| 1 | NOTE:-(i) The bidders/contractors are advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates.(ii) It is highlighted that the certain condition of General Condition of Contracts (IAFW-2249) has been modified as per direction of MoD i.e. inclusssion of Performance Security, deletion of Risk & Cost Provisions and increase in defect liability period all as per tender documents. The tenderers should keep in mind while quoting their offer. (iii) (Applicable for all items/parts):- The bidders/contractors are advised to refer Notes on BOQ/SCH'A' before entry/quoting the rates. |
| 2 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. |
| 3 | Material and labour for (concealed Type) point wiring including necessary chase cutting of wall for one light/fan/call bell point with 1.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC conduit medium grade with all accessories and sunk modular GI box for mounting of fittings like switch, socket and fan regulator and making good the disturbed surfaces as per the existing complete all as specified and as directed by the Engr-in-Charge.Note:- A. Red colored cable shall be used for live connection; black colored cable shall be used for neutral connection and green colored cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.B. The Rate of point wiring includes the following: - (i) Copper standard wire. (ii) PVC conduit with accessories. (iii) Chase cutting. |
| 4 | . -Ditto- all as per item No 2.00 here-in-before but for 3 pin 6 amps switch socket combination on the same board with 1.5 Sqmm cable and -ditto-. |
| 5 | . -Ditto- all as per item No 2.00 here-in-before but for 3 pin 6 amps switch socket combination on the independent board with 1.5 Sqmm cable and -ditto-. |
| 6 | .-Ditto- all as per item No 2.00 here-in-before but for one light point control by 2 way switch on the independent board with 1.5 Sqmm cable and -ditto-. |
| 7 | . -Ditto- all as per item No 2.00 here-in-before but for one 6 pin multi, Modular socket outlet, 6/16 Amps, independent, with single core multi strand insulated unsheathed copper conductor 4.00 Sqmm FRLSH of size including single core multi strand unsheathed copper conductor 4.00 Sqmm FRLSH for earth continuity and connecting to common earth dolly and -ditto-. |
| 8 | . -Ditto- all as per item No 2.00 here-in-before but for one 6 pin multi, Modular socket outlet, 6/16 Amps, independent, with single core multi strand insulated unsheathed copper conductor 2.50 Sqmm FRLSH of size including single core multi strand unsheathed copper conductor 2.50 Sqmm FRLSH for earth continuity and connecting to common earth dolly and -ditto-. |
| 9 | Material and labour for point wiring (surface type) for one light/fan/call bell point with 1.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC casing caping with all accessories and PVC rectangular boxes for mounting switch socket and fan regulator etc complete all as specified and as directed. Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. |
| 10 | . -Ditto- all as per item No 8.00 here-in-before but for 3 pin 6 amps switch socket combination on the same board with 1.5 Sqmm cable and -ditto-. |
| 11 | . -Ditto- all as per item No 8.00 here-in-before but for 3 pin 6 amps switch socket combination on the independent board with 1.5 Sqmm cable and -ditto-. |
| 12 | .-Ditto- all as per item No 8.00 here-in-before but for one light point control by 2 way switch on the independent board with 1.5 Sqmm cable and -ditto-. |
| 13 | . -Ditto- all as per item No 8.00 here-in-before but for one 6 pin multi, Modular socket outlet, 6/16 Amps, independent, with single core multi strand insulated unsheathed copper conductor 4.00 Sqmm FRLSH of size including single core multi strand unsheathed copper conductor 4.00 Sqmm FRLSH for earth continuity and connecting to common earth dolly and -ditto-. |
| 14 | . -Ditto- all as per item No 8.00 here-in-before but for one 6 pin multi, Modular socket outlet, 6/16 Amps, independent, with single core multi strand insulated unsheathed copper conductor 2.50 Sqmm FRLSH of size including single core multi strand unsheathed copper conductor 2.50 Sqmm FRLSH for earth continuity and connecting to common earth dolly and -ditto-. |
| 15 | Supply and fixing sub-main wiring with PVC insulated & unsheathed two run of 6.00 Sqmm single core multi stranded copper conductor cable (FRLSH), 1100 Volt grade alongwith one run of 6.00 Sqmm PVC insulated & unsheathed copper conductor cable (FRLSH), 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through 20 mm conduit/ Casing Caping with all accessories and PVC rectangular boxes for mounting switch socket and fan regulator etc including taking down old sub-main wiring complete all as specified and as directed.Note : Three runs of 6.00 Sqmm cable and conduit shall be measured as one unit. |
| 16 | Supply and fixing sub-main wiring with PVC insulated & unsheathed two run of 4.00 Sqmm single core multi stranded copper conductor cable (FRLSH), 1100 Volt grade alongwith one run of 4.00 Sqmm PVC insulated & unsheathed copper conductor cable (FRLSH), 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through 20 mm conduit/ Casing Caping with all accessories and PVC rectangular boxes for mounting switch socket and fan regulator etc including taking down old sub-main wiring complete all as specified and as directed.Note : Three runs of 4.00 Sqmm cable and conduit shall be measured as one unit. |
| 17 | Supply and fixing sub-main wiring with PVC insulated & unsheathed two run of 2.50 Sqmm single core multi stranded copper conductor cable (FRLSH), 1100 Volt grade alongwith one run of 2.50 Sqmm PVC insulated & unsheathed copper conductor cable (FRLSH), 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through 20 mm conduit/ Casing Caping with all accessories and PVC rectangular boxes for mounting switch socket and fan regulator etc including taking down old sub-main wiring complete all as specified and as directed.Note : Three runs of 2.50 Sqmm cable and conduit shall be measured as one unit. |
| 18 | Material & labour for cutting chases for sub-main concealed wiring, cutting not exceeding 10cm girth and make the surface good as per existing with cement morter 1:3 complete all as specified and as directed. |
| 19 | Supply and fixing as in replacement Piano switch flush button single pole one way 5/6 Amps, 240 volt complete all as specified and as directed. |
| 20 | Supply and fixing as in replacement Piano switch flush button single pole two way 5/6 Amps, 240 volt complete all as specified and as directed. |
| 21 | Supply and fixing as in replacement bell push 6 amps 240 volt single pole flush type complete all as specified and as directed. |
| 22 | Supply and fixing as in replacement socket outlet 5 pin, 6 Amps, 230 volt flush type complete all as specified and as directed. |
| 23 | Supply and fixing as in replacement switch socket combination 5 pin, 6 Amps, 230 volt flush type complete all as specified and as directed. |
| 24 | Supply and fixing as in replacement switch socket combination multipurpose 2 in 1, 5 pin 6/16 amps 230 volt flush type complete all as specified and as directed. |
| 25 | Supply and fixing as in replacement Buzzer, Ding Dong AC. 230 volts, single pole complete all as specified and as directed. |
| 26 | Supply and fixing as in replacement lamp holder, PVC/ polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed. |
| 27 | Supply and fixing as in replacement step type electronic fan regulator 100/120 watt flush type AC 220 Volt complete all as specified and as directed. |
| 28 | Supply and fixing as in replacement Metal flush box modular for 1/2 module complete all as specified and as directed. |
| 29 | Supply and fixing as in replacement Metal flush box modular for 3 module complete all as specified and as directed. |
| 30 | Supply and fixing as in replacement Metal flush box modular for 4 module complete all as specified and as directed. |
| 31 | Supply and fixing as in replacement Metal flush box modular for 6 module complete all as specified and as directed. |
| 32 | Supply and fixing as in replacement Metal flush box modular for 8 module complete all as specified and as directed. |
| 33 | Supply and fixing as in replacement White cover plate with frame (both inner plate & outer plate cover),modular for 1/2 module complete all as specified and as directed. |
| 34 | Supply and fixing as in replacement White cover plate with frame (both inner plate & outer plate cover),modular for 3 module complete all as specified and as directed. |
| 35 | Supply and fixing as in replacement White cover plate with frame (both inner plate & outer plate cover),modular for 4 module complete all as specified and as directed. |
| 36 | Supply and fixing as in replacement White cover plate with frame (both inner plate & outer plate cover),modular for 6 module complete all as specified and as directed. |
| 37 | Supply and fixing as in replacement White cover plate with frame (both inner plate & outer plate cover),modular for 8 module complete all as specified and as directed. |
| 38 | Supply and fixing as in replacement Modular switch single pole one way 6 Amps, 230 volt, 1 Module complete all as specified and as directed. |
| 39 | Supply and fixing as in replacement Modular switch Two way 6 Amps, 230 volt, 1 Module complete all as specified and as directed. |
| 40 | Supply and fixing as in replacement Modular switch single pole one way 16 Amps, 230 volt, 1 Module complete all as specified and as directed. |
| 41 | Supply and fixing as in replacement Modular type bell push 10 amps 230 volt, 1 Module complete all as specified and as directed. |
| 42 | Supply and fixing as in replacement Modular type 5 step fan regulator 120 watt step type, AC 220 Volt, 2 Module complete all as specified and as directed. |
| 43 | Supply and fixing as in replacement Modular type shuttered socket outlet 2/3 pin, 6 Amps, 230 volt, 2 Module complete all as specified and as directed. |
| 44 | Supply and fixing as in replacement Modular type shuttered socket outlet 2/3 pin, 6/16 Amps, 230 volt, 2 Module complete all as specified and as directed. |
| 45 | Supply and fixing as in replacement Modular type starter 25 Amps, 2 Module suitable for AC/Geyser point complete all as specified and as directed. |
| 46 | Supply and fixing as in replacement Modular electronic fan regulator step type, 2 Module 100/120 watt flush type AC 220 Volt complete all as specified and as directed. |
| 47 | Supply and fixing as in replacement ceiling rose surface Bakelite three terminal complete all as specified and as directed. |
| 48 | Supply and fixing as in replacement metal clad industrial plug of 20 amps rating 220-250 volt, complete all as specified and directed. |
| 49 | Supply and fixing as in replacement metal clad industrial socket of 20 amps rating 220-250 volt, complete all as specified and directed. |
| 50 | Supply and fixing as in replacement plug top 3 pin15 Amps, complete all as specified and directed. |
| 51 | Supply and fixing as in replacement 1 X 12Watt, 230V LED Lamp with B-22 base, AC 230 Volt, 50HZ, 6500K suitable for holder fittings complete all as specified and as directed. |
| 52 | Supply and fixing as in replacement 1 X 12Watt, 230V LED Lamp with B-22 base, AC 230 Volt, 50HZ, 6500K inverter type suitable for holder fittings complete all as specified and as directed. |
| 53 | Supply and fixing as in replacement MCB DB TPN (VTPN) 4 ways double door with MCCB TPN incommer including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and as directed.Note:- MCCB, MCB SPN and MCB SP shall be measured and paid seperately under respective item. |
| 54 | Supply and fixing as in replacement MCB DB TPN 4 ways double door with MCB TPN incommer including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and as directed.Note:- MCB TPN, MCB SPN and MCB SP shall be measured and paid seperately under respective item. |
| 55 | Supply and fixing as in replacement MCB DB SPN 8 ways double door including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and as directed.Note:- MCB SPN and MCB SP shall be measured and paid seperately under respective item. |
| 56 | Supply and fixing as in replacement MCB DB SPN 4 ways double door including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and as directed.Note:- MCB SPN and MCB SP shall be measured and paid seperately under respective item. |
| 57 | Supply and fixing as in replacement sheet metal enclosure single pole and neutral with two pin & earth plug with socket complete with one single pole MCB 20 Amps, DP, 240 Volts `C’ series complete all as specified and as directed. |
| 58 | Supply and fixing as in replacement on-load change over switch 04 pole of capacity 100Amps - 415 Volts with SS enclosure complete all as specified and as directed. |
| 59 | Supply and fixing as in replacement MCCB triple pole and neutral (Four pole) 63 Amp, 415 volts, 50 Hz, having thermal setting range 70% to 100% and fixed magnetic setting and breaking capacity 25 KA including making incoming and outgoing connections complete all as specified and as directed. |
| 60 | Supply and fixing as in replacement MCCB triple pole and neutral (Four pole) 160 Amp, 415 volts, 50 Hz, having thermal setting range 70% to 100% and fixed magnetic setting and breaking capacity 16 KA including making incoming and outgoing connections complete all as specified and as directed. |
| 61 | Supply and fixing as in replacement MCB TPN, 240 Volts, of 63 amps current rating, 10 KA breaking capacity ‘C' series complete all as specified and as directed. |
| 62 | Supply and fixing as in replacement MCB SPN, 240 Volts, of 40 amps current rating, 10 KA breaking capacity ‘C' series complete all as specified and as directed. |
| 63 | Supply and fixing as in replacement MCB SP, 240 Volts, of 6-32 amps current rating, 10 KA breaking capacity ‘C' series complete all as specified and as directed. |
| 64 | Supply and fixing as in replacement Slim, compact, aluminum die cast edge lit panel, recessed mounted square type fixture 18 Watt, 6500 K with opal diffuser and separate electronic driver for ceiling complete all as specified and as directed. |
| 65 | Supply and fixing as in replacement Slim, compact, aluminum die cast edge lit panel, recessed mounted round type fixture 18 Watt, 6500 K with opal diffuser and separate electronic driver for ceiling complete all as specified and as directed. |
| 66 | Supply and fixing as in replacement Energy efficient tube light fitting with LED batten type luminaire 10W, 230V, with system lumen efficacy >120 lumen per watt extruded aluminium housing and integrated electronic driver with completely pre-wired with copper flexible wire and decorative caps with connector block, etc with all accessories screws, gutties etc. complete all as specified and as directed. |
| 67 | Supply and fixing as in replacement Energy efficient tube light fitting with LED batten type luminaire 20W, 230V, with system lumen efficacy >120 lumen per watt extruded aluminium housing and integrated electronic driver with completely pre-wired with copper flexible wire and decorative caps with connector block, etc with all accessories screws, gutties etc. complete all as specified and as directed. |
| 68 | Supply and fixing as in replacement Indoor LED recessed mounted luminaire 36 Watt 2 ft × 2 ft comprising of white powder coated CRCA housing with high translucent frosted diffuser and driver inbuilt 4KV surge protection, operating voltage range 140 to 240 V AC, CCT 5700K, Power factor 0.95, CRI >80 and system efficacy >110 lumen per watt complete with all accessories prewired wire for connection, making good the disturbed ceiling and complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 69 | Supply and fixing as in replacement Indoor LED recessed mounted luminaire 36 Watt 2 ft × 2 ft comprising of white powder coated CRCA housing with high translucent frosted diffuser and driver inbuilt 4KV surge protection, operating voltage range 140 to 240 V AC, CCT 5700K, Power factor 0.95, CRI >80 and system efficacy >110 lumen per watt complete with all accessories prewired wire for connection, making good the disturbed ceiling and complete all as specified and as directed. Please Enable Macros to View BoQ information |