| 1 | [13.32]Providing and fixing bolts including nuts and washers complete. [Through Rate] |
| 2 | [24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate] |
| 3 | [24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate] |
| 4 | [24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate] |
| 5 | [24.16.7]HT CABLES (Aluminium Conductor, Armoured and Unarmoured) Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 7. Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 185 Sq mm 3 core [Through Rate] |
| 6 | [24.3.3.2]HT CABLE 3.2. Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :150 to 185 sqmm [Through Rate] |
| 7 | [24.3.4.2]HT CABLE 4.2. Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 150 to 185 sqmm [Through Rate] |
| 8 | [24.5.2.7]MISCELLANEOUS ITEMS 2.7. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 180/150 mm outer dia/ inner dia [Through Rate]Make:- Havell's/Polycab/Gemscab/Grandlay) |
| 9 | Supply and erection of 800 Amp. 11 KV Indoor type incoming VCB Panel of standard size of U.T. Electricity Deptt. specification 500 MVA 25 KA Motorized with Copper bus bar, closing ,Trip coil, Electrical and Mechanical interlocking in VCB Panel with protection relay as per specification complete in all respect upto the entire satisfaction of Engineer-InCharge.Make : Crompton/Griaves/Schenider/CandS/Equivalentmake as per approved make and specification of UHBVN/DHBVN |
| 10 | Supply and Erection of G.I. V shape cross arm suitable for 11 KV system made out of G.I. channel of size 100x50x50x6mm (ICMC100) as per design and drawing of UHBVN 13.2 kg. 2 Nos. 18mm dia holes provided in the base for fixing of half clamp 2 Nos. holes 22mm dia for GI pin on the flange shall be provided on the top and bottom flanges of both end of V-shape X-arm complete in all respect (Excluding GST 18%). |
| 11 | Supply and Erection of 11 kV G.O. Switch vertical mounted with a heavy duty 9 Nos. post insulators suitable copper male and female contacts fixed on GI angle frame with G.I. Nut and Bolts including G.I. pipe and operating handle complete in all respect (Excluding GST 18%) |
| 12 | Supply and erection of 11kV Lightning Arrester as per approved makes and relevant specifications of UHBVN complete fixing with GI clamp, Nut and bolts up to entire satisfaction of Engineer-In-Charge (Ex-GST 18%) |
| 13 | Supply and Erection of 11kV polymeric Pin insulator 10 kN with GI Pin of approved makes / specification of UHBVN (Ex-GST 18%) |
| 14 | Supply and Erection of ACSR conductor 50 mm2 conforming to IS 398 (Part-II) 1976/1996, IS 4826-1976 IS 1521-1972 and IS 1778-1980 with latest amendments as per UHBVN specification including stringing and sagging as well as jointing and binding with insulators at supports complete in all respect upto the entire satisfaction of Engineer-in-Charge (Ex-GST 18%) |
| 15 | Supply and Erection of ACSR conductor 100 mm2 conforming to IS 398 (Part-II) 1976/1996, IS 4826-1976 IS 1521-1972 and IS 1778-1980 with latest amendments as per UHBVN specification including stringing and sagging as well as jointing and binding with insulators at supports complete in all respect upto the entire satisfaction of Engineer-in-Charge (Ex-GST 18%) |
| 16 | Supply and Erection of Danger plate enameled with clamp for 11 KV/33 KV line as per UHBVN specification complete in all respect (Ex-GST 18%) |
| 17 | Supply and Erection of 11 Mtr. Long PCC pole as per IS:1678-1960 specifications,11Mtr. Long 140mm x 200mm at top and 140mm × 400mm at bottom with working load of 400 Kg buried 2.20 M in ground as per UHBVNL specification.(Ex-GST 18%). |
| 18 | Supply and Erection of 11 KV polymeric disc insulator 45 KN for 11 KV overhead lines with fittings, TandC type and complete with galvanized strain clamps, bolts, nuts, washers etc. as required as per UHBVN specification (Ex-GST 18%) |
