|
| 1 | Sub Head - I |
| 2 | SITE CLEARANCE |
| 3 | Clearing Grass and Removal of RubbishClearing grass and removal of rubbish up to a distance of 30 m outside the periphery of the area as per MoRT&H Technical Specification Clause 201. |
| 4 | Sub Head - II |
| 5 | EARTH WORK |
| 6 | Compacting Original ground(i) Compacting orginal ground supporting Subgrade.Loosening of the ground upto a level of 500 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of Tables 300.2 for subgrade construction as per MoRT&H Technical Specification clauses of section 300. |
| 7 | (ii)Compacting original ground supporting embankment.Loosening, Levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.2 for embankment construction as per MoRT&H Technical Specification clauses of section 300. |
| 8 | (II) Excavation in Soil with Dozer with lead upto 100 m.Excavation for roadway in soil by mechanical means with Dozer including cutting and pushing the earth to site of embankment upto a distance of 100 m, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per MoRD Technical Specification Clause 302.3. |
| 9 | Construction of Embankment with Material obtained from Roadway Cutting.Construction of Embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per MoRD Technical Specification Clause 301.5.(A). For spreading beyond 100 m |
| 10 | Construction of Embankment with Material Obtained from Borrow Pits.Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per MoRD Technical Specification Clause 301.5. |
| 11 | Construction of Subgrade and Earthen ShouldersConstruction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site , spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per MoRT&H Technical Specification clauses of section 300. |
| 12 | Sub Head -III |
| 13 | PROTECTION WORK ( Retaining Wall ) |
| 14 | Excavation for StructuresEarthwork in excavation for structures as per drawing and MoRT&H technical specifications Clause 304 including setting out, construction of shoring & bracing, removal of stumps & other deleterious material and disposal upto a lead of 50 m, dressing of sides & bottom and backfilling in trenches with excavated suitable material.(I) Ordinary soil(A) By Manual Means(i) upto 3 m depth |
| 15 | Sand Filling in foundation trenches as per drawing & MoRT&H technical specification clause 304. |
| 16 | I) P.C.C grade M 10(i) Nominal mix 1 : 3 : 6 |
| 17 | I) P.C.C grade M 15(i) Nominal mix 1 : 2.5 : 5 |
| 18 | Providing weepholes in brick masonry/ stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe or uPVC pipe (110 mm OD of 6.0 Kg/cm2 pressure) extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and MoRD technical specification clauses 614, 709, 1204.3.7. |
| 19 | Providing & laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil & bigger size towards the wall & providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and MoRD technical specification clause 1204.3.8. |
| 20 | Supplying, fitting & placing Thermo-Mechanically treated bar/ Cold twisted deformed steel bar in substructure complete as per drawings & MoRD technical specification Clauses 1002, 1005, 1010 and 1202. |
| 21 | Sub Head - IV |
| 22 | DRAINAGE WORK |
| 23 | U-SHAPED RCC DRAINExcavation for Structures(A) Without dewatering.Earthwork in excavation for structures as per drawing and MoRD technical specifications Clause 305.1 including setting out, construction of shoring & bracing, removal of stumps & other deleterious material and disposal upto a lead of 50 m, dressing of sides & bottom and backfilling in trenches with excavated suitable material.I. Ordinary Soil(i) Upto 3 m depth. |
| 24 | Filling in foundation trenches as per drawing & MoRD technical specification Clause 305.3.9, 1200.(i) Sand Filling |
| 25 | Providing concrete for plain/reinforced concrete in open foundations complete including formwork as per drawings & MoRD technical specifications Clauses 802, 803, 900, 1202 and 1203. (including centering, shuttering, staging etc. but excluding reinforcement).I. P.C.C grade M 10(i)Nominal mix 1 : 3 : 6 |
| 26 | Plain/reinforced cement concrete in substructure complete including formwork as per drawings & MoRD technical specification Clauses 802, 804, 805, 806, 807, 900, 1202 & 1204. (including centering, shuttering, staging etc. but excluding reinforcement)VI. R.C.C grade M 25(i)Nominal mix 1 : 3 : 6 |
| 27 | Supplying, fitting & placing Thermo-Mechanically treated bar/ Cold twisted deformed steel bar in substructure complete as per drawings & MoRD technical specification Clauses 1002, 1005, 1010 and 1202. |
| 28 | Sub Head - V |
| 29 | GRANULAR SUB - BASES, BASES( Non -Bituminous ) AND SHOULDERS. |
| 30 | 2) WBM Grading IIProviding, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/ binding materials to fill up the interstices of coarse aggregate, watering and compacting to the required density 'Grading 2' as per MoRD Technical Specification Clause 405.(A) By Manual Means |
| 31 | 2) WBM Grading IIIProviding, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/ binding materials to fill up the interstices of coarse aggregate, watering and compacting to the required density 'Grading 2' as per MoRD Technical Specification Clause 405.(A) By Manual Means |
| 32 | Sub Head - VI |
| 33 | BASES AND SURFACE COURSES ( Bituminous ) |
