| 1 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, culverts,etc, but excluding ashlar facings, dressed stonework and precast concrete articles etc complete all as specified and as directed . |
| 2 | Brickwork with sub class ‘B’ (old size) bricks, straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:6 complete all as specified and as directed. |
| 3 | Ditto all as per Srl item No. 2 here-in-before, but except Bricks. |
| 4 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying under ground cable, erection of poles etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out etc in any type of soil, complete all as specified and directed. |
| 5 | PCC 1:2:4 type B-0 (Using 12.5mm graded crushed stone aggregates) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles including necessary form work complete all as specified and directed. |
| 6 | Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar of 150 mm diameter incl bends, complete all as specified and directed. |
| 7 | Concrete bed to drain pipes 1:3:6 type C-2 (Using 40mm graded crushed stone aggregate) including packing under and haunching against the side of pipes after they are laid and tested for 150mm internal dia of pipe, complete all as specified and directed. |
| 8 | RCC class NP3 150mm dia drain pipes laid in trenches and jointed with & including collar complete all as specified and directed. |
| 9 | Supply only liquid water proofing compound compound all as specified and as directed. |
| 10 | Plain Cement Concrete (1:2:4) type B-1 (using 20 mm graded crushed stone aggregates) as in coping of poles etc including weathring, slightly rounded or chamfered angle and throating, necessary form work finishing all exposed faces of concrete etc complete all as specified and directed. |
| 11 | Dismantling wrought iron or mild steel work of any description complete all as specified and directed. |
| 12 | Mild steel framed work as in grills,gratings ladders etc with ends of bar shouldered and/or riveted or welded or forged into spikes,framed guard bars,ladders,framework for water tanks and similar work conforming to Fe-290,grade E-165, complete all as specified. |
| 13 | Demolition of cement concrete reinforced (reinforcement cut as required to facilitate demoltion complete all as specified and directed. |
| 14 | Precast cement concrete (1:2:4) type B-1 (using 20 mm graded crushed stone aggregates) as in bonders for stone walling set in cement mortar 1:6 including use and waste of necessary formwork, complete all as specified and directed. |
| 15 | TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia complete all as specified and as directed. |
| 16 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specified and directed. |
| 17 | Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 18 | Construction of Septic tanks including excavation in any type soil, foundation in PCC 1:2:4, brick work in CM 1:4, RCC Slab in M-25 Design mix including RCC precast manhole cover with angle iron frame Vent shaft and sludge chambers etc., complete for 25 users, complete all as specified and shown on drg No CE/TD/1202/03 Sheet 1/2 & 2/2. |
| 19 | Soakage well of size 3 M dia X 4.50 M deep including excavation in any type of soil, foundation in pcc 1:3:6, well of honey combed built in brick work in CM 1:4. and RCC cover M-25 concrete, filling with brick bats, complete all as specified & shown on Drg No CE/TD-1202/03 sheet 1/2 & 2/2. |
| 20 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cementt concrete 1:2:4 type B-1 smooth finished, and reforming benching as required, internal dia of pipe in 150mm, complete all as specified and directed. |
| 21 | Cleaning of sewage line 150mm/200mm internal dia at any depth including manholes by removing the manhole covers of any size and cleaning by means of hydraulic jet pressure / vaccum suction machine as required at site from and well flushing with water after cleaning including getting out sludge if any and liquid materials from connecting manholes deposited in sewer lines removing the solids and sludge to any distance/ place outside the defence land and reinstating the manhole cover to its original position (cost of removal of sludge/ liquid materials from sewage lines and manholes in the same line is included in the rate quoted and for keeping particular sewage line which is undertaken once for cleaning, functional for full contract period) complete all as specified and directed. |
| 22 | Taking out/pumping contaminated sewage water from septic tank/soakage well incl inlet/outlet chamber after plugging in the incoming sewage line by suction(vaccum) type machine mounted on LMV/HMV and facility of high pressure vaccume and removing and dumping off the same in tank to a place out side contonment at the place marked for the purpose by local municipality or the authority controling the area as directed.Note :- Contractors are advised to ascertain the place suitable/earmarked for disposal of sludge/sewage water from local municipality or area controling authority before quoting their rates. Disposal of waste at suitable place shall be sole responsibility of contractors and no representation or objection in this regard will be entertained at any later stage. |
| 23 | Removing of manholes cover, keeping aside and cleaning silt/sewage/garbage etc from manholes. clearing blockage by rodding manually or mechanically complete to the entire satisfaction of Engr-in-Charge. |
| 24 | Removing of grating and refixing with cement afer cleaning the blockage, keeping aside and cleaning silt/sewage/garbage etc from the gully trap. Clearing blockage by rodding manually or mechanically complete all as specified and directed. |
| 25 | Clearing the blockage of WC and sewage lines manually upto first manhole complete all as specified and directed. |
| 26 | Clearing the blockage of bathroom/kitchen upto gully trap by rodding manually complete all as specified and directed. |
| 27 | Vitreous China floor mounted Single piece wash down water closet pan (pedestal pattern)(size 370mm x 670mm x 720mm) with UF soft close slim seat cover,Hinges, Dual Flush cistern fitting, fixing accessories and set with \\"S\\" trap size 300mm including connection to drain (or outgoing pipe), antisyphonage pipe, etc.. complete fixed in repairs complete all as specified and directed.. |
| 28 | Vitreous China urinal with CP spreader Chrome finish hole and fixing accessories Half stall type (back or corner wall type)(size 355mm x 340mm x535mm) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; including PVC Connection,waste pipe and coupling. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) fixed in repairs complete all as specified and as directed by Engineer-in-Charge. Make- Jaquar Cat part no. URS-WHT-13261H or its equivalent cat part of make as specified in the list of makes, as approved by GE. |
| 29 | Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water etc all as specified and as directed. |
| 30 | Rendering 10 mm thick in cement and sand mortar 1:6 on fair faces of brick work or cement concrete surfaces and finished even and smooth without using extra cement complete all as specified and as directed. |
| 31 | Rendering 15 mm thick in cement and sand mortar 1:4 on fair faces of brick work or cement concrete surfaces including finishing the surface even and smooth without using extra cement, complete all as specified and as directed. |
| 32 | Rendering 5mm thick cement plaster with cement mortar(1:3) on concrete surface as in ceiling finished even and smooth without using extra cement, complete all as specified and as directed. |
| 33 | Preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and as directed. |
| 34 | Preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed. |
| 35 | Preparation of newly plastered surfaces of walls and applying two coats of cement base paint complete all as specified and as directed. |
| 36 | Preparation of newly plastered surfaces of walls and applying chalk whitening and applying two coats of oil bound distemper over one coat of primer complete all as specified and as directed. |
| 37 | Preparation of old painted surfaces by washing, rubbing down and stopping of distempered and painted walls and applying one coats of oil bound distemper complete all as specified and as directed. |
| 38 | Preparation of old painted surfaces by washing, rubbing down and stopping of plastered surfaces and applying one coats of cement base paint white or tined on wall complete all as specified and as directed. |
| 39 | Preparing old surface (plastered or unplastered) surfaces of walls including cornices, pilasters etc by washing, rubbing, stopping brooming down with steel wire brushing and applying two coats of white wash on walls, complete all as specified. |
| 40 | Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level ) complete all as specified and as directed. |
| 41 | 50mm thick PCC (1:3:6) type C-2 (Using 40mm graded stone aggregate) as in plinth protection laid in bays n.exc 2.00 Sqm complete including finishing the surface of concrete topping even & fair. The joints shall be filled with mastic filling, complete all as specified and as directed. |
| 42 | Vitreous china squatting pan \\"Orissa Pattern\\" size 580 x 440 mm in white colour with integral foot rest incl lime mortor, 'P' trap fixed in repairs complete all as specified and as directed.Cat Part No-20042 (ORISSA PAN (ECO)) of Hindware or equivalent cat part of make NEYCER, CERA, PARRYWARE as approved by GE. |
| 43 | Vitreous china Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe), with brass grating and union for discharge pipe fixed in repairs, complete all as specified. |
| 44 | PVC connection 15 mm size, of length 450 mm, with PTMT nuts fixed in repairs, complete all as specified and as directed. |
| 45 | Brass chromium plated fancy type wall mixture for mixing of hot and cold water supply screwed down including connecting leg & wall flange for iron pipe 15 mm bore fixed in repair complete all as specified and as directed. |
| 46 | Vitreous china wash down water closet pan pedestal pattern in white colour with 'P' or 'S' traps excluding seat cover, flushing cistern and flush pipe fixed in repairs complete all as specified and directed. Cat Part No-20011 (SLICK) of Hindware or equivalent cat part of make as specified in the list of makes as approved by GE. |
| 47 | Repair to balcony/facia and soffit of chajjas etc by taking down old plastered surfaces and hacking clearly the edges and corners smooth and rounded for new plastered area exceeding 30sqcm in width or girth & applying rendering 15 mm thick dubbing coat where required to match with the existing thickness in CM 1:4 including formwork/scaffolding work upto height 7.00mtr above ground level of bldg complete all as specified and as directed. |
