| 1 | Taking down old and unserviceable alumunium point wiring in batten/ conduit and make good the disturbed surface to match the existing surface, complete all as specified and directed by Engr-in-charge. |
| 2 | Taking down old and unserviceable submain wiring any size of two core including earth wire complete including batten/ conduit and make good the disturbed surface to match the existing surface complete all as directed by Engr-in-charge. |
| 3 | Taking down old and unserviceable, distribution board any type including/ sheet metal enclosures, after removing all connection and make good the disturbed surface all as directed by Engr-in-chanrge |
| 4 | M&L for Point wiring using FRLSLH PVC insulated unsheathed, multistranded copper conductor cable 1.5 sqmm drawn through and including PVC conduit of min 20 mm dia by Cutting chases for conduits and sinking's for boxes and making good to walls, floors etc fo concealed conduit wiring with modular flush box metal of GI sheet minimum 1.8 mm thick with earth terminal for safety, flush metal GI box of required modules as per site requirement and modular cover plate with support frame white in colour of required modules, 3mm thick including all fittings i.e. tees, bands and junction boxes, screws etc. complete for one light/fan/bulb point controlled by one switch 6 Amps one way using cable (1.5 Sq mm for phase and neutral and 1.5 sq mm earthing) Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate complete. Note:- (a) wiring shall be done by using colour coding (b) Earth wire shall be of green colour. |
| 5 | Description all as per ser item No 4.00 above but One 3 pin socket outlet, 5/6 Amp socket outlet on same board with other switches. |
| 6 | Description all as per ser item No 4.00 above but One 3 pin socket outlet, 5/6 Amp socket outlet on independent board. |
| 7 | Description all as per ser item No 4.00 above but One light point controlled by two 2-way switches, with cables 1.5 sq. mm size. |
| 8 | Description all as per ser item No 4.00 above but One bell / buzzer point controlled by one bell push on independent board complete all as specified and directed. |
| 9 | Supply and fixing socket, 6A - 2/3 pin combined 2 module, fabio series 6 Amps 3 pin unversal socket with child safety shutter, Shrouded terminals compatible with all standard mobile chargers, ISI marked for the same board complete all as specified and directed. |
| 10 | Supply and fixing modular switch 1 way 6A, 1 module modular Switch fabio classic white series/ Switch fabio classic white with indicator, ISI marked switch complete all as specified and directed. |
| 11 | Supply and fixing modular switch 2 way 6A, 1 module modular Switch fabio classic white series/ Switch fabio classic white with indicator, ISI marked switch complete all as specified and directed. |
| 12 | Supply and fixing modular bell/buzzer switch 1 way 6A, 1 module modular Switch fabio classic white series/ Switch fabio classic white with indicator, ISI marked switch complete all as specified and directed. |
| 13 | M & L for point wiring to one 3 pin 15/16 Amps socket outlet independent switch board, using FRLS-H PVC insulated unsheathed, multistranded copper conductor cable 2.5 sqmm drawn through and including PVC conduit of min 20 mm dia by Cutting chases for conduits and sinking's for boxes and making good to walls, floors etc for concealed conduit wiring with modular flush box metal of GI sheet minimum 1.2 mm thick with earth terminal for safety, flush metal GI box of required modules as per site requirement and modular cover plate with support frame white in colour of required modules, 3mm thick including all fittings i.e. tees, bands and junction boxes, screws etc. complete for power point controlled with cables, 2.5 sq. mm size, Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate complete. (2.5 Sqmm for Phase and neutral and 2.5 Sqmm for earthing) |
| 14 | Supply and fixing in repair Socket 6/16A - 2/3 pin combined 2 module,(Fabio classic white) shuttered socket (heavy duty) 3 pin unversal socket with child safety shutter, Shrouded terminals compatible 2 ton AC and 3.5 KW geyser, ISI marked for the same board complete all as specified and directed. |
| 15 | Supply and fixing in repair modular Switch fabio classic white series/ Switch fabio classic white with indicator, ISI marked 16 Amps One Way switch complete all as specified and directed. |
| 16 | Material & Labour for point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn through and including PVC casing & caping on surface of wall, not less than 25mm width confirming to IS 9537 (Part-III) 1983, including all accessories like bend, tees, junction boxes etc., 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc and including sunken type pressed steel terminal box with 1.8 mm wall thickness, of suitable size for flush type switch with cover plate, cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate complete. Note - Colour code of cable Phase-Red Neutral- Black and Earth -Green) |
| 17 | Description all as per ser item No 16.00 above but One 3 pin 5 amps socket outlet point on same board complete all as specified and directed. |
| 18 | Description all as per ser item No 16.00 above but One 3 pin 5 amps socket outlet point on independent board complete all as specified and directed. |
| 19 | Description all as per ser item No 16.00 above but wiring with cable 4 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch. |
| 20 | Description all as per ser item No 16.00 above but One bell / buzzer point controlled by one bell push on independent board complete all as specified and directed. |
| 21 | Supply and fixing in repair Bell push,flush type 5 Amps complete all as specified and directed. |
| 22 | Supply and fixing buzzer dingdong AC 230 Volts, single pole, 50 Hz complete all as specified and directed. |
| 23 | Supply and fixing in repair Socket outlet 2 in 1, 3 pin, 5 amp flush type ISI marked for the same board complete all as specified and directed. |
| 24 | Supply and fixing in repairs switch socket combination 5 Amps 2 in 1 flush type multipurposes for independent board complete all as specified and directed. |
| 25 | Supply and fixing in repair Switch piano, flush type single pole, one way 5 Amps 3 pin, ISI marked for the same board complete all as specified and directed. |
| 26 | Supply and fixing in repair Socket outlet 3 pin, 15 Amp, flush type , ISI marked complete all as specified and directed. |
| 27 | Supply and fixing in repair Switch piano 15 Amp, flush type single pole, ISI marked 16 AX Amps One Way switch omplete all as specified and directed. |
| 28 | Supply and fixing in repair Ceiling rose, 3 phase/PVC/polycarbonate, isolated body type complete all as specified and directed. |
| 29 | Supply and fixing in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd at site complete all as per specified and directed. |
| 30 | Supply & Fixing in repair only LED lights fitting 22 W LED 6000K (4Ft),(Warm/ Warm White) 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 31 | Supply and fixing in repair LED light fitting 2 feet, 10 watt 220 V AC (Warm/ White) decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. |
| 32 | M&L for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 4 Sqmm, earth continuity conductor of size 4.0 Sqmm to be drawn through and including PVC conduit 20mm dia medium Grade concealed in walls/roof/floors including taking down the old submain wiring all as directed by Engineer in Charge.Notes:- (i) Two wires of 4 sqmm and one wire of 4.0 sqmm and one run of PVC conduit shall be measured as one unit. |
| 33 | M&L for Sub Main wiring complete with copper conductor, multi stranded, FRLS, PVC insulated and sheathed, 6 Sq mm, two run 1100 volts grade, incl drawn through PVC suitable size counduit and 6 Sqmm single run for earthing complete all as per specified and directed. |
| 34 | M&L for Sub Main wiring complete with copper conductor, multi stranded, FRLS, PVC insulated and sheathed, 10 Sq mm, two run 1100 volts grade, incl drawn through PVC suitable size counduit and 10 Sqmm single run for earthing complete all as per specified and directed. |
| 35 | Supply and fixing in repair modular 5 stepped type electronic fan regulator- 2M 100W laser marking as reqd at site complete all as per specified and directed. |
| 36 | Supply and fixing in repair round shape slim fit down light LED 15 Watt round recess (Warm/ Warm White) 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size completecomplete all as specified and directed. |
