| 1 | Dismantling of plain or corrugated steel sheeting any gauge, thicknes, including Naintal or similar pattern roof coverings of any description etc complete all as specified and directed. |
| 2 | Dismantling wall and ceiling board fibre, pulp insulation etc or insulation boards any thickness including cover fillets complete all as specified and directed. |
| 3 | Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing) removing serviceable tiles to store and rubbish off the premises and removing the debris outside from defence land complete all as specified and directed. |
| 4 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 5 | Taking down Chowkhat or frames not exceeding 1.5 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed. |
| 6 | Taking down Shutters of any description exc. 1 sqm and not exceeding 2.00 Sqm each complete all as specified and directed. |
| 7 | Demolition of cement concrete or lime concrete (unreinforced) in ground floors and Pavings not exc 15 cm thick (below or above ground level ) and removing the debris outside from defence land complete all as specified and directed . |
| 8 | Demolition of reinforced cement concrete in roof, floor, (other than ground floor), beams, stairs, landing, chajjas and simmilar work n.exc 15 cm thick complete all as specified and directed. |
| 9 | M&L for RCC type B-1 (1:2:4) using 20 mm graded aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, deck slabs and in shelves and the like such as cover slab of septic tank/soak well etc complete all as specified and as directed. Note:- Reinforcement shall be measured and paid separately). |
| 10 | M & L for form work to the soffits and side suspended slab finish even and smooth complete all as specifed and directed. |
| 11 | M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 12 | M & L for mild steel TMT bars 6 to 8mm dia, cut to length bent to shape required, including cranking bending spirally for hooping for columns, hooking ends as in stirrups, spacers, binders etc and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and directed. |
| 13 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified complete all as specified and directed. |
| 14 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 15 | S & F 4 mm thick of size 600x600mm HSPC (high pressure Steam Cured) pre-primetered self embossed, textured designer board E-Board Classic to be fixed GI grid/section size 600mmx600mm with main runner 38x24x0.9mm thick ,cross tee 28.6x24x0.9 mm and wall angle 19x19x0.9 mm duly suspended with 2mm dia SS bar hangers 1200mm centre to centre both ways fixed with steel dash fasteners or from purlin from the roof with alignment clip including providing provisions for light fixtures of any size complete all as specified and directed. |
| 16 | M&L for 25mm thick PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate in sub base of floor to receive the floor finishes complete all as specified and directed. |
| 17 | S&F light shade vitrified ceramic tiles 8 to 10mm thick area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, each in floors laid over and including 15mm thick screed bed or bedding layer of mortar in CM (1:6) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and directed. |
| 18 | S&F light shade vitrified ceramic tiles 8 to 10mm thick on vertical surfaces such as skirting , dado risers to steps fixed over and including 10 mm thick bedding layer in CM 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles complete all as specified and directed. |
| 19 | S&F Non skid ceramic colour floor tiles of 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.06 sqm but n.exc 0.11 sqm in floors etc laid over and including 15mm thick screed bed or bedding layer of mortar in CM (1:6) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and directed. |
| 20 | S&F Non skid ceramic colour floor tiles of 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but n.exc 0.38 sqm in floors etc laid over and including 15mm thick screed bed or bedding layer of mortar in CM (1:6) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and directed. |
| 21 | M&L for coloured Glazed ceramic tiles in vertical surface such as dado, skirting etc 450mmX 300mmX 7 to 8mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of the tiles fixed over and including 10mm thick rough cement plaster to receive tiles in CM 1:4 complete all as specified and as directed. |
| 22 | M&L for 20mm thick granite work (table rubbed and polished) in steps, jambs pillars, window cills ,cooking platform and like including pointing in white cement (1:2) using marble dust with admixture of pigments to match with shade or granite over including 15mm thick screed bed or bedding layer in cement mortar 1:6 etc complete all as specified and directed. |
| 23 | M&L for Mirror polishing on marble/ granite/Kota stone/ stone work where ever required to give high gloss finish complete all as specified and as directed. |
| 24 | S&F Steel work in tubular trusses, post, purlin including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade st 240 complete all as specified and directed. |
| 25 | M&L for rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, pipe, channel or flat sections) including distance pieces, cleats etc conforming to Fe 410-W (Gde-E 250) quality-A complete all as specified and directed. |
| 26 | S & F solid PVC door frame of size 50 x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube suppling fixing in opening as per specification & drawing complete all as specified & directed. |
