| 1 | Demolition of cement concrete in ground floors and pavings n.exc 15cm thickness (below or above ground level). |
| 2 | M&L 75 mm thick PCC (1:4:8 ) type D-2 as in sub base finished even and rough, complete all as specified and as directed. |
| 3 | M&L Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern (glossy finish) as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including dismentling of tile & 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed. |
| 4 | M&L for PCC 1:2:4 type B-0 using 12.5 mm graded agregate as in copings complete all as specified and as directed. |
| 5 | M&L for PCC 1:4:8 type D-2 (using 40mm graded stone agg) as in foundation filling and mass concrete. |
| 6 | Dismantling posts or struts (wood, Steel or RCC) any section including taking out embedded portion and maiking good disturbed ground complete all as specified |
| 7 | Dismantling fencing wire mesh, any type complete all as specified and directed |
| 8 | Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified |
| 9 | S & F Chain link fencing, 4mm dia MS galvanised fencing size 75 x 75mm mesh, made up into mattressess or cages, lapped, wired and laid in position incl fixing in angle iron post complete all as specified and as directed |
| 10 | S&F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, fordoors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming toFe-290 Gde E-165 |
| 11 | S&F 2mm thick Fibre glass reinforced translucent plain sheeting with fixed with coach screw and washer in roof, wall etc by Engr-in-Charge. |
| 12 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed |
| 13 | M&L Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 |
| 14 | S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed |
| 15 | M & L For Providing precast cement concrete(1:2:4 type B0) louvres and jallies(Jafari) ,25mm thick (measured solid), including all mould- ings including hoisting, setting in position in cement mortar 1:4, including finishing, curing, Incl. all necessary requirements complete all as specified and directed.” |
| 16 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed |
| 17 | Material & Labour for brick work with sub class `B’ bricks, straight on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed. |
| 18 | Description all as per ser item No 17.00 above, but except bricks complete all as specified and as directed. |
| 19 | Taking down cement plaster on brick or stone walls etc raking out joints hacking for key scrabbing down water etc complete. |
| 20 | M&L for rendering 15mm thick in CM (1:4) on fair faces of brick work or concrete surfaces finished even and fair complete all as specified. |
| 21 | M&L for rendering 15mm thick on fair faces of brick work in CM 1:6 finished even and fair without using extra cement complete. |
| 22 | M&L for preparation of newly plastered surfaces of wall applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed |
| 23 | M&L preparing new plastered or unplastered surfaces of Ceiling and applying two coats of distemper oil emulsion paint complete all as specified and as directed |
| 24 | M&L for two coats of synthetic enamel painting over a coat of red oxide zinc chrome primer on new steel surfaces over 10cm width or girth including preparation of surface complete all as specified and as directed. |
| 25 | M&L raking out joints/ pointing to squared rubble stone masonry, coursed or uncoursed built in cement or cement lime mortar as in wall or drain, etc complete all as specified and as directed |
| 26 | M&L Walling of random rubble stone masonry, uncoursed, well bonded, built in cement mortar 1:4 in retaining walls, abutments and similar work complete all as specified and as directed |
| 27 | Description all as per ser item No 26.00 above, but except stone complete all as specified and as directed |
| 28 | M&L for flush pointing to stone random rubble masonry, uncoursed or brought upto courses in cement mortar 1:3 as in drain, retaining etc. complete all as specified and as directed. |
| 29 | M&L for PCC 1:3:6, type C-2 using 40 mm graded crushed stone aggregates in surface channels and drains complete all as specified and directed . |
| 30 | M&L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and as directed. |
| 31 | M&L for cleaning of SGSW /RCC/PVC sewage line upto 250mm dia by rodding/auger rods & drain pipe machine as required for one manhole to another manhole including gully traps and getting out the sludge from any size of manholes and gully traps, before & after cleaning process of SGSW /RCC/PVC sewage line and well flushing using clean water through water bowser of pipe of any capacity (arranged by the contractor) and removing the sludge etc to a distance n.exc 250m and burying the same underground by digging pit of suitable size from habitant area and returning filling with excavated materials up to ground level including removal of surplus soil to a distance n.exc 250m with and including taking off manholes/gully trap covers and re-fixing the same after cleaning process complete all as specified and directed. |
| 32 | M&L for dewatering of contaminated waste effluent from septic tank soakage well of any capacity by sewer jetting cum suction machine vehicle/ honey sucker machine vehicle from any location with and including taking off & re-fixing manholes covers etc. complete all as specified and directed. |
| 33 | M&L for Cleaning of septic tank of any capacity and depth incl inlet chamber, outlet chamber after mixing of contaminated waste effluent and sludge etc of septic tank by mixing machine to change the state of solid/semi solid sludge to liquid state by using extra water provided by the contractor if required and getting out through sewer jetting cum suction machine vehicle from any location and disposal to suitable place i.e. authorised civil location with and including taking off & re-fixing manholes covers etc. complete all as specified and directed. Notes :(a) Cost of excavation of pit and covering the same with earth is to be included in unit rate. (b) Note for item no. 1 to 3:- (i) The contractor/site superivisor will attend the complaint cell of AGE B/R-II to receive the complaint slips daily at 09:00 hrs to carry out the complaints within 48 hrs from receipt of complaint slip and completion report will be submitted to concerned JE/AGE. |
| 34 | Description all as per ser item No 33.00 above, but depth exc 1.5m and not exc 3 mtr complete all as specified and as directed. |
| 35 | Demoliton/breaking of drain pipes (salt glazed ware,AC or reinforced concrete) set in cement mortar and taking out off trenches and removing the debris from the site all as spd of 150mm dia pipe complete all as specified and as directed. |
| 36 | M&L 150 mm bore Reinforced concrete pipes, class NP3, laid and jointed completewith collars laid in trenches in concrete padding jointed in cement mortar 1:1 all as specified and directed. |
| 37 | M&L 200 mm bore Reinforced concrete pipes, class NP3, laid and jointed completewith collars laid in trenches in concrete padding jointed in cement mortar 1:1 all as specified and directed. |
| 38 | M&L concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8, type D2 for 150mm bore complete all as specified and as directed. |
| 39 | M&L concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8, type D2 for 200mm bore complete all as specified and as directed. |
| 40 | Excavation in trenches, n exc 1.5m wide n exc 1.5m in depth: for foundation, etc, or for shafts , wells cesspits, manholes, pier holes, etc . n exc 10 Sqm on plan and n exc 1.5m in depth and getting out, in any type of soil. |
| 41 | Returning Filling in,including spreading, levelling, watering and well ramming in layers, not exc 25 cm in soft/loose soil. |
| 42 | Removing excavated materials to a distance not exc. 50 mtr and depositing where directed at a level n exc 1.5m above the starting point. |
| 43 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) incement concrete 1:2:4 type B1 smooth finished and reforming benching as required of 150mm dia pipe complete all as specified and as directed. |
| 44 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for. |
| 45 | M&L for Providing precast cement concrete 1:2:4, type B1 (20 mm graded aggregate) set in CM 1:6, as in cover slabs (for manholes etc) with plain fair faces, complete all as specified and as directed. |
| 46 | M&L reinforced cement concrete (nominal mix) in slabs supported on walls, beams and columns in floors,roofs, landings,balconies,canopies,deck slabs and in shelves and the like, type B1 1:2:4 (20mm graded aggregate) complete all as specified and as directed. |
| 47 | M&L TMT Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified. |
| 48 | Use and waste form work to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work, not exceeding 200mm thick (horizontal or sloping) for fair finished surface of flat surface of concrete complete all as specified and as directed. |
| 49 | Form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10 cm but not exceeding 20cm wide for fair finished surface of concrete. |
| 50 | S&F in repair water closet white vitreous china ware Orissa pattern of size 580x440mm with integral foot rest 'P' or 'S' trap front or back intlet incl provision of PCC 1:2:4 type B1,and provn of lime concrete bedding and making good the dismantled surface and connection flush pipe (rate also including for taking off unhygienic old WC) complete all as specified and as directed. |
| 51 | S&F in repair Vitreous China wash down water closet pan pedestal pattern white incl fixing bolts,include S&F white coloured plastic seat cover,CP brass jet nozzle with 600 long PVC pipe (rate also including for taking off unhygienic old WC) complete all as specified and directed. |
| 52 | S&F in repair PVC valve less, syphonic action type flushing cistern, low level with inlet, ball valve float and handle including brackets of capacity 10 ltrs incl PVC connection wih brass nut on both ends and PVC flush pipe complete all as specified and as directed. |
| 53 | S&F in repairs vitreous china wash basin pedestal type white, flat back, size 600 x 480 mm excluding taps, waste, chain & plug and porcelain stopper but including brackets, 32 mm bore waste coupling complete all as specified and directed. |
| 54 | Supply and fix in repair Vitreous china urinals, bowl type flat back, size of 600x 355x265 mm white with grating and union for discharge pipe, PVC waste pipe incl fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and incl 60mm long brass screws,complete fixing in repair complete all as specified and as directed. |