| 37 | Supply and fixing in repair square shape 36/48 watt 220 volts AC recessed mounting type low depth aesthetically designed LED 2x2 feet flat (Warm/ Warm White) panels, with high efficiency PMMA diffuser soft glare free light (Warm/ Warm White) suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 38 | Supply and fixing in repair Sheet Metal enclosure double door for DBs when MCBs to be used TPN-4 Way with 200 Amp rated bus bar complete all as specified and directed. |
| 39 | Supply and fixing in repair Sheet Metal enclosure double door for DBs when MCBs to be used SPN- 8 Way with 200 Amp rated bus bar complete all as specified and directed. |
| 40 | Description all as per ser item No 39.00 above but SPN - 12 Way complete all as specified and directed. |
| 41 | Supply and fixing in repairs Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 25 Amp, 240 Volts complete all as specified and directed. |
| 42 | Supply and fixing in repair 415V 10KA 'B' curve miniature circuit breaker (MCB) TPN and current carrying capacity 63 Amp in the DB complete with connection testing and commissioning complete all as specified and directed. |
| 43 | Supply and fixing in repair 415V 10KA 'B' curve miniature circuit breaker (MCB) TPN and current carrying capacity 40 Amp in the DB complete with connection testing and commissioning . |
| 44 | Supply and fixing in repair amp rating 240V, 10KA 'B'curve miniature circuit breaker (MCB) SPN and current carrying capacity 63 Amps in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 45 | Supply and fixing in repair amp rating 240V, 10KA 'B'curve miniature circuit breaker (MCB) SPN and current carrying capacity 40 Amps in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 46 | Supply and fixing in repair amp rating 240V, 10KA 'B'curve miniature circuit breaker (MCB) SPN and current carrying capacity 32 Amps in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 47 | Supply and fixing repair amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) SP and current carrying capacity 5-32 Amps in the MCB DB complete with connection testing and commissioning. |
| 48 | Supply and fixing socket out let 5 Amps 3 pin flush type for the same board complete all as specified and directed. |
| 49 | Supply and fixing in repairs witch socket combination 5 Amps 2 in 1 flush type multipurposes for independent board complete all as specified and directed. |
| 50 | Supply and fixing in repair switch socket combination out let 5/16 Amps 5 in 1 flush type complete all as specified and directed. |
| 51 | Supply and fixing in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd at site complete all as per specified and directed |
| 52 | Supply and fixing in repair Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed. |
| 53 | Supply and fixing in repair Bell push,flush type 5 Amps complete all as specified and directed. |
| 54 | Supply & fix in repair Bulk head fitting energy saving 10 W LED with opal diffuser light fitting including necessary fixing arrangements including LED bulb complete all as specified and directed. |
| 55 | Renewal of Earthing complete with galvanized street earth plate electrode 600x600x6mm thick buried directly in ground (earth plate not less than 2.25mtr deep below normal ground level) with top edge of the plate not less then 1.50 mtr. below the normal ground level connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washer of galvanized iron or steel all as shown in electrical plate No 5 connected to earthing test point all as specified and testing on completion including the material and labour for:-(a) Excavation and earth work or drilling hole for electrode in any type of soil (b) PCC pit in cement concrete 1:2:4 TYPE B-1 (.c) CI cover with suitable handle (d) Funnel with watering pipe of GI 20mm nominal bore medium grade and Aluminum lugs etc all as specified.(e) 15mm nominal bore medium grade GI protection pipe up to 7.50 meter long for protection of earthing lead.(f) Requisite quantity of charcoal and common salt (g) Connection to earthing test point and testing on completion. |
| 56 | S&F LED bulp 3 to 5 watt 220 volt suitable for all type of holders complete all as specified and directed. |
| 57 | S&F LED bulp 7 to 10 watt 220 volt suitable for all type of holders complete all as specified and directed. |
| 58 | Supply and fixing in repair square shape 15 to 22 watt 220 volts AC recessed mounting type low depth aesthetically designed LED 1x1 feet flat (Warm/ Warm White) panels, with high efficiency PMMA diffuser soft glare free light (Warm/ Warm White) suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 59 | S&F 05 Amp 3 pin Top 220 volt complete all as specified and directed. |
| 60 | S&L in Repiacement of Stranded Aluminium Conductor cable PVC sheathed 1100 Volts 10 Sqmm, flat twin core all as specified and directed. |
| 61 | S & F of Energy efficient LED street Light Luminaire 30/35 watts capacity comprises a die-cast aluminium housing including connections with 2 run of 1.5 Sq mm copper unsheathed wire multistranded from ceiling rose / junction box to the connector of fitting, complete all as specified. |
| 62 | M & L for disconnecting electric supply from electric meters and dismantling bldg electric distribution panels of any size including MCCB, MCBs volt & ammeter and control wiring etc complete at various OTM, Offrs and JCO/OR accn and material and labour for denting, panel doors as per site, one coat of red oxide and two coats of powder coated synthetic enameled paint, fixing of suitable capacity new busbar,MCCBs/MCBs, Volt & Ammeter, CTs, selector switch and control wiring and making connection with existing electric meters including connecting internally prewired copper conductor through PVC conduit in concealed and making good to the distrubed wall surface etc complete all as specified directed by Engr-in-Charge. Note: The rates for denting, Painting, panel doors, busbar,CTs, selector switch, PVC conduit, control wiring and making good to the distrubed wall surface are include the cost of item. (ii) MCCBs, MCBs, Volt & Ammeter inclusive in the item rate. |
| 63 | Taking down u/s ceiling fan any size or sweep after disconnecting, dismantling and removal to trade workshop for repair, complete all as specified and directed |
| 64 | Opening the unserviceable/burnt fan 1200/1400 mm sweep and cutting of old burnt copper winding and rewinding the same with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnish, reassembling, testing and connecting for satisfactory run, complete all as specified and directed. |
| 65 | Supply and replacing of Ball bearing of the ceiling fan (any sweep) as per existing size incl greasing/oiling, complete all as specified and directed. |
| 66 | Supply and replacenment gun metal bushes of surface size for ceiling fan/ceiling fan incl necessary mechanical work, complete all as specified and directed. |
| 67 | Supply and replacing of cord cable, three core 0.5 Sqmm PVC insulated copper conductor cable for connecting ceiling fan, complete all as specified and directed. |
| 68 | Supply and replacing electronic step type fan regulator 240 Volt, 50 C/S, five step, suitable for 1200/1400mm sweep ceiling fan,complete all as specified and directed. |
| 69 | Supply and Fix Capacitor of of 2.5 MFD for ceiling fan, complete all as specified and directed. |
| 70 | Supply and Fix Capacitor of 4 Mfd for exhaust fan, complete all as specified and directed. |
| 71 | M & L for replacement ceiling fan blade set of three heavy duty suitable for 1200/1400mm sweep of suitable approved make as direcetd by Engr-in-Charge. |
| 72 | Supply and Fix PVC canopy for ceiling fan 1200/1400mm sweep complete for various makes/model of fan, complete all as specified and directed. |
| 73 | M & L for Disconnecting and taking down exhaust fan and blades any size or sweep after dismantling and removal to trade workshop for repair, complete all as specified and directed. |
| 74 | M & L for strip opening and cutting of old burnt copper winding of exhaust fan and rewinding of exhaust fan motor of sweep 450mm with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnish, re-assembling, testing and connecting for satisfactory run, complete all as specified and directed. |
| 75 | Description all as per ser item No 74.00 above but of 300mm sweep. |
| 76 | M & L for Ball bearing of exhaust fan of any size/make as per the existing, complete all as specified and directed. |
