| 1 | Single Energy Linear Accelerator (LINAC) (6MV) with Ring based Gantry integrated with Computed Tomography (CT) Scan using helical fan beam technology (Type-I) as per specification |
| 2 | Single Energy Linear Accelerator (LINAC) (6MV) with Ring based Gantry integrated with Computed Tomography (CT)/Cone Beam Computed Tomography (CBCT) Scan using cone beam technology (Type-II) as per specification |
| 3 | Single Energy Linear Accelerator (LINAC) (6MV) with C-Arm based Gantry integrated with Computed Tomography (CT)/Cone Beam Computed Tomography (CBCT) Scan (Type-III) as per specification |
| 4 | Accessories (Immobilization Devices & System) as per specification |
| 5 | Accessories (Quality Assurance System and Tools) as per specification |
| 6 | Accessories (Dosimetry Equipment- Radiation Safety Equipment) as per specification |
| 7 | Single Energy Linear Accelerator (LINAC) (6MV) with Ring based Gantry integrated with Computed Tomography (CT) Scan using helical fan beam technology as per specification (Type-I) Single Energy Linear Accelerator (LINAC) (6MV) with Ring based Gantry integrated with Computed Tomography (CT) Scan using helical fan beam technology as per specification Turnkey works as per specification (for 1 set) Break up price for 1b Lump sum cost as per specification Under ‘A’ Break up price under ‘i' of 1b 1. All internal wiring including that of telephone, LAN, DICOM & PACS etc., Necessary concealment with wire mesh/sheet metal/non-ferrous materials at the cable entry / exit points, various openings in the equipment and electrical panels etc., to make the system rodent/ pest proof 2.Ductable Air conditioning of minimum 8 ton for treatment room to maintain temperature not exceeding 20⁰C. 3.Split AC of 2 ton capacity – atleast 2 nos. for TPS room, depending on size; Split AC of 2 ton capacity – 4 nos. AC to be provided for control console room 4. Fire Safety System 5. Audio call bell system with intercom and remote locking/ unlocking facility 6. Closed Circuit cameras (4 nos. per site) 7. Furniture items as per specification False Ceiling Vinyl flooring Wall tiles Aluminium partition Lead lining Electrical Services Sub total (1b: turnkey works) Sub total (Sch.no.1) |
| 8 | Single Energy Linear Accelerator (LINAC) (6MV) with Ring based Gantry integrated with Computed Tomography (CT)/Cone Beam Computed Tomography (CBCT) Scan using cone beam technology (TYPE-II) Single Energy Linear Accelerator (LINAC) (6MV) with Ring based Gantry integrated with Computed Tomography (CT) Scan using helical fan beam technology as per specification Turnkey works as per specification (for 1 set) Break up price for 2b Lump sum cost as per specification Under ‘A’ Break up price under ‘i' of 2b 1. All internal wiring including that of telephone, LAN, DICOM & PACS etc., Necessary concealment with wire mesh/sheet metal/non-ferrous materials at the cable entry / exit points, various openings in the equipment and electrical panels etc., to make the system rodent/ pest proof 2.Ductable Air conditioning of minimum 8 ton for treatment room to maintain temperature not exceeding 20⁰C. 3.Split AC of 2 ton capacity – atleast 2 nos. for TPS room, depending on size; Split AC of 2 ton capacity – 4 nos. AC to be provided for control console room 4. Fire Safety System 5. Audio call bell system with intercom and remote locking/ unlocking facility 6. Closed Circuit cameras (4 nos. per site) 7. Furniture items as per specification False Ceiling Vinyl flooring Wall tiles Aluminium partition Lead lining Electrical Services Sub total (2b: turnkey works) Sub total (Sch.no.2) |
