| 1 | Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with Single arm bracket 1 Mtr length in 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling and Required T&P completee in all respect. (PS No. 641).(Make - Bajaj/Valmont/Transrail) |
| 2 | Supply , Installation , testing and commissioning of standard 4.0 Mtr. High (above ground) hot dip galvanized (grading of galvenisation average 70 micron or better as per IS 2629 or equivalent) pole, with stiffener, chain, allen bolt, foundation, single arm bracket, template, nut and bolts galvanized, factory finish base plate of size 200x200x12mm etc complete as required. The pole shall be made of 3mm thickness sheet with tolerance of +/- 5%. The column shall also be provided with flush door at the bottom with proper strengthening to the cutout of the door opening, a junction/loop box with heavy duty 3 phase , 32 Amp. connector with 16A DP MCB including all accessories complete as required derected by E/I.(Make - Bajaj/Valmont/Transrail) |
| 3 | Supply and Fixing of LED Street Light fitting having die cast Aluminium body and difuser with driver set suitable for 75 to 90 watt. Confirming to IP-66 and above protection. Complete in all respects. (PS No. 1422) Cat-AAA (Make - LT/Bajaj/Havells/ Crompton/Philips/Wipro) |
| 4 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in existing surface / recessed steel / PVC conduit as required 3x1.5sq.mm DSR2018 Item .no.1.17.3 |
| 5 | Supply of PCC Pole 8.5 Mtrs as per UPERC-2019/I. No. 1 page 48 |
| 6 | S/F of 1100 Voltage grade aerial bunched cable, Power cable: Standard compacted circular aluminium conductor, XLPE insulator Messenger conductor, standard compacted circular all aluminium alloy bare conductor, 3 power core laid around messenger conductor 1cX16 sqmm lighting core aluminium conductor and XLPE insulated of size 3 core x 120 sqmm + 1Cx95 sqmm + 1cx16sqmm. Complete in all recpects as per direction of E/I. (AOR) |
| 7 | Supply and fixing of XLPE insulated Al. unarmoured cable for working voltage for energizing the distribution boxes & street light size 1x16sqmm complete in all respects as per direction of E/I. (AOR) |
| 8 | Supply and fixing of XLPE insulated Al. unarmoured cable for working voltage for energizing the distribution boxes & street light size 1x35sqmm complete in all respects as per direction of E/I. (AOR) |
| 9 | Supplying and laying of aluminium conductor PVC insulated armoured, served, sheathed cable 1100 Volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm. thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. Clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respects. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. (Polycab, KEI, Havell's make) |
| 10 | (1)16 Sq.mm. 4Core (PS No. 501) |
| 11 | (2) 50 sq mm 3 ½” core (PS No. 501) |
| 12 | S/F of Palm or Pin type copper tin plated cable socket (lugs) to the cable lead insulation with tape and making connections complete as per direction of E/I. P.S. No. 504 |
| 13 | 1- 16 Sq.mm. |
| 14 | 2- 25 Sq.mm. |
| 15 | 3- 50 Sq.mm. |
| 16 | S/Laying of 51 mm dia (OD 63 mm & ID 51 mm nominal) size of (DWC) HDPE Pipes ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part-II complete with filling and cutting, jointing etc. direct in ground ( 75 cm below ground level) including excavation and refilling the trench pat excluding sand cushioning and protective covering etc. Complete in all respects. Rex/Duraline/ Time/CPE make. as per DSR 2018 item no. 14.16.2 page no. 49 |
| 17 | S/Laying of 90 mm dia (OD 90 mm & ID 76 mm nominal) size of (DWC) HDPE Pipes ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part-II complete with filling and cutting, jointing etc. direct in ground ( 75 cm below ground level) including excavation and refilling the trench pat excluding sand cushioning and protective covering etc. Complete in all respects. Rex/Duraline/ Time/CPE make. as per DSR 2018 item no. 14.16.2 page no. 49 |
| 18 | Supply and fixing of 25 Amp TPN capacity of automatic street light cubical control panel painted with anti corrosive alkali and acid proof paint crossing of time switch TSO 100 series with contractors, HRC fuse, isolating swtich metering instrument & instrument box with CTs etc. in case of TPN, Complete in all respects. as per PS No. 807C |
| 19 | Supply and fixing of 40 Amp TPN capacity of automatic street light cubical control panel painted with anti corrosive alkali and acid proof paint crossing of time switch TSO 100 series with contractors, HRC fuse, isolating swtich metering instrument & instrument box with CTs etc. in case of TPN, Complete in all respects. as per PS No. 807F |
| 20 | Supply and buring of safe earthing electrode T-19 (Hot dip galvanized), length up to 3000mm outer type 50mm, inner pipe, 25mm terminal dia 12mm, outer GI pipe of 16 SWG and inner GI pipe of 12 SWG with Hot Dip galvanization up to 100 micron filled with crystalline conductive mixture(CCM) having anti corrosive & conductive property with 50 Kgs activated soil (BFC) capable of reducing the soil resistivity with good micture of retaining capicity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25x3 G.I. strip will be extra as per PS No. 725B |
| 21 | Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I . strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified.(P.S. No 725A) |
| 22 | Demolishing cement concrete manually/by mechanical means including disposal of material with in 50 mtr lead as per direction of E/I nominal concrete 1:3:6 or richer mix ( i/cequivalent design mix) AOR |
| 23 | Providing and laying in position cement concrete 1:3:6 (1 cement : 3 coarse sand : graded stone aggretage 40 mm nominal size) in foundation of pump, DG Set etc. including form work etc as required DSR Civil 2018/I No. 14.9 P-48) |
| 24 | Dismantling of pole/street Lightr standard / strut embedded in cement concrete foundation etc. as per required (DSR -2018/Item No. 12.42 P-46) |
| 25 | Dismantling of 16 Mtr Height High Mast with the help of Crane/Hydra and required labour T&P etc. Complete in all respect . As per direction of E/I. |
| 26 | Fixing of 16 Mtr Height High Mast with the help of Crane/Hydra and required labour T&P etc. on existing foundation. Complete in all respect . As per direction of E/I. |
| 27 | Supply of Sheet Moulded Compound and Thermoplatic LT Distribution box of size 450x350x200mm, for 3 Phase Out door connection to LT Line consumers through overhead ABC Line, Shockproof, rust proof, termite proof, vermin proof, self extinguished, Complete with provision of 3 phase aluminium bus bars of EC grade of size 25x6x300mm long and neutral bus bar of size 40x6x300mm. It will be with coloured sleeves on each busbar, the same will be with facility of cable termination having i incoming and 4 outgoing with 4 polymeric glands of 25mm dia and 6 Nos rubber gurmuts on each side. (AOR) |
| 28 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. DSR Electrical 2018/ I.No. 12.34 Please Enable Macros to View BoQ information |