| 27 | S & F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame, made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC , ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for to rail & bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, & fixing in the frame at site as per specification & drawings of SSR (Part-II). |
| 28 | S&F Sheet glass 4.8mm thick clear/sun shade colour glass, ordinary quality and glazing with oil putty in squares exceeding 0.5sqm in each pane complete all as specified and directed. |
| 29 | S& F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staples or using metal nut and bolts complete all as specified and directed. |
| 30 | S&F 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 31 | S&F factory made single extruded WPC(Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calciumcarbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face)& 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutterand fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer -in- Charge. (Note: stainless steel butt hinges shall be paid separately) |
| 32 | S&F IInd hardwood 40mm plain framed pannelled shutter (any number of pannels) with panels of timber flats on bothe sides (feather edged) or of veneered particle board medium density wood particle board with commerical face veneers complete all as specified and directed. |
| 33 | S&F 100mm size Stainless steel butt hinges complete all as specified and directed. |
| 34 | S&F Stainless steel barrel tower bolt 200mm long of extruded section and fixed complete all as specified and directed. |
| 35 | S&F Stainless steel sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or castaluminium alloy and fixed Length of bolt in 250 mm complete all as specified and directed. |
| 36 | S&F 150mm size Aluminium handles, cast type, andised complete all as specified and directed. |
| 37 | S & F floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor, overall length of cover plate 150mm complete all as specified and directed. |
| 38 | M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 39 | M&L for preparation of previously treadted surfaces old wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 40 | Taking up or down 15mm bore, steel tubing and connection including cleaning for refixing or removal from site complete all as specified and directed. |
| 41 | Taking up or down 20mm bore, steel tubing and connection including cleaning for refixing or removal from site complete all as specified and directed. |
| 42 | S&F medium grade galvanized steel tubing with all fittings &fixed complete to walls & ceiling or laid in floors 15 mm dia bore pipe (including in short length) complete all as specified and directed. |
| 43 | S&F tubes medium grade galvanized with all fittings & fixed complete to walls & ceiling or laid in floors 20 mm dia bore pipe (including in short length) complete all as specified and directed. |
| 44 | S&F in repair viterous China squatting pan, `Orrisa' pattern, size 580 x440 mm white, witht integral foot rests (excluding flushing cistern and flush pipe) including connection to trap,and to flushing pipe, anti-syphonage pipe,etc. complete including making good to floor complete all as specified and as directed. |
| 45 | S&F in repair of PVC low level flushing cistern dual flush top push,10 Ltr capacity symphonic action type white as approved, ball valve float valve and handle, flush pipe incl brackets complete all as specified and directed. |
| 46 | S & F in repairs Vitreous China half stall Urinal or bowl type pattern, including connections to flushing pipe, urinal spreader, waste pipe and outgoing pipes (excluding flushing cistern) complete all as specfied and as directed. |
| 47 | S&F in repairs Viterous China wash basin with full/half Pedestal, white, flat back, size 550x400mm excluding taps etc but including brackets,including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing and supply of waste pipe complete all as specfied and as directed. |
| 48 | S&F 15mm dia 600 mm long PVC connection including brass check nut at both ends screwed both end for iron pipes complete all as specified and directed. |
| 49 | S&F CP Health Faucet with 1 mtr metalic Expandable tube & hook complete all as specified and directed. |
| 50 | S&F in repair 15mm dia bib tap long body fancy type cast copper alloy chromium plated with crutch or butterfly handle screwed down screwed for iron pipe or brass ferrule complete all as specified and as directed. |
| 51 | S&F in repair stop valves/angle valves fancy type chromium plated brass cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions fixed for 15 mm dia bore pipe complete all as specified and as directed. |
| 52 | S&F in repair 15mm bore pillar brass CP mixer for mixing hot & cold water screwed down for iron pipe complete all as specified and directed. |
| 53 | Excavation in post holes (or similar holes) each not exc 0.5 cum getting out, returning filling in and rammin earth or broken rubble mixed with earth around in layers not exc 25 cm watering, and removing surplus soil to a distance not exc 50mtr and making good surface in soft/loose soil complete all as specified and directed. |
| 54 | M & L for PCC 1:4:8 Type D-2 (using 40 mm graded aggregate) in foundations, filling and mass concrete complete all as specified and directed. |
| 55 | Demolition of brick work or stone boulder masonry built in cement mortar or cement lime including all quoins, arches, pillars etc, but excluding ashler facings, dressed stonework and precast concrete articles complete all as specified and as directed. |
| 56 | M&L for brick work with sub class 'B' bricks built in CM 1:6 straight or curved on plan & exc 6 m mean radius with old size bricks complete all as specified and directed. |