| 77 | M & L for painting the exhaust fan including louvers of size 300/450mm sweep with two coats of synthetic enamel paint after cleaning and making the surface of oil/dust free, complete all as specified and directed. |
| 78 | M & L for servicing of Geyser by disconnecting the electric and water supply connections, dismantling the geysers of any size, type & capacity and opening the top and bottom cover, thermostat, heating element, safety valve, vent pipe, separating inner & outer tank, removing glass wool insulation complete and keeping aside for re-use after de-scaling of inner tank by liquid chemical and with pressure water jet and assembling back the geyser including re-installation on wall with studs, nuts & bolts complete and testing after reconnecting electric and water connections, complete all as specified and directed. |
| 79 | Supply and fiixing of Heating element for geyser of cap 1.5KW, AC 230 Volts, 50 Hz (as per sample), complete all as specified and directed. |
| 80 | Supply and fiixing Heating element for geyser of cap 2.0KW, AC 230 Volts, 50 Hz (as per sample), complete all as specified and directed. |
| 81 | Supply and fiixing thermostat for Geyser of capacity 25/50/100 ltr (long size) with temperature setting adjustment range from 40 to 85°C, ISI Marked, complete all as specified and directed. |
| 82 | Supply and fiixing Geyser Syphon Assembly Set suitable for 25 ltr capacity geyser, fixed in replacement, complete all as specified and directed. |
| 83 | Description all as per ser item No 82.00 above but for 50 Ltr capacity. |
| 84 | Description all as per ser item No 82.00 above but for 100 Ltr capacity. |
| 85 | S & F Rubber gasket for water heater storage type of any capacity fixed, in replacement and suitable as per the existing, complete all as specified and directed |
| 86 | Taking down old unserviceable plug top from geyser connection and Supply and Fixing in replacement plug top 15/16 Amps for Geyser, complete all as specified and directed. |
| 87 | S & F PVC sheathed three core copper conductor flexible wire of size 2.5 Sqmm for connecting geyser, complete all as specified and directed. |
| 88 | S &F Sheet Metal Enclosure with socket, plug top and MCBs single pole and neutral enclosures with a two pin and earth plug and socket complete with one single pole MCB 20 Amps 240 Volts, complete all as specified and directed. |
| 89 | Supply and replacement of safety valve for geyser of 25/35/50 litre capacity, complete all as specified and directed |
| 90 | Supply and replacement of non return valve 15mm dia for geyser of 25/50 litre capacity, complete all as specified and directed. |
| 91 | Supply and replacement of heavy duty PVC connector 600mm long 15mm dia with PTMT nut for geyser of 25/50 litre capacity, complete all as specified and directed. |
| 92 | M & L for disconnecting and taking out geyser of capacity 25 litre and replacement of copper/SS inner tank and refilling of glass wool, refixing, connecting and testing, complete all as specified and directed. |
| 93 | Description all as per ser item No 92.00 above but for 50 Ltr capacity complete all as specified and directed. |
| 94 | Description all as per ser item No 92.00 above but for 100 Ltr capacity complete all as specified and directed. |
| 95 | Taking down old unserviceable and supply & fixing stop cock brass 15mm dia not less than 200 grams, complete all as specified and directed. |
| 96 | M & L for preparation of surface of Geyser of capacity 25/50/100 Ltr by scarping, removing old paint etc and applying two coats of synthetic enamel paint over one coat of red oxide primer,complete all as specified and directed. |
| 97 | Supply and fixing of geyser Bolt 120mm Long with nut & washers, complete all as specified and directed |
| 98 | Servicing and overhauling of refrigerator of 165 to 200 ltr capacity of various make and model incl transporting to workshop & back complete. |
| 99 | Taking out the burnt/ unserviceable compressor from the refrigerator of 165 to 200 ltr capacity and supply & fixing the same as per the existing complete all as specified and directed. |
| 100 | M & L for replacement of thermostat for refrigerator of 165 to 200 ltr capacity complete all as specified and directed. |
