| 1 | Earth work in excavation by mechanical means (Hydraulicexcavator) over areas (exceeding 30cm in depth,1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and liftupto 1.5m,asdirected by Engineer-in-charge All kinds of soil @75% |
| 2 | Ordinary rock@ 15% |
| 3 | Hard rock (Blasting Prohibited)@10% |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator) in foundation trenches or drains (not exceeding 1.5m in width or10sqm on plan), including dressing of sides and ramming of bottoms, lift upto1.5m, including getting out the excavated soi land disposal of surplus excavated soil as directed,within a lead of 50 m.All kinds of soil @75% |
| 5 | Ordinary rock@ 15% |
| 6 | Hard rock (Blasting Prohibited)@10% |
| 7 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc.complete. |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 9 | Random rubble masonry withhard stone in foundation andplinth including levelling upwith cement concrete1:6:12(1cement :6coarsesand:12graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand |
| 10 | Random rubble masonry with hard stone in super structure above plinth level and upto floor five level, including leveling upwith cement concrete 1:6:12(1cement :6 coarse sand: 12 graded stone aggregate 20 mm nominal size) at window sills,ceiling level and the like.Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 11 | Random rubble masonry with hard stone laid dry in foundation, plinth & walls Laid without bond stone |
| 12 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement- All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 13 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 14 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 15 | Providing and fixing upto five floor level pre cast cement concrete solid block including hosting and setting in position in cement mortar 1:3 cement sand cost of required centring shuttring,and curring complete (1:3:6).crushed stone of 20mm dia. |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform. |
| 20 | Steel reinforcement for R.C.C. work ready touse \\"cut andbend\\" rebars of approved make from factory/ works upto construction site including placing in position and binding all complete above plinth level. |
| 21 | 15mm cement plaster 1:3(1cement:3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall. |
| 22 | 6 mmcement plaster 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams. |
| 23 | Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete vide 16,17. |
| 24 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately):Second class Teak wood. |
| 25 | Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows fixing with butt hingesof required size with necessary screws,excluding panelling which will be paid for separately,all complete as per direction of Engineer-in-charge.(Note:-But thinges and necessary screws shall be paid separately) Second class teak wood 35 mm thick shutters |
| 26 | 12mm thick pre laminated particle board (decorative lamination on both sides) grade 1,medium density flat pressed, three layer particle board FPT-Iorgraded wood particle board FPT- I, conforming to IS : 3087, bondedwithBWP type synthetic resinadhesiveasper IS : 848andpre-laminatedconforming to IS :12823, Grade 1, Type - II marked |
| 27 | Float glass panes 4 mm thick glass pane (weight not less than 10kg/sqm). |
| 28 | Applying priming coat:With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood). |
| 29 | Providing and applying two coats of fire retardant paint on cleaned wood/ply surface @3.5 sqm per litre per coat including preparation of base surface as per recommendations of manufacturer to make the surface fire retardant. |
| 30 | Providing and fixing PTMT Tower Bolts with 12 mm one piece rod inside and necessary screws etc., complete.152x42x18 mm weighing not less than 60 gms |
| 31 | Providing and fixing bright finished brass door latch with necessary screws etc. complete : :250x16x5 mm |
| 32 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc.complete :100 mm |
| 33 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :150x10 mm |
| 34 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished withmnecessary screws etc. complete :75x47x1.70 mm |
| 35 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 36 | Quasi-dressed dressed stone masonary with white stone up to five floor level including levelling with cement sand mortar of 1:6 dressing of the stone to be done on both side including carrige up to a lead of 30km By MT |
| 37 | Disposal of excavated earth upto to a lead of 2 km by MT. |
| 38 | Carriage of Cement /Steel upto a lead of 50km |
| 39 | carriage of sand /Bajree up to lead of 20 km by MT |
| 40 | Carriage of stone upto a lead of 25km By MT . |
| 41 | Providing and fixing of white vitreous W.C with C.P bolts C.I Chair or other things hanging arrangment with volume flushing cistern and internal fitting. Indian W.C |
| 42 | English WC |
| 43 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) WhiteVitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole |
| 44 | Providing and fixing white vitreous china pedestal for washbas in completely recessed at the back for the reception of pipes and fittings. |
| 45 | Providing and fixing of PVC prience pipe type-B of different size incld. Fitting as per requiremant complete.100mm dia |
| 46 | 75mm dia |
| 47 | P/F of 4\\" PVC (P- trape, floor trape, door junction , plain bend and tee) and 3\\" plain bend complete job. |
| 48 | Providing and fixing PPR Pipe with all fittings and fixture complete.32mm dia |
| 49 | 20mm dia |
| 50 | Providing and fixing of C.P fitting of Jaugar, Haindware, Parko,ceara, brand including all fixiture complete job.Angle Cock. |
| 51 | Bib Cock/Pillar cock |
| 52 | Wall mixer 3 in one |
| 53 | Basin mixer single lever |
| 54 | Coupling |
| 55 | CP nipple different size |
| 56 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approvedquality and colour:450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms |
| 57 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 58 | Providing and fixing Ist quality ceramic glazed wall tiles conforming (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 59 | P/F of PVC waste pipe for sink or washbasin including pvc waste fitting flexible pipe 40mm dia complete |
| 60 | Providing and fixing600x450mmbevellededgemirror of superior glass (of approvedquality) complete with 6mm thick hardboard ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 61 | Supplying and installing f Water storage tank of standard make like puff water tank in 500ltr capacity including all fixture complete. |
| 62 | P/F of ventillation fan self closing shutter type ISI marked like khaitanusha etc. |
| 63 | Providing and fixing Insulation of pipe with heat Tracers |
| 64 | Providing and fixing toilet paper holder :C.P Brass |
| 65 | Profiding and fixing Hangers of required pattern and size as per site engineer of ornamental type. Please Enable Macros to View BoQ information |