| 34 | Maintenance of bituminous surface road.I. Repair to pot holes by removal of failed material, trimming the sides to vertical and levelling the bottom, cleaning the same with compressed air or any appropriate method, filled with 75 mm B.M, after applying bitumen emulsion prime coat at the bottom and bitumen emulsion tack coat on sides and on bottom as per MoRD technical specification Clauses 1900, 502, 503 and 504. |
| 35 | II. Patch repair on already filled pot holes with 75 mm BM with 20 mm premix carpet and seal coat type A as per drawing and MoRD technical specification Clauses 1904.2, 508 and 510. |
| 36 | Prime Coat(II) Medium PorosityProviding and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.6 kg/sqm using mechanical means as per MoRT&H Technical Specification Clause 502. |
| 37 | Tack Coat(iii) Providing and applying tack coat with bitumen emulsion (RS-1) using emulsion pressure distributor at the rate of 0.20 kg per sqm on the prepared bituminous / granular surface cleaned with Hydraulic broom as per MoRT&H Technical Specification Clause 503. |
| 38 | Dense Graded Bituminous MacadamProviding and laying dense graded bituminous macadam with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 to 4.5 per cent by weight of total mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRT&H specification clause No. 507 complete in all respects.(B) Grading II (For layer thickness 50-75 mm)i. With Viscosity Graded Bitumen of VG-30. |
| 39 | Bituminous ConcreteProviding and laying bituminous concrete with higher capacity batch type hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder @ 5.40 Percent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects.(B) Grading II (For layer thickness 30 - 40 mm)i. With Viscosity Graded Bitumen of VG-30. |
| 40 | Sub Head -VII |
| 41 | TRAFFIC SIGN, MARKINGS & OTHER ROAD APPURTENANCES |
| 42 | Retro-reflectorised Traffic SignsProviding and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of high intensity grade shetting vide MoRT&H technical specification Clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and MoRT&H Technical Specification Clause 801. |
| 43 | (i) with 900 mm equilateral triangle |
| 44 | (iii) with 600 mm circular |
| 45 | (iii) with 600x450 mm rectangular |
| 46 | (iii) with 900 mm octagon |
| 47 | Direction and Place Identification B) Semi Reflective Traffic SignsSigns with upto 0.9 sqm Size board.Providing and erecting and place identifications of semi reflective sign boards as per IRC:67 made of 2 mm thick M.S. sheet duly stove enameled paint in white colour in front and gray colour on back with red reflective border of 70 mm width and required message, letters and figures with reflective engineering grade tape as per MORD specifications of required shade and colour. Supported and welded on 47 mm x 47 mm x 12 SWG square tube of 3050 mm height duly strengthened by 25 mm x 5 mm MS flat iron on edges on back firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete (using jhama brick aggregate) 450 mm x 450 mm x 600 mm, 600 mm bellow ground level as per approved drawings and MoRD Technical Specification Clause 1701. |
| 48 | Kilo Metre Stone( With RCC M15 gradeusing Jhama Brick aggregate)Reinforced cement concrete M 15 grade kilometre stone of standard design as per IRC:8, fixing in position including painting and printing, etc. as per drawing and MoRT&H Technical Specification Clause 804. (ii) Ordinary Kilometre Stone(precast) |
| 49 | Boundary Pillar (with PCC M15 grade using jhama brick aggregate and reinforcement).Plain cement concrete M15 grade (using jhama brick aggregate and reinforcement) boundary pillar / local stone of standard design as per IRC:25 fixed in position including finishing and lettering but excluding painting as per drawing and MoRD Technical Specification Clause 1704. |
| 50 | Construction of RCC guide posts of 250 mm dia and total 600 mm long,(300 mm below GL) M15 grade (with jhama brick aggregate) cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical RCC posts not to exceed 1 in 500 as per drawing and MoRD Technical Specification Clause 1401.6.(A) In Ordinary Soil |
| 51 | Road Marking strips (retro-reflective) of specified shade/colour using Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous SurfaceProviding and applying of 2.5 mm thick thick Road marking strips ( retro - reflective ) of specified shade / colour using hot thermoplastic material including reflectorising glass beads @ 250 gms per sqm area by fully / semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater including cost of cleaning the road surface of all dirt, seals, oil, grease and foreign materials etc, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 . The finished surface to be level, uniform and free from streaks and holes. as per MoRT&H Technical Specification Clause 803. |
| 52 | Providing and Fixing 'Citizens' Information Board' of the Project(with CC structure).Providing and fixing of typical Citizens' Information board with Logo as per MORD specifications and drawing with CC structure made with M-15 of Size 1150 mm in length, 300 mm in thickness and 2450 mm in height all above G.L. with foundation with M-15 concrete of size 1150 mm x 600 mm x 750 mm , 750 mm below ground level with skin reinforcemet with 8 mm dia TMT bars @ 200 cm C/C from bottom of the structure. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of structure will be painted with primer and two coats of epoxy paint as per drawing and MoRD technical specification Clause 1701 and Annexure 1700.1 |
