| 1 | Excavation in trenches in any type of soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out hard dense soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. complete all as specified and directed by Engineer-in-Charge.Note (i) Excavation shall be made carefully in order to avoid damage of existing cables and brick protection.(ii) The excavation work may be carried out in short lengths for locating fault in under ground cables at different locations |
| 2 | Description all as per Item Sr No. 1.00 here in before but depth beyond first 1.5 m and not exceeding 3m complete all as specified and directed. |
| 3 | M&L for Returning, filling in including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed and tested complete all as specified and directed by Engineer-in-Charge. |
| 4 | M&L for Removal of surplus excavated soils not exceeding 50 Mtr distance and Cu depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 5 | Material & labour for sand filling with clean dry find sand unwashed including Cu gently punning around cables in trenches/ducts for cable protection complete all as specified and directed by Engineer-in-Charge.Note: Only punned thickness shall be measured and paid. |
| 6 | Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 with flat, size 300 mm x 180mm x 40mm, confirming IS 5820 1970. ISI marked complete all as specified and directed by Engineer-in-Charge. |
| 7 | M&L for cutting chases in hard standing road/path/drain etc for passing R cables/pipes etc size of cutting 150 mm wide and 250 mm deep and removing the excavated materials and disposal at 50 metre distance and making good the cutting after the pipe and cables are laid with PCC 1:3:6 type C-1 using 20mm graded stone aggregates complete all as specified and directed. |
| 8 | M&L for PCC 12:4 type B2 with 40 mm graded crushed stone aggregate as in foundation for outstanding around pole near feeder pillar/LT panel foundation of stays, including form work, fair finishing to exposed surface complete all as specified and as directed by Engr-in-Charge. |
| 9 | Supply & fixing cross arms tracing, supports, clamps and back plates fabricated from structural steel sections including nuts & bolts, washers welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge. |
| 10 | Supply laying & testing cable XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured, electric power cables (heavy duty)withstranded aluminium conductor, 11000 volts grade, of size 3 core 120 sq mm complete all as specified and directed. |
| 11 | Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed. |
| 12 | Supplying, laying & jointing Gl water tubing, 80 mm bore, Meduim grade ISI Marked incl fittings as in sleeving etc laid in trenches / ducts/Road etc complete all as specified and directed by Engineer-in-Charge |
| 13 | Dismantling carefully of steel tubular Poles/Struuts, any size and removing the same from sile and deposited to MES store complete all as specified complete all as specified and directed by Engineer in charge |
| 14 | Dismantling cross-arms of M S. channel or angle sections etc. complete and setting aside and deposited to MES store complete all as specified and directed Dy Engineer-in-Charge |
| 15 | Dismantling of ACSR or AAC conductors of any size and set in site and deposited to MES store etc complete all as specified and directed by Engineer-In-Charge. |
| 16 | Dismantling carefully HT insulators any type, any size on HT four pole structure or OHT Line and deposited to MES store complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |