| 1 | Providing and laying boulder apron for bed protection with stone boulders of minimum size and weight as per Table 1300.1, no fragment weighing less than 25 kg laid dry complete as per drawing and technical specifications Clause 1301 |
| 2 | White washing with lime to give an even shade :13.37.1 New work (three or more coats) |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. |
| 4 | Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. |
| 5 | Providing barricading 2 Nos. ROWS ballies with 4-5\\" dia khooteys & Horizontal ballies 2.3-3.5 dia horizontal khooteys tied 8' c/c with nails and Nariyal rope i/c khooteys 2-2.5' under GL on Hire basis complete for the followings |
| 6 | Swiss cottage 3 Room Double fly 12'x12' or 6'x12'. |
| 7 | E.P. Tent double fly with kental on ballies frame 18x18' or 16'x20'. |
| 8 | Store Tent double fly with kanat on ballies frame 18'x48'. |
| 9 | Choldary single fly 14'x14'. |
| 10 | Almirah Steel Big Size |
| 11 | Almirah Steel Small Size |
| 12 | Bed nylon niwar 6'x3' of sheet frame |
| 13 | Bed sheet coloured double size |
| 14 | Bed sheet coloured single size |
| 15 | Moulded chair plastic |
| 16 | Bucket Plastic |
| 17 | Central table sunmica top 2'x4' size |
| 18 | Chair Un-armed wooden/ Steel |
| 19 | Chair with dunlop seat with steel frame and handle |
| 20 | Non woolen carpet |
| 21 | Dari size 10'x8' |
| 22 | Double Bed sunmica top + 2 dunlope mattress 3\\" |
| 23 | Dressing table with stool |
| 24 | Foot mate |
| 25 | Pillow cotton with with cover |
| 26 | Razai plain with cover |
| 27 | Secretarial table with one draws sunmica top 4'x3' |
| 28 | Sofa set 3 seat paded spring, cloth cover |
| 29 | Table cloth |
| 30 | Table folding wooden |
| 31 | Takhat wooden fix type |
| 32 | Steel frame bench |
| 33 | Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with areanot exceeding 0.9 sqm supported on RCC Post 100 mm x 100 mm firmly fixed to the ground by means of properly designed foundation with M-15grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701 |
| 34 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 35 | Finishing walls with water proofing cement paint of required shade : 13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 36 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m inwidth or 10 sqm on plan), including dressing of sides and ramming ofbottoms, lift upto 1.5 m, including getting out the excavated soil anddisposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 All kinds of soil. |
| 37 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel :4.1.10 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stoneaggregate 40 mm nominal size) |
| 38 | Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing andreinforcement - All work up to plinth level :5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stoneaggregate 20 mm nominal size) |
| 39 | Brick work with common burnt clay FP.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 40 | 5.3 Reinforced cement concrete work in beams, suspended floors, roofs havingslope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plainwindow sills, staircases and spiral stair cases above plinth level up tofloor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarsesand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 41 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of thesheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm)with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 42 | Centering and shuttering including strutting, propping etc. and removalof form for :5.9.5 Lintels, beams, plinth beams, girders, bressumers andcantilevers |
| 43 | Centering and shuttering including strutting, propping etc. and removalof form for : Suspended floors, roofs, landings, balconies and accessplatform |
| 44 | Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in superstructure above plinth level up to floor V level inall shapes and sizes in :6.4.2 Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 45 | Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 7.5 in superstructure above plinth level up to floorV level.6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand) |
| 46 | Providing and fixing pressed steel door frames conforming to IS: 4351,manufactured from commercial mild steel sheet of 1.60 mm thickness,including hinges, jamb, lock jamb, bead and if required angle thresholdof mild steel angle of section 50x25 mm, or base ties of 1.60 mm,pressed mild steel welded or rigidly fixed together by mechanical means,including M.S. pressed butt hinges 2.5 mm thick with mortar guards,lock strike-plate and shock absorbers as specified and applying a coatof approved steel primer after pre-treatment of the surface as directedby Engineer-in-charge:10.14.1.1 Fixing with adjustable lugs with split end tail toeach jamb |
| 47 | Providing and laying cement concrete in retaining walls, return walls,walls (any thickness) including attached pilasters, columns, piers,abutments, pillars, posts, struts, buttresses, string or lacing courses,parapets, coping, bed blocks, anchor blocks, plain window sills, fillets,sunken floor etc., up to floor five level, excluding the cost of centering,shuttering and finishing:4.2.3 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stoneaggregate 20 mm nominal size) |
