) K.oil super |
| 668 | e) Distilled water |
| 669 | f) Sulphuric acid |
| 670 | Replacement of in let hose pipe with clamp |
| 671 | Replacement of Out let turbo charger hose with clamp |
| 672 | Replacement of M oil in let pipe |
| 673 | Replacement of M oil out let pipe |
| 674 | Supply and fixing of Rubber packing of 1pieces for coupler of DG set Alternator and Engine as per site requirement |
| 675 | Supply and fixing of Bolts for coupler |
| 676 | Dismantling, opening and repair of self starters from 400 KVA DG sets for checking of damaged parts etc. This job includes its transportation loading un loading including refixing at site. (KIRLOSKAR make DG sets) |
| 677 | Supply of HSD with BIS standards (IS 1460:2017), density between 820–860 kg/m³. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |