| 1 | Hot Air Oven:- • Size: 18x18x24 inches • Precise Sterilization, Incubating and drying in one unit. • Better mineral / glass wool blanket insulation keeps the surface of the Instrument from being burnt. • Silent Hot Air blower unique Design of air circulation for uniform Air movement. • Unique design of Ventilation keeps the surface of the instruments from being burnt. • Polish 304 grade S.Steel interior corrosion resistant long-life operation having adjustable shelves to make more space for different height. • Kanthal A-1, Super quality coil shaped heaters duly embedded / wounded on the sides and bottom for better accuracy. • Full feature with Touch Screen Controller Temperature Controller: • HMI Display with Feather Screen Touch Digital Temperature Controller • Continuous display of Temperature, Time, Day and Date Door Open Alarm • Password Protected operations, • Data transfer port: USB port Technical Specification: Microprocessed Electronic Digital Controller cum Indicator from few `C above ambient to 300°C ±0.5°C having two windows display SV (Set value)and PV (Process value), auto tuning, timer up 999 min (selectable) low and high temperature accuracy alarm, cycle, timer with buzzer. • Temperature Stability: ± 0.5°C • Control Panel: With Mains and Load Indicator, MCB Alarm • Material: GI/ MS with Powder Coated • Inner: Stainless Steel 304 • Digital Setting: 0.1°C • Digital Resolution: 0.1°C • Safety Function: Temp Over shoot high and Low Temp. Alarm ± 5°C, MCB Provided • Insulation: Mineral Wool • Front Door: Mineral wool insulated door with glass window • Hardware: Lock and Handle Material Zinc, Base Finish: SPC, Handle Finish: Black PC with key Hinges Material Zinc, Pin Material: SS 304 Grade, Finish STPC, Opening Angle: 180 Deg • Power Consumption: 220 /230V AC Supply ± 10%. 50 HZ • Duty Cycle: Continuous Traceability calibration certificate of controller should be provided. Instrument should be calibrated from NABL calibration laboratory. Steel stand should be provided along with tyres on which instrument has to be kept. Make: NSW, OPTICS TECHNOLOGY, AMBASSADOR, IMPACT. |
| 2 | Ultra Water Purification Unit Water Purification System for preparation of Mobile phase and standards with following specifications • Type-1 water • Pre-filtration system: Three stage pre-treatment system with 10µm, 5µmand 1µm: • 1 micron spun or provides pre-filtration with 10-micron filters for removal of suspended particles and to take care of F.I in water. • Resistivity: ) 1 MO.cm @ 25°C or in percentage • TOC: 5.0 ppb • Bacterial TVC: (1.0 cfu/ 100 mL • Microprocessor controlled management systems for continuous monitoring of water purity. • Should produce Ultra-Pure water (Type 1) from tap water for different applications. • It should be single stage system with the filter at the tap with bacteriaand should have RO, De-ionized water and UV in a single unit. It should have an integrated docking vessel of 25 L for storing the water to save space It should have recirculation facility to maintain consistent peak water purity. • Instrument should show water volume in reservoir graphically and in percentage. • It should have cartridge change indicator. The production rate of the unit should be minimum 6 Litre/hr or more and the dispense rate should be minimum 0.5 L/min or 1.0 L/min. • It should have dual wavelength UV(185/254 nm). • The manufacturer must have worldwide presence, also provide one spare cartridge. • Along with Installation of 1No R.O. system with tank capacity of 15-20 L. Make: Elga,Merck Millipore, Thermo Fischer. |
| 3 | Calibrated Weights • Standard Weight Box, Class F1, capacity 1 mg to 200 gm with NABL Accredited Lab Calibration Certificate (Set of 23 wire weights) Make: Radwag,Mettler Toledo, Sartorius, Denver, Wensar. |
| 4 | Deep Fridger with Temperature Controller • Double door deep fridger • Capacity: 300 ltr • Heavy duty wheel • Enabled temperature controller to check and maintain inside temperature • Shelf Material/Cool pad: Toughened Glass • Aesthetic soft look design. • UV grade plastic material for long-lasting appearance. • Door lock for restricted accessibility. • Castor wheels for easy mobility. • Environment friendly CFC free insulation. • Instrument should be calibrated from NABL calibration laboratory as desired by concerned lab. Make: Blue Star, CELLFROST, Western. |
| 5 | Hygrometer • Temperature Range: -50.0C ~ plus 70.0°C Temp. • Measuring Accuracy: ± 10°C Temp. • Resolution: 0.10°C Humidity • Meas.Range: 10% RH ~ 99% • Humidity Accuracy: ±5% RH • Humidity Resolution: 1%. • Along with NABL calibration certificate Make: HTC, Testo. |
| 6 | Magnetic Stirrer with Hotplate (5 station) • Magnetic stirrer 2 litres capacity with hot plate and Digital Speed Indicator • Speed: 2000 RPM • Heating Plate Material: Glass Ceramic Top Plate • Dimension of Heating Plate: 180mmx180mm • Two display windows for Temperature and RPM • Heat Output: 1300 W • Temperature Range: Ambient to 550°C • Adjustable safety cut off: 580°C • Control accuracy of sensor: ±1K • Permissible ambient Temp.: 5- 40°C • Permissible relative moisture: 80% • USB Port: Yes (for Programming) • 7 pcs Magnetic stirring bar inclusive • Dimensions of Hot Plate Body:378 mm x220 mm x103 mm • IP Class -21 Make: Borosil,Thermofisher Scientific, Glassco. |
| 7 | Two Channel Ion Meter (Dual Type) • pH Range: 2.000 to 19.999 • Resolution: 0.1, 0.01, 0.001 • Relative Accuracy: ± 0.002 • Calibration Points: 1 to 6 • Calibration Editing: Yes • Buffer Recognition: USA/NIST, EURO/DIN or manual entry of custom values • ISE Range: 0.0001 to 19900 • Resolution: 0.0001 minimum, auto ranging, up to 3 significant digits (user selectable). • Relative Accuracy: ± 0.2 mV or 0.05 %, whichever is greater • Units: ppm, ppb • Incremental Techniques: Single known addition and subtraction. Double known addition and subtraction • Calibration Points: 2 to 6 • Calibration Editing: Yes • Calibration Options: Linear point to point, non-linear selectable auto-blank, low concentration range stability mV/Rel mV/ORP • Range: ± 1999.9 • Resolution: 0.1 • Relative Accuracy: ± 0.2 mV or 0.05 %, whichever is greater • EH ORP Mode: Yes Temperature Range: 5°Cto 105°C • Resolution: 0.1 °C • Relative Accuracy: 1 point • Data logging • Memory: Minimum 1000 data points with time and date stamp • Log Function: Manual (continuous), when stable (Auto-Read, on ready), timed (at timed intervals, timed reading) or value change in measurement • Method Storage: 20 (10 per channel with calibration data and password protection) Inputs • pH Electrode or ISEBNC (2), reference pin-tip (2) • ATC Probe: 8-pin mini-DIN (2) • Stirrer Probe: Stirrer jack Output Ports: RS232, USB • PowerAC Adapter Included: universal, 100-240 VAC, 50-60 Hz • Along with Nitrate, fluoride electrode, Two number stirrers • 1-year warranty of electrode MAKE-THERMO SCIENTIFIC, HACH,WTW. |
| 8 | UV – VIS Spectrophotometer • The Spectrophotometer will be UV-Visible operation and with the reference cell position for kinetics application. • Operating Mode: Transmittance (%), absorption and Concentration (Wavelength and Time or multi-wavelengths and multi-step readings • Source Lamp: Tungsten (visible range), deuterium (UV Range)/Xenon with life )5 years typical • Wavelength Range: 190 - 1100 nm • Wavelength: ± 1 nm • Reproducibility: ( 0.1 nm • Wavelength Resolution: 0.1 nm • Wavelength Selection: Automatic, based on method Selection • Spectral Bandwidth: 2 nm • Scanning Speed: Max 2000 nm/min (in 1 nm steps) • Photometric Measuring range: ± 3 Abs • Photometric Accuracy: ±0.002 A at 0.5 A, ±0.004 A at 1.0 A, ±0.008 A at 2.0 A • Photometric Linearity: 0.005 - 2 Abs, = 0.01 at ) 2 Abs with neutral glass at 546nm • Stray Light: KI-solution at 220 nm,(3.3 Abs/(0.05% or ( 1.0%T 198 nm (KCl) or(0.05%T at 220 nm (NaI) or(0.03%T at 340 nm (NaNO2) • Display: Minimum 7-inch, color display Touch screen or keyboard display • Data Logger:5000 data points (result, date, time, sample-ID, user-ID) • Pre-programmed Methods: Minimum 200 • User Programs: Minimum 200 • Sample Cell Compatibility: Rectangular: 10,20,30,50mm ,1 inch: round: 13 mm, 16 mm, 1 inch: round:13mm,16mm Optional 100mm rectangular/Test Tube Holder for vials and test tube from 12 to 25 mm OD, 10 mm square single-cell holder, Optional Holder up to 100mm rectangular Cell/16 mm round, 10 mm, 20 mm, 50 mm rectangular with automatic detection w/o adapter. Bidder will provide all type of cell /cuvette as used in the equipment against different wavelength. Bidder will discuss with the concerned lab before submission of equipment. • Dimensions (HxWxD): Standard Dimension • Operating Conditions: 10 at 40 °C, max. 80% relative humidity (non-condensing) • Storage Conditions: Minimum plus 10 °C andmax. 60 °C max. 80% relative humidity (non-condensing) • Enclosure Rating: IP20 with closed lid/CE/TUV Certification • Interfaces: USB type A (2), USB type B Make: HACH, WTW-Xylem, Thermo Orion, Lovibond, Merck. |
| 9 | Water bath • Nominal capacity - 20 L, 8 holes with lid assembly • Working Temperature range – ambient to 99°C • Temperature stability ±2.0°C • Interior dimensions (528 x 325 x 150) mm • Exterior dimensions (W x D x H) (530 x 326 x 2600) mm • Display 7 Segment LED Display Tank material SS 304 • Outer body SS 304 • Electrical Requirements 9 A • Power Consumption 1600 W • Calibration certificate from NABL Lab Make: Borosil, Memmert, Thermofischer, GLASSCO Please Enable Macros to View BoQ information |