| 48 | Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steelprimer using structural steel etc. as required.10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gatesand similar works |
| 49 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) decorative type, core of block board construction withframe of 1st class hard wood and well matched teak 3 ply veneeringwith vertical grains or cross bands and face veneers on both faces ofshutters9.20.2 30 mm thick including ISI marked Stainless Steel butt hingeswith necessary screws |
| 50 | Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with :10.30.1 4.0 mm thick glass panes |
| 51 | 12 mm cement plaster of mix :13.1.2 1:6 (1 cement: 6 fine sand) |
| 52 | 15 mm cement plaster on the rough side of single or half brick wall ofmix :13.2.2 1:6 (1 cement: 6 fine sand) |
| 53 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification. 13.42.1 Two or more coats on new work |
| 54 | 13.46 Finishing walls with Acrylic Smooth exterior paint of required shade :13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqmover and including priming coat of exterior primer applied@ 2.20 kg/10 sqm) |
| 55 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :13.48.3 Painting Steel work with Deluxe Multi Surface Paint togive an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 56 | Providing and fixing Ist quality ceramic glazed wall tiles conforming toIS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black ofany size as approved by Engineer-in-Charge, in skirting, risers of stepsand dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shadecomplete. |
| 57 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conformingto IS : 15622 of approved make in colours such as White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm includingpointing the joints with white cement and matching pigment etc.,complete |
| 58 | Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlleddevice (handle lever) conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls andfloors wherever required:17.1.1 White Vitreous china Orissa pattern W.C. pan of size580x440 mm with integral type foot rests |
| 59 | Providing and fixing white vitreous china pedestal type water closet(European type W.C. pan) with seat and lid, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlleddevice (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls andfloors wherever required :17.2.1 W.C. pan with ISI marked white solid plastic seat and lid |
| 60 | 17.5 Providing and fixing white vitreous china flat back half stall urinal ofsize 580x380x350 mm with white PVC automatic flushing cistern,with fittings, standard size C.P. brass flush pipe, spreaders withunions and clamps (all in C.P. brass) with waste fitting as per IS :2556, C.I. trap with outlet grating and other couplings in C.P. brass,including painting of fittings and cutting and making good the wallsand floors wherever required :17.5.1 Single half stall urinal with 5 litre P.V.C. automatic flushingcistern |
| 61 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brasspillar taps, 32 mm C.P. brass waste of standard pattern, includingpainting of fittings and brackets, cutting and making good the wallswherever require:17.7.1 White Vitreous China Wash basin size 630x450 mm witha pair of 15 mm C.P. brass pillar taps |
| 62 | 17.8 Providing and fixing white vitreous china pedestal for wash basincompletely recessed at the back for the reception of pipes and fittings. |
| 63 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps,i/c making good the walls etc. concealed pipe, including paintingwith anti corrosive bitumastic paint, cutting chases and making goodthe wall :18.11.1 15 mm dia nominal bore |
| 64 | 18.49 Providing and fixing C.P. brass bib cock of approved quality conformingto IS:8931 :18.49.1 15 mm nominal bore |
| 65 | Providing and fixing ball valve (brass) of approved quality, High or lowpressure, with plastic floats complete :18.18.1 15 mm nominal bore |
| 66 | Providing and fixing uplasticised PVC connection pipe with brassunions :18.21.2 45 cm length18.21.2.1 15 mm nominal bore |
| 67 | 18.53 Providing and fixing C.P. brass angle valve for basin mixer and geyserpoints of approved quality conforming to IS:8931 |
| 68 | Providing and fixing PTMT towel rail complete with brackets fixed towooden cleats with CP brass screws with concealed fittingsarrangement of approved quality and colour17.73.2 600 mm long towel rail with total length of 645 mm, width78 mm and effective height of 88 mm, weighing not lessthan 190 gms. |
| 69 | Providing and fixing on wall face unplasticised Rigid PVC rain waterpipes conforming to IS : 13592 Type A, including jointing with sealring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.12.41.1 75 mm diameter |
| 70 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 71 | 18.48 Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, IS : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank. |
| 72 | Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in foundation and plinth in:6.1.2 Cement mortar 1:4 (1 cement : 6 coarse sand) |
| 73 | 20 mm cement plaster :13.3.1 1:4 (1 cement : 4 fine sand) |
| 74 | 5.22 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. Please Enable Macros to View BoQ information |