| 53 | A. Board'A' |
| 54 | A. Board'B' |
| 55 | Road DelineatorsProviding and installation of delineators (road way indicators, hazard markers, object markers), 80-100 cm high above ground level, painted black and white in 15 cm wide strips, fitted with 80 x 100 mm rectangular or 75 mm dia circular reflectorised panels at the top, buried or pressed into the ground and conforming toIRC-79 and the drawings and as per MoRT&H Technical Specification Clause 806. |
| 56 | Metal Beam Crash Barrier.Type - B, \\"THRIE\\" : Metal Beam Crash BarrierProviding and erecting a \\"Thrie\\" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 85 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 2 m high with 1.15 m below ground level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with aspace of channel section 150 x 75 x 5 mm, 546 mm long complete as per MoRT&H Technical Specification Clause 811. |
| 57 | Road Markers/Road Stud with Lense Reflector.Providing and fixing of road stud 100 x 100 mm, die-cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling hole 30 mm upto a depth of 60 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS 873 part 4:1973. |
| 58 | Sub Head -VII |
| 59 | Box Culvert |
| 60 | Excavation for StructuresEarthwork in excavation for structures as per drawing and MoRT&H technical specifications Clause 304 including setting out, construction of shoring & bracing, removal of stumps & other deleterious material and disposal upto a lead of 50 m, dressing of sides & bottom and backfilling in trenches with excavated suitable material.i) In ordinary soilA.By Manual Meansi) Upto 3 m depth |
| 61 | Backfilling behind abutment, wing wall & return wall complete as per drawings, clause 710.1.4 of IRC:78 & MoRT&H technical specification Clause 2200.(II) Sandy material |
| 62 | Providing concrete for plain/reinforced concrete in open foundations complete including formwork as per drawings & MoRD technical specifications Clauses 802, 803, 900, 1202 and 1203. (including centering, shuttering, staging etc. but excluding reinforcement). |
| 63 | I) P.C.C grade M 10(i) Nominal mix 1 : 3 : 6 |
| 64 | I) P.C.C grade M 15(i) Nominal mix 1 : 2.5 : 5 |
| 65 | Plain / Reinforced cement concrete in open foundation as per drawings & MoRT&H technical specifications Clauses 1500, 1700, 2100. (including centering, shuttering, staging etc. but excluding reinforcement) (VI). PCC Grade M 25(i) Up to 5 m height. |
| 66 | Supplying, fitting & placing Thermo-Mechanically treated bar/ Cold twisted deformed steel bar reinforcement in foundation complete as per drawings & MoRT&H technical specifications Clauses 1600. |
| 67 | Plain / Reinforced cement concrete in open foundation as per drawings & MoRT&H technical specifications Clauses 1500, 1700, 2100. (including centering, shuttering, staging etc. but excluding reinforcement)E. RCC Grade M 25Case - I : Using Concrete Mixer |
| 68 | Supplying, fitting & placing Thermo-Mechanically treated bar/ Cold twisted deformed steel bar reinforcement in foundation complete as per drawings & MoRT&H technical specifications Clauses 1600. |
| 69 | Providing & laying filter media with jhama brick aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil & bigger size towards the wall & providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and MoRT&H technical specification clause 2504.2.2 |
| 70 | Providing weepholes in brick masonry/ stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe or uPVC pipe (110 mm OD of 6.0 Kg/cm2 pressure) extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and MoRT&H technical specification clauses 2706, 2200. |
| 71 | Providing and placing in position drainage Spouts complete as per drawing (SD/205) and MoRT&H Technical Specification Clause 515, 2705. |
| 72 | Brick soling.Brick on edge soling.Providing and laying brick on edge soling layer on prepared subgrade according to lines, grades and cross-section shown on the drawing, filling joints with sand, watering and rolling the same with three wheeled road roller 80-100 kN as per MoRD Technical Specification Clause 412. |
| 73 | Brick masonry work in cement mortar in substructure complete excepting pointing & plastering, as per drawing & MoRD technical specification Clauses 602, 603, 604, 1202 and 1204. II. In 1:4 cement mortar |
| 74 | Reinforced Cement Concrete M 25 grade approach slab including reinforcement & formwork complete as per drawing & MoRD technical specifications Clauses 800 & 1211 (including centering, shuttering, staging etc. and reinforcement) |
| 75 | Construction of R.C.C railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line & grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm including reinforcement as per drawing and MoRD technical specifications Clauses 800, 900 and 1208.3 (including centering, shuttering, staging etc. and reinforcement). |
| 76 | 5 Year Maintenance |
| 77 | 1st Year Maintenance |
| 78 | 1st Year Maintenance |
| 79 | 1st Year Maintenance |
| 80 | 1st Year Maintenance |
| 81 | 1st Year Maintenance Please Enable Macros to View BoQ information |