| 2 | Removal of Existing Acoustic,and false ceiling Including wall Panel Acoustic,Transportation of Debris,,Cleaning of the Seminar hall Preparing for New Acoustic Laying |
| 3 | Supplying and Installation of 12 mm thick water proof ply wood to the walls of the auditorium, as per direction of the Engineer- in-Charge, and the cost includes , loading, unloading and all lead and lift and its transportation cost. |
| 4 | Supplying and Installation of Acoustic wall or other good Acoustic Wall Panel, should be used which should have good Sound Absorption, and anti- bacterial qualities,The Design of the wall panel would be chosen by site engineer or any other competent authority, however, the design would not be custom design, and would be standard design (Plain), and the cost includes , loading, unloading and all lead and lift and its transportation cost. |
| 5 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same |
| 6 | Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 7 | Supplying and Installation of the Amplifiers, connection to speakers, if and whereever necessary, Supplier to responsible for Wiring and electrical work and supply and installation of following units specificfications :Mic Controller - 1 Unit, Amplifier-Unit-2 nos ,Collar Mic -1 No,Cordless mic- 1 set,podium with mic-1 no,TV auxillary wire etc,4 way mixer etc., complete |
| 8 | Removal Of Existing Wiring and existing Lighting arrangement and switch boards etc., complete |
| 9 | Supply and Installation of Projector and projector screen which includes the accessories,lead,lift,labour etc., complete. |
| 10 | Supply and Installation Electrical work, Including the following1. Wiring in Seminar hall2. Socket in seminar hall 10 nos3. Switchboard-10 Nos4. Ceiling mounted Fan-8 Nos5. Speaker-40 watts 4 Nos6. MCB board7 Projector Mounter8 Painting in conference hall-200 SQMTR lead,labour,etc., complete and as per the direction of Engineer in charge. |
| 11 | Supplying and Installation of AC-1.5 Tonne Five Star Rating single inverter with Stabilizers & additional copper & drain pipe etc. |
| 12 | Removal and relocatiing existing tables, recluding, Transportation of Debris, Cleaning of the seminar hall, Preparing for New Chair Installation |
| 13 | Supplying and Installation of auditoritum chair, made out of fabric upholestry with high density foam, the design and make of the chair would be choosen by the site engineer or any other competent authority, however, the design would not be custom design, and would be standard design (Like Push Back, box type, fixed chair with writing pad etc), and the cost includes , loading, unloading and all lead and lift and its transportation cost. |
| 14 | Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595 mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ≥ 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32 mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8 mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.60) |
| 15 | Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg, centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 45 watt |
| 16 | Supply and installation of anti skid floor mat with lead lift,labour etc., complete. |
| 17 | Providing & fixing Roller Blinds of reputed make 38mm round Aluminium channel with blackout fabric, telting with chain (Ball) system with all necessary fittings and fixtures as per direction of Engineer in charge and below mentioned addl. Specifications Material - Blacout Fabric Polyester Type - Translucent Mount Type - Wall/ Ceiling mount Bottom Rail Materila - Aluminum Chain driven system with length of chhain upto length of blinds Minimum Thickness of materia - 0.5 mm Colour - as per sample |
| 18 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling anddash fasteners to be paid for separately) For fixed portion: Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) |
| 19 | For shutters of doors,windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings whereever required including the cost of EPDM rubber /neoprene gasket required (Fittings shall be paid for separately). polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) |
| 20 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS:12823 GradeI Type II ,in panelling fixed in aluminium doors,windows shutters and partition frames with C.P brass/stainless steel screws etc.complete as per architectural drawing and direction of Engineer-in-charge .Pre-laminated particle board with with decorative lamination ob both sides. |
| 21 | Providing and fixing glazing in aluminium door,window,ventilator shutters and partitions etc.with EPDM rubber/neoprene gasket etc. complete as per the architectural drawing and direction of Engineer-in-charge(cost of aluminium snap beading shall br paid in basic item): with float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm ) |
| 22 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 g/L, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. |
| 23 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. |
| 24 | Providing & fixing of 3-track x 2-/3 track x 2 track with mesh and panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm,window sizes as per site requirements.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) |
| 25 | Repairs to plaster of thickness 12 mm to 20 mm(external & internal) in patches of area 2.5 sq.meters and under,including cutting the patch in proper shape ,raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground ,all complete as per direction of Engineer-in-charge Please Enable Macros to View BoQ information |