| 9 | Single Energy Linear Accelerator (LINAC) (6MV) with C-Arm based Gantry integrated with Computed Tomography (CT)/Cone Beam Computed Tomography (CBCT) Scan (TYPE-III) Single Energy Linear Accelerator (LINAC) (6MV) with Ring based Gantry integrated with Computed Tomography (CT) Scan using helical fan beam technology as per specification Turnkey works as per specification (for 1 set) Break up price for 3b Lump sum cost as per specification Under ‘A’ Break up price under ‘i' of 3b 1. All internal wiring including that of telephone, LAN, DICOM & PACS etc., Necessary concealment with wire mesh/sheet metal/non-ferrous materials at the cable entry / exit points, various openings in the equipment and electrical panels etc., to make the system rodent/ pest proof 2.Ductable Air conditioning of minimum 8 ton for treatment room to maintain temperature not exceeding 20⁰C. 3.Split AC of 2 ton capacity – atleast 2 nos. for TPS room, depending on size; Split AC of 2 ton capacity – 4 nos. AC to be provided for control console room 4. Fire Safety System 5. Audio call bell system with intercom and remote locking/ unlocking facility 6. Closed Circuit cameras (4 nos. per site) 7. Furniture items as per specification False Ceiling Vinyl flooring Wall tiles Aluminium partition Lead lining Electrical Services Sub total (3b: turnkey works) Sub total (Sch.no.3) |
| 10 | Accessories (Immobilization Devices & System) pertaining to Single Energy Linear Accelerator (LINAC) (6MV) with integrated with Computed Tomography (CT) Patient Immobilization system as per specification Immobilization devices Break up for 4)b) for 1 set 1. One for All, Immobilization devices having a total solution to treat Paediatric to Adult in supine and prone and capable of treating Head, Head & Neck, Breast, Thorax. Abdomen, Pelvic and Extremities and with suitable attachments to be supplied to the same Universal Treatment Base Plate, frameless SRT / SRS and frameless SBRT (support frame to be provided for frameless application) 2. One No. of Universal treatment base plate (All in One) made of true Carbon Fibre shall be provided for CT room 3. One No. identical to that of Universal treatment base plate Carbon Fibre, but made of Glass Fiber or MR compatible (Not Acrylic) for mould room / MRI room shall be provided 4. All-in-one Base Plate shall be of a Long Board Minimum Length 160 cm and thickness 2 cm 5. Carbon-fibre wedges set (to be used with head support) 2 angles: 5 and 10 degrees 6. Carbon-fibre head rest / head support set (1 set contain minimum 3 sizes) 7. Carbon-fibre wedges set (to be used with head support) 2 angles: 5 and 10 degrees 8. Carbon-fibre Wing board / Eagle board with T and U grips (to be used along with the Universal base plate offered) 9. Carbon-fibre Pelvic board for prone treatments 9) Double mask system for frameless radiosurgery (MR Safe) Immobilization system Break up for 4)c) for 1 set 1) Whole body SBRT body lock system with rails 2) Nasal cushions 3) Bite system 4)Head support 5) Thermoplastic masks for exclusive use with this system 6) Compatible Head rest 7) Wing board with U grip handle 8) Spacers & wedges – set of 4 9) Carbon-fibre belly board 10) Patient positioning system and premier thermoplastic masks 11) Head & Neck & shoulder base plates 12) Head & Neck with larynx extension 13) Water bath with digital programmable Temperature control Sub total (Sch.no.4) |
| 11 | Accessories (Quality Assurance System and Tools) pertaining to Single Energy Linear Accelerator (LINAC) (6MV) with integrated with Computed Tomography (CT) |
| 12 | Quality Assurance System and Tools as per specification |
| 13 | 3D IMRT Fluence Verification System (2D array detectors) with software as per specification Sub total (Sch.no.5) |
| 14 | Accessories (Dosimetry Equipment- Radiation Safety Equipment) pertaining to Single Energy Linear Accelerator (LINAC) (6MV) with integrated with Computed Tomography (CT) |
| 15 | Ion Chamber based calibrated survey meter with valid calibration certificates as per specification |
| 16 | GM-based calibrated survey meter with valid calibration certificate as per specification |
| 17 | Digital Pocket dosimeter as per specification |
| 18 | Last Man Out Switch as per specification Sub total (Sch.no.6) Please Enable Macros to View BoQ information |