| 1 | Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth and getting out in soft/loose soil or hard/dense soil for taking up or laying of cable complete all as specified and directed. |
| 2 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms complete all as specified and directed. |
| 3 | Removal of surplus soil not exceed to a distance of 50M where directed at a level not exc . 1.5M above the starting point complete all as specified and directed. |
| 4 | Supply and laying dry river sand laid in trenches as cable cushioning and covering complete all as specified and directed. Note : Punned thickness only measured and paid |
| 5 | M & L for brick well burnt locally available sub class 'B' laid over sand cushioning to cable in trenches keeping width of brick parallel to the length of cable complete all as specified and directed. |
| 6 | Taking down old unserviceable LT UG cable from any description (trenches, walls, ceilings., etc) from various locations, including any short length, Supply and laying under ground LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 185 Sq mm, 3.5 core, with aluminium conductor with suitable size aluminium cable lugs and jointed in any description complete all as specified & directed. NOTE : 1. Excavation, cable protection bicks, pipe, PCC work for road crossing / hard standing and Sand for cushioning will be measured and paid separately.2. Cost of aluminium cable lugs , gable gland, new nut, bolt and washers of required size / description are deemed to include in this rate.(Make-havells,gloster for item no 6 to 18) |
| 7 | Description all as per ser item No 6.00 above but of size 150 sqmm 3.5 core |
| 8 | Description all as per ser item No 6.00 above but of size 120 sqmm 3.5 core |
| 9 | Description all as per ser item No 6.00 abover but of size 95 sqmm 3.5 core |
| 10 | Description all as per ser item No 6.00 above but of size 70 sqmm 3.5 core |
| 11 | Description all as per ser item No 6.00 above but of size 50 sqmm 3.5 core |
| 12 | Description all as per ser item No 6.00 above but of size 35 sqmm 3.5 core |
| 13 | Description all as per ser item No 6.00 above but of size 25 sqmm x 4 core |
| 14 | Description all as per ser item No 6.00 above but of size 16 sqmm x 4 core |
| 15 | Description all as per ser item No 6.00 abover but of size 16 sqmm x 2 core |
| 16 | Description all as per ser item No 6.00 above but of size 10 sqmm x 4 core |
| 17 | Description all as per ser item No 6.00 above but of size 10 sqmm x 2 core |
| 18 | S & F in repairs MCCB 4 Pole, current rating 400 Amp, adjustable over load and short circuit with Micro processor release setting , breaking capacity 36 KA at 415V, 50Hz, of incl necessary spreaders / cable lugs / nut, bolt and washers if required all as direcetd. |
| 19 | Description all as per ser item No 18.00 above but 4 pole 250 A, having breaking capacity 36 kA |
| 20 | Description all as per ser item No 18.00 above but 4 pole 200 A, having breaking capacity 36 kA |
| 21 | Description all as per ser item No 18.00 above but 4 pole 160 A, having breaking capacity 36 kA |
| 22 | Description all as per ser item No 18.00 abovee but 4 pole 125 A, having breaking capacity 36 kA |
| 23 | Description all as per ser item No 18.00 abovee but 4 pole 63 A, having breaking capacity 36 kA, |
| 24 | S & F in repairs MCCB 3 Pole, current rating 350 Amp, adjustable over load and short circuit with Micro processor release setting , breaking capacity 36 kA at 415V, 50Hz, of incl necessary spreaders / cable lugs / nut, bolt and washers if required all as direcetd. |
| 25 | Description all as per ser item No 24.00 above but 3 pole 250 A, having breaking capacity 36 kA |
| 26 | Description all as per ser item No 24.00 above but 3 pole 200 A, having breaking capacity 36 kA |
| 27 | Description all as per ser item No 24.00 above but 3 pole 160 A, having breaking capacity 36 kA |
| 28 | Description all as per ser item No 24.00 above but 3 pole 125 A, having breaking capacity 16 kA |
| 29 | Description all as per ser item No 24.00 abovee but 3 pole 63 A, having breaking capacity 16 kA, |
| 30 | S & F in repairs APFC Relays with auto set function having 6 + 1 steps 7 stage suitable for 415 Volts incl necessary connections all as directed. |
| 31 | S & F in repairs APFC Relays with auto set function having 4 + 1 steps 5 stage suitable for 415 Volts incl necessary connections all as directed. |
| 32 | S & F in repairs APFC Relays with auto set function having 3 steps 3 stage suitable for 415 Volts incl necessary connections all as directed. |
| 33 | S & F in repiars MPP type Box capacitor (Resin filled) three phase heavy duty type of capacity 20 to 50 KVAR rating suitable for 440 Voltage incl necessary connections all as specified. |
| 34 | S & F copper bus bar of any size with necessary provision of hole with fixing of new nut, bolt and washers of existing size in the panel board for any addition / alteration all as directed. |
