| 1 | Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling, ramming the foudation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/l. B.C.D 5.1.01 |
| 2 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including' cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement complacted volume). B.C.D (5.1.10) |
| 3 | Earth filling in foundation trenches and plinth in layers not exceeding 150 mm. thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation frenches within a lead of 50 M. and lift of 1.5 M all complete as per building specification and direction of E/l (Mode of measurement compacted volume).B.C.D (5.1.7) |
| 4 | Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. B.C.D (5.6.3) |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)B.C.D (5.3.1.4) |
| 6 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) B.C.D (5.3.9.1) |
| 7 | Providing designation 75 B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l.B.C.D (5.2.6) |
| 8 | Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x3\\") in C.M. (1:6) in foundation and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. B.C.D (5.2.52) |
| 9 | Providing designation 112mm thick reinforcement designtion 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x3\\") in C.M. (1:4) in supertructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including cost of screening materials scaffoliding raking out joints to 15mm depth curing taxesand royalty ( but excluding theb cost of reinforcement) all complete as per building specification and direction of E/I. B.C.D (5.2.54) |
| 10 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). B.C.D (5.3.11) |
| 11 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size). B.C.D (5.3.10) |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete B.C.D (5.3.17.1) |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers B.C.D (5.3.17.5) |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for Shelves (Cast in situ) B.C.D (5.3.17.4) |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts B.C.D (5.3.17.6) |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform B.C.D (5.3.17.3) |
| 17 | Providing and fixing fan hook of 16mm dia. M.S.bar and 1m long,bend to required size and shape, placed in position and fixed in R.C.C. Beam/Slab at the time of casting all complete as per specification and direction of E/I B.C.D (5.5.13) |
| 18 | Supplying, fitting and fixing 200x20x6mm. L-type M.S. clamp properly fishtailed, including making holes and setting the same in 250x125x75mm cement concrete block (1:2:4 )with cost of all labour and materials and taxes as per building specification and direction of E/l. B.C.D (5.5.9) |
| 19 | Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth , carriage of grill to work site, hoisting as per building specification and direction of E/l. (where materials is not supplied by the deptt.) B.C.D (5.5.12) |
| 20 | Supplying, fitting and fixing callapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2 mm at 100mm. centres and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40x40x6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangements, stoppers, handles, including applying a priming coat of red lead paint, carriage , hoisting and taxes all complete as per building specification and direction of E/l. B.C.D (5.5.14) |
| 21 | Supplying, fitting and fixing 20 guage G.C.I, sheet gate fitted on M.S. Angle frame of size 60x60x6mm. including cost of fabrication , providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/l. B.C.D (5.5.29) |
| 22 | Providing 25 mm thick first class patent stone flooring (1:2:4) with stone chips in two layers, bottom layer 19 mm thick (1:2:4) with 12 mm to 6mm size graded stone chips and top layer 6 mm thick (1:2) with 6mm down stone chips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royalty with all complete as per building specification and direction of E/l. B.C.D (5.6.7) |
| 23 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. B.C.D (5.7.3) |
| 24 | Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. B.C.D (5.7.1) |
| 25 | Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/l B.C.D (5.7.11) |
| 26 | Providing 19 mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. B.C.D (5.7.15) |
| 27 | Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. B.C.D (5.7.6) |
| 28 | Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direciton of E/l. B.C.D (5.8.45) |
| 29 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 90 kg/10 sqm). (DSR 13.46.1) |
| 30 | Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding, washing of floors and taxes all complete as per building specification and direction of E/l. B.C.D (5.8.18) |
| 31 | Providing Tor steel reinforcement of 8mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. TMT Fe 500 (Only Valid for SAIL & TATA Steel, JSPL ,Electro Steel Ltd. and Vizal Steel) (i) 8mm dia rods. B.C.D (5.5.4) |
| 32 | Providing Tor steel reinforcement of 10mm. ,12mm & 16mm dia. bars as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (a) 10mm (TMT,Coil Fe 500) (Only Valid for SAIL & TATA Steel, JSPL ,Electro Steel Ltd. and Vizal Steel). B.C.D (5.5.5) |
| 33 | Providing Tor steel reinforcement of 10mm. ,12mm & 16mm dia. bars as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (a) 12mm (TMT,Coil Fe 500) (Only Valid for SAIL & TATA Steel, JSPL ,Electro Steel Ltd. and Vizal Steel) B.C.D (5.5.6) |
| 34 | Earth work in excavation in foundation trenches in Hard soil ( vide classification of soil item A & B) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. B.C.D (5.1.1+ 5.1.2) |
| 35 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size). B.C.D (5.3.1.2) |
| 36 | Providing designation 125mm thick reinforcement designtion 75 A brick work in C.M. (1:4) in supertructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including cost of screening materials scaffoliding raking out joints to 15mm depth curing taxesand royalty ( but excluding theb cost of reinforcement) all complete as per building specification and direction of E/I. B.C.D (5.2.23) |
| 37 | Supplying, fitting and fixing vitreous white glazed earthen ware I.W.C. Of parry Hindustan or any other I.S.S. Approved make with 100mm H.C.I. 'P' trap 15liters C.I. Pull and let go flushing cistern of names or other I.S.S. Equipment make, complete with all fittings, C.I. or C.C. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pert of vitreous white glazed earthenwere were footrest to be fixed in floor 15mm C.I. body brass spindle stope cock of weight not less than 50grms, 15mm P.V.C. connection pipe 450mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/I.580 mm long with 12.5 lit. Low level PVC Cistern. (DWSD 3.2.1) |
| 38 | Supply of Bricks Bats at kilen site to the work site as per direction of E.I. Complete job. |
| 39 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,Single socketed pipes. 110 mm diameter .(DSR 12.41.1) |
| 40 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with piano type switch phenolic laminated sheet, suitable size PVC / GI box etc. as required. Group C(1.1.3) Electric |
| 41 | I.T.C. of ceiling fan incluing wiring the down rods of standard length (Up to 30 cm) with 1.5 sq. mm FRPVC with 1.5 sq.mm FRPVC insulated copper conductor single core cable etc. as reqd. (1.44) Electric |
| 42 | Supply of Ceiling Fan 48\\" (1200 mm) as required to work site as per E.I. (M-772) Electric |
| 43 | S/F Brass batton / angle Holder including connection etc. as reqd. (1.34) Electric |
| 44 | Supply of 15/16 watt L.E.D Bulb to work site as per dierction E.I. (M-856) Electric |
| 45 | S/F 2 pin 5 amp ceiling rose on the exising juntion box wooden block including connection etc. as reqd. (1.33) Electric |
| 46 | Supplying and fixing folloing Piano type switch / Socket on the existing switch box/cover including connection etc. as reqd. (i) 5/6 amps ,one way switch. (1.23.1) Electric |
| 47 | Supplying and fixing folloing Piano type switch / Socket on the existing switch box/cover including connection etc. as reqd.(i) 3 Pin 5/6 amps, socket outlet. (1.23.4) Electric |
| 48 | Supplying and fixing PVC/GI box of following size on surface or in recess with suitable size of phenolic laminated sheet cover infront including painting etc. as required. (i)147 mm x 93 mm x 47 mm deep / (5\\" x 7\\"). (1.22.3) Electric |
| 49 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.(i) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire. (1.7.1) Electric |
| 50 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.(ii) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. (1.7.2) Electric |
| 51 | Add Carriage Cost Materials Brick |
| 52 | Stone Chips |
| 53 | Stone metal |
| 54 | GST 18% |
| 55 | Labour Cess 1% Please Enable Macros to View BoQ information |