| 48 | Plastic water closet seat cover white closed pattern with flat bottom and cover including chromium plated hinges device fixed in repairs, complete all as specified and as directed. |
| 49 | Ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe 20 mm dia (minimum weight 210 gms) complete all as specified. |
| 50 | 20mm bore gun metal glove or gate valve with iron wheel head screwed bith end for iron pipe and fixed in repairs, complete all as specified and as directed. |
| 51 | Taking up or down steel tubing of 15mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to store with all fittings, complete all as specified and directed. |
| 52 | Ditto all as per item no 51 here-in-before but 20mm bore. |
| 53 | 15mm bore tubes, medium grade, galvanised with and including all fittings fixed to walls, floors, or ceiling or laid in floors etc complete all as specified and as directed. |
| 54 | Ditto all as per item no 53 here-in-before but 20mm bore. |
| 55 | Refixing old steel tubing and connections in new or old position on walls, ceiling or floors etc of size 15 mm bore after cleaning including provn of new fittings, complete all as directed. |
| 56 | Ditto all as per item No. 55 above here-in-before but 20mm bore. |
| 57 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 58 | 25 mm thick PCC 1:2:4 type B-0, (using 12.5mm graded crushed stone aggregate) as in sub base / levelling cousre including finishing surface of concrete topping even and rough , complete all as specified and as directed. |
| 59 | Non skid coloured ceramic tiles 7 to 8 mm thick(square / rectangular) area of each tile exceeding 0.11sqm but not exceeding 0.18sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shed of tiles over and including 15mm thick screed bed in CM (1:6), complete all as specified and directed. |
| 60 | Ditto all as per item No.59 but in skirting over and including 10mm thick rendering in CM 1:4. |
| 61 | Glazed ceramic tiles 450 x 300 x 7mm thick / 350 x 250 x 7mm thick (coloured) on vertical surfaces such as skirtings, dados etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10 mm thick rendering in CM 1:4 complete all as specified and directed. |
| 62 | Taking down and refixing including resecuring and easing shutters area exceeding 1.00 sqm and n.exc 2.00 Sqm each in the same opening complete all as specified and as directed. |
| 63 | Taking down eaves gutters and rain water pipe , soil and waste pipe (any size or pattern), including all fittings, heads , shoes bends , swan-necks etc complete all as specified and directed. |
| 64 | PVC (SWR) pipes 110mm bore any length single socketed with rubber ring joint laid in trenches/floors or fixed to wall in repairs, complete all as specified and directed. |
| 65 | 110mm bore PVC SWR pipes single socket in any length with rubber ring joints fixed to wall with PVC/MS holder clamp etc., complete all as specified and directed. |
| 66 | PVC (SWR) pipes 75mm bore any length single socketed with rubber ring joint laid in trenches/floors or fixed to wall in repairs, complete all as specified and directed. |
| 67 | 75mm bore PVC SWR pipes single socket in any length with rubber ring joints fixed to wall with PVC/MS holder clamp etc., complete all as specified and directed. |
| 68 | PVC SWR reducer 110mm to 75 mm complete all as specified and directed. |
| 69 | PVC (SWR) vent cowl for 75mm dia fixed, all as specified. |
| 70 | PVC (SWR) bend 110 mm dia any radius all as specified and directed |
| 71 | PVC (SWR) junction single, (Single T) equal or unequal of 110mm bore provided with access door, complete all as specified and directed. |
| 72 | PVC SWR bends any radius 75mm bore complete all as specified. |
| 73 | PVC (SWR) 75 mm dia floor trap plain with grating including jointing with solvent cement fixed in repairs, all as specified and directed |
| 74 | PVC (SWR) junction single, (Single T) equal or unequal of 75mm bore provided with access door, complete all as specified and directed. |
| 75 | Rotational moulded polyethylene water storage tanks of 1000 litres capacity,three layered and white in colour (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc including taking down existing tank complete all as specified and directed. |
| 76 | Rotational moulded polyethylene water storage tanks of 500 litres capacity,three layered and white in colour (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc including taking down existing tank complete all as specified and directed. |
| 77 | Cleaning of water tank of any description with using bleaching powder, harpic etc and removing all sale dirt from tank and from mouth of circulating tank and wiping, drying etc complete capacity in ltr n. exc.1000 liter including removing float valve if required and refixing the same/new one for proper functioning of water tank after cleaning all as specified and directed. |
| 78 | Cleaning of water tank of any description with using bleaching powder, harpic etc and removing all sale dirt from tank and from mouth of circulating tank and wiping, drying etc complete capacity in ltr n. exc.2000 liter including removing float valve if required and refixing the same/new one for proper functioning of water tank after cleaning all as specified and directed. Please Enable Macros to View BoQ information |