| 35 | S & F in repairs Aluminium bus bar of any size with necessary provision of hole with fixing of new nut, bolt and washers of existing size in the panel board all as directed. |
| 36 | S & F in repairs of copper control cable multistranded with suitable size copper lugs crimped on both side of any type of size 25 Sqmm for internal connection incl PVC tie complete all as specified and directed. |
| 37 | Description all as per ser item No 36.00 above but of size 16 Sqmm |
| 38 | Description all as per ser item No 36.00 above but of size 10 Sqmm |
| 39 | S & F in repairs Copper wound with CTR 400/5 A rating all as directed. |
| 40 | S & F in repairs Copper wound with CTR 200/5A rating all as directed. |
| 41 | S & F in repairs Indicator Lamps (LED type) showing R,Y, B phase all as directed. |
| 42 | S & F in repairs Digital Amp Meter 0 - 500 Amp, size 96x96 mm square type with selector switch |
| 43 | S & F in repairs Digital Volt meter 0 - 400V, size 96 x 96 mm square type with selector switch |
| 44 | S & F in repairs MCB TPN 63Amps, 10 KA 'B' Curve,415 V as per all as specified and directed by Engr -in- Charge . |
| 45 | S & F in repairs MCB TPN 32 amps 10 KA 'B' Curve, 415 volts C series all as directed. |
| 46 | S & F in repairs MCB SPN 32 Amps, 10 KA 'B' Curve 240 volts all as direcetd. |
| 47 | S & F in repairs MCB SP 10 KA 'B' curve 10 Amps, 230V all as specified. |
| 48 | M & L for Earthing complete with galvanised steel earth plate, electrode,600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) connected to GI strip 32x 6 mm thick dia by mens of nuts, bolts, & washers of GI as shown in electrical plate No. 5 of SSR Part-I Connected to earthing ten point all as specified and including necessary earth pit PCC 1:3:6 chanber be 50mm thick PCC 1:2:4 chamber cover with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover , watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 40 mm dia unto 7.5 from the earth plate electrode & refilling of soil etc including necessary excavation & earth work in any strata and PCC chamber all as specified and directed by Engr-in-Charge including demolish existing earth pit taking out old materials. |
| 49 | S & F in repairs Galvanised iron strip 32 x 6 mm buried in ground / fixed on walls / ceilings by using suitable size GI saddles etc incl taking out old one all as specified. |
| 50 | Supply and fix or laying in trenches / on wall / poles / structures in repairs GI tubing light grade 50mm dia for road crossing for cable protection of the following sizes including necessary suitable size MS flat fixing clamps, fixing screws complete all as directed. |
| 51 | Supply and fix or laying in trenches / on wall / poles / structures in repairs GI tubing light grade 40mm dia for road crossing for cable protection of the following sizes including necessary suitable size MS flat fixing clamps, fixing screws complete all as directed. |
| 52 | Supply and fix in repairs clamp made up of GI strip 25 x 3 mm thick to fix in the RCC/PCC pole for tying of street light connection cable of required length / size from bottom to top of the LT pole incl necessary GI nut, bolt and washers complete all as directed. |
| 53 | Supply and fixing LED Bollard integral decorative with PMMA diffuser 10 watt of height 0.6 meter with IP 65 protection suitable for single phase 230 volts 50 HZ AC Supply including LED bulb , Poles, service wire and cement work complete all as specified and directed by Engineer-in-Charge. |
| 54 | Supply and fixing new generation, post top energy saving environmently friendly 25W , long life aesthetically designed with symmetrical light distribuiton spun aluminium landscape luminaire with high power LED as light sources. |
| 55 | Supply, installing, testing and commissioning factory made and tested LT Panel Indoor type, platform mounted of size: 800 X 200 X 1200 mm ( LxWxH ) suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated electrolytic Copper bus bars of capacity 250 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, IP-42 and made out of 2.00 mm thick CRCA mild steel sheet Wall mounted type, front opening type with aprons for cable entry, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey RAL- 7035 shade complete all as specified and directed by Engineer-in-Charge. The scope of work also comprising of the following:- BUS BAR CHAMBER:- (a) 250 Amp TPN, Copper conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.INSTRUMENT CHAMBER:- (i) Volt Meter,96mm,flush type rated 0-500V, Digital type with Volt Meter selector switch- 01 Set. (ii) Amp Meter,96mm,flush type rated 0-200A, Digital type with suitable size C.T's, and Amp Selector switch- 01 Set (iii) RYB Phase indicating light LED type with MCB 2A SP C Series- 1 Set of three. INCOMING:- (i) MCCB 160 Amps 25 KA , 4 Pole with adjustable thermal magnetic release=01 No., Make of MCCB:- Siemens / Legrand/ Schneider.OUTGOING:- (i) MCB 2 Pole 63 Amps, 415 volts , 50Hz, 10 KA = 04 Nos. , Make of MCB:- Siemens/ Legrand/ Schneider. (ii) MCB 2 Pole 10 Amps, 415 volts , 50Hz, 10 KA = 01 Nos. , Make of MCB:- Siemens/ Legrand/ Schneider. (iii) Provision for Single phase electric meter (v) Panel wiring for control circuit with copper flexible 1.5 Sq mm & power wiring minimum 10 Sqmm flexible.Note :- (i) Marking of Flat Nos on outgoing feeders of LT Panel. (ii) Time duration for replacement of LT Panel should not be more than 4 Hours. (iii) Rate quoted are deemed to be inclusive of all the fixture /fittings cater above |
| 56 | M & L for Painting of steel tubular pole 9.0 mtr long, by applying one coat of alluminium paint after scraping / brushing and cleaning the rust on pole and cross arms . Alluminium painting will be done on pole above 1.5 Mtr hight from ground level and balance 1.5 mtr from ground level will be painted by alternate layer of black and white enammelled paint ( 30 cms each) Pole Nos will be written on pole by black paint in yellow circle of 150mm dia all as directed by Engr in charge. |
| 57 | Supply and fix moulded (FRP) junction box with IP 65 protection of size 300x200x105 mm with 32 Amp 4 way heavy duty terminal block with 6 Amp MCB SP and two number of cable entry gland of standard size with suitable MS clamp to fix with pole complete all as directed |
| 58 | M&L for Sub Main wiring using FR Insulated unsheathed, multistrand copper conductor FR-LS PVC cable 2 runs of size 2.5 sqmm for phase and neutral and 1.5 Sq mm for earthing. drawn through rigid PVC conduit 20 mm dia with clamps for fixed on pole for connection from junction box to light fittings / switch complete all as directed by Engr-in-Charge. Note: Two runs of cable for phase / neutral and one run of cable for earth incl conduit will be measured and paid as one unit length. |
| 59 | M&L GI Pipe Bracket made out of Galvanised Iron Tubing 40mm bore (dia), light grade, 1.20 Metre long bent to shape as per specified for fixing Street Light Fitting including suitable size of clamps and applying Two coats of Aluminium Paint over a coat of Aluminium Primer including taking down old unserviceable GI Pipe Bracket with clamps, complete all as specified and as directed. |
| 60 | Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (Preferably in vertical position) earth pit not less than 2.25 metre below normal ground level with top edge of the earth plate not less 1.5 metre below normal ground level connected with and including GI strip of size 32x 6 MM by means of bolts and nuts check nut and washer of galvanized iron with & including PCC pit in PCC 1:2:4 type B-1, precast RCC cover 40mm thick reinforced with XPM (weight not less than 4.0Kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 7.5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 Part-I, connected to test point, and testing on completion including taking down old unsv earthing, complete all as specified and directed. Note :- (i) RCC pit cover shall be pre cast of RCC (1:2::4) type B , 80 mm thick reinforcement with 8 mm TOR steel @ 100 c/c in lie if CI cover and the rate includes in the unit rate . (ii) Earth electrode shall be protected upto test point using necessary arrangement with suitable size GI pipe and the rate includes in the unit rate. (iii) Earth pit Cover shall be painted in Red paint over a primer and the rate included in the unit rate. |
| 61 | M&L Electronic Driver with Input Voltage 220 to 240 Volt and Output Voltage suitable for LED Light Fitting of capacity 150 Watt, complete all as specified and as directed. |
| 62 | Description all as per ser item No 61.00 above but for LED Light Fitting of capacity 100 Watt. |
| 63 | Description all as per ser item No 61.00 above but for LED Light Fitting of capacity 60Watt. |
| 64 | Description all as per ser item No 61.00 above but for LED Light Fitting of capacity 45 Watt. |
| 65 | Supply and fix LED flood light fitting of 120 Watts with driver inside a pressure die cast aluminium housing with toughened front glass cover, IP65 degree of protection includig taking down of existig unserviceable flood light fitting of any description complete all as specified and directed by Engineer-in-Charge. |
| 66 | Description all as per ser item No 65.00 above but of 170 Watts |
| 67 | Description all as per ser item No 65.00 above but of 210 Watts |
| 68 | S&F 35 W High efficient LED Street light fitting with pressure die cast Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie should more than 80lm/W. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV complete as specified and directed. |
| 69 | Description all as per ser item No 68.00 above but of 60 watt. |
| 70 | Description all as per ser item No 68.00 above but of 70 watt. |
| 71 | Description all as per ser item No 68.00 above but of 90 watt |
| 72 | Description all as per ser item No 65.00 above but of 100 watt |
| 73 | Notes :- Amount of Credit Schedule for Schedule 'A' Part-ll shall be deducted from total quoted amount of BOQ to arrive at the contract sum Please Enable Macros to View BoQ information |