| 57 | Taking down cement plaster and raking out joints, hacking for key,scrubbing down with water built in cement mortar complete all as specified and directed. |
| 58 | M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in CM (1:6) and finished even and smooth (without using extra cement) complete all as specified and directed. |
| 59 | M&L for rendering 15mm thick in CM 1:4 other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 60 | M&L for preparation of new plastered or unplastered surface of walls including cornices, pilasters etc and applying two coats of oil bound distemper over a coat of 1mm thick wall care putty including Washing floors, cleaning glass, joinery, electric fittings,wiring etc of drops and splashes and leaving premise, clean and tidy etc complete all as specified and as directed. |
| 61 | M&L for preparation of new plastered or un plastered surface of walls including cornices, pilasters etc and applying two coats of weather proof exterior emulsion paint over a coat of primer complete all as specified and directed. |
| 62 | M&L for preparation of new surfaces of steel and iron work of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 63 | M&L for preparation of old painted surface of steel and iron work of any description over 10 cm width or girth not otherwise described and applying one coat (finishing coat) of synthetic enamel paint in any tint complete all as specified and as directed. |
| 64 | S & F draperly rod/Harrison rails of CP of 25 mm dia with fixing brackets, Stops rollers and rings etc complete all as specified and directed. |
| 65 | M&L for 75mm thick PCC 1:3:6, type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection and paving, laid in slope finished even and smooth without using extra cement including making joints at every 2.5 m and at corner filled with bitumen 85/25 and sand in ratio 1:2 by weight and complete all as specified and directed. |
| 66 | M&L for 100 mm thick PCC 1:3:6, type C-2, (using 40 mm graded stone aggregates) as in sub base/base complete all as specified and directed. |
| 67 | M & L for machine pressed precast concrete interlocking paver block with grey cement and pigmnet any shape and size confirming to IS 15658-2006 of 100 mm thickness , M-50 Grade with colour finishes on top over sand dust cushions complete all as specified and directed. Note - (Sand for cusioning will be measured and paid separately.) |
| 68 | M & L for sand filling ( as cusioning under interlocking paver block) including watering and consolidation complete all as specified . |
| 69 | M & L for PCC 1:2:4 type B-1 using 20mm graded aggregate in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 70 | S&F compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc Fe 410-W (Gde E- 250)quality -A complete all as specified and directed. |
| 71 | S&F Welded steel wire fabric (mesh) Weight N. exc 4 kg per square metre any size supplied and fixed complete to wood members or welded to steel members complete all as specified and directed. |
| 72 | M & L Water Proofing treatment on RCC roof etc comprising with the following operations complete all as directed and as specified herein below :-(a) Taking down/scrapping out existing old tarfelt bituminous compound including sweeping, cleaning, washing down to remove dust etc and removing debris to a distance n exc 250m. (b) 15mm thick plastering in cement mortar 1:4 mixed with WPC @3% by weight of cement finished even & smooth and curing for minimum 7 days(c) Preparing & Cleaning of fully dried cement plastered surface(d) Applying one coat of cold bituminous primer to the plastered surface @ 0.25 liters per Sqm conforming IS 3384-1986(e) A layer of APP based polymeric membrane 3mm thick (minimum) weighing 3.5 Kg per Sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/Sqm) shall be applied over bituminous primer as specified above application of polymeric membrance shall be by torch application. The overlap shall be minium 100mm on transverse direction and 75mm on longitudinal directions. |
| 73 | Supply only Integral water proofing compound complete all as specified and directed. |
| 74 | M & L for one coat of aluminium paint over the APP modified membrane @ 0.11 Kg/sqm complete all as specified and directed. |
| 75 | Taking down carefully existing aluminum/copper surface/concealed point wiring (light, fan, socket or power point) complete of any description including fitting such as switches, ceiling roses, lamp holder, regulators, sockets, wooden boards, laminated sheets from sunken boxes, boards, shades light fitting etc and making good the disturbed surfaces in CM 1:3 of walls, floors, ceiling etc including painting if required to match up with existing surfaces complete all as specified and directed. Note: old point wiring obtained from Sl item no 2.00 to 2.06 and 3.00 to 3.06 of Sch A. Please Enable Macros to View BoQ information |
| 76 | Taking down carefully existing aluminum/copper surface/concealed point wiring (light, fan, socket or power point) complete of any description including fitting such as switches, ceiling roses, lamp holder, regulators, sockets, wooden boards, laminated sheets from sunken boxes, boards, shades light fitting etc and making good the disturbed surfaces in CM 1:3 of walls, floors, ceiling etc including painting if required to match up with existing surfaces complete all as specified and directed. Note: old point wiring obtained from Sl item no 2.00 to 2.06 and 3.00 to 3.06 of Sch A. Please Enable Macros to View BoQ information |