| 101 | M & L for replacement of thermal relay for refrigerator of 165 to 200 ltr capacity complete all as specified and directed. |
| 102 | M & L for charging of refrigerant R134A and testing for proper cooling and leakage complete for refrigerator and deepfreezers of any capacity complete all as specified and directed. |
| 103 | Taking out the burnt/ unserviceable compressor from the refrigerator of 210 to 320 ltr capacity and supply & fixing the same as per the existing complete all as specified and directed. |
| 104 | M & L replacement of thermostat for refrigerator of 210 to 320 litre capacity. |
| 105 | M & L for replacement of thermal relay for refrigerator of 210 to 320 litre capacity complete all as specified and directed. |
| 106 | Servicing and overhauling of defreezer of 210 to 400 ltr capacity of various make and model incl transporting to workshop complete. |
| 107 | Taking out the burnt/ unserviceable compressor from the defreezer of 210 to 320 ltr capacity and supply & fixing the same as per the existing complete all as specified and directed. |
| 108 | M & L for replacement of thermostat for defreezer of 210 to 320 litre capacity complete all as specified and directed. |
| 109 | M & L for replacement of thermal relay for defreezer of 210 to 320 litre capacity complete all as specified and directed. |
| 110 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece including old unserviceable geyser deposited to MES/EM store yard complete all as specified and directed by Engineer in Charge. |
| 111 | M & L for painting to the outer surfaces of refrigerator of size 165 to 320 litre with two coats of synthetic enamel paint after cleaning the surface oil/dust free and making the surfaces smooth by filling putty where required, complete all as specified and directed. |
| 112 | M & L for repair to unserviceable/burnt stabilizer of 3 KVA to 5 KVA capacity, rewinding the same with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnish, reassembling, replacement of knobs, LED's etc. and making fully functional on load as connected to Refrigerator/Deep freezer/AC, complete all specified and directed by Engr- in-charge. |
| 113 | Description all as per ser item No 112.00 above but for stablizer of 1 KVA capacity complete all as specified and directed. |
| 114 | M & L for repair to unserviceable/burnt piller heater of capacity 1000/1500/2000 watt, single phase 230volts by replacing the heater rod,blower motor, switches including wiring etc. complete all specified and directed by Engr- in-charge. |
| 115 | M & L for painting the exhaust fan including louvers of size 300/450mm sweep with two coats of synthetic enamel paint after cleaning and making the surface of oil/dust free, complete all as specified and directed. |
| 116 | Disconnecting the electric supply from the mains, transporting the window/split type air conditioner 2.0 Ton capacity from original location to workshop to carry out the servicing complete and re-fixing at the original position after repairs and making the ACs fully functional and testing for satisfactory working, complete all as specified and directed. |
| 117 | S&F in replacement of copper winding motor for 300 MM sweep exchast fan with iron body suitable bearing, shaft and complete fittings all as specified and directed. |
| 118 | Description all as per ser item No 117.00 above but 450 MM sweep complete all as specified and directed. |
| 119 | S&F in replacement of Blades for 300 MM sweep exchast fan with Screws/nuts completeall as specified and directed. |
| 120 | Description all as per ser item No 119.00 above but 450 MM sweep complete all as specified and directed. |
| 121 | S&F in replacement of clamp assembly with nuts and bolts suitable for 300 MM sweep complete fixing arrangement all as specified and directed. |
| 122 | Description all as per ser item No 121.00 above but 450 MM sweep complete all as specified and directed. |
| 123 | S&F in replacement of louvers for 300 MM sweep exchast fan all as specified and directed. |
| 124 | Description all as per ser item No 123.00 above but 450 MM sweep all as specified and directed. |
| 125 | Notes :- Amount of Credit Schedule for Schedule 'A' Part-ll shall be deducted from total quoted amount of BOQ to arrive at the contract sum. Please Enable Macros to View BoQ information |