| 19 | Supply and Erection of Stay set for HT line complete with GSS 7/8 SWG, Egg, insulator/ Disc Insulator, GI rod 20mm dia threaded up to 250mm length with Nut (wt.6.224kg), cross plate 460 mm of Channel 75×40×6mm (wt.5.330kg), Elbow (wt.2.240kg), clamp with Nut-Bolts etc. as per UHBVN specification complete in all respect up to the entire satisfaction of Engineer-in-charge. (Ex-GST 18%). |
| 20 | Supply and Erection of HT Cradle Guard made of GI wire of SWG including fixing in 11kV line complete in all respect up to the entire satisfaction of the Engineer-In-Charge. (Ex-GST 18%). |
| 21 | Supply and Erection of Galvanized steel item (Flat, Angle, Channel) and Nut and Bolts etc. including cutting, bending to the required shape, drilling hole, carriage, loading-unloading complete in all respect up to the entire satisfaction of Engineer-in-charge.(Ex-GST 18%). |
| 22 | Supply, Stringing and Sagging 8 SWG G.I. Earth wire complete in all respect to the entire satisfaction of Engineer-in-charge conforming to IS 298/1978 and 7807/1973 and with latest amendment thereof. (Ex-GST 18%). |
| 23 | Supply and Erection of top hamper suitable for 11 Mtr. Long PCC pole and 11kV system made out of GI flat size 50×6mm (A shapes) having weight 2.95 kg as per approved design and drawing of UHBVN complete in all respect (Ex-GST 18%) |
| 24 | Supply and Erection of M plus 6 Extension Tower 1695 kg complete in all respect with all accessories as per approved makes and specification of UHBVN. |
| 25 | Supply and Erection of Barbed Wire G.I complete in all respect with all accessories as per approved makes and specification of UHBVN. |
| 26 | Foundation work for M plus 6 Extension Tower wt. 1695 kg complete in all respect. |
| 27 | Supply and erection of Dead end clamp Assy with eye hook complete in all respect with all accessories as per approved makes and specification of UHBVN. |
| 28 | Supply and Erection of M plus 6 Extension Tower 1695 kg with all relevant accessories etc. as per approved makes and specifications of UHBVNL/DHBVNL complete in all respects as per entire satisfaction of the Engineer-in-Charge of the work.(Rate Without GST) |
| 29 | Supply Erection testing and commissioning of 11kv 630 Amp VCB panel indoor type having one incoming and one outgoing non extensible type, with highest system voltage of 12 Kv, with a rated continuous current of 630 Amp at a 50 Hz frequency, manual and motorized charged, including powerpack, all type of control wire, protection relay with protection system to protect the transformer from all type of faults. Some technical specifications include a symmetrical breaking capacity of around 40 kA or 350 MVA, an impulse withstand voltage of 75 kvp, and power frequency withstand voltage of 28 kV. The breaker is designed for 3-phase AC system, typically indoor metal clad 11 KV including all measuring instruments CTs, PTs etc. makes as approved in UHBVNL/DHBVNL and as per the entire specification of the Engineer-in-Charge of the work.(Rates without GST) |
| 30 | Supply and Erection of Foundation for M plus 6 Extension Tower 1695 kg with all relevant accessories etc. as per approved makes and specifications of UHBVNL/DHBVNL complete in all respects as per entire satisfaction of the Engineer-in-Charge of the work.(Rate Without GST) |
| 31 | Laying of HDPE pipe by using of trenchless technology 1.5 meter below ground level and including scaning of under ground services before laying the pipe and saving the existing services like cable, gas pipe, water pipe, oil pipe , sewerage pipe or other services excluding the cost of HDPE pipe complete in all respects upto the entire satisfaction of the Engineer-in-Charge of the work.(Rate Without GST)Size 160 mm dia. |
| 32 | Supply and Erection of G.I. pipe 100 mm dia (Nominal) ISI marked (medium gauge) laid 1 meter below ground level including digging and filling of tench complete in all respects upto the entire satisfaction of the Engineer-in-Charge of the work. (Rate Without GST) Please Enable Macros to View BoQ information |