| 55 | S&F in repair chromium plated fancy type mixer for mixing hot & cold water for WHB 15 mm dia screwed down for iron pipe and fixed complete all as specified and directed. |
| 56 | S&F in repair bib taps long body C.P fancy type, cast copper alloy with crutch or butter fly handle screwed down screwed for iron pipe or for unions and fixed 15 mm bore complete all as specified and as directed. |
| 57 | S&F in repair pillar taps, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, fancy type, with or without lettered Hot or Cold with long screwed shanks and fly nut for iron pipe or for unions and fixed 15 mm bore complete all as specified and as directed. |
| 58 | S&F in repair angle cock, long shank fancy type C.P. cast copper alloy screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe or for unions and fixed 15mm bore complete all as specified by Engineer-in-Charge. |
| 59 | S&F in repair stop cock, Stop valves, cast copper alloy,screwed down,high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed 15mm bore complete all as specified by Engineer-in-Charge.. |
| 60 | S&F in repair health faucet with hooks and one metre tube full brass,screwed for iron pipe and fixed complete complete all as specified and directed. |
| 61 | S&F in repair Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and directed. |
| 62 | S&F in repair Grating doom 125 mm dia of PTMT (Minimum weight 25gms) complete all as specified and directed. |
| 63 | S&F in repair 75 mm PVC (SWR) floor trap, plain with grating including jointing with solventcement complete all as specified and directed. |
| 64 | S&F in repair 600mm x 450mm bevelled edge mirror of selected quality glass,PVC mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and directed by Engr-in-charge |
| 65 | S&F in repair PVC connections 15mm size with PTMT nuts of length 600 mm for wash basin and flush tank tanks complete all as specified and directed. |
| 66 | S&F in repair PVC (SWR) pipes single socketed, in any length with rubber ring joints, laidin trenches or in floors of 110 mm dia complete all as specified and as directed. |
| 67 | Description all as per ser item No 66.00 above but 75 mm bore complete all as specified and as directed. |
| 68 | S&F in repair PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with brackets etc of 110 mm dia complete all as specified and as directed. |
| 69 | Description all as per ser item No 66.00 above but 75 mm bore complete all as specified and as directed. |
| 70 | S&F in repair PVC (SWR) bends any radius provided with access door of 110 mm dia complete all as specified and as directed. |
| 71 | S&F in repair PVC (SWR) bends any radius provided with access door of 75 mm dia complete all as specified and as directed. |
| 72 | S&F in repair PVC (SWR) bends/ shoes any radius of 110 mm dia complete all as specified and as directed. |
| 73 | S&F in repair PVC (SWR) bends/ shoes any radius of 75 mm dia complete all as specified and as directed. |
| 74 | S&F in repair PVC (SWR) branch pieces, single (equal or un equal) , ordinary or inverted (spigot or socket type) or with parralled branches of 110 mm dia with access door complete all as specified and as directed. |
| 75 | Description all as per ser item No 74.00 above but 75mm bore complete all as specified and as directed. |
| 76 | S&F in repairs PVC 'P' or 'S' of 110mm dia complete all as specified and as directed. |
| 77 | S&F in repair PVC (SWR) vent cowl of 75 mm dia complete all as specified and as directed. |
| 78 | S&F PVC in repair (SWR) vent cowl of 110 mm dia complete all as specified and as directed. |
| 79 | S&F stacks clamps out of 50mmx3mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof of any bore pipe complete all as specified and as directed. |
| 80 | M&L for Cement concrete1:5:10 type E-2 using 40 mm graded stone aggregate as in suncken floors complete all as specified and directed. |
| 81 | M&L for Preparing surface of sunken slab and applying 15mm thick cement plaster 1:3 cement sand mortar with integral water proofing compound both on floor & wall. The surface shall then be cured and allowed to dry then applying epoxy resin coating polymer modified cementation coating like brush bond of Fosroc, Pidilite and Bostic as per manufacturers instructions both on floor as well as on wall and sunken floor shall be filled with graded cinder concrete upto top level to receive top flooring, complete all as specified and directed . |
| 82 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises all as specified. |
| 83 | M&L Joint free Non-skid coloured ceramic tiles 7 to 10 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry over screed bed of 15 mm thick 1:6 and pointed in white or coloured cement to match complete all as specified and as directed |
| 84 | M&L Glazed coloured ceramic tiles in verticle surfaces 450 x 300 x 7mm thick set and jointed in neat cement slurry and pointed in coloured cement to match with backcoat of screed bed or bedding layer 10mm thick 1:4 and pointed in white or coloured cement to match complete all as specified. |
| 85 | Notes :- Amount of Credit Schedule for Schedule 'A' Part-ll shall be deducted from total quoted amount of BOQ to arrive at the contract sum. Please Enable Macros to View BoQ information |