| 1 | Dismantling of asbestos cement corrugated sheets as in roof coverings complete all as specified and directed. |
| 2 | S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick (AZ-150) of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 3 | S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick (AZ-150)of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete as specified and directed. |
| 4 | Dismantling Framed timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed. |
| 5 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed |
| 6 | M & L Brick work using Flyash old size bricks straight or curved on plan to any radius of half brick thick built in cement mortar (1:4) complete all as specified and directed. |
| 7 | M&L 15mm thick cement plastering on concrete surfaces in CM (1:4) finishing surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 8 | M&L For Cement concrete (1:4:8) type D-2, ( using 40 mm graded stone aggregate) as in foundations, filling and mass concrete etc. Complete as directed |
| 9 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 10 | S&F of Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing including distance pieces, cleats etc Fe 410 W (Gde E - 250 quality) complete all as specified and directed . |
| 11 | All as per item no 13 but febrication only complete all as specified and directed. |
| 12 | M & L two coats of synthetic enamel painting on steel surfaces exc 10 (CM) width or girth over one coat of red oxide primer including preparation of Old steel surfaces complete all as specified and directed. |
| 13 | M & L two coats of synthetic enamel painting on steel surfaces exc 10 cm width or girth over one coat of red oxide primer including preparation of new steel surfaces complete all as specified and directed. |
| 14 | S& F for Plates (plain or chequered) Fe 410-W (GdeE- 250) quality A channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment complete all as specified and directed. |
| 15 | Demolition of Concrete in ground floors and pavings including floor tiles n exc 15 cm thickness (below or above ground level) complete all as specified and directed |
| 16 | M&L for Hard core of gauge n exc 63mm thick of broken bricks spread leveling watering ramming to true surface complete all as specified and directed. |
| 17 | M&L for 75 mm thick cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate as in sub base of flooring/ hard standing & finished the surface even & fair complete all as specified and directed |
| 18 | M & L Machine cut Kota stone slab flooring 18-22mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing over and including screed bed or bedding layer of mortar 20 mm thick Cement Mortar (1:6) incl dismantling of existing kota stone Incl Screed bed complete all as specified and directed. |
| 19 | M & L Machine cut Kota stone slab flooring 18-22mm thickin riser of steps, skirting, dado and pillar laid over over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing over and including screed bed or bedding layer of mortar 15 mm thick Cement Mortar 1:6 incl dismantling of existing kota stone Incl Screed bed complete all as specified and directed. |
| 20 | Taking down copper /aluminium point wiring (light, fan, bell, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendent, regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and directed. |
| 21 | Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch/Busbar including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed. |
| 22 | Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed. |
| 23 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc and surface conduit on iron structure, pole etc, heavy duty ISI marked, with surface mount PVC box, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :-(a) One light point controlled by one, one way switch 5 Amps |
| 24 | S & F modular switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified and directed. |
| 25 | S & F for Ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified and directed |
| 26 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 1.5 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with1.5 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. |
| 27 | S & F for sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 240 volts double door with locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of disturbed surface to mtch with existing colour of wall complete all as specified and as directed. |
| 28 | S & F for MCB Single pole and neutral rated capacity 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 29 | S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 30 | S & F LED lights fitting 1x 22 W, 220V,AC Polycarbonate body with driver, holder including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specifed and directed Supply and laying river bed fine sand in trenches/ ducts 15 cm under cable and 8 cm above the cable for cushioning / protection to cable including spreading, levelling and get thick 18cm after hand punning complete all as specified and directed at site. Please Enable